Advertisement for orthosearch.org.uk
Results 1921 - 1940 of 2262
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 2 | Pages 242 - 245
1 Feb 2010
Trollegaard AM Aarby NS Hellberg S

Between 1993 and 2008, 41 patients underwent total coccygectomy for coccydynia which had failed to respond to six months of conservative management. Of these, 40 patients were available for clinical review and 39 completed a questionnaire giving their evaluation of the effect of the operation. Excellent or good results were obtained in 33 of the 41 patients, comprising 18 of the 21 patients with coccydynia due to trauma, five of the eight patients with symptoms following childbirth and ten of 12 idiopathic onset. In eight patients the results were moderate or poor, although none described worse pain after the operation. The only post-operative complication was superficial wound infection which occurred in five patients and which settled fully with antibiotic treatment. One patient required re-operation for excision of the distal cornua of the sacrum.

Total coccygectomy offered satisfactory relief of pain in the majority of patients regardless of the cause of their symptoms.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 3 | Pages 374 - 379
1 Mar 2010
Kendrick BJL Rout R Bottomley NJ Pandit H Gill HS Price AJ Dodd CAF Murray DW

With medial unicompartmental osteoarthritis (OA) there is occasionally a full-thickness ulcer of the cartilage on the medial side of the lateral femoral condyle. It is not clear whether this should be considered a contraindication to unicompartmental knee replacement (UKR). The aim of this study was to determine why these ulcers occur, and whether they compromise the outcome of UKR.

Case studies of knees with medial OA suggest that cartilage lesions on the medial side of the lateral condyle are caused by impingement on the lateral tibial spine as a result of the varus deformity and tibial subluxation. Following UKR the varus and the subluxation are corrected, so that impingement is prevented and the damaged part of the lateral femoral condyle is not transmitting load. An illustrative case report is presented.

Out of 769 knees with OA of the medial compartment treated with the Oxford UKR, 59 (7.7%) had partial-thickness cartilage loss and 20 (2.6%) had a full-thickness cartilage deficit on the medial side of the lateral condyle. The mean Oxford Knee Score (OKS) at the last follow-up at a mean of four years was 41.9 (13 to 48) in those with partial-thickness cartilage loss and 41.0 (20 to 48) in those with full-thickness loss. In those with normal or superficially damaged cartilage the mean was 39.5 (5 to 48) and 39.7 (8 to 48), respectively. There were no statistically significant differences between the pre-operative OKS, the final review OKS or of change in the score in the various groups.

We conclude that in medial compartment OA, damage to the medial side of the lateral femoral condyle is caused by impingement on the tibial spine and should not be considered a contraindication to an Oxford UKR, even if there is extensive full-thickness ulceration of the cartilage.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 2 | Pages 222 - 226
1 Feb 2007
Cho HS Oh JH Kim H Kang HG Lee SH

Open surgery is rarely justified for the initial treatment of a unicameral bone cyst, but there is some debate concerning the relative effectiveness of closed methods. This study compared the results of steroid injection with those of autologous bone marrow grafting for the treatment of unicameral bone cysts. Between 1990 and 2001, 30 patients were treated by steroid injection and 28 by grafting with autologous bone marrow. The overall success rates were 86.7% and 92.0%, respectively (p > 0.05). The success rate after the initial procedure was 23.3% in the steroid group and 52.0% in those receiving autologous bone marrow (p < 0.05), and the respective cumulative success rates after second injections were 63.3% and 80.0% (p > 0.05). The mean number of procedures required was 2.19 (1 to 5) and 1.57 (1 to 3) (p < 0.05), the mean interval to healing was 12.5 months (4 to 32) and 14.3 months (7 to 36) (p > 0.05), and the rate of recurrence after the initial procedure was 41.7% and 13.3% in the steroid and in the autologous bone marrow groups, respectively (p < 0.05).

Although the overall rates of success of both methods were similar, the steroid group had higher recurrence after a single procedure and required more injections to achieve healing.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 4 | Pages 516 - 520
1 Apr 2007
Bufquin T Hersan A Hubert L Massin P

We used an inverted shoulder arthroplasty in 43 consecutive patients with a mean age of 78 years (65 to 97) who had sustained a three- or four-part fracture of the upper humerus. All except two were reviewed with a mean follow-up of 22 months (6 to 58).

