Advertisement for orthosearch.org.uk
Results 1861 - 1880 of 2601
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 5 | Pages 680 - 685
1 Jul 2001
Bowditch M Villar R

Early failures have seen titanium fall from favour as a material for cemented femoral stems. Between 1989 and 1994, we performed a prospective review of a consecutive series of 122 cemented total hip replacements using the Ultima straight textured titanium stem, and report the five- to ten-year clinical and radiological outcomes. There were no revisions for loosening of the femoral stem. Revision surgery was undertaken for other reasons such as dislocation, infection and loosening of the cup in 7.3%. Of those patients without revision all but two were satisfied with their hip, with 74% graded good or excellent using a modified Harris hip score. Radiological assessment revealed probable loosening in two. Although slight vertical subsidence was found in one-third of patients it had not progressed to loosening. It is not clear whether this represents debonding. Non-progressive radiolucent lines (1 to 2 mm) were present in zone 1 at the cement-prosthesis interface in 14.7%. Calcar resorption and hypertrophy around the distal stem were not often seen. With 97% survival at a mean of 7.5 years, the medium-term results of this specific cemented titanium stem are reassuring so far, but we are concerned about debonding and future failure


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 4 | Pages 550 - 554
1 Jul 1996
Hui ACW Heras-Palou C Dunn I Triffitt PD Crozier A Imeson J Gregg PJ

We performed a prospective, randomised controlled trial in 177 patients who were having either total hip or knee replacement, to evaluate the use of both above- and below-knee graded compression stockings in the prevention of deep-vein thrombosis (DVT). With above-knee stockings, we found no significant reduction of the overall, proximal or major calf (> 5 cm) DVT rates. With below-knee stockings, the overall thrombosis rate was similar to that of the control group but the stockings appeared to have altered the pattern of thrombosis. Patients who had total hip replacement and wore below-knee stockings had a significantly higher rate of proximal or major calf DVT (p = 0.03). This pattern was reversed in patients with total knee replacement who developed a significantly lower rate of proximal or major calf DVT with below-knee stockings (p < 0.05). Our results showed that, with the exception of below-knee stockings in knee replacement patients, graded compression stockings were ineffective in preventing DVT after hip or knee replacement surgery


The Bone & Joint Journal
Vol. 99-B, Issue 6 | Pages 766 - 773
1 Jun 2017
Graves SE de Steiger R Davidson D Donnelly W Rainbird S Lorimer MF Cashman KS Vial RJ

Aims

Femoral stems with exchangeable (modular) necks were introduced to offer surgeons an increased choice when determining the version, offset and length of the femoral neck during total hip arthroplasty (THA). It was hoped that this would improve outcomes and reduce complications, particularly dislocation. In 2010, the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) first reported an increased rate of revision after primary THA using femoral stems with an exchangeable neck. The aim of this study was to provide a more comprehensive up-to-date analysis of primary THA using femoral stems with exchangeable and fixed necks.

Materials and Methods

The data included all primary THA procedures performed for osteoarthritis (OA), reported to the AOANJRR between 01 September 1999 and 31 December 2014. There were 9289 femoral stems with an exchangeable neck and 253 165 femoral stems with a fixed neck. The characteristics of the patients and prostheses including the bearing surface and stem/neck metal combinations were examined using Cox proportional hazard ratios (HRs) and Kaplan-Meier estimates of survivorship.


Bone & Joint 360
Vol. 6, Issue 1 | Pages 10 - 13
1 Feb 2017


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 3 | Pages 439 - 443
1 May 1994
Johnsson R Franzen H Nilsson L

From 1970 to 1980 cemented metal-on-plastic total hip replacement was performed on 799 hips with primary osteoarthritis using one surgical technique. At the 10- to 20-year follow-up there had been 97 revisions for mechanical loosening. Univariate survivorship analysis showed that an increased risk of revision was associated with male gender, young age at primary THR, the Brunswik and Lubinus snap-fit prostheses with large femoral heads (as compared with the Charnley prosthesis), and varying experience of the surgeon. Multivariate statistical analysis showed a three-fold increased risk of revision for men (p < 0.0001), an increase in relative risk of 1.8 per 10 years younger at surgery (p < 0.0001), a fivefold increase in risk for the Brunswik prosthesis (p < 0.0001) and a twofold increase for the Lubinus prosthesis (p = 0.0067). Inexperience of the surgeon, however, was not validated as a risk factor. The study shows that the true risk factors for revision can be identified accurately by combining univariate survivorship and multivariate statistical analyses


