1 Jan 2014
Solomon LB Hofstaetter JG Bolt MJ Howie DW

We investigated the detailed anatomy of the gluteus maximus, gluteus medius and gluteus minimus and their neurovascular supply in 22 hips in 11 embalmed adult Caucasian human cadavers. This led to the development of a surgical technique for an extended posterior approach to the hip and pelvis that exposes the supra-acetabular ilium and preserves the glutei during revision hip surgery. Proximal to distal mobilisation of the gluteus medius from the posterior gluteal line permits exposure and mobilisation of the superior gluteal neurovascular bundle between the sciatic notch and the entrance to the gluteus medius, enabling a wider exposure of the supra-acetabular ilium. This technique was subsequently used in nine patients undergoing revision total hip replacement involving the reconstruction of nine Paprosky 3B acetabular defects, five of which had pelvic discontinuity. Intra-operative electromyography showed that the innervation of the gluteal muscles was not affected by surgery. Clinical follow-up demonstrated good hip abduction function in all patients. These results were compared with those of a matched cohort treated through a Kocher–Langenbeck approach. Our modified approach maximises the exposure of the ilium above the sciatic notch while protecting the gluteal muscles and their neurovascular bundle.

Cite this article: Bone Joint J 2014;96-B:48–53.


The Bone & Joint Journal
Vol. 95-B, Issue 1 | Pages 31 - 37
1 Jan 2013
Zywiel MG Brandt J Overgaard CB Cheung AC Turgeon TR Syed KA

Symptomatic cobalt toxicity from a failed total hip replacement is a rare but devastating complication. It has been reported following revision of fractured ceramic components, as well as in patients with failed metal-on-metal articulations. Potential clinical findings include fatigue, weakness, hypothyroidism, cardiomyopathy, polycythaemia, visual and hearing impairment, cognitive dysfunction, and neuropathy. We report a case of an otherwise healthy 46-year-old patient, who developed progressively worsening symptoms of cobalt toxicity beginning approximately six months following synovectomy and revision of a fractured ceramic-on-ceramic total hip replacement to a metal-on-polyethylene bearing. The whole blood cobalt levels peaked at 6521 µg/l. The patient died from cobalt-induced cardiomyopathy. Implant retrieval analysis confirmed a loss of 28.3 g mass of the cobalt–chromium femoral head as a result of severe abrasive wear by ceramic particles embedded in the revision polyethylene liner. Autopsy findings were consistent with heavy metal-induced cardiomyopathy.

We recommend using new ceramics at revision to minimise the risk of wear-related cobalt toxicity following breakage of ceramic components.

Cite this article: Bone Joint J 2013;95-B:31–7.


The Bone & Joint Journal
Vol. 96-B, Issue 10 | Pages 1333 - 1338
1 Oct 2014
Gustke KA Golladay GJ Roche MW Jerry GJ Elson LC Anderson CR

The aim of this prospective multicentre study was to report the patient satisfaction after total knee replacement (TKR), undertaken with the aid of intra-operative sensors, and to compare these results with previous studies. A total of 135 patients undergoing TKR were included in the study. The soft-tissue balance of each TKR was quantified intra-operatively by the sensor, and 18 (13%) were found to be unbalanced. A total of 113 patients (96.7%) in the balanced group and 15 (82.1%) in the unbalanced group were satisfied or very satisfied one year post-operatively (p = 0.043).

A review of the literature identified no previous study with a mean level of satisfaction that was greater than the reported level of satisfaction of the balanced TKR group in this study. Ensuring soft-tissue balance by using intra-operative sensors during TKR may improve satisfaction.

Cite this article: Bone Joint J 2014;96-B:1333–8


The Bone & Joint Journal
Vol. 96-B, Issue 11 | Pages 1491 - 1497
1 Nov 2014
Howells NR Salmon L Waller A Scanelli J Pinczewski LA

The aim of this study was to examine the functional outcome at ten years following lateral closing wedge high tibial osteotomy for medial compartment osteoarthritis of the knee and to define pre-operative predictors of survival and determinants of functional outcome.

164 consecutive patients underwent high tibial osteotomy between 2000 and 2002. A total of 100 patients (100 knees) met the inclusion criteria and 95 were available for review at ten years. Data were collected prospectively and included patient demographics, surgical details, long leg alignment radiographs, Western Ontario and McMaster Universities osteoarthritis index (WOMAC) and Knee Society scores (KSS) pre-operatively and at five and ten years follow-up.