The clinical outcome was satisfactory with a mean active anterior elevation of 97° (35° to 160°) and a mean active external rotation in abduction of 30° (0° to 80°). The mean Constant and the mean modified Constant scores were respectively 44 (16 to 69) and 66% (25% to 97%). Complications included three patients with reflex sympathetic dystrophy, five with neurological complications, most of which resolved, and one with an anterior dislocation. Radiography showed peri-prosthetic calcification in 36 patients (90%), displacement of the tuberosities in 19 (53%) and a scapular notch in ten (25%). Compared with conventional hemiarthroplasty, satisfactory mobility was obtained despite frequent migration of the tuberosities. However, long-term results are required before reverse shoulder arthroplasty can be recommended as a routine procedure in complex fractures of the upper humerus in the elderly.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 5 | Pages 617 - 623
1 May 2010
McNamara I Deshpande S Porteous M

The clinical and radiological results of 50 consecutive acetabular reconstructions in 48 patients using impaction grafting have been retrospectively reviewed. A 1:1 mixture of frozen, ground irradiated bone graft and Apapore 60, a synthetic bone graft substitute, was used in all cases. There were 13 complex primary and 37 revision procedures with a mean follow-up of five years (3.4 to 7.6). The clinical survival rate was 100%, with improvements in the mean Harris Hip Scores for pain and function. Radiologically, 30 acetabular grafts showed evidence of incorporation, ten had radiolucent lines and two acetabular components migrated initially before stabilising.

Acetabular reconstruction in both primary and revision surgery using a 1:1 mixture of frozen, ground, irriadiated bone and Apapore 60 appears to be a reliable method of managing acetabular defects. Longer follow-up will be required to establish whether this technique is as effective as using fresh-frozen allograft.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 3 | Pages 329 - 334
1 Mar 2010
Cox G Einhorn TA Tzioupis C Giannoudis PV

Biochemical markers of bone-turnover have long been used to complement the radiological assessment of patients with metabolic bone disease. Their implementation in daily clinical practice has been helpful in the understanding of the pathogenesis of osteoporosis, the selection of the optimal dose and the understanding of the progression of the onset and resolution of treatment. Since they are derived from both cortical and trabecular bone, they reflect the metabolic activity of the entire skeleton rather than that of individual cells or the process of mineralisation.

Quantitative changes in skeletal-turnover can be assessed easily and non-invasively by the measurement of bone-turnover markers. They are commonly subdivided into three categories; 1) bone-resorption markers, 2) osteoclast regulatory proteins and 3) bone-formation markers. Because of the rapidly accumulating new knowledge of bone matrix biochemistry, attempts have been made to use them in the interpretation and characterisation of various stages of the healing of fractures. Early knowledge of the individual progress of a fracture could help to avoid delayed or nonunion by enabling modification of the host’s biological response.

The levels of bone-turnover markers vary throughout the course of fracture repair with their rates of change being dependent on the size of the fracture and the time that it will take to heal. However, their short-term biological variability, the relatively low bone specificity exerted, given that the production and destruction of collagen is not limited to bone, as well as the influence of the host’s metabolism on their concentration, produce considerable intra- and inter-individual variability in their interpretation. Despite this, the possible role of bone-turnover markers in the assessment of progression to union, the risks of delayed or nonunion and the impact of innovations to accelerate fracture healing must not be ignored.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 12 | Pages 1575 - 1578
1 Dec 2009
Jaiswal PK Macmull S Bentley G Carrington RWJ Skinner JA Briggs TWR

Smoking is known to have an adverse effect on wound healing and musculoskeletal conditions. This case-controlled study looked at whether smoking has a deleterious effect in the outcome of autologous chondrocyte implantation for the treatment of full thickness chondral defects of the knee.

The mean Modified Cincinatti Knee score was statistically significantly lower in smokers (n = 48) than in non-smokers (n = 66) both before and after surgery (p < 0.05). Smokers experienced significantly less improvement in the knee score two years after surgery (p < 0.05). Graft failures were only seen in smokers (p = 0.016). There was a strong negative correlation between the number of cigarettes smoked and the outcome following surgery (Pearson’s correlation coefficient −0.65, p = 0.004).

These results suggest that patients who smoke have worse pre-operative function and obtain less benefit from this procedure than non-smokers. The counselling of patients undergoing autologous chondrocyte implantation should include smoking, not only as a general cardiopulmonary risk but also because poorer results can be expected in smokers following this procedure.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 12 | Pages 1561 - 1565
1 Dec 2009
Blakey CM Eswaramoorthy VK Hamilton LC Biant LC Field RE

We report the minimum five-year follow-up of 352 primary total hip replacements using the uncemented hydroxyapatite-coated ANCA-Fit femoral component with a modular neck and head. The series comprised 319 patients (212 men, 107 women) with a mean age at operation of 64.4 years (28 to 97). The principal diagnosis was osteoarthritis. A total of 18 patients (21 hips) died before their follow-up at five years, nine patients (11 hips) were lost to follow-up, and four (four hips) declined further follow-up. Patient-reported outcomes have been recorded for 288 patients (316 hips).

