We have reviewed retrospectively 68 revisions of the femoral component in arthroplasties of the hip in 65 patients, using impaction bone grafting, at a median of three years (1 month to 6 years). We employed the cemented Exeter X-Change technique in 36 patients and the uncemented Bi-Metric allografting method in 32. The 37 bone defects were grade 3 or grade 4 on the Endo-Klinik classification. The Mayo hip score improved from a mean of 32 ( The risk of intraoperative fracture was prevented by supporting the bone with wires in 16 hips, with reinforcement mesh in 18 and by a plate in six. Early migration of the stem of more than 10 mm during the first year indicated rotational instability; it occurred in three cases. In difficult revision cases with large defects of the femoral bone, bone-impaction techniques carry a high risk of complications.
We randomised 50 patients with ankle fractures of Weber types B and C and a ruptured deltoid ligament treated by open reduction and internal fixation to two treatment groups to examine the influence of the repair of a ruptured deltoid ligament. No differences were found except for a longer duration of surgery in the repair group. Our findings suggest that a ruptured deltoid ligament can be left unexplored without any effect either on early mobilisation or on the long-term result.
We analysed the results of 93 tibial shaft fractures treated with the Grosse-Kempf locked nail. Twenty-six fractures were comminuted, 19 were open grade I to II, and 54 were located outside the middle third of the tibia. The deep infection rate was 3.2%. There were only two poor results. The use of this method is recommended and discussed.