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 1 | Pages 7 - 10
1 Jan 1991
Bogoch E Ouellette G Hastings D

We reviewed the records and radiographs from 10 hospitals to identify 50 patients with rheumatoid arthritis (RA) who had sustained 52 femoral neck fractures. Most patients were female (88%), elderly (mean age 66 years) and had had severe polyarticular disease for a mean duration of 16 years. Over half had taken systemic corticosteroids, nearly all were severely osteopenic but few had rheumatoid changes in the hip. Of the 20 fractures treated by internal fixation 12 had complications including nonunion (5), osteonecrosis (5), infection (1), and intertrochanteric fracture (1). Only one of the nine undisplaced fractures required reoperation, but seven of the 11 displaced fractures had revision surgery. Twenty fractures were treated by primary total hip arthroplasty with only one early complication. The other 12 fractures had been treated by hemiarthroplasty (9), hip excision (1) or non-operatively (2). Our results suggest that, in elderly rheumatoid patients, severely displaced femoral neck fractures should be treated by total hip replacement


The Journal of Bone & Joint Surgery British Volume
Vol. 65-B, Issue 4 | Pages 502 - 506
1 Aug 1983
Whyte W Bailey P Hamblen D Fisher W Kelly I

A comparison was made in a laminar-flow operating room between total-body exhaust gowns and a clothing system made from Fabric 450. This disposable clothing was found to be much more comfortable and convenient than the total-body exhaust gowns. The average airborne bacterial counts obtained during total hip replacement operations from each of the clothing systems were identical when the downflow method of ventilation was used (0.7 per cubic metre) and no significant difference could be demonstrated when the crossflow system was used (2.2 per cubic metre with the total-body exhaust gowns and 3.1 per cubic metre with the disposable clothing). Tests in a dispersal chamber were carried out to find the effectiveness of each item of the disposable clothing in reducing bacterial dispersion. These tests demonstrated the relative ineffectiveness of wearing a surgical gown as compared with wearing the complete system. It was confirmed bacteriologically that the downflow system of ventilation was more efficient than the crossflow type; the importance of this observation with respect to clothing and sepsis is discussed in this paper


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 5 | Pages 802 - 808
1 Sep 1996
Britton AR Murray DW Bulstrode CJ McPherson K Denham RA

We reviewed the records of the long-term outcome of 208 Charnley and 982 Stanmore total hip replacements (THR) performed by or under the supervision of one surgeon from 1973 to 1987. The Stanmore implant had a better survival rate before revision at 14 years (86% to 79%, p = 0.004), but the difference only became apparent at ten years. The later Stanmore implants did better than the early ones (97% to 92% at ten years, p = 0.005), the improvement coinciding with the introduction of a new cementing technique using a gun. Most of the Charnley implants were done before most of the Stanmore implants so that the difference between the results may in part be explained by improved methods, but this is not the complete explanation since a difference persisted for implants carried out during the same period of time. We conclude that improved techniques have reduced failure rates substantially. This improvement was much greater than that observed between these two designs of implant. Proof of the difference would require a very large randomised controlled trial over a ten-year period


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 2 | Pages 177 - 182
1 Mar 2001
Taylor AH Shannon M Whitehouse SL Lee MB Learmonth ID

We describe the results of 76 total arthroplasties of the hip for stage-III or stage-IV avascular necrosis of the femoral head. Harris Galante Porous cups were used in 63 patients between 1986 and 1994 and followed prospectively. We reviewed 70 hips with a follow-up of more than five years (mean 7.6). At the latest review the mean Harris Hip Score had improved from a preoperative value of 29 ± 14.7 to 94 ± 6.8. Radiologically, there was no evidence of acetabular migration. The rate of revision for the femoral component was 8.6%, three being undertaken for loosening and three to allow downsizing of the femoral head. The rate of revision for the acetabular component was 7.1% (five cups). At the time of revision none of the cups was clinically loose, and only required the liner to be changed. The rate of complications was low with no case of deep infection or dislocation, but nine of the 76 hips (11.8%) showed grade-III heterotopic ossification. Previous studies of patients undergoing cemented total hip arthroplasty for the treatment of advanced avascular necrosis have indicated a high incidence of loosening of the acetabular component. Our findings show good medium-term results using the Harris Galante Porous cup for acetabular reconstruction, together with a variety of cemented femoral components, for the treatment of this difficult problem