Their mean Oxford Hip Score improved significantly from 41 points (16 to 57) pre-operatively to 20 points (12 to 44) at five-year follow-up. Radiological assessment showed good bony stability in 98% of implants. There were two cases of aseptic loosening of the femoral component. There were no clinical or radiological complications related to modularity. In our series we did not see the high rate of intra-operative fracture previously reported for this implant.

This medium-term follow-up study demonstrates that the clinical outcome of the ANCA-Fit femoral component is, to date, comparable with that of other metaphyseal loading femoral components.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 5 | Pages 677 - 683
1 May 2005
Calvo E Granizo JJ Fernández-Yruegas D

We prospectively evaluated 61 patients treated arthroscopically for anterior instability of the shoulder at a mean follow-up of 44.5 months (24 to 100) using the Rowe scale. Those with post-operative dislocation or subluxation were considered to be failures. Logistic regression analysis was used to identify patients at increased risk of recurrence in order to develop a suitable selection system.

The mean Rowe score improved from 45 pre-operatively to 86 at follow-up (p < 0.001). At least one episode of post-operative instability occurred in 11 patients (18%), although their stability improved (p = 0.018), and only three required revision. Subjectively, eight patients were dissatisfied. Age younger than 28 years, ligamentous laxity, the presence of a fracture of the glenoid rim involving more than 15% of the articular surface, and post-operative participation in contact or overhead sports were associated with a higher risk of recurrence, and scored 1, 1, 5 and 1 point, respectively. Those patients with a total score of two or more points had a relative risk of recurrence of 43% and should be treated by open surgery.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 9 | Pages 1188 - 1196
1 Sep 2007
Hobby J Griffin D Dunbar M Boileau P

A systematic search of the literature published between January 1985 and February 2006 identified 62 studies which reported the results of arthroscopic procedures for chronic anterior shoulder instability or comparisons between arthroscopic and open surgery. These studies were classified by surgical technique and research methodology, and when appropriate, were included in a meta-analysis.

The failure rate of arthroscopic shoulder stabilisation using staples or transglenoid suture techniques appeared to be significantly higher than that of either open surgery or arthroscopic stabilisation using suture anchors or bio-absorbable tacks. Arthroscopic anterior stabilisation using the most effective techniques has a similar rate of failure to open stabilisation after two years.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 5 | Pages 687 - 692
1 May 2010
Giotakis N Panchani SK Narayan B Larkin JJ Al Maskari S Nayagam S

We have carried out a retrospective review of 20 patients with segmental fractures of the tibia who had been treated by circular external fixation. We describe the heterogeneity of these fractures, their association with multiple injuries and the need for multilevel stability with the least compromise of the biology of the fracture segments. The assessment of outcome included union, complications, the measurement of the functional IOWA knee and ankle scores and the general health status (Short-form 36).

The mean time to union was 21.7 weeks (12.8 to 31), with no difference being observed between proximal and distal levels of fracture. Complications were encountered in four patients. Two had nonunion at the distal level, one a wire-related infection which required further surgery and another shortening of 15 mm with 8° of valgus which was clinically insignificant. The functional scores for the knee and ankle were good to excellent, but the physical component score of the short-form 36 was lower than the population norm. This may be explained by the presence of multiple injuries affecting the overall score.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 1 | Pages 164 - 168
1 Jan 2010
Chen MR Huang JI Victoroff BN Cooperman DR

In an osteological collection of 3100 specimens, 70 were found with unilateral clavicular fractures which were matched with 70 randomly selected normal specimens. This formed the basis of a study of the incidence of arthritis of the acromioclavicular joint and the effect of clavicular fracture on the development of arthritis in the ipsilateral acromioclavicular joint. This was graded visually on a severity scale of 0 to 3. The incidence of moderate to severe arthritis of the acromioclavicular joint in normal specimens was 77% (100 specimens). In those with a clavicular fracture, 66 of 70 (94%) had arthritis of the acromioclavicular joint, compared to 63 of 70 (90%) on the non-injured contralateral side (p = 0.35).