At ten years, 21 patients had been revised at a mean of five years. Overall Kaplan–Meier survival was 87% (95% confidence interval (CI) 81 to 94) and 79% (95% CI 71 to 87) at five and ten years, respectively. When compared with unrevised patients, those who had been revised had significantly lower mean pre-operative WOMAC Scores (47 (21 to 85) vs 65 (32 to 99), p < 0.001), higher mean age (54 yrs (42 to 61) vs 49 yrs (26 to 66), p = 0.006) and a higher mean BMI (30.2; 25 to 39 vs 27.9; 21 to 36, p = 0.005). Each were found to be risk factors for revision, with hazard ratios of 10.7 (95% CI 4 to 28.6; pre-operative WOMAC < 45), 6.5 (95% CI 2.4 to 17.7; age > 55) and 3.0 (95%CI 1.2 to 7.6; BMI > 30). Survival of patients with pre-operative WOMAC > 45, age < 55 and BMI < 30 was 97% at five and ten years. WOMAC and KSS in surviving patients improved significantly between pre-operative (mean 61; 32 to 99) and five (mean 88; 35 to 100, p = 0.001) and ten years (mean 84; 38 to 100, p = 0.001). Older patients had better functional outcomes overall, despite their higher revision rate.

This study has shown that improved survival is associated with age < 55 years, pre-operative WOMAC scores > 45 and, a BMI < 30. In patients over 55 years of age with adequate pre-operative functional scores, survival can be good and functional outcomes can be significantly better than their younger counterparts. We recommend the routine use of pre-operative functional outcome scores to guide decision-making when considering suitability for high tibial osteotomy.

Cite this article: Bone Joint J 2014;96-B:1491–7.


The Bone & Joint Journal
Vol. 96-B, Issue 1 | Pages 82 - 87
1 Jan 2014
Duquin TR Jacobson JA Schleck CD Larson DR Sanchez-Sotelo J Morrey BF

Treatment of an infected total elbow replacement (TER) is often successful in eradicating or suppressing the infection. However, the extensor mechanism may be compromised by both the infection and the surgery. The goal of this study was to assess triceps function in patients treated for deep infection complicating a TER. Between 1976 and 2007 a total of 217 TERs in 207 patients were treated for infection of a TER at our institution. Superficial infections and those that underwent resection arthroplasty were excluded, leaving 93 TERs. Triceps function was assessed by examination and a questionnaire. Outcome was measured using the Mayo Elbow Performance Score (MEPS).

Triceps weakness was identified in 51 TERs (49 patients, 55%). At a mean follow-up of five years (0.8 to 34), the extensor mechanism was intact in 13 patients, with the remaining 38 having bone or soft-tissue loss. The mean MEPS was 70 points (5 to 100), with a mean functional score of 18 (0 to 25) of a possible 25 points.

Infection following TER can often be eradicated; however, triceps weakness occurs in more than half of the patients and may represent a major functional problem.

Cite this article: Bone Joint J 2014;96-B:82–7.


The Bone & Joint Journal
Vol. 95-B, Issue 11_Supple_A | Pages 53 - 56
1 Nov 2013
Su EP Barrack RL

Cementless femoral stems are currently preferred for total hip replacement (THR) in the United States. Improvements in stem design, instrumentation and surgical technique have made this technology highly successful, reproducible, and applicable to the vast majority of patients requiring a THR. However, there are ongoing developments in some aspects of stem design that influence clinical results, the incidence of complications and their inherent adaptability in accommodating the needs of individual patients. Here we examine some of these design features.

Cite this article: Bone Joint J 2013;95-B, Supple A:53–6.


The Bone & Joint Journal
Vol. 95-B, Issue 11_Supple_A | Pages 74 - 76
1 Nov 2013
Kamath AF McAuliffe CL Gutsche JT Kosseim LM Hume EL Baldwin KD Kornfield Z Israelite CL

Patient safety is a critical issue in elective total joint replacement surgery. Identifying risk factors that might predict complications and intensive care unit (ICU) admission proves instrumental in reducing morbidity and mortality. The institution’s experience with risk stratification and pre-operative ICU triage has resulted in a reduction in unplanned ICU admissions and post-operative complications after total hip replacement. The application of the prediction tools to total knee replacement has proven less robust so far. This work also reviews areas for future research in patient safety and cost containment.

Cite this article: Bone Joint J 2013;95-B, Supple A:74–6.