The Bone & Joint Journal
Vol. 99-B, Issue 7 | Pages 917 - 920
1 Jul 2017
Bloch BV Shah A Snape SE Boswell TCJ James PJ

Aims

Infection following total hip or knee arthroplasty is a serious complication. We noted an increase in post-operative infection in cases carried out in temporary operating theatres. We therefore compared those cases performed in standard and temporary operating theatres and examined the deep periprosthetic infection rates.

Patients and methods

A total of 1223 primary hip and knee arthroplasties were performed between August 2012 and June 2013. A total of 539 (44%) were performed in temporary theatres. The two groups were matched for age, gender, body mass index and American Society of Anesthesiologists grade.


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 2 | Pages 273 - 280
1 Mar 1999
Krismer M Biedermann R Stöckl B Fischer M Bauer R Haid C

We report the ten-year results for three designs of stem in 240 total hip replacements, for which subsidence had been measured on plain radiographs at regular intervals. Accurate migration patterns could be determined by the method of Einzel-Bild-Roentgen-Analyse-femoral component analysis (EBRA-FCA) for 158 hips (66%). Of these, 108 stems (68%) remained stable throughout, and five (3%) started to migrate after a median of 54 months. Initial migration of at least 1 mm was seen in 45 stems (29%) during the first two years, but these then became stable. We revised 17 stems for aseptic loosening, and 12 for other reasons. Revision for aseptic loosening could be predicted by EBRA-FCA with a sensitivity of 69%, a specificity of 80%, and an accuracy of 79% by the use of a threshold of subsidence of 1.5 mm during the first two years. Similar observations over a five-year period allowed the long-term outcome to be predicted with an accuracy of 91%. We discuss the importance of four different patterns of subsidence and confirm that the early measurement of migration by a reasonably accurate method can help to predict long-term outcome. Such methods should be used to evaluate new and modified designs of prosthesis


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 4 | Pages 711 - 719
1 Jul 1998
Sugano N Noble PC Kamaric E Salama JK Ochi T Tullos HS

We studied the morphometry of 35 femora from 31 female patients with developmental dysplasia of the hip (DDH) and another 15 from 15 age- and sex-matched control patients using CT and three-dimensional computer reconstruction models. According to the classification of Crowe et al 15 of the dysplastic hips were graded as class I (less than 50% subluxation), ten as class II/III (50% to 100% subluxation) and ten as class IV (more than 100% subluxation). The femora with DDH had 10 to 14° more anteversion than the control group independent of the degree of subluxation of the hip. In even the most mildly dysplastic joints, the femur had a smaller and more anteverted canal than the normal control. With increased subluxation, additional abnormalities were observed in the size and position of the femoral head. Femora from dislocated joints had a short, anteverted neck associated with a smaller, narrower, and straighter canal than femora of classes I and II/III or the normal control group. We suggest that when total hip replacement is performed in the patient with DDH, the femoral prosthesis should be chosen on the basis of the severity of the subluxation and the degree of anteversion of each individual femur


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 5 | Pages 681 - 687
1 Sep 1993
Soballe K Toksvig-Larsen S Gelineck J Fruensgaard S Hansen E Ryd L Lucht U Bunger C

We allocated randomly 27 patients undergoing 28 primary uncemented total hip replacements (THR) to receive prosthetic components of similar design with either plasma-sprayed titanium alloy (Ti) coating (n = 13) or hydroxyapatite (HA) coating (n = 15). After some exclusions, 15 of the patients (15 THR; 7 with HA- and 8 with Ti-coating) were followed by roentgen stereophotogrammetric analysis at 3, 6 and 12 months to measure migration of the femoral component. Twenty-six of the patients (26 THR) were followed clinically and by conventional radiography. All the femoral components had migrated at 3 months. From 3 to 12 months, the migration of Ti-coated components continued whereas the HA-coated components had stabilised. At 12 months there was significantly less migration of the HA-coated components (p < 0.05). The maximum subsidence was 0.2 mm in both groups. The Harris hip score was equal in the two groups preoperatively but at follow-up it was better in the HA-coated group (p < 0.05) and visual analogue scale scores showed that they had less pain (p < 0.05)


