Soliman O Koptan W Zarad A

In Neer type II (Robinson type 3B) fractures of the distal clavicle the medial fragment is detached from the coracoclavicular ligaments and displaced upwards, whereas the lateral fragment, which is usually small, maintains its position. Several fixation techniques have been suggested to treat this fracture. The aim of this study was to assess the outcome of patients with type II distal clavicle fractures treated with coracoclavicular suture fixation using three loops of Ethibond. This prospective study included 14 patients with Neer type II fractures treated with open reduction and coracoclavicular fixation. Ethibond sutures were passed under the coracoid and around the clavicle (UCAC loop) without making any drill holes in the proximal or distal fragments. There were 11 men and three women with a mean age of 34.57 years (29 to 41). Patients were followed for a mean of 24.64 months (14 to 31) and evaluated radiologically and clinically using the Constant score. Fracture union was obtained in 13 patients at a mean of 18.23 weeks (13 to 23) and the mean Constant score was 96.07 (91 to 100). One patient developed an asymptomatic fibrous nonunion at one year. This study suggests that open reduction and internal fixation of unstable distal clavicle fractures using UCAC loops can provide rigid fixation and lead to bony union. This technique avoids using metal hardware, preserves the acromioclavicular joint and provides adequate stability with excellent results. Cite this article: Bone Joint J 2013;95-B:983–7


Bone & Joint Open
Vol. 3, Issue 12 | Pages 953 - 959
23 Dec 2022
Raval P See A Singh HP

Aims. Distal third clavicle (DTC) fractures are increasing in incidence. Due to their instability and nonunion risk, they prove difficult to treat. Several different operative options for DTC fixation are reported but current evidence suggests variability in operative fixation. Given the lack of consensus, our objective was to determine the current epidemiological trends in DTC as well as their management within the UK. Methods. A multicentre retrospective cohort collaborative study was conducted. All patients over the age of 18 with an isolated DTC fracture in 2019 were included. Demographic variables were recorded: age; sex; side of injury; mechanism of injury; modified Neer classification grading; operative technique; fracture union; complications; and subsequent procedures. Baseline characteristics were described for demographic variables. Categorical variables were expressed as frequencies and percentages. Results. A total of 859 patients from 18 different NHS trusts (15 trauma units and three major trauma centres) were included. The mean age was 57 years (18 to 99). Overall, 56% of patients (n = 481) were male. The most common mechanisms of injury were simple fall (57%; n = 487) and high-energy fall (29%; n = 248); 87% (n = 748) were treated conservatively and 54% (n = 463) were Neer type I fractures. Overall, 32% of fractures (n = 275) were type II (22% type IIa (n = 192); 10% type IIb (n = 83)). With regards to operative management, 89% of patients (n = 748) who underwent an operation were under the age of 60. The main fixation methods were: hook plate (n = 47); locking plate (n = 34); tightrope (n = 5); and locking plate and tight rope (n = 7). Conclusion. Our study is the largest epidemiological review of DTC fractures in the UK. It is also the first to review the practice of DTC fixation. Most fractures are being treated nonoperatively. However, younger patients, suffering a higher-energy mechanism of injury, are more likely to undergo surgery. Hook plates are the predominantly used fixation method followed by locking plate. The literature is sparse on the best method of fixation for optimal outcomes for these patients. To answer this, a pragmatic RCT to determine optimal fixation method is required. Cite this article: Bone Jt Open 2022;3(12):953–959


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 2 | Pages 291 - 294
1 Mar 1991
Ballmer F Gerber C

Five consecutive unstable fractures of the distal third of the clavicle were treated by indirect open reduction and internal fixation using a temporary Bosworth-type screw. Coracoclavicular fixation provided and maintained reduction of the fracture. Healing occurred uneventfully within nine weeks in all cases. The screw was removed under local anaesthesia after healing of the fracture and there were no surgical complications. Shoulder function was restored to the pre-injury level. Temporary coracoclavicular screw fixation appears to be a valuable alternative for the treatment of type II fractures of the distal third of the clavicle.


