To report mid- to long-term results of Oxford mobile bearing domed lateral unicompartmental knee arthroplasty (UKA), and determine the effect of potential contraindications on outcome. A total of 325 consecutive domed lateral UKAs undertaken for the recommended indications were included, and their functional and survival outcomes were assessed. The effects of age, weight, activity, and the presence of full-thickness erosions of cartilage in the patellofemoral joint on outcome were evaluated.Aims
Methods
The primary stability of the cementless Oxford Unicompartmental Knee Replacement (OUKR) relies on interference fit (or press fit). Insufficient interference may cause implant loosening, whilst excessive interference could cause bone damage and fracture. The aim of this study was to identify the optimal interference fit by measuring the force required to seat the tibial component of the cementless OUKR (push-in force) and the force required to remove the component (pull-out force). Six cementless OUKR tibial components were implanted in 12 new slots prepared on blocks of solid polyurethane foam (20 pounds per cubic foot (PCF), Sawbones, Malmo, Sweden) with a range of interference of 0.1 mm to 1.9 mm using a Dartec materials testing machine HC10 (Zwick Ltd, Herefordshire, United Kingdom) . The experiment was repeated with cellular polyurethane foam (15 PCF), which is a more porous analogue for trabecular bone.Objectives
Materials and Methods
It is not clear whether anterior knee pain and osteoarthritis
(OA) of the patellofemoral joint (PFJ) are contraindications to
medial unicompartmental knee arthroplasty (UKA). Our aim was to
investigate the long-term outcome of a consecutive series of patients,
some of whom had anterior knee pain and PFJ OA managed with UKA. We assessed the ten-year functional outcomes and 15-year implant
survival of 805 knees (677 patients) following medial mobile-bearing
UKA. The intra-operative status of the PFJ was documented and, with
the exception of bone loss with grooving to the lateral side, neither
the clinical or radiological state of the PFJ nor the presence of
anterior knee pain were considered a contraindication. The impact
of radiographic findings and anterior knee pain was studied in a
subgroup of 100 knees (91 patients).Aims
Patients and Methods
While medial unicompartmental knee arthroplasty (UKA) is indicated
for patients with full-thickness cartilage loss, it is occasionally
used to treat those with partial-thickness loss. The aim of this
study was to investigate the five-year outcomes in a consecutive
series of UKAs used in patients with partial thickness cartilage
loss in the medial compartment of the knee. Between 2002 and 2014, 94 consecutive UKAs were undertaken in
90 patients with partial thickness cartilage loss and followed up
independently for a mean of six years (1 to 13). These patients
had partial thickness cartilage loss either on both femur and tibia
(13 knees), or on either the femur or the tibia, with full thickness
loss on the other surface of the joint (18 and 63 knees respectively).
Using propensity score analysis, these patients were matched 1:2 based
on age, gender and pre-operative Oxford Knee Score (OKS) with knees
with full thickness loss on both the femur and tibia. The functional
outcomes, implant survival and incidence of re-operations were assessed
at one, two and five years post-operatively. A subgroup of 36 knees
in 36 patients with partial thickness cartilage loss, who had pre-operative
MRI scans, was assessed to identify whether there were any factors
identified on MRI that predicted the outcome.Aims
Patients and Methods
An evidence-based radiographic Decision Aid for meniscal-bearing
unicompartmental knee arthroplasty (UKA) has been developed and
this study investigates its performance at an independent centre. Pre-operative radiographs, including stress views, from a consecutive
cohort of 550 knees undergoing arthroplasty (UKA or total knee arthroplasty;
TKA) by a single-surgeon were assessed. Suitability for UKA was
determined using the Decision Aid, with the assessor blinded to
treatment received, and compared with actual treatment received, which
was determined by an experienced UKA surgeon based on history, examination,
radiographic assessment including stress radiographs, and intra-operative
assessment in line with the recommended indications as described
in the literature.Aims
Patients and Methods
We performed a systematic review of the literature
pertaining to the functional outcomes of the surgical management
of acetabular fractures. A total of 69 articles met our inclusion
criteria, revealing that eight generic outcome instruments were
used, along with five specific instruments. The majority of studies
reported outcomes using a version of the d’Aubigne and Postel score,
which has not been validated for use in acetabular fracture. Few validated
outcome measures were reported. No psychometric testing of outcome
instruments was performed. The current assessment of outcomes in
surgery for acetabular fractures lacks scientific rigour, and does
not give reliable outcome data for either scientific comparison
or patient counselling. Take home message: The use of non-validated functional outcome
measures is a major limitation of the current literature pertaining
to surgical management of acetabular fractures; future studies should
use validated outcome measures to ensure the legitimacy of the reported
results. Cite this article:
The global economy has been facing a financial crisis. Healthcare costs are spiraling, and there is a projected £30 billion health funding gap by 2020 in the UK. What is happening in the UK is a reflection of a global problem. Rationing of healthcare is a topic of much discussion; as unless spending is capped, providing healthcare will become unsustainable. Who decides how money is spent, and which services should be rationed? In this article we aim to discuss the impact that rationing may have on orthopaedic surgery, and we will discuss our own experiences of attempts to ration local services.
