Advertisement for orthosearch.org.uk
Results 1 - 3 of 3
Results per page:
The Bone & Joint Journal
Vol. 107-B, Issue 1 | Pages 65 - 71
1 Jan 2025
van Laarhoven SN Nota SPFT van Hellemondt GG Schreurs BW Wymenga AB Heesterbeek PJC

Aims

Tibial fixation in revision total knee arthroplasty (rTKA) can present surgical challenges. It has been suggested that appropriate fixation in at least two of the three anatomical zones (epiphysis, metaphysis, and diaphysis) is essential for implant survival. However, supporting clinical data are lacking. In this retrospective case-control study, we investigated the relationship between zonal fixation of hybrid rTKA tibial components and re-revision total knee arthroplasty for aseptic loosening (rrTKA-AL).

Methods

All consecutive rTKAs with hybrid tibial components (May 2006 to December 2020) were screened for subsequent rrTKA-AL. A control group was randomly selected from the remaining cohort. Postoperative radiographs of rTKAs were scored in random order by three blinded observers for zonal fixation in the epiphysis (bone resection level below, at, or above fibular head; 0 to 2), metaphysis (number of sufficiently cemented zones; 0 to 4), and diaphysis (canal filling ratio (CFR); %). The intraclass correlation coefficient (ICC) was calculated to quantify the agreement between observers. Multivariate logistic regression analysis was performed to assess the relationship between zonal fixation and rrTKA-AL.


The Bone & Joint Journal
Vol. 105-B, Issue 1 | Pages 35 - 46
1 Jan 2023
Mills K Wymenga AB BĂ©nard MR Kaptein BL Defoort KC van Hellemondt GG Heesterbeek PJC

Aims

The aim of this study was to compare a bicruciate-retaining (BCR) total knee arthroplasty (TKA) with a posterior cruciate-retaining (CR) TKA design in terms of kinematics, measured using fluoroscopy and stability as micromotion using radiostereometric analysis (RSA).

Methods

A total of 40 patients with end-stage osteoarthritis were included in this randomized controlled trial. All patients performed a step-up and lunge task in front of a monoplane fluoroscope one year postoperatively. Femorotibial contact point (CP) locations were determined at every flexion angle and compared between the groups. RSA images were taken at baseline, six weeks, three, six, 12, and 24 months postoperatively. Clinical and functional outcomes were compared postoperatively for two years.


The Bone & Joint Journal
Vol. 104-B, Issue 7 | Pages 875 - 883
1 Jul 2022
Mills K Wymenga AB van Hellemondt GG Heesterbeek PJC

Aims

Both the femoral and tibial component are usually cemented at revision total knee arthroplasty (rTKA), while stems can be added with either cemented or press-fit (hybrid) fixation. The aim of this study was to compare the long-term stability of rTKA with cemented and press-fitted stems, using radiostereometric analysis (RSA).

Methods

This is a follow-up of a randomized controlled trial, initially involving 32 patients, of whom 19 (nine cemented, ten hybrid) were available for follow-up ten years postoperatively, when further RSA measurements were made. Micromotion of the femoral and tibial components was assessed using model-based RSA software (RSAcore). The clinical outcome was evaluated using the Knee Society Score (KSS), the Knee injury and Osteoarthritis Outcome Score (KOOS), and visual analogue scale (pain and satisfaction).