Bone & Joint 360
Vol. 11, Issue 4 | Pages 32 - 35
1 Aug 2022


The Bone & Joint Journal
Vol. 106-B, Issue 10 | Pages 1100 - 1110
1 Oct 2024
Arenas-Miquelez A Barco R Cabo Cabo FJ Hachem A

Bone defects are frequently observed in anterior shoulder instability. Over the last decade, knowledge of the association of bone loss with increased failure rates of soft-tissue repair has shifted the surgical management of chronic shoulder instability. On the glenoid side, there is no controversy about the critical glenoid bone loss being 20%. However, poor outcomes have been described even with a subcritical glenoid bone defect as low as 13.5%. On the humeral side, the Hill-Sachs lesion should be evaluated concomitantly with the glenoid defect as the two sides of the same bipolar lesion which interact in the instability process, as described by the glenoid track concept. We advocate adding remplissage to every Bankart repair in patients with a Hill-Sachs lesion, regardless of the glenoid bone loss. When critical or subcritical glenoid bone loss occurs in active patients (> 15%) or bipolar off-track lesions, we should consider anterior glenoid bone reconstructions. The techniques have evolved significantly over the last two decades, moving from open procedures to arthroscopic, and from screw fixation to metal-free fixation. The new arthroscopic techniques of glenoid bone reconstruction procedures allow precise positioning of the graft, identification, and treatment of concomitant injuries with low morbidity and faster recovery. Given the problems associated with bone resorption and metal hardware protrusion, the new metal-free techniques for Latarjet or free bone block procedures seem a good solution to avoid these complications, although no long-term data are yet available.

Cite this article: Bone Joint J 2024;106-B(10):1100–1110.


The Bone & Joint Journal
Vol. 104-B, Issue 11 | Pages 1234 - 1241
1 Nov 2022
Park JH Park KT Kim SC Bukhary HA Lee SM Yoo JC

Aims

This study compared patients who underwent arthroscopic repair of large to massive rotator cuff tears (LMRCTs) with isolated incomplete repair of the tear and patients with incomplete repair with biceps tendon augmentation. We aimed to evaluate the additional benefit on clinical outcomes and the capacity to lower the re-tear rate.

Methods

We retrospectively reviewed 1,115 patients who underwent arthroscopic rotator cuff repair for full-thickness tears between October 2011 and May 2019. From this series, we identified 77 patients (28 male, 49 female) with a mean age of 64.1 years (50 to 80). Patients were classified into groups A (n = 47 incomplete) and B (n = 30 with biceps augmentation) according to the nature of their reconstruction. Clinical scores were checked preoperatively and at six months, one year, and two years postoperatively. In preoperative MRI, we measured the tear size, the degree of fatty infiltration, and muscle volume ratio of the supraspinatus. In postoperative MRI, the integrity of the repaired rotator cuff tendon was assessed using the Sugaya classification. Tendon thickness at the footprint was evaluated on T2-weighted oblique coronal view.


Bone & Joint 360
Vol. 13, Issue 3 | Pages 31 - 34
3 Jun 2024

The June 2024 Shoulder & Elbow Roundup360 looks at: Reverse versus anatomical total shoulder replacement for osteoarthritis? A UK national picture; Acute rehabilitation following traumatic anterior shoulder dislocation (ARTISAN): pragmatic, multicentre, randomized controlled trial; acid for rotator cuff repair: a systematic review and meta-analysis of randomized controlled trials; Metal or ceramic humeral head total shoulder arthroplasty: an analysis of data from the National Joint Registry; Platelet-rich plasma has better results for long-term functional improvement and pain relief for lateral epicondylitis: a systematic review and meta-analysis of randomized controlled trials; Quantitative fatty infiltration and 3D muscle volume after nonoperative treatment of symptomatic rotator cuff tears: a prospective MRI study of 79 patients; Locking plates for non-osteoporotic proximal humeral fractures in the long term; A systematic review of the treatment of primary acromioclavicular joint osteoarthritis.