This prospective study reports the 15-year survival and ten-year
functional outcome of a consecutive series of 1000 minimally invasive
Phase 3 Oxford medial UKAs (818 patients, 393 men, 48%, 425 women,
52%, mean age 66 years; 32 to 88). These were implanted by two surgeons
involved with the design of the prosthesis to treat anteromedial
osteoarthritis and spontaneous osteonecrosis of the knee, which
are recommended indications. Patients were prospectively identified
and followed up independently for a mean of 10.3 years (5.3 to 16.6). At ten years, the mean Oxford Knee Score was 40 (standard deviation
( This is the only large series of minimally invasive UKAs with
15-year survival data. The results support the continued use of
minimally invasive UKA for the recommended indications. Cite this article:
There is a large amount of evidence available
about the relative merits of unicompartmental and total knee arthroplasty
(UKA and TKA). Based on the same evidence, different people draw
different conclusions and as a result, there is great variability
in the usage of UKA. The revision rate of UKA is much higher than TKA and so some
surgeons conclude that UKA should not be performed. Other surgeons
believe that the main reason for the high revision rate is that
UKA is easy to revise and, therefore, the threshold for revision
is low. They also believe that UKA has many advantages over TKA
such as a faster recovery, lower morbidity and mortality and better
function. They therefore conclude that UKA should be undertaken
whenever appropriate. The solution to this argument is to minimise the revision rate
of UKA, thereby addressing the main disadvantage of UKA. The evidence
suggests that this will be achieved if surgeons use UKA for at least
20% of their knee arthroplasties and use implants that are appropriate
for these broad indications. Cite this article:
The most common reasons for revision of unicompartmental
knee arthroplasty (UKA) are loosening and pain. Cementless components
may reduce the revision rate. The aim of this study was to compare
the fixation and clinical outcome of cementless and cemented Oxford
UKAs. A total of 43 patients were randomised to receive either a cemented
or a cementless Oxford UKA and were followed for two years with
radiostereometric analysis (RSA), radiographs aligned with the bone–implant
interfaces and clinical scores. The femoral components migrated significantly during the first
year (mean 0.2 mm) but not during the second. There was no significant
difference in the extent of migration between cemented and cementless
femoral components in either the first or the second year. In the
first year the cementless tibial components subsided significantly
more than the cemented components (mean 0.28 mm ( As second-year migration is predictive of subsequent loosening,
and as radiolucency is suggestive of reduced implant–bone contact,
these data suggest that fixation of the cementless components is
at least as good as, if not better than, that of cemented devices. Cite this article:
The cementless Oxford unicompartmental knee replacement
has been demonstrated to have superior fixation on radiographs and
a similar early complication rate compared with the cemented version.