Bone & Joint Research
Vol. 6, Issue 8 | Pages 506 - 513
1 Aug 2017
Sims AL Farrier AJ Reed MR Sheldon TA

Objectives

The objective of this study was to assess all evidence comparing the Thompson monoblock hemiarthroplasty with modular unipolar implants for patients requiring hemiarthroplasty of the hip with respect to mortality and complications.

Methods

A literature search was performed to identify all relevant literature. The population consisted of patients undergoing hemiarthroplasty of the hip for fracture. The intervention was hemiarthroplasty of the hip with a comparison between Thompson and modular unipolar prostheses.

Pubmed, Embase, CINAHL, Web of Science, PROSPERO and the Cochrane Central Register of Controlled Trials.

The study designs included were randomised controlled trials (RCTs), well designed case control studies and retrospective or prospective cohort studies. Studies available in any language, published at any time until September 2015 were considered. Studies were included if they contained mortality or complications.


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 1 | Pages 59 - 65
1 Jan 2002
Nozawa M Shitoto K Matsuda K Maezawa K Kurosawa H

Between 1986 and 1990, we carried out 55 rotational acetabular osteotomies in 54 patients with acetabular dysplasia. Five hips were lost to follow-up. Of the 50 remaining, the degenerative changes were classified according to the criteria of Tönnis as grade 0 in 23, grade 1 in 16 and grade 2 in 11. The mean age of the three men and 46 women at the time of operation was 31.8 years (13 to 53). The mean follow-up was 137 months (120 to 174). At the most recent follow-up, 48 patients had satisfactory relief from pain. There was a slight decrease in the range of movement, particularly of flexion, in 18 hips. Radiologically, all osteotomies had united satisfactorily. There was radiological evidence of improvement in degenerative changes in 13 hips (5 grade 1 and 8 grade 2). Ten deteriorated (5 grade 0, 3 grade 1, and 2 grade 2) and one required total hip arthroplasty ten years after osteotomy. The osteoarthritis in the two hips with an associated valgus osteotomy progressed. The changes in radiological indices such as the centre-edge angle, acetabular femoral head index, acetabular root obliquity and horizontal or vertical displacement of the femoral head showed no statistical difference (unpaired Student’s t-test) between the patients with radiological progression and those with and without improvement


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 6 | Pages 876 - 886
1 Aug 2004
Albinana J Dolan LA Spratt KF Morcuende J Meyer MD Weinstein SL

Untreated acetabular dysplasia following treatment for developmental dysplasia of the hip (DDH) leads to early degenerative joint disease. Clinicians must accurately and reliably recognise dysplasia in order to intervene appropriately with secondary acetabular or femoral procedures. This study sought early predictors of residual dysplasia in order to establish empirically-based indications for treatment. DDH treated by closed or open reduction alone was reviewed. Residual hip dysplasia was defined according to the Severin classification at skeletal maturity. Future hip replacement in a subset of these patients was compared with the Severin classification. Serial measurements of acetabular development and subluxation of the femoral head were collected, as were the age at reduction, type of reduction, and Tonnis grade prior to reduction. These variables were used to predict the Severin classification. The mean age at reduction in 72 hips was 16 months (1 to 46). On the final radiograph, 47 hips (65%) were classified as Severin I/II, and 25 as Severin III/IV (35%). At 40 years after reduction, five of 43 hips (21%) had had a total hip replacement (THR). The Severin grade was predictive for THR. Early measurements of the acetabular index (AI) were predictive for Severin grade. For example, an AI of 35° or more at two years after reduction was associated with an 80% probability of becoming a Severin grade III/IV hip. This study links early acetabular remodelling, residual dysplasia at skeletal maturity and the long-term risk of THR. It presents evidence describing the diagnostic value of early predictors of residual dysplasia, and therefore, of the long-term risk of degenerative change