The Bone & Joint Journal
Vol. 106-B, Issue 9 | Pages 970 - 977
1 Sep 2024
De Rus Aznar I Ávila Lafuente JL Hachem A Díaz Heredia J Kany J Elhassan B Ruiz Ibán MÁ

Rotator cuff pathology is the main cause of shoulder pain and dysfunction in older adults. When a rotator cuff tear involves the subscapularis tendon, the symptoms are usually more severe and the prognosis after surgery must be guarded. Isolated subscapularis tears represent 18% of all rotator cuff tears and arthroscopic repair is a good alternative primary treatment. However, when the tendon is deemed irreparable, tendon transfers are the only option for younger or high-functioning patients. The aim of this review is to describe the indications, biomechanical principles, and outcomes which have been reported for tendon transfers, which are available for the treatment of irreparable subscapularis tears.

The best tendon to be transferred remains controversial. Pectoralis major transfer was described more than 30 years ago to treat patients with failed surgery for instability of the shoulder. It has subsequently been used extensively to manage irreparable subscapularis tendon tears in many clinical settings. Although pectoralis major reproduces the position and orientation of the subscapularis in the coronal plane, its position in the axial plane – anterior to the rib cage – is clearly different and does not allow it to function as an ideal transfer. Consistent relief of pain and moderate recovery of strength and function have been reported following the use of this transfer. In an attempt to improve on these results, latissimus dorsi tendon transfer was proposed as an alternative and the technique has evolved from an open to an arthroscopic procedure. Satisfactory relief of pain and improvements in functional shoulder scores have recently been reported following its use. Both pectoralis minor and upper trapezius transfers have also been used in these patients, but the outcomes that have been reported do not support their widespread use.

Cite this article: Bone Joint J 2024;106-B(9):970–977.


Bone & Joint 360
Vol. 11, Issue 3 | Pages 29 - 32
1 Jun 2022


Bone & Joint Open
Vol. 1, Issue 11 | Pages 683 - 690
1 Nov 2020
Khan SA Asokan A Handford C Logan P Moores T

Background

Due to the overwhelming demand for trauma services, resulting from increasing emergency department attendances over the past decade, virtual fracture clinics (VFCs) have become the fashion to keep up with the demand and help comply with the BOA Standards for Trauma and Orthopaedics (BOAST) guidelines. In this article, we perform a systematic review asking, “How useful are VFCs?”, and what injuries and conditions can be treated safely and effectively, to help decrease patient face to face consultations. Our primary outcomes were patient satisfaction, clinical efficiency and cost analysis, and clinical outcomes.

Methods

We performed a systematic literature search of all papers pertaining to VFCs, using the search engines PubMed, MEDLINE, and the Cochrane Database, according to the Preferred Reporting Items for Systematic review and Meta-Analysis (PRISMA) checklist. Searches were carried out and screened by two authors, with final study eligibility confirmed by the senior author.


The Bone & Joint Journal
Vol. 101-B, Issue 9 | Pages 1100 - 1106
1 Sep 2019
Schemitsch C Chahal J Vicente M Nowak L Flurin P Lambers Heerspink F Henry P Nauth A

Aims

The purpose of this study was to compare the effectiveness of surgical repair to conservative treatment and subacromial decompression for the treatment of chronic/degenerative tears of the rotator cuff.

Materials and Methods

PubMed, Cochrane database, and Medline were searched for randomized controlled trials published until March 2018. Included studies were assessed for methodological quality, and data were extracted for statistical analysis. The systematic review was conducted following PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines.


Bone & Joint 360
Vol. 7, Issue 2 | Pages 23 - 25
1 Apr 2018


The Bone & Joint Journal
Vol. 98-B, Issue 4 | Pages 512 - 518
1 Apr 2016
Spencer HT Hsu L Sodl J Arianjam A Yian EH

Aims

To compare radiographic failure and re-operation rates of anatomical coracoclavicular (CC) ligament reconstructional techniques with non-anatomical techniques after chronic high grade acromioclavicular (AC) joint injuries.