The Bone & Joint Journal
Vol. 96-B, Issue 10 | Pages 1378 - 1384
1 Oct 2014
Weiser L Korecki MA Sellenschloh K Fensky F Püschel K Morlock MM Rueger JM Lehmann W

It is becoming increasingly common for a patient to have ipsilateral hip and knee replacements. The inter-prosthetic (IP) distance, the distance between the tips of hip and knee prostheses, has been thought to be associated with an increased risk of IP fracture. Small gap distances are generally assumed to act as stress risers, although there is no real biomechanical evidence to support this.

The purpose of this study was to evaluate the influence of IP distance, cortical thickness and bone mineral density on the likelihood of an IP femoral fracture.

A total of 18 human femur specimens were randomised into three groups by bone density and cortical thickness. For each group, a defined IP distance of 35 mm, 80 mm or 160 mm was created by choosing the appropriate lengths of component. The maximum fracture strength was determined using a four-point bending test.

The fracture force of all three groups was similar (p = 0.498). There was a highly significant correlation between the cortical area and the fracture strength (r = 0.804, p <  0.001), whereas bone density showed no influence.

This study suggests that the IP distance has little influence on fracture strength in IP femoral fractures: the thickness of the cortex seems to be the decisive factor.

Cite this article: Bone Joint J 2014;96-B:1378–84.


Bone & Joint 360
Vol. 2, Issue 6 | Pages 34 - 36
1 Dec 2013

The December 2013 Research Roundup360 looks at: Inflammation implicated in FAI; Ponseti and effective teaching; Unicompartmental knee design and tibial strain; Bisphosphonates and fracture healing; Antibiosis in cement; Zoledronic acid improves primary stability in revision?; Osteoporotic fractures revisited; and electroarthrography for monitoring of cartilage degeneration


The Bone & Joint Journal
Vol. 95-B, Issue 12 | Pages 1656 - 1661
1 Dec 2013
Kraal T van der Heide HJL van Poppel BJ Fiocco M Nelissen RGHH Doets HC

Little is known about the long-term outcome of mobile-bearing total ankle replacement (TAR) in the treatment of end-stage arthritis of the ankle, and in particular for patients with inflammatory joint disease. The aim of this study was to assess the minimum ten-year outcome of TAR in this group of patients.

We prospectively followed 76 patients (93 TARs) who underwent surgery between 1988 and 1999. No patients were lost to follow-up. At latest follow-up at a mean of 14.8 years (10.7 to 22.8), 30 patients (39 TARs) had died and the original TAR remained in situ in 28 patients (31 TARs). The cumulative incidence of failure at 15 years was 20% (95% confidence interval (CI) 11 to 28). The mean American Orthopaedic Foot and Ankle Society (AOFAS) ankle–hindfoot score of the surviving patients at latest follow-up was 80.4 (95% CI 72 to 88). In total, 21 patients (23 TARs) underwent subsequent surgery: three implant exchanges, three bearing exchanges and 17 arthrodeses. Neither design of TAR described in this study, the LCS and the Buechel–Pappas, remains currently available. However, based both on this study and on other reports, we believe that TAR using current mobile-bearing designs for patients with end-stage arthritis of the ankle due to inflammatory joint disease remains justified.

Cite this article: Bone Joint J 2013;95-B:1656–61.


Bone & Joint Research
Vol. 2, Issue 6 | Pages 102 - 111
1 Jun 2013
Patel RA Wilson RF Patel PA Palmer RM

Objectives

To review the systemic impact of smoking on bone healing as evidenced within the orthopaedic literature.

Methods

A protocol was established and studies were sourced from five electronic databases. Screening, data abstraction and quality assessment was conducted by two review authors. Prospective and retrospective clinical studies were included. The primary outcome measures were based on clinical and/or radiological indicators of bone healing. This review specifically focused on non-spinal orthopaedic studies.


The Bone & Joint Journal
Vol. 95-B, Issue 11_Supple_A | Pages 3 - 6
1 Nov 2013
Wassef AJ Schmalzried TP

A modular femoral head–neck junction has practical advantages in total hip replacement. Taper fretting and corrosion have so far been an infrequent cause of revision. The role of design and manufacturing variables continues to be debated. Over the past decade several changes in technology and clinical practice might result in an increase in clinically significant taper fretting and corrosion. Those factors include an increased usage of large diameter (36 mm) heads, reduced femoral neck and taper dimensions, greater variability in taper assembly with smaller incision surgery, and higher taper stresses due to increased patient weight and/or physical activity. Additional studies are needed to determine the role of taper assembly compared with design, manufacturing and other implant variables.

Cite this article: Bone Joint J 2013;95-B, Supple A:3–6.