However, a small number of cases have come to our attention where,
after an apparently successful procedure, the tibial component subsides into
a valgus position with an increased posterior slope, before becoming
well-fixed. We present the clinical and radiological findings of
these six patients and describe their natural history and the likely
causes. Two underwent revision in the early post-operative period,
and in four the implant stabilised and became well-fixed radiologically with
a good functional outcome. This situation appears to be avoidable by minor modifications
to the operative technique, and it appears that it can be treated
conservatively in most patients. Cite this article:
Mobile-bearing unicompartmental knee replacements
(UKRs) with a flat tibial plateau have not performed well in the
lateral compartment, owing to a high dislocation rate. This led
to the development of the Domed Lateral Oxford UKR (Domed OUKR)
with a biconcave bearing. The aim of this study was to assess the
survival and clinical outcomes of the Domed OUKR in a large patient
cohort in the medium term. We prospectively evaluated 265 consecutive knees with isolated
disease of the lateral compartment and a mean age at surgery of
64 years (32 to 90). At a mean follow-up of four years ( The Domed Lateral OUKR gives good clinical outcomes, low re-operation
and revision rates and a low dislocation rate in patients with isolated
lateral compartmental disease, in the hands of the designer surgeons. Cite this article:
The Cementless Oxford Unicompartmental Knee Replacement
(OUKR) was developed to address problems related to cementation,
and has been demonstrated in a randomised study to have similar
clinical outcomes with fewer radiolucencies than observed with the
cemented device. However, before its widespread use it is necessary
to clarify contraindications and assess the complications. This
requires a larger study than any previously published. We present a prospective multicentre series of 1000 cementless
OUKRs in 881 patients at a minimum follow-up of one year. All patients
had radiological assessment aligned to the bone–implant interfaces
and clinical scores. Analysis was performed at a mean of 38.2Â months
(19 to 88) following surgery. A total of 17 patients died (comprising
19 knees (1.9%)), none as a result of surgery; there were no tibial
or femoral loosenings. A total of 19Â knees (1.9%) had significant
implant-related complications or required revision. Implant survival
at six years was 97.2%, and there was a partial radiolucency at
the bone–implant interface in 72 knees (8.9%), with no complete radiolucencies.
There was no significant increase in complication rate compared
with cemented fixation (p = 0.87), and no specific contraindications
to cementless fixation were identified. Cementless OUKR appears to be safe and reproducible in patients
with end-stage anteromedial osteoarthritis of the knee, with radiological
evidence of improved fixation compared with previous reports using
cemented fixation. Cite this article:
The Oxford unicompartmental knee replacement
(UKR) is an established treatment option in the management of symptomatic
end-stage medial compartmental osteoarthritis (MCOA), which works
well in the young and active patient. However, previous studies
have shown that it is reliable only in the presence of a functionally
intact anterior cruciate ligament (ACL). This review reports the
outcomes, at a mean of five years and a maximum of ten years, of 52
consecutive patients with a mean age of 51 years (36 to 57) who
underwent staged or simultaneous ACL reconstruction and Oxford UKR.
At the last follow-up (with one patient lost to follow-up), the
mean Oxford knee score was 41 ( In summary, ACL reconstruction and Oxford UKR gives good results
in patients with end-stage MCOA secondary to ACL deficiency.
The contraindications for unicompartmental knee replacement (UKR) remain controversial. The views of many surgeons are based on Kozinn and Scott’s 1989 publication which stated that patients who weighed more than 82 kg, were younger than 60 years, undertook heavy labour, had exposed bone in the patellofemoral joint or chondrocalcinosis, were not ideal candidates for UKR. Our aim was to determine whether these potential contraindications should apply to patients with a mobile-bearing UKR. In order to do this the outcome of patients with these potential contraindications was compared with that of patients without the contraindications in a prospective series of 1000 UKRs. The outcome was assessed using the Oxford knee score, the American Knee Society score, the Tegner activity score, revision rate and survival. The clinical outcome of patients with each of the potential contraindications was similar to or better than those without each contraindication. Overall, 678 UKRs (68%) were performed in patients who had at least one potential contraindication and only 322 (32%) in patients deemed to be ideal. The survival at ten years was 97.0% (95% confidence interval 93.4 to 100.0) for those with potential contraindications and 93.6% (95% confidence interval 87.2 to 100.0) in the ideal patients. We conclude that the thresholds proposed by Kozinn and Scott using weight, age, activity, the state of the patellofemoral joint and chondrocalcinosis should not be considered to be contraindications for the use of the Oxford UKR.
This prospective study describes the outcome of the first 1000 phase 3 Oxford medial unicompartmental knee replacements (UKRs) implanted using a minimally invasive surgical approach for the recommended indications by two surgeons and followed up independently. The mean follow-up was 5.6 years (1 to 11) with 547 knees having a minimum follow-up of five years. At five years their mean Oxford knee score was 41.3 ( The incidence of implant-related re-operations was 2.9%; of these 29 re-operations two were revisions requiring revision knee replacement components with stems and wedges, 17 were conversions to a primary total knee replacement, six were open reductions for dislocation of the bearing, three were secondary lateral UKRs and one was revision of a tibial component. The most common reason for further surgical intervention was progression of arthritis in the lateral compartment (0.9%), followed by dislocation of the bearing (0.6%) and revision for unexplained pain (0.6%). If all implant-related re-operations are considered failures, the ten-year survival rate was 96% (95% confidence interval, 92.5 to 99.5). If only revisions requiring revision components are considered failures the ten-year survival rate is 99.8% (confidence interval 99 to 100). This is the largest published series of UKRs implanted through a minimally invasive surgical approach and with ten-year survival data. The survival rates are similar to those obtained with a standard open approach whereas the function is better. This demonstrates the effectiveness and safety of a minimally invasive surgical approach for implanting the Oxford UKR.