Clavicles with shortening of 15 mm or less had no difference in the incidence of arthritis compared to those with shortening greater than 15 mm (p = 0.25). The location of the fracture had no effect on the development of arthritis.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 2 | Pages 230 - 234
1 Feb 2010
Anderson GA Thomas BP Pallapati SCR

Inability to actively supinate the forearm makes common activities of daily living and certain vocational activities awkward or impossible to perform. A total of 11 patients with deficient supination of the arm underwent transfer of the tendon of flexor carpi ulnaris to the split tendon of brachioradialis with its bony insertion into the radial styloid left intact. Active supination beyond neutral rotation was a mean of 37.2° (25° to 49.5°) at a minimum follow-up of three years, representing a significant improvement (95% confidence interval 25 to 50, p < 0.001). Functional evaluation of the hand after this transfer showed excellent and good results in ten patients and fair in one.

The split tendon of brachioradialis as an insertion for transfer of the flexor carpi ulnaris appears to provide adequate supination of the forearm without altering the available pronation and avoids the domination of wrist extension sometimes associated with transfers of the flexor carpi ulnaris to the radial extensors of the wrist.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 1 | Pages 9 - 15
1 Jan 2007
Beaulé PE Harvey N Zaragoza E Le Duff MJ Dorey FJ

Because the femoral head/neck junction is preserved in hip resurfacing, patients may be at greater risk of impingement, leading to abnormal wear patterns and pain. We assessed femoral head/neck offset in 63 hips undergoing metal-on-metal hip resurfacing and in 56 hips presenting with non-arthritic pain secondary to femoroacetabular impingement. Most hips undergoing resurfacing (57%; 36) had an offset ratio ≤ 0.15 pre-operatively and required greater correction of offset at operation than the rest of the group. In the non-arthritic hips the mean offset ratio was 0.137 (0.04 to 0.23), with the offset ratio correlating negatively to an increasing α angle. An offset ratio ≤ 0.15 had a 9.5-fold increased relative risk of having an α angle ≥ 50.5°. Most hips undergoing resurfacing have an abnormal femoral head/neck offset, which is best assessed in the sagittal plane.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 2 | Pages 298 - 303
1 Feb 2010
Toom A Suutre S Märtson A Haviko T Selstam G Arend A

We have developed an animal model to examine the formation of heterotopic ossification using standardised muscular damage and implantation of a beta-tricalcium phosphate block into a hip capsulotomy wound in Wistar rats. The aim was to investigate how cells originating from drilled femoral canals and damaged muscles influence the formation of heterotopic bone. The femoral canal was either drilled or left untouched and a tricalcium phosphate block, immersed either in saline or a rhBMP-2 solution, was implanted. These implants were removed at three and 21 days after the operation and examined histologically, histomorphometrically and immunohistochemically.

Bone formation was seen in all implants in rhBMP-2-immersed, whereas in those immersed in saline the process was minimal, irrespective of drilling of the femoral canals. Bone mineralisation was somewhat greater in the absence of drilling with a mean mineralised volume to mean total volume of 18.2% (sd 4.5) versus 12.7% (sd 2.9, p < 0.019), respectively.

Our findings suggest that osteoinductive signalling is an early event in the formation of ectopic bone. If applicable to man the results indicate that careful tissue handling is more important than the prevention of the dissemination of bone cells in order to avoid heterotopic ossification.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 2 | Pages 267 - 272
1 Feb 2010
Abdel-Ghani H Ebeid W El-Barbary H

We describe the management of nonunion combined with limb-length discrepancy following vascularised fibular grafting for the reconstruction of long-bone defects in the lower limb after resection of a tumour in skeletally immature patients. We operated on nine patients with a mean age of 13.1 years (10.5 to 14.5) who presented with a mean limb-length discrepancy of 7 cm (4 to 9) and nonunion at one end of a vascularised fibular graft, which had been performed previously, to reconstruct a bone defect after resection of an osteosarcoma.

Reconstruction was carried out using a ring fixator secured with correction by half pins of any malalignment, compression of the site of nonunion and lengthening through a metaphyseal parafocal osteotomy without bone grafting. The expected limb-length discrepancy at maturity was calculated using the arithmetic method. Solid union and the intended leg length were achieved in all the patients. Excessive scarring and the distorted anatomy from previous surgery in these patients required other procedures to be performed with minimal exposures and dissection in order to avoid further compromise to the vascularity of the graft or damage to neurovascular structures. The methods which we chose were simple and effective in addressing these complex problems.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 1 | Pages 66 - 71
1 Jan 2007
Suh KT Lee SS Kim SJ Kim YK Lee JS

The scoliosis observed in chickens after pinealectomy resembles that seen in humans with an adolescent idiopathic scoliosis, suggesting that melatonin deficiency may be responsible. However, to date there have been no studies of pineal gland glucose metabolism in patients with adolescent idiopathic scoliosis that might support this hypothesis.