Bone & Joint 360
Vol. 3, Issue 4 | Pages 19 - 21
1 Aug 2014

The August 2014 Wrist & Hand Roundup360 looks at: Trapeziectomy superior to arthrodesis;Tamoxifen beneficial in the short term; Semi-occlusive dressing “the bee’s knees” even with exposed bone; “Open” a relative concept in the hand and wrist; Editorial decisions pushing up standards of reporting; Ulnar variance revisited; Traditionalists are traditional; Diabetes not so bad with carpal tunnel


Bone & Joint 360
Vol. 3, Issue 4 | Pages 21 - 23
1 Aug 2014

The August 2014 Shoulder & Elbow Roundup360 looks at: Myofibroblasts perhaps not implicated in post-traumatic elbow stiffness; olecranon tip biomechanically sound for coranoid reconstruction; obesity and elbow replacement don’t mix; single column plating successful for extra-articular distal humeral fractures; satisfaction not predictable in frozen shoulder; tenodesis and repair both acceptable in Grade II SLAP tears; glenoid bone grafting is effective and glenohumeral articular lesions best seen with an arthroscope.


The Bone & Joint Journal
Vol. 95-B, Issue 10 | Pages 1402 - 1405
1 Oct 2013
Parker M Cawley S Palial V

A consecutive series of 320 patients with an intracapsular fracture of the hip treated with a dynamic locking plate (Targon Femoral Neck (TFN)) were reviewed. All surviving patients were followed for a minimum of two years. During the follow-up period 109 patients died.

There were 112 undisplaced fractures, of which three (2.7%) developed nonunion or re-displacement and five (4.5%) developed avascular necrosis of the femoral head. Revision to an arthroplasty was required for five patients (4.5%). A further six patients (5.4%) had elective removal of the plate and screws.

There were 208 displaced fractures, of which 32 (15.4%) developed nonunion or re-displacement and 23 (11.1%) developed avascular necrosis. A further four patients (1.9%) developed a secondary fracture around the TFN. Revision to a hip replacement was required for 43 patients (20.7%) patients and a further seven (3.3%) had elective removal of the plate and screws.

It is suggested that the stronger distal fixation combined with rotational stability may lead to a reduced incidence of complications related to the healing of the fracture when compared with other contemporary fixation devices but this needs to be confirmed in further studies.

Cite this article: Bone Joint J 2013;95-B:1402–5.


The Bone & Joint Journal
Vol. 96-B, Issue 8 | Pages 1106 - 1110
1 Aug 2014
Malhotra R Kiran Kumar GN K. Digge V Kumar V

Giant cell tumour is the most common aggressive benign tumour of the musculoskeletal system and has a high rate of local recurrence. When it occurs in proximity to the hip, reconstruction of the joint is a challenge. Options for reconstruction after wide resection include the use of a megaprosthesis or an allograft-prosthesis composite. We performed a clinical and radiological study to evaluate the functional results of a proximal femoral allograft-prosthesis composite in the treatment of proximal femoral giant cell tumour after wide resection. This was an observational study, between 2006 and 2012, of 18 patients with a mean age of 32 years (28 to 42) and a mean follow-up of 54 months (18 to 79). We achieved excellent outcomes using Harris Hip Score in 13 patients and a good outcome in five. All allografts united. There were no complications such as infection, failure, fracture or resorption of the graft, or recurrent tumour. Resection and reconstruction of giant cell tumours with proximal femoral allograft–prosthesis composite is a better option than using a prosthesis considering preservation of bone stock and excellent restoration of function.

A good result requires demanding bone banking techniques, effective measures to prevent infection and stability at the allograft-host junction.

Cite this article: Bone Joint J 2014; 96-B:1106–10.


The Bone & Joint Journal
Vol. 96-B, Issue 9 | Pages 1227 - 1233
1 Sep 2014
Phillips JRA Hopwood B Arthur C Stroud R Toms AD

A small proportion of patients have persistent pain after total knee replacement (TKR). The primary aim of this study was to record the prevalence of pain after TKR at specific intervals post-operatively and to ascertain the impact of neuropathic pain. The secondary aim was to establish any predictive factors that could be used to identify patients who were likely to have high levels of pain or neuropathic pain after TKR.

A total of 96 patients were included in the study. Their mean age was 71 years (48 to 89); 54 (56%) were female. The mean follow-up was 46 months (39 to 51). Pre-operative demographic details were recorded including a Visual Analogue Score (VAS) for pain, the Hospital Anxiety and Depression score as well as the painDETECT score for neuropathic pain. Functional outcome was assessed using the Oxford Knee score.