Periprosthetic infection following total hip replacement can be a catastrophic complication for the patient. The treatments available include single-stage exchange, and two-stage exchange. We present a series of 50 consecutive patients with a diagnosis of infected total hip replacement who were assessed according to a standardised protocol. Of these, 11 underwent single-stage revision arthroplasty with no recurrence of infection at a mean of 6.8 years follow-up (5.5 to 8.8). The remaining 39 underwent two-stage revision, with two recurrences of infection successfully treated by a second two-stage procedure. At five years, significant differences were found in the mean Harris Hip Scores (single-stage 87.8; two-stage 75.5; p = 0.0003) and in a visual analogue score for satisfaction (8.6; 6.9; p = 0.001) between the single- and two-stage groups. Single-stage exchange is successful in eradicating periprosthetic infection and results in excellent functional and satisfaction scores. Identification of patients suitable for the single-stage procedure allows individualisation of care and provides as many as possible with the correct strategy in successfully tackling their periprosthetic infection
The Oxford Unicompartmental Knee replacement (UKR) was introduced as a design to reduce polyethylene wear. There has been one previous retrieval study involving this implant, which reported very low rates of wear in some specimens but abnormal patterns of wear in others. There has been no further investigation of these abnormal patterns. The bearings were retrieved from 47 patients who had received a medial Oxford UKR for anteromedial osteoarthritis of the knee. None had been studied previously. The mean time to revision was 8.4 years ( These results show that very low rates of polyethylene wear are possible if the device functions normally. However, if the bearing displays suboptimal function (extra-articular, intra-articular impingement or incongruous articulation) the rates of wear increase significantly.
With medial unicompartmental osteoarthritis (OA) there is occasionally a full-thickness ulcer of the cartilage on the medial side of the lateral femoral condyle. It is not clear whether this should be considered a contraindication to unicompartmental knee replacement (UKR). The aim of this study was to determine why these ulcers occur, and whether they compromise the outcome of UKR. Case studies of knees with medial OA suggest that cartilage lesions on the medial side of the lateral condyle are caused by impingement on the lateral tibial spine as a result of the varus deformity and tibial subluxation. Following UKR the varus and the subluxation are corrected, so that impingement is prevented and the damaged part of the lateral femoral condyle is not transmitting load. An illustrative case report is presented. Out of 769 knees with OA of the medial compartment treated with the Oxford UKR, 59 (7.7%) had partial-thickness cartilage loss and 20 (2.6%) had a full-thickness cartilage deficit on the medial side of the lateral condyle. The mean Oxford Knee Score (OKS) at the last follow-up at a mean of four years was 41.9 (13 to 48) in those with partial-thickness cartilage loss and 41.0 (20 to 48) in those with full-thickness loss. In those with normal or superficially damaged cartilage the mean was 39.5 (5 to 48) and 39.7 (8 to 48), respectively. There were no statistically significant differences between the pre-operative OKS, the final review OKS or of change in the score in the various groups. We conclude that in medial compartment OA, damage to the medial side of the lateral femoral condyle is caused by impingement on the tibial spine and should not be considered a contraindication to an Oxford UKR, even if there is extensive full-thickness ulceration of the cartilage.
Narrow, well-defined radiolucent lines commonly observed at the bone-implant interface of unicompartmental knee replacement tibial components have been referred to as physiological radiolucencies. These should be distinguished from pathological radiolucencies, which are poorly defined, wide and progressive, and associated with loosening and infection. We studied the incidence and clinical significance of tibial radiolucent lines in 161 Oxford unicondylar knee replacements five years after surgery. All the radiographs were aligned with fluoroscopic control to obtain views parallel to the tibial tray to reveal the tibial bone-implant interface. We found that 49 knees (30%) had complete, 52 (32%) had partial and 60 (37%) had no radiolucent lines. There was no relationship between the incidence of radiolucent lines and patient factors such as gender, body mass index and activity, or operative factors including the status of the anterior cruciate ligament and residual varus deformity. Nor was any statistical relationship established between the presence of radiolucent lines and clinical outcome, particularly pain, assessed by the Oxford Knee score and the American Knee Society score. We conclude that radiolucent lines are common after Oxford unicompartmental knee replacement but that their aetiology remains unclear. Radiolucent lines were not a source of adverse symptoms or pain. Therefore, when attempting to identify a source of postoperative pain after Oxford unicompartmental knee replacement the presence of a physiological radiolucency should be ignored.
