Advertisement for orthosearch.org.uk
Results 1 - 2 of 2
Results per page:
The Bone & Joint Journal
Vol. 97-B, Issue 9 | Pages 1232 - 1236
1 Sep 2015
Shafafy R McClatchie W Chettiar K Gill K Hargrove R Sturridge S Guyot A

Infection is a leading indication for revision arthroplasty. Established criteria used to diagnose prosthetic joint infection (PJI) include a range of laboratory tests. Leucocyte esterase (LE) is widely used on a colorimetric reagent strip for the diagnosis of urinary tract infections. This inexpensive test may be used for the diagnosis or exclusion of PJI. Aspirates from 30 total hip arthroplasties (THAs) and 79 knee arthroplasties (KA) were analysed for LE activity. Semi-quantitative reagent strip readings of 15, 70, 125 and 500 white blood cells (WBC) were validated against a manual synovial white cell count (WCC). A receiver operating characteristic (ROC) curve was constructed to determine the optimal cut-off point for the semi-quantitative results. Based on established criteria, six THAs and 15 KAs were classified as infected. The optimal cut-off point for the diagnosis of PJI was 97 WBC. The closest semi-quantitative reading for a positive result was 125 WBC, achieving a sensitivity of 81% and a specificity of 93%. The positive and negative predictive values of the LE test strip were 74% and 95% respectively.

The LE reagent strip had a high specificity and negative predictive value. A negative result may exclude PJI and negate the need for further diagnostic tests.

Cite this article: Bone Joint J 2015;97-B:1232–6.


The Bone & Joint Journal
Vol. 95-B, Issue 4 | Pages 554 - 557
1 Apr 2013
Dinneen A Guyot A Clements J Bradley N

Cut-off values with highest sensitivity and specificity for the synovial fluid white cell and differential count will facilitate the accurate diagnosis of infection in total knee (TKR) and total hip replacement (THR). All patients undergoing revision TKR or THR for suspected prosthetic joint infection between 2009 and 2011 at two hospitals were identified. A total of 75 patients were included with a mean age of 70.3 years (38 to 89). Synovial fluid was aspirated pre-operatively and peri-prosthetic tissue samples were taken intra-operatively for histological and microbiological examination.

Receiver operating characteristic (ROC) plots were constructed for white cell and differential counts in aspirated fluid. The optimal cut-off for TKR and THR was 1590 white cells/µl and 65% neutrophilia. The white cell count cut-off value identified for THR was notably lower than previously quoted in the literature. A cut-off value for white cell count in synovial aspirate in suspected prosthetic joint infection of between 1100 and 1700 white cells/µl is likely to be applicable to both THR and TKR.

Cite this article: Bone Joint J 2013;95-B:554–7.