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 4 | Pages 665 - 669
1 Jul 1997
Verdonschot N Huiskes R

It has been suggested that the endurance of cemented femoral reconstructions in total hip arthroplasty is affected by the creep of acrylic cement, but it is not known to what extent cement creeps under loading conditions in vivo, or how this affects load transfer. We have simulated the long-term creep properties of acrylic cement in finite-element models of femoral stem constructs and analysed their effects. We investigated whether subsidence rates measured in vivo could be explained by creep of acrylic cement, and if polished, unbonded, stems accommodated creep better than bonded stems. Our findings showed that polished prostheses subsided only about 50 μm as a result of cement creep. The long-term prosthetic subsidence rates caused by creep of acrylic cement are therefore very small and do not explain the excessive migration rates which have sometimes been reported. Cement creep did, however, relax cement stresses and create a more favourable stress distribution at the interfaces. These trends were found around both the bonded and unbonded stems. Our results did not confirm that polished, unbonded, stems accommodated creep better than bonded stems in terms of cement and interface stress patterns


The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 1 | Pages 45 - 55
1 Jan 1987
Engh C Bobyn J Glassman A

Total hip replacement using porous-coated cobalt-chrome femoral implants designed for biological fixation has been evaluated in 307 patients after two years and in 89 patients after five years. Histological study of 11 retrieved specimens showed bone ingrowth in nine and fibrous tissue fixation in two. Fixation by bone ingrowth occurred in 93% of the cases in which a press fit of the stem at the isthmus was achieved, but in only 69% of those without a press fit. The clinical results at two years were excellent. The incidence of pain and limp was much lower when there was either a press fit of the stem or radiographic evidence of bone ingrowth. Factors such as age, sex, and the disease process did not influence the clinical results. Most cases showed only slight resorptive remodelling of the upper femur, but in a few cases with a larger, more rigid stem, more extensive bone loss occurred. The results after five years showed no deterioration with time. Fixation by the ingrowth of bone or of fibrous tissue both appeared to be stable, but bone ingrowth gave better clinical results


The Journal of Bone & Joint Surgery British Volume
Vol. 62-B, Issue 4 | Pages 502 - 505
1 Nov 1980
Rooker G Wilkinson J

A prospective study of allergic contact dermatitis after metal-on-plastic total hip replacement was undertaken in 69 patients, of whom 54 were available for review after operation. Before operation six patients were metal sensitive, but only one remained so afterwards; this patient had given a clear history of metal sensitivity and a titanium prosthesis had therefore been used. In all six patients the result of the operation was good and no case of loosening occurred. Sixty-three patients had negative patch tests before operation; in none of these was metal sensitivity detected after operation. Cutaneous sensitivity to various metals is well documented after the insertion of metal-on-metal prostheses and in failed prostheses. We have not found any such increased sensitivity after metal-on-plastic hip replacement. There is little evidence of a direct causal relationship between metal sensitivity and subsequent loosening. The cutaneous sensitivity may be the consequence of loosening rather than its cause. Our results suggest that, providing metal-on-plastic prostheses are used, routine patch testing before hip replacement is no longer required


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 6 | Pages 899 - 902
1 Nov 1996
Weale AE Newman P Ferguson IT Bannister GC

Nerve injury is a rare complication of total hip replacement which may be related to the exposure used for the operation. The posterior approach is traditionally associated with injury to the sciatic nerve. We have compared the incidence of nerve injury after primary total hip replacement (THR) using either a posterior or a direct lateral approach. We studied 42 consecutive patients undergoing primary total hip replacement. The surgeons used a posterior (22 patients) or direct lateral (20 patients) approach in accordance with their normal practice. The obturator, femoral, posterior tibial and common peroneal nerves were assessed clinically and electrophysiologically by electromyography (EMG) and measurement of the velocity of nerve conduction before operation and at four weeks after. All patients were free from symptoms of nerve injury after operation but five lesions were identified in four patients by the electrophysiological studies; the obturator nerve was involved in two, the femoral in one, the common peroneal in one and the posterior tibial in one. All these injuries occurred using the lateral approach. Clinical assessment alone underestimates the incidence of nerve injury complicating THR. Our study does not confirm the association of nerve injury with the posterior approach which had been described previously