Varus malalignment after total knee replacement is associated with a poor outcome. Our aim was to determine whether the same was true for medial unicompartmental knee replacement (UKR). The anatomical leg alignment was measured prospectively using a long-arm goniometer in 160 knees with an Oxford UKR. Patients were then grouped according to their mechanical leg alignment as neutral (5° to 10° of valgus), mild varus (0° to 4° of valgus) and marked varus (>
0° of varus). The groups were compared at five years in terms of absolute and change in the Oxford Knee score, American Knee Society score and the incidence of radiolucent lines. Post-operatively, 29 (18%) patients had mild varus and 13 (8%) had marked varus. The mean American Knee Society score worsened significantly (p <
0.001) with increasing varus. This difference disappeared if a three-point deduction for each degree of malalignment was removed. No other score deteriorated with increasing varus, and the frequency of occurrence of radiolucent lines was the same in each group. We therefore conclude that after Oxford UKR, about 25% of patients have varus alignment, but that this does not compromise their clinical or radiological outcome. Following UKR the deductions for malalignment in the American Knee Society score are not justified.
We randomised 62 knees to receive either cemented or cementless versions of the Oxford unicompartmental knee replacement. The implants used in both arms of the study were similar, except that the cementless components were coated with porous titanium and hydroxyapatite. The tibial interfaces were studied with fluoroscopically-aligned radiographs. At one year there was no difference in clinical outcome between the two groups. Narrow radiolucent lines were seen at the bone-implant interfaces in 75% of cemented tibial components. These were partial in 43%, and complete in 32%. In the cementless implants, partial radiolucencies were seen in 7% and complete radiolucencies in none. These differences are statistically significant (p <
0.0001) and imply satisfactory bone ingrowth into the cementless implants.
The Vancouver classification has been shown by its developers to be a valid and reliable method for categorising the configuration of periprosthetic proximal femoral fractures and for planning their management. We have re-validated this classification system independently using the radiographs of 30 patients with periprosthetic fractures. These were reviewed by six experienced consultant orthopaedic surgeons, six trainee surgeons and six medical students in order to assess intra- and interobserver reliability and reproducibility. Each observer read the radiographs on two separate occasions. The results were subjected to weighted kappa statistical analysis. The respective kappa values for interobserver agreement were 0.72 and 0.74 for consultants, 0.68 and 0.70 for trainees on the first and second readings of the radiographs and 0.61 for medical students. The intra-observer agreement for the consultants was 0.64 and 0.67, for the trainees 0.61 and 0.64, and for the medical students 0.59 and 0.60 for the first and second readings, respectively. The validity of the classification was studied by comparing the pre-operative radiological findings within B subgroups with the operative findings. This revealed agreement for 77% of these type-B fractures, with a kappa value of 0.67. Our data confirm the reliability and reproducibility of this classification system in a European setting and for inexperienced staff. This is a reliable system which can be used by non-experts, between centres and across continents.
Patellofemoral joint degeneration is often considered a contraindication to medial unicompartmental knee replacement. We examined the validity of this preconception using information gathered prospectively on the intra-operative status of the patellofemoral joint in 824 knees in 793 consecutive patients who underwent Oxford unicondylar knee replacement for anteromedial osteoarthritis. All operations were performed between January 1998 and September 2005. A five-point grading system classified degeneration of the patellofemoral joint from none to full-thickness cartilage loss. A subclassification of the presence or absence of any full-thickness cartilage loss was subsequently performed to test selected hypotheses. Outcome was evaluated independently by physiotherapists using the Oxford and the American Knee Society Scores with a minimum follow-up of one year. Full-thickness cartilage loss on the trochlear surface was observed in 100 of 785 knees (13%), on the medial facet of the patella in 69 of 782 knees (9%) and on the lateral facet in 29 of 784 knees (4%). Full-thickness cartilage loss at any location was seen in 128 knees (16%) and did not produce a significantly worse outcome than those with a normal or near-normal joint surface. The severity of the degeneration at any of the intra-articular locations also had no influence on outcome. We concluded that, provided there is not bone loss and grooving of the lateral facet, damage to the articular cartilage of the patellofemoral joint to the extent of full-thickness cartilage loss is not a contraindication to the Oxford mobile-bearing unicompartmental knee replacement.