Patients and Methods

We reviewed chronic AC joint reconstructions within a region-wide healthcare system to identify surgical technique, complications, radiographic failure and re-operations. Procedures fell into four categories: (1) modified Weaver-Dunn, (2) allograft fixed through coracoid and clavicular tunnels, (3) allograft loop coracoclavicular fixation, and (4) combined allograft loop and synthetic cortical button fixation. Among 167 patients (mean age 38.1 years, (standard deviation (sd) 14.7) treated at least a four week interval after injury, 154 had post-operative radiographs available for analysis.


The Bone & Joint Journal
Vol. 95-B, Issue 12 | Pages 1595 - 1602
1 Dec 2013
Modi CS Beazley J Zywiel MG Lawrence TM Veillette CJH

The aim of this review is to address controversies in the management of dislocations of the acromioclavicular joint. Current evidence suggests that operative rather than non-operative treatment of Rockwood grade III dislocations results in better cosmetic and radiological results, similar functional outcomes and longer time off work. Early surgery results in better functional and radiological outcomes with a reduced risk of infection and loss of reduction compared with delayed surgery.

Surgical options include acromioclavicular fixation, coracoclavicular fixation and coracoclavicular ligament reconstruction. Although non-controlled studies report promising results for arthroscopic coracoclavicular fixation, there are no comparative studies with open techniques to draw conclusions about the best surgical approach. Non-rigid coracoclavicular fixation with tendon graft or synthetic materials, or rigid acromioclavicular fixation with a hook plate, is preferable to fixation with coracoclavicular screws owing to significant risks of loosening and breakage.

The evidence, although limited, also suggests that anatomical ligament reconstruction with autograft or certain synthetic grafts may have better outcomes than non-anatomical transfer of the coracoacromial ligament. It has been suggested that this is due to better restoration horizontal and vertical stability of the joint.

Despite the large number of recently published studies, there remains a lack of high-quality evidence, making it difficult to draw firm conclusions regarding these controversial issues.

Cite this article: Bone Joint J 2013;95-B:1595–1602.


The Bone & Joint Journal
Vol. 99-B, Issue 1 | Pages 107 - 115
1 Jan 2017
Carr A Cooper C Campbell MK Rees J Moser J Beard DJ Fitzpatrick R Gray A Dawson J Murphy J Bruhn H Cooper D Ramsay C

Aims

The appropriate management for patients with a degenerative tear of the rotator cuff remains controversial, but operative treatment, particularly arthroscopic surgery, is increasingly being used. Our aim in this paper was to compare the effectiveness of arthroscopic with open repair of the rotator cuff.

Patients and Methods

A total of 273 patients were recruited to a randomised comparison trial (136 to arthroscopic surgery and 137 to open surgery) from 19 teaching and general hospitals in the United Kingdom. The surgeons used their usual preferred method of repair. The Oxford Shoulder Score (OSS), two years post-operatively, was the primary outcome measure. Imaging of the shoulder was performed at one year after surgery. The trial is registered with Current Controlled Trials, ISRCTN97804283.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 6 | Pages 697 - 707
1 Jun 2008
Fraser-Moodie JA Shortt NL Robinson CM

Injuries to the acromioclavicular joint are common but underdiagnosed. Sprains and minor subluxations are best managed conservatively, but there is debate concerning the treatment of complete dislocations and the more complex combined injuries in which other elements of the shoulder girdle are damaged. Confusion has been caused by existing systems for classification of these injuries, the plethora of available operative techniques and the lack of well-designed clinical trials comparing alternative methods of management. Recent advances in arthroscopic surgery have produced an even greater variety of surgical options for which, as yet, there are no objective data on outcome of high quality. We review the current concepts of the treatment of these injuries.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 8 | Pages 1088 - 1092
1 Aug 2011
Lizaur A Sanz-Reig J Gonzalez-Parreño S

The purpose of this study was to review the long-term outcomes of a previously reported prospective series of 46 type III acromioclavicular dislocations. These were treated surgically with temporary fixation of the acromioclavicular joint with wires, repair of the acromioclavicular ligaments, and overlapped suture of the deltoid and trapezius muscles. Of the 46 patients, one had died, four could not be traced, and three declined to return for follow-up, leaving 38 patients in the study. There were 36 men and two women, with a mean age at follow-up of 57.3 years (41 to 71). The mean follow-up was 24.2 years (21 to 26).

