Non-traumatic osteonecrosis of the femoral head
is a potentially devastating condition, the prevalence of which
is increasing. Many joint-preserving forms of treatment, both medical
and surgical, have been developed in an attempt to slow or reverse
its progression, as it usually affects young patients. However, it is important to evaluate the best evidence that is
available for the many forms of treatment considering the variation
in the demographics of the patients, the methodology and the outcomes
in the studies that have been published, so that it can be used
effectively. The purpose of this review, therefore, was to provide an up-to-date,
evidence-based guide to the management, both non-operative and operative,
of non-traumatic osteonecrosis of the femoral head. Cite this article:
We report the theoretical basis of a method to measure axial migration of femoral components of
Between November 1962 and December1990 a group of 1092 patients, 668 women and 424 men, under the age of 51 years at the time of surgery, underwent 1434 primary Charnley low-frictional torque arthroplasties and are being followed up indefinitely. Their mean age at operation was 41 years (12 to 51). At the latest review in June 2001 the mean follow-up had been for 15 years 1 month. Of the 1092 patients 54 (66 hips) could not be traced, 124 (169 hips) were known to have died and 220 (248 hips) had had a revision procedure. At a mean follow-up of 17 years and 5 months, 759 patients (951 hips) are still attending. In this group satisfaction with the outcome is 96.2%. The incidence of deep infection for the whole group was 1.67%. It was more common in patients who had had previous surgery (hemi- and
Surgical site infection can be a devastating complication of
hemiarthroplasty of the hip, when performed in elderly patients
with a displaced fracture of the femoral neck. It results in a prolonged
stay in hospital, a poor outcome and increased costs. Many studies
have identified risk and prognostic factors for deep infection.
However, most have combined the rates of infection following total
hip arthroplasty and internal fixation as well as hemiarthroplasty, despite
the fact that they are different entities. The aim of this study
was to clarify the risk and prognostic factors causing deep infection
after hemiarthroplasty alone. Data were extracted from a prospective hip fracture database
and completed by retrospective review of the hospital records. A
total of 916 patients undergoing a hemiarthroplasty in two level
II trauma teaching hospitals between 01 January 2011 and
01 May 2016 were included. We analysed the potential peri-operative
risk factors with univariable and multivariable logistic regression
analysis.Aims
Patients and Methods
The purpose of this study was to evaluate the existing literature from 2005 to 2016 reporting on the efficacy of surgical management of patients with femoroacetabular impingement (FAI) secondary to slipped capital femoral epiphysis (SCFE). The electronic databases MEDLINE, EMBASE, and PubMed were searched and screened in duplicate. Data such as patient demographics, surgical technique, surgical outcomes and complications were retrieved from eligible studies.Objectives
Methods
To determine the outcomes following revision surgery of metal-on-metal
hip arthroplasties (MoMHA) performed for adverse reactions to metal
debris (ARMD), and to identify factors predictive of re-revision. We performed a retrospective observational study using National
Joint Registry (NJR) data on 2535 MoMHAs undergoing revision surgery
for ARMD between 2008 and 2014. The outcomes studied following revision were
intra-operative complications, mortality and re-revision surgery.
Predictors of re-revision were identified using competing-risk regression
modelling.Aims
Patients and Methods
We have reviewed 70 patients with bilateral simultaneous
Patients seeking cervical spine surgery are thought to be increasing
in age, comorbidities and functional debilitation. The changing
demographics of this population may significantly impact the outcomes
of their care, specifically with regards to complications. In this
study, our goals were to determine the rates of functionally dependent
patients undergoing elective cervical spine procedures and to assess
the effect of functional dependence on 30-day morbidity and mortality
using a large, validated national cohort. A retrospective analysis of the American College of Surgeons
National Surgical Quality Improvement Program data files from 2006
to 2013 was conducted to identify patients undergoing common cervical
spine procedures. Multivariate logistic regression models were generated
to analyse the independent association of functional dependence
with 30-day outcomes of interest.Aims
Patients and Methods
The purpose of this article was to review the current literature
pertaining to the use of mobile compression devices (MCDs) for venous
thromboembolism (VTE) following total joint arthroplasty (TJA),
and to discuss the results of data from our institution. Previous studies have illustrated higher rates of post-operative
wound complications, re-operation and re-admission with the use
of more aggressive anticoagulation regimens, such as warfarin and
factor Xa inhibitors. This highlights the importance of the safety,
as well as efficacy, of the chemoprophylactic regimen.Aims
Patients and Methods
We report on the outcome of the Synergy cementless femoral stem
with a minimum follow-up of 15 years (15 to 17). A retrospective review was undertaken of a consecutive series
of 112 routine primary cementless total hip arthroplasties (THAs)
in 102 patients (112 hips). There were 60 female and 42 male patients
with a mean age of 61 years (18 to 82) at the time of surgery. A
total of 78 hips in the 69 patients remain Aims
Patients and Methods
We conducted a prospective study of a delta ceramic total hip
arthroplasty (THA) to determine the rate of ceramic fracture, to
characterise post-operative noise, and to evaluate the mid-term
results and survivorship. Between March 2009 and March 2011, 274 patients (310 hips) underwent
cementless THA using a delta ceramic femoral head and liner. At
each follow-up, clinical and radiological outcomes were recorded.
A Kaplan-Meier analysis was undertaken to estimate survival.Aims
Patients and Methods
The aim of this systematic literature review was to assess the clinical level of evidence of commercially available demineralised bone matrix (DBM) products for their use in trauma and orthopaedic related surgery. A total of 17 DBM products were used as search terms in two available databases: Embase and PubMed according to the Preferred Reporting Items for Systematic Reviews and Meta Analyses statement. All articles that reported the clinical use of a DBM-product in trauma and orthopaedic related surgery were included.Objectives
Methods
We reviewed a consecutive series of 527 uninfected hip replacements in patients resident in the UK which had been implanted from 1981 to 1993. All had the same basic design of femoral prosthesis, but four fixation techniques had been used: two press-fit, one HA-coated and one cemented. Review and radiography were planned prospectively. For assessment the components were retrospectively placed into two groups: those which had failed from two years onwards by aseptic femoral loosening and those in which the femoral component had survived without revision or recommendation for revision. All available radiographs in both groups were measured to determine vertical migration and examined by two observers to agree the presence of radiolucent lines (RLLs), lytic lesions, resorption of the neck, proximal osteopenia and distal intramedullary and distal subperiosteal formation of new bone. We then related the presence or absence of these features and the rate of migration at two years to the outcome with regard to aseptic loosening and determined the predictive value of each of these variables. Migration of ≥2 mm at two years, the presence of an RLL of 2 mm occupying one-third of any one zone, and subperiosteal formation of new bone at the tip of the stem were predictors of aseptic loosening after two years. There were too few lytic lesions to assess at two years, but at five years a lytic lesion ≥2 mm also predicted failure. We discuss the use of these variables as predictors of femoral aseptic loosening for groups of hips and for individual hips. We conclude that if a group of about 50