Anterior knee pain and/or radiological evidence of degeneration of the patellofemoral joint are considered to be contraindications to unicompartmental knee replacement. The aim of this study was to determine whether this is the case. Between January 2000 and September 2003, in 100 knees (91 patients) in which Oxford unicompartmental knee replacements were undertaken for anteromedial osteoarthritis, pre-operative anterior knee pain and the radiological status of the patellofemoral joint were defined using the Altman and Ahlback systems. Outcome was evaluated at two years with the Oxford knee score and the American Knee Society score. Pre-operatively 54 knees (54%) had anterior knee pain. The clinical outcome was independent of the presence or absence of pre-operative anterior knee pain. Degenerative changes of the patellofemoral joint were seen in 54 patients (54%) on the skyline radiographs, including ten knees (10%) with joint space obliteration. Patients with medial patellofemoral degeneration had a similar outcome to those without. For some outcome measures patients with lateral patellofemoral degeneration had a worse score than those without, but these patients still had a good outcome, with a mean Oxford knee score of 37.6 (SD 9.5). These results show that neither anterior knee pain nor radiologically-demonstrated medial patellofemoral joint degeneration should be considered a contraindication to Oxford unicompartmental knee replacement. With lateral patellofemoral degeneration the situation is less well defined and caution should be observed.
The options for treatment of the young active patient with isolated symptomatic osteoarthritis of the medial compartment and pre-existing deficiency of the anterior cruciate ligament are limited. The potential longevity of the implant and levels of activity of the patient may preclude total knee replacement, and tibial osteotomy and unicompartmental knee arthroplasty are unreliable because of the ligamentous instability. Unicompartmental knee arthroplasties tend to fail because of wear or tibial loosening resulting from eccentric loading. Therefore, we combined reconstruction of the anterior cruciate ligament with unicompartmental arthroplasty of the knee in 15 patients (ACLR group), and matched them with 15 patients who had undergone Oxford unicompartmental knee arthroplasty with an intact anterior cruciate ligament (ACLI group). The clinical and radiological data at a minimum of 2.5 years were compared for both groups. The groups were well matched for age, gender and length of follow-up and had no significant differences in their pre-operative scores. At the last follow-up, the mean outcome scores for both the ACLR and ACLI groups were high (Oxford knee scores of 46 (37 to 48) and 43 (38 to 46), respectively, objective Knee Society scores of 99 (95 to 100) and 94 (82 to 100), and functional Knee Society scores of 96 and 96 (both 85 to 100). One patient in the ACLR group needed revision to a total knee replacement because of infection. No patient in either group had radiological evidence of component loosening. The radiological study showed no difference in the pattern of tibial loading between the groups. The short-term clinical results of combined anterior cruciate ligament reconstruction and unicompartmental knee arthroplasty are excellent. The previous shortcomings of unicompartmental knee arthroplasty in the presence of deficiency of the anterior cruciate ligament appear to have been addressed with the combined procedure. This operation seems to be a viable treatment option for young active patients with symptomatic arthritis of the medial compartment, in whom the anterior cruciate ligament has been ruptured.
This prospective study describes the complications and survival of the first 688 Phase 3 Oxford medial unicompartmental knee replacements implanted using a minimally-invasive technique by two surgeons and followed up independently. None was lost to follow-up. We had carried out 132 of the procedures more than five years ago. The clinical assessment of 101 of these which were available for review at five years is also presented. Nine of the 688 knees were revised: four for infection, three for dislocation of the bearing and two for unexplained pain. A further seven knees (1%) required other procedures: four had a manipulation under anaesthesia, two an arthroscopy and one a debridement for superficial infection. The survival rate at seven years was 97.3% (95% confidence interval 5.3). At five years, 96% of the patients had a good or excellent American Knee Society score, the mean Oxford knee score was 39 and the mean flexion was 133°. This study demonstrates that the minimally-invasive Oxford unicompartmental knee replacement is a reliable and effective procedure.
