Appropriate acetabular component placement has been proposed for prevention of postoperative dislocation in total hip arthroplasty (THA). Manual placements often cause outliers in spite of attempts to insert the component within the intended safe zone; therefore, some surgeons routinely evaluate intraoperative pelvic radiographs to exclude excessive acetabular component malposition. However, their evaluation is often ambiguous in case of the tilted or rotated pelvic position. The purpose of this study was to develop the computational analysis to digitalize the acetabular component orientation regardless of the pelvic tilt or rotation. Intraoperative pelvic radiographs of 50 patients who underwent THA were collected retrospectively. The 3D pelvic bone model and the acetabular component were image-matched to the intraoperative pelvic radiograph. The radiological anteversion (RA) and radiological inclination (RI) of the acetabular component were calculated and those measurement errors from the postoperative CT data were compared relative to those of the 2D measurements. In addition, the intra- and interobserver differences of the image-matching analysis were evaluated.Aims
Methods
In order to clarify how intra-articular lesions
influence the survival of a periacetabular osteotomy in patients
with dysplasia of the hip, we performed an observational study of
121 patients (121 hips) who underwent a transposition osteotomy
of the acetabulum combined with an arthroscopy. Their mean age was
40.2 years (13 to 64) and the mean follow-up was 9.9 years (2 to
18). Labral and cartilage degeneration tended to originate from
the anterosuperior part of the acetabulum, followed by the femoral
side. In all, eight hips (6.6%) had post-operative progression to
Kellgren–Lawrence grade 4 changes, and these hips were associated
with the following factors: moderate osteoarthritis, decreased width
of the joint space, joint incongruity, and advanced intra-articular
lesions (subchondral bone exposure in the cartilage and a full-thickness
labral tear). Multivariate analysis indicated subchondral bone exposure
on the femoral head as an independent risk factor for progression
of osteoarthritis (p = 0.003). In hips with early stage osteoarthritis,
femoral subchondral bone exposure was a risk factor for progression of
the grade of osteoarthritis. Although the outcome of transposition osteotomy of the acetabulum
was satisfactory, post-operative progression of osteoarthritis occurred
at a high rate in hips with advanced intra-articular lesions, particularly
in those where the degenerative process had reached the point of
femoral subchondral bone exposure.
In order to investigate the mechanisms of collapse in osteonecrosis of the femoral head, we examined which part of the femoral head was the key point of a collapse and whether a collapsed region was associated with the size of the necrotic lesion. Using 30 consecutive surgically removed femoral heads we retrospectively analysed whole serial cut sections, specimen photographs, specimen radiographs and histological sections. In all of the femoral heads, collapse consistently involved a fracture at the lateral boundary of the necrotic lesion. Histologically, the fractures occurred at the junction between the thickened trabeculae of the reparative zone and the necrotic bone trabeculae. When the medial boundary of the necrotic lesion was located lateral to the fovea of the femoral head, 18 of 19 femoral heads collapsed in the subchondral region. By contrast, when the medial boundary was located medial to the fovea, collapse in the subchondral region was observed in four of 11 femoral heads (p = 0.0011). We found that collapse began at the lateral boundary of the necrotic lesion and that the size of the necrotic lesion seemed to contribute to its distribution.
We investigated the factors related to the radiological outcome of a transtrochanteric curved varus osteotomy in patients with osteonecrosis of the hip. We reviewed 73 hips in 62 patients with a mean follow-up of 12.4 years (5 to 31.1). There were 28 men and 34 women, with a mean age of 33.3 years (15 to 68) at the time of surgery. The 73 hips were divided into two groups according to their radiological findings: group 1 showed progression of collapse and/or joint-space narrowing; group 2 had neither progressive collapse nor joint-space narrowing. Both of these factors and the radiological outcomes were analysed by a stepwise discriminant analysis. A total of 12 hips were categorised as group 1 and 61 as group 2. Both the post-operative intact ratio and the localisation of the necrotic lesion correlated with the radiological outcome. The cut-off point of the postoperative intact ratio to prevent the progression of collapse was 33.6%, and the cut-off point to prevent both the progression of collapse and joint-space narrowing was 41.9%. The results of this study indicate that a post-operative intact ratio of 33.0% is necessary if a satisfactory outcome is to be achieved after this varus osteotomy.
Transtrochanteric curved varus osteotomy was designed to avoid some of the disadvantages of varus wedge osteotomy, such as post-operative leg-length discrepancy. In this retrospective study we investigated the leg-length discrepancy and clinical outcome after transtrochanteric curved varus osteotomy undertaken in patients with osteonecrosis of the femoral head. Between January 1993 and March 2004, this osteotomy was performed in 42 hips of 36 patients with osteonecrosis of the femoral head. There were 15 males and 21 females with a mean age at surgery of 34 years (15 to 68). The mean follow-up was 5.9 years (2.0 to 12.5). The mean pre-operative Harris hip score was 64.0 (43 to 85) points, which improved to a mean of 88.7 (58 to 100) points at final follow-up. The mean varus angulation post-operatively was 25° (12° to 38°) and the post-operative mean leg-length discrepancy was 13 mm (4 to 25). The post-operative leg-length discrepancy showed a strong correlation with varus angulation (Pearson’s correlation coefficient; r = 0.9530, p <
0.0001), which may be useful for predicting the leg-length discrepancy which can occur even after transtrochanteric curved varus osteotomy.
Our study evaluated the accuracy of an image-guided total knee replacement system based on CT with regard to preparation of the femoral and tibial bone using nine limbs from five cadavers. The accuracy was assessed by direct measurement using an extramedullary alignment rod without radiographs. The mean angular errors of the femur and tibia, which represent angular gaps from the real mechanical axis in the coronal plane, were 0.3° and 1.1°, respectively. The CT-based system, provided almost perfect alignment of the femoral component with less than 1° of error and excellent alignment with less than 3° of error for the tibial component. Our results suggest that standardisation of knee replacement by the use of this system will lead to improved long-term survival of total knee arthroplasty.