Advertisement for orthosearch.org.uk
Results 1 - 5 of 5
Results per page:
The Bone & Joint Journal
Vol. 97-B, Issue 12 | Pages 1628 - 1633
1 Dec 2015
Elmadag M Uzer G Yildiz F Erden T Bilsel K Büyükpinarbasili N Üsümez A Bozdag E Sen C

This animal study compares different methods of performing an osteotomy, including using an Erbium-doped Yttrium Aluminum Garnet laser, histologically, radiologically and biomechanically. A total of 24 New Zealand rabbits were divided into four groups (Group I: multihole-drilling; Group II: Gigli saw; Group III: electrical saw blade and Group IV: laser). A proximal transverse diaphyseal osteotomy was performed on the right tibias of the rabbits after the application of a circular external fixator. The rabbits were killed six weeks after the procedure, the operated tibias were resected and radiographs taken.

The specimens were tested biomechanically using three-point bending forces, and four tibias from each group were examined histologically. Outcome parameters were the biomechanical stability of the tibias as assessed by the failure to load and radiographic and histological examination of the osteotomy site.

The osteotomies healed in all specimens both radiographically and histologically. The differences in the mean radiographic (p = 0.568) and histological (p = 0.71) scores, and in the mean failure loads (p = 0.180) were not statistically significant between the groups.

Different methods of performing an osteotomy give similar quality of union. The laser osteotomy, which is not widely used in orthopaedics is an alternative to the current methods.

Cite this article: Bone Joint J 2015;97-B:1628–33.


The Bone & Joint Journal
Vol. 97-B, Issue 11 | Pages 1577 - 1581
1 Nov 2015
Balci HI Kocaoglu M Sen C Eralp L Batibay SG Bilsel K

A retrospective study was performed in 18 patients with achondroplasia, who underwent bilateral humeral lengthening between 2001 and 2013, using monorail external fixators. The mean age was ten years (six to 15) and the mean follow-up was 40 months (12 to 104).

The mean disabilities of the arm, shoulder and hand (DASH) score fell from 32.3 (20 to 40) pre-operatively to 9.4 (6 to 14) post-operatively (p = 0.037). A mean lengthening of 60% (40% to 95%) was required to reach the goal of independent perineal hygiene. One patient developed early consolidation, and fractures occurred in the regenerate bone of four humeri in three patients. There were three transient radial nerve palsies.

Humeral lengthening increases the independence of people with achondroplasia and is not just a cosmetic procedure.

Cite this article: Bone Joint J 2015;97-B:1577–81.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 1 | Pages 52 - 56
1 Jan 2011
Kocaoglu M Bilen FE Sen C Eralp L Balci HI

We present the results of the surgical correction of lower-limb deformities caused by metabolic bone disease. Our series consisted of 17 patients with a diagnosis of hypophosphataemic rickets and two with renal osteodystrophy; their mean age was 25.6 years (14 to 57). In all, 43 lower-limb segments (27 femora and 16 tibiae) were osteotomised and the deformity corrected using a monolateral external fixator. The segment was then stabilised with locked intramedullary nailing. In addition, six femora in three patients were subsequently lengthened by distraction osteogenesis. The mean follow-up was 60 months (18 to 120). The frontal alignment parameters (the mechanical axis deviation, the lateral distal femoral angle and the medial proximal tibial angle) and the sagittal alignment parameters (the posterior distal femoral angle and the posterior proximal tibial angle) improved post-operatively. The external fixator was removed either at the end of surgery or at the end of the lengthening period, allowing for early mobilisation and weight-bearing. We encountered five problems and four obstacles in the programme of treatment.

The use of intramedullary nails prevented recurrence of deformity and refracture.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 12 | Pages 1615 - 1619
1 Dec 2007
Piskin A Tomak Y Sen C Tomak L

Cubitus varus and valgus are the most common complications of supracondylar and lateral condylar fractures. Various combinations of osteotomy and fixation have been described to correct these deformities but each is associated with significant complications. In this study, we used distraction osteogenesis and Ilizarov frame fixation to treat 24 elbows in 23 patients with cubitus varus or valgus. Their clinical outcome was evaluated using the protocol of Bellemore et al. The mean time to follow-up was 18.3 months (10 to 36) and the mean time to frame removal was 13.5 weeks (8 to 20). The mean carrying angle was corrected from −18.7° (−10° to −30°) to 6.1° (2° to 10°) in patients with cubitus varus and from 36.5° (25° to 45°) to 9.4° (4° to 15°) in patients with cubitus valgus. There were 18 excellent and six good results.

The Ilizarov method with gradual distraction is a safe, stable, adjustable and versatile method of treating deformities at the elbow without the problems of an unsightly scar or limited range of movement, and gives a good clinical and radiological outcome. Tardy ulnar nerve palsy should be treated first by anterior transposition.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 6 | Pages 783 - 789
1 Jun 2006
Sen C Eralp L Gunes T Erdem M Ozden VE Kocaoglu M

In this retrospective study we evaluated the method of acute shortening and distraction osteogenesis for the treatment of tibial nonunion with bone loss in 17 patients with a mean age of 36 years (10 to 58). The mean bone loss was 5.6 cm (3 to 10). In infected cases, we performed the treatment in two stages. The mean follow-up time was 43.5 months (24 to 96). The mean time in external fixation was 8.0 months (4 to 13) and the mean external fixator index was 1.4 months/cm (1.1 to 1.8). There was no recurrence of infection. The bone evaluation results were excellent in 16 patients and good in one, while functional results were excellent in 15 and good in two. The complication rate was 1.2 per patient.

We conclude that acute shortening and distraction osteogenesis is a safe, reliable and successful method for the treatment of tibial nonunion with bone loss, with a shorter period of treatment and lower rate of complication.