Polyethylene particulate wear debris continues to be implicated in the aetiology of aseptic loosening following knee arthroplasty. The Oxford unicompartmental knee arthroplasty employs a spherical femoral component and a fully congruous meniscal bearing to increase contact area and theoretically reduce the potential for polyethylene wear. This study measures the In this The results from this
We present a comparison of the results of the Oxford unicompartmental knee arthroplasty in patients younger and older than 60 years of age. The ten-year all-cause survival of the <
60 years of age group (52) was 91% (95% confidence interval (CI) 12), while in the ≥ 60 years of age group (512), the figure was 96% (95% CI 3). For the younger group, the mean Hospital for Special Surgery score at ten-year follow-up (n = 21) was 94 of 100, compared with a mean of 86 of 100 for the older group (n = 135). The results show that the Oxford unicompartmental arthroplasty can achieve ten-year results that are comparable to total knee arthroplasty in patients <
60 years of age. We conclude that for patients aged over 50, age should not be considered a contraindication for this procedure.
Before proceeding to longer-term studies, we have studied the early clinical results of a new mobile-bearing total knee prosthesis in comparison with an established fixed-bearing device. Patients requiring bilateral knee replacement consented to have their operations under one anaesthetic using one of each prosthesis. They also agreed to accept the random choice of knee (right or left) and to remain ignorant as to which side had which implant. Outcomes were measured using the American Knee Society Score (AKSS), the Oxford Knee Score (OKS), and determination of the range of movement and pain scores before and at one year after operation. Preoperatively, there was no systematic difference between the right and left knees. One patient died in the perioperative period and one mobile-bearing prosthesis required early revision for dislocation of the meniscal component. At one year the mean AKSS, OKS and pain scores for the new device were slightly better (p <
0.025) than those for the fixed-bearing device. There was no difference in the range of movement. We believe that this is the first controlled, blinded trial to compare early function of a new knee prosthesis with that of a standard implant. It demonstrates a small but significant clinical advantage for the mobile-bearing design.
When the Oxford unicompartmental meniscal bearing arthroplasty is used in the lateral compartment of the knee, 10% of the bearings dislocate. A radiological review was carried out to establish if dislocation was related to surgical technique. The postoperative radiographs of 46 lateral unicompartmental arthroplasties were analysed. Five variables which related to the position and alignment of the components were measured. Dislocations occurred in six knees. Only one of the five variables, the proximal tibial varus angle, had a statistically significant relationship to dislocation. This variable quantifies the height of the lateral joint line. The mean proximal tibial varus angle for knees the bearings of which had dislocated was 9° and for those which had not it was 5°. In both groups it was greater than would be expected in the normal knee (3°). Our study suggests that a high proximal tibial varus angle is associated with dislocation. The surgical technique should be modified to account for this, with care being taken to avoid damage to or over-distraction of the lateral soft tissues.
We have assessed the effectiveness of reconstruction of the anterior cruciate ligament (ACL) in reducing functional tibial translation (TT). The gait of 11 ACL-deficient patients was studied using Vicon equipment before and after surgery. Measurements of the angle between the patellar tendon and the long axis of the tibia were obtained in order to calculate TT in the sagittal plane relative to the uninjured limb during standing and walking. Before surgery, patients did not show abnormal TT on the injured side, but after surgery significant anterior TT was found in the operated limb for every parameter of gait. Abnormal anterior TT occurring during activity does not seem to be reduced by reconstruction; rather, it increases. It may be that the increased translation results from relaxation of excess contraction of the hamstring muscles, since compensatory muscle activity no longer is required in a reconstructed knee. The reduction of TT may not be an appropriate objective in surgery on the ACL.
Satisfactory selection criteria are essential for the successful outcome of unicompartmental knee arthroplasty (UCA). We report the frequency of revision of the Oxford medial unicompartmental arthroplasty in knees previously treated for anteromedial osteoarthritis by high tibial osteotomy (HTO). The combined results from three sources were used to allow statistical analysis of this uncommon subgroup. In the combined series of 631 knees (507 patients) which had medial unicompartmental replacement, 613 were primary procedures and 18 were for a failed HTO. The mean follow-up times of the two groups were similar (5.8 years and 5.4 years, respectively). At review, 19 (3.1%) of the primary procedures and five (27.8%) of those undertaken for a failed HTO had been revised to total knee replacement. Survival analysis revealed the ten-year cumulative survivals to be 96% and 66%, respectively. The log-rank comparison of these survivals revealed a highly significant difference (p <
0.0001). We recommend that the Oxford UCA should not be used in knees which have previously undergone an HTO.