We examined the excretion of urinary 6-sulfatoxyl-melatonin as well as the glucose metabolism of the pineal gland in 14 patients with an adolescent idiopathic scoliosis and compared them with those of 13 gender-matched healthy controls using F-18 fluorodeoxyglucose brain positron emission tomography. There was no significant difference in the level of urinary 6-sulfatoxyl-melatonin or pineal gland metabolism between the study and the control group. We conclude that permanent melatonin deficiency is not a causative factor in the aetiology of adolescent idiopathic scoliosis.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 5 | Pages 693 - 700
1 May 2010
Makki D Alnajjar HM Walkay S Ramkumar U Watson AJ Allen PW

We carried out a retrospective review of 47 intra-articular fractures of the calcaneum treated by open reduction and internal fixation in 45 patients by a single surgeon between 1993 and 2001. The fractures were evaluated before operation by plain radiographs and a CT scan using Sanders’ classification. Osteosynthesis involved a lateral approach and the use of the AO calcaneal plate. The mean follow-up was for ten years (7 to 15). Clinical assessment included the American Orthopaedic Foot and Ankle Society Score (AOFAS), the Creighton-Nebraska Score, the Kerr, Prothero, Atkins Score and the SF-36 Health Questionnaire. The radiological evaluation consisted of lateral and axial views of the os calcis. Arthritic changes in the subtalar joint were assessed with an internal oblique view and were graded using the Morrey and Wiedeman scale.

There were 18 excellent (38.3%), 17 good (36.2%), three fair (6.3%) and nine poor (19.2%) results. Five patients had a superficial wound infection and five others eventually had a subtalar arthrodesis because of continuing pain. Restoration of Böhler’s angle was associated with a better outcome. The degree of arthritic change in the subtalar joint did not correlate with the outcome scores or Sanders’ classification. Prompt osteosynthesis should be considered for intra-articular fractures of the calcaneum in order to restore the shape of the hindfoot and Böhler’s angle.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 3 | Pages 356 - 361
1 Mar 2010
Kwon Y- Glyn-Jones S Simpson DJ Kamali A McLardy-Smith P Gill HS Murray DW

The presence of pseudotumours, which are soft-tissue masses relating to the hip, after metal-on-metal hip resurfacing arthroplasty has been associated with elevated levels of metal ions in serum, suggesting that pseudotumours occur when there is increased wear. We aimed to quantify the wear in vivo of implants revised for pseudotumours (eight) and of a control group of implants (22) revised for other reasons of failure.

We found that the implant group with pseudotumours had a significantly higher rate of median linear wear of the femoral component at 8.1 μm/year (2.75 to 25.4) than the 1.79 μm/year (0.82 to 4.15; p = 0.002) of the non-pseudotumour group. For the acetabular component a significantly higher rate of median linear wear of 7.36 μm/year (1.61 to 24.9) was observed in the pseudotumour group compared with 1.28 μm/year (0.81 to 3.33, p = 0.001) in the other group. Wear of the acetabular component in the pseudotumour group always involved the edge of the implant, indicating that edge-loading had occurred.

Our findings are the first direct evidence that pseudotumour is associated with increased wear at the metal-on-metal articulation. Furthermore, edge-loading with the loss of fluid-film lubrication may be an important mechanism of generation of wear in patients with a pseudotumour.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 3 | Pages 448 - 453
1 Mar 2010
Benson RT McDonnell SM Knowles HJ Rees JL Carr AJ Hulley PA

The aim of this study was to investigate the occurrence of tissue hypoxia and apoptosis at different stages of tendinopathy and tears of the rotator cuff.

We studied tissue from 24 patients with eight graded stages of either impingement (mild, moderate and severe) or tears of the rotator cuff (partial, small, medium, large and massive) and three controls. Biopsies were analysed using three immunohistochemical techniques, namely antibodies against HIF-1α (a transcription factor produced in a hypoxic environment), BNip3 (a HIF-1α regulated pro-apoptotic protein) and TUNEL (detecting DNA fragmentation in apoptosis).

The HIF-1α expression was greatest in mild impingement and in partial, small, medium and large tears. BNip3 expression increased significantly in partial, small, medium and large tears but was reduced in massive tears. Apoptosis was increased in small, medium, large and massive tears but not in partial tears.

These findings reveal evidence of hypoxic damage throughout the spectrum of pathology of the rotator cuff which may contribute to loss of cells by apoptosis. This provides a novel insight into the causes of degeneration of the rotator cuff and highlights possible options for treatment.