The mean pre-operative VAS was 5.8 (1 to 10); and it improved significantly at all time periods post-operatively (p < 0.001): (from 4.5 at day three to five (1 to 10), 3.2 at six weeks (0 to 9), 2.4 at three months (0 to 7), 2.0 at six months (0 to 9), 1.7 at nine months (0 to 9), 1.5 at one year (0 to 8) and 2.0 at mean 46 months (0 to 10)). There was a high correlation (r > 0.7; p < 0.001) between the mean VAS scores for pain and the mean painDETECT scores at three months, one year and three years post-operatively. There was no correlation between the pre-operative scores and any post-operative scores at any time point.

We report the prevalence of pain and neuropathic pain at various intervals up to three years after TKR. Neuropathic pain is an underestimated problem in patients with pain after TKR. It peaks at between six weeks and three-months post-operatively. However, from these data we were unable to predict which patients are most likely to be affected.

Cite this article: Bone Joint J 2014;96-B:1227–33.


Bone & Joint Research
Vol. 3, Issue 10 | Pages 289 - 296
1 Oct 2014
van IJsseldijk EA Harman MK Luetzner J Valstar ER Stoel BC Nelissen RGHH Kaptein BL

Introduction

Wear of polyethylene inserts plays an important role in failure of total knee replacement and can be monitored in vivo by measuring the minimum joint space width in anteroposterior radiographs. The objective of this retrospective cross-sectional study was to compare the accuracy and precision of a new model-based method with the conventional method by analysing the difference between the minimum joint space width measurements and the actual thickness of retrieved polyethylene tibial inserts.

Method

Before revision, the minimum joint space width values and their locations on the insert were measured in 15 fully weight-bearing radiographs. These measurements were compared with the actual minimum thickness values and locations of the retrieved tibial inserts after revision.


The Bone & Joint Journal
Vol. 95-B, Issue 11 | Pages 1474 - 1479
1 Nov 2013
Tsang SJ Gaston P

Total hip replacement (THR) has been shown to be a cost-effective procedure. However, it is not risk-free. Certain conditions, such as diabetes mellitus, are thought to increase the risk of complications. In this study we have evaluated the prevalence of diabetes mellitus in patients undergoing THR and the associated risk of adverse operative outcomes. A meta-analysis and systematic review were conducted according to the guidelines of the meta-analysis of observational studies in epidemiology. Inclusion criteria were observational studies reporting the prevalence of diabetes in the study population, accompanied by reports of at least one of the following outcomes: venous thromboembolic events; acute coronary events; infections of the urinary tract, lower respiratory tract or surgical site; or requirement for revision arthroplasty. Altman and Bland’s methods were used to calculate differences in relative risks. The prevalence of diabetes mellitus was found to be 5.0% among patients undergoing THR, and was associated with an increased risk of established surgical site infection (odds ratio (OR) 2.04 (95% confidence interval (CI) 1.52 to 2.76)), urinary infection (OR 1.43 (95% CI 1.33 to 1.55)) and lower respiratory tract infections (OR 1.95 (95% CI 1.61 to 2.26)). Diabetes mellitus is a relatively common comorbidity encountered in THR. Diabetic patients have a higher rate of developing both surgical site and non-surgical site infections following THR.

Cite this article: Bone Joint J 2013;95-B:1474–9.


The Bone & Joint Journal
Vol. 95-B, Issue 12 | Pages 1603 - 1609
1 Dec 2013
Chana R Facek M Tilley S Walter WK Zicat B Walter WL

We report the clinical and radiological outcomes of a series of contemporary cementless ceramic-on-ceramic total hip replacements (THRs) at ten years in patients aged ≤ 55 years of age. Pre- and post-operative activity levels are described. A total of 120 consecutive ceramic cementless THRs were performed at a single centre in 110 patients from 1997 to 1999. The mean age of the patients at operation was 45 years (20 to 55). At ten years, four patients had died and six were lost to follow-up, comprising ten hips. The mean post-operative Harris hip score was 94.7 (55 to 100). Radiological analysis was undertaken in 90 available THRs of the surviving 106 hips at final review: all had evidence of stable bony ingrowth, with no cases of osteolysis. Wear was undetectable. There were four revisions. The survival for both components with revision for any cause as an endpoint was 96.5% (95% confidence interval 94.5 to 98.7). The mean modified University of California, Los Angeles activity level rose from a mean of 6.4 (4 to 10) pre-operatively to 9.0 (6 to 10) at the ten-year post-operative period.

Alumina ceramic-on-ceramic bearings in cementless primary THR in this series have resulted in good clinical and radiological outcomes with undetectable rates of wear and excellent function in the demanding younger patient group at ten years.