Patients were evaluated using the Imatani and University of California, Los Angeles (UCLA) scoring systems. Their subjective status was assessed using the Disabilities of the Arm, Shoulder and Hand and Simple Shoulder Test questionnaires, and a visual analogue scale for patient satisfaction. The examination included radiographs of the shoulder.

At a follow-up of 21 years, the results were satisfactory in 35 (92.1%) patients and unsatisfactory in three (7.9%). In total, 35 patients (92.1%) reported no pain, one slight pain, and two moderate pain. All except two patients had a full range of shoulder movement compared with the opposite side. Unsatisfactory results were the result of early redisplacement in two patients, and osteoarthritis without redisplacement in one. According to the Imatani and UCLA scores, there was no difference between the operated shoulder and the opposite shoulder (p > 0.05). Given the same situation, 35 (92.1%) patients would opt for the same surgical treatment again.

Operative treatment of type III acromioclavicular joint injuries produces satisfactory long-term results.


The Bone & Joint Journal
Vol. 97-B, Issue 12 | Pages 1657 - 1661
1 Dec 2015
Taranu R Rushton PRP Serrano-Pedraza I Holder L Wallace WA Candal-Couto JJ

Dislocation of the acromioclavicular joint is a relatively common injury and a number of surgical interventions have been described for its treatment. Recently, a synthetic ligament device has become available and been successfully used, however, like other non-native solutions, a compromise must be reached when choosing non-anatomical locations for their placement. This cadaveric study aimed to assess the effect of different clavicular anchorage points for the Lockdown device on the reduction of acromioclavicular joint dislocations, and suggest an optimal location. We also assessed whether further stability is provided using a coracoacromial ligament transfer (a modified Neviaser technique). The acromioclavicular joint was exposed on seven fresh-frozen cadaveric shoulders. The joint was reconstructed using the Lockdown implant using four different clavicular anchorage points and reduction was measured. The coracoacromial ligament was then transferred to the lateral end of the clavicle, and the joint re-assessed. If the Lockdown ligament was secured at the level of the conoid tubercle, the acromioclavicular joint could be reduced anatomically in all cases. If placed medial or 2 cm lateral, the joint was irreducible. If the Lockdown was placed 1 cm lateral to the conoid tubercle, the joint could be reduced with difficulty in four cases. Correct placement of the Lockdown device is crucial to allow anatomical joint reduction. Even when the Lockdown was placed over the conoid tubercle, anterior clavicle displacement remained but this could be controlled using a coracoacromial ligament transfer.

Cite this article: Bone Joint J 2015;97-B:1657–61.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 1 | Pages 164 - 168
1 Jan 2010
Chen MR Huang JI Victoroff BN Cooperman DR

In an osteological collection of 3100 specimens, 70 were found with unilateral clavicular fractures which were matched with 70 randomly selected normal specimens. This formed the basis of a study of the incidence of arthritis of the acromioclavicular joint and the effect of clavicular fracture on the development of arthritis in the ipsilateral acromioclavicular joint. This was graded visually on a severity scale of 0 to 3. The incidence of moderate to severe arthritis of the acromioclavicular joint in normal specimens was 77% (100 specimens). In those with a clavicular fracture, 66 of 70 (94%) had arthritis of the acromioclavicular joint, compared to 63 of 70 (90%) on the non-injured contralateral side (p = 0.35).

Clavicles with shortening of 15 mm or less had no difference in the incidence of arthritis compared to those with shortening greater than 15 mm (p = 0.25). The location of the fracture had no effect on the development of arthritis.


Bone & Joint 360
Vol. 5, Issue 6 | Pages 27 - 29
1 Dec 2016