We performed a prospective, double-blind, randomised, clinical trial to investigate the efficacy of two regimes of rehabilitation for knees with anterior cruciate ligament deficiency (ACLD). Fifty ACLD patients were randomly allocated to one of two treatment groups: a programme of muscle strengthening (T) or a programme designed to enhance proprioception and improve hamstring contraction reflexes (P). An indirect measure of proprioception, the reflex hamstring contraction latency (RHCL), and a functional scoring system were used to record the status of the knee before and after the 12-week course of physiotherapy. Sagittal knee laxity was also measured. There was improvement in mean RHCL and in the mean functional score in both groups after treatment. The improvement in group P was significantly greater than that in group T. There was no significant change in joint laxity after treatment in either group. In both groups there was a positive correlation between improvement in RHCL and functional gain.
Septic arthritis has been regarded as rare in haemophiliacs, but its incidence may have increased since HIV infection has become widespread in these patients. We describe six cases treated at one haemophilia unit over a two-year period and discuss their investigation, diagnosis and treatment. Four of the patients were seropositive to anti-HIV.
Failure of conservative treatment is the usual indication for the reconstruction of a knee with deficiency of the anterior cruciate ligament (ACL) and this depends on subjective judgement. The ability of muscles to protect the subluxing joint by reflex contraction could provide an objective measurement. We have studied 30 patients with unilateral ACL deficiency by measuring the latency of reflex hamstring contraction. We found that the mean latency in the injured leg was nearly twice that in the unaffected limb (99 ms and 53 ms respectively). There was a significant correlation between the differential latency and the frequency of 'giving way' indicating that functional instability may be due, in part, to loss of proprioception. Measures of proprioception, including reflex hamstring latency, may be useful in providing an objective assessment of the efficacy of conservative treatment and the need for surgery.
We made a prospective study of 58 patients with suspected internal derangement of the knee. They were examined by magnetic resonance imaging using 3-D gradient echo intermediate-weighted studies before having an arthroscopy. The preoperative clinical assessment was found to have a diagnostic sensitivity of 77% and a specificity of 43%, compared with 100% and 63% respectively for magnetic resonance imaging. Comparison of magnetic resonance imaging and arthroscopy confirmed the accuracy of magnetic resonance imaging in the diagnosis of internal derangement but the results for articular cartilage lesions were much less good, with a sensitivity of only 18% but a specificity of 100%. Acceptance of the magnetic resonance imaging findings could have resulted in a 29% reduction in the number of arthroscopies without missing any significant meniscal lesion.
The quantification of local bone blood flow in man has not previously been possible, despite its importance in the study of normal and pathological bone. We report the use of positron emission tomography, using 15O-labelled water, to measure bone blood flow in patients with closed unilateral fractures of the tibia. We compared fractured and unfractured limbs; alterations in blood flow paralleled those found in animal models. There was increased tibial blood flow at the fracture site as early as 24 hours after fracture, reaching up to 14 times that in the normal limb at two weeks. Blood flow increase was less in displaced than in undisplaced fractures. The muscle to bone ratios of blood flow were similar to those in previous animal work using other techniques. Positron emission tomography will allow study of human bone blood flow in vivo in a wide variety of pathological conditions.
The results of 276 cemented revision total hip arthroplasties performed for aseptic failure between 1977 and 1986 have been reviewed. The mean time between revision and review was 75 months (range 30 to 144). Of 220 cases available for review, 159 were assessed clinically and radiographically, and 32 by postal questionnaire. Eighteen hips required further revision, 12 for loosening, two for sepsis, two for persistent pain, and one each for fracture and recurrent dislocation. A further six hips were radiologically and symptomatically loose. Pain was mild or absent in 83%. Over half were able to walk a mile or more; 70% flexed more than 70 degrees; 15% had a flexion deformity, but in only 7% was this more than 10 degrees. The mean Harris hip score was 74. Survival at five years was 95% and at 10 years, 77%.
The results of a study of the use of autograft versus allograft bone in the surgery of idiopathic adolescent scoliosis are presented. Two groups of patients, matched for age, sex, level and angle of curve, received bone grafts, 20 patients having autogenous bone from the iliac crest and the other 20 having donor bone from a bone bank. Both groups had otherwise identical posterior fusions and Harrington instrumentation. There was no difference between the two groups in a blind, radiographic assessment of bone graft mass at six months, nor in maintenance of the curve correction over the same period. No major operative complications nor failures of instrumentation were encountered. There was, however, a marked reduction in operative time and blood loss in the patients receiving donor bone and also a much lower incidence of late symptoms relating to the operative sites. We conclude that, even in the presence of adequate iliac crest, the use of bank bone is superior for grafting in idiopathic scoliosis surgery.