Advertisement for orthosearch.org.uk
Results 1801 - 1820 of 2601
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 5 | Pages 746 - 751
1 Nov 1987
Saito M Saito S Ohzono K Ono K

We have followed up a series of total hip arthroplasties performed for secondary osteoarthritis and analysed the results in relation to the osteoblastic response to the disease. This was assessed pre-operatively from the radiographic appearance, according to Bombelli's criteria (1983). Of 63 hips in 55 patients followed up for five to 13 years, 17 were hypertrophic, 24 normotrophic and 22 atrophic in type. The atrophic-type hips showed a high incidence of acetabular loosening, leading to unsatisfactory clinical results in 32%. By contrast, the hypertrophic-type hips had a low incidence of acetabular loosening, while the normotrophic type showed intermediate results. It was concluded that the osteoblastic response to osteoarthritis is closely related to acetabular loosening and to late clinical failure


The Journal of Bone & Joint Surgery British Volume
Vol. 68-B, Issue 5 | Pages 770 - 774
1 Nov 1986
Mjoberg B Selvik G Hansson L Rosenqvist R Onnerfalt R

Twenty patients were examined by standard radiography and roentgen stereophotogrammetric analysis (RSA) during a two-year period after total hip arthroplasty. Eleven of the acetabular components migrated cranially and three femoral components migrated distally. This migration was most rapid during the first four months after operation. Our findings support the possibility that mechanical loosening is initiated by thermal injury during polymerisation of the cement; the less frequent migration of the metallic femoral component compared with the polyethylene acetabular component may be because the metal acts as a heat sink. Standard radiographs were inadequate for assessment of early mechanical loosening, whereas RSA could reveal migration within four months of the arthroplasty


The Journal of Bone & Joint Surgery British Volume
Vol. 66-B, Issue 2 | Pages 180 - 183
1 Mar 1984
Nutton R Checketts R

A series of 167 patients with Charnley-type total hip replacements were studied retrospectively to determine the incidence of trochanteric non-union, the degree of postoperative trochanteric displacement, and the relation between these two complications. The power in the hip abductor muscles, measured with a load-cell device, was significantly reduced if the trochanteric fragment had displaced proximally by more than 3 cm; 12% of those studied fell into this group and, as a consequence, had a poorer result. It was concluded that displacement of the trochanter was of greater importance than bony union in determining function in the replaced hip. Because these unwanted problems may compromise an otherwise successful operation, it is suggested tentatively that trochanteric osteotomy should be abandoned except for difficult primary operations or for revision procedures


Bone & Joint 360
Vol. 7, Issue 1 | Pages 15 - 17
1 Feb 2018


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 3 | Pages 363 - 365
1 Apr 2003
Fleming P Lenehan B O’Rourke S McHugh P Kaar K McCabe JP

Injuries to the sciatic nerve are an occasional complication of surgery to the hip and acetabulum, and traction is frequently the causative mechanism. In vitro and animal experiments have shown that increased tensile strain on peripheral nerves, when applied for prolonged periods, impairs nerve function. We have used video-extensometry to measure strain on the human sciatic nerve during total hip replacement (THR). Ten consecutive patients with a mean age of 72 years undergoing primary THR by the posterior approach were recruited, and strains in the sciatic nerve were measured in different combinations of flexion and extension of the hip and knee, before dislocation of the hip. Significant increases (p = 0.02) in strain in the sciatic nerve were observed in flexion of the hip and extension of the knee. The mean increase was 26% (19% to 30%). In animal studies increases of this magnitude have been shown to impair electrophysiological function in peripheral nerves. Our results suggest that excessive flexion of the hip and extension of the knee should be avoided during THR


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 3 | Pages 378 - 382
1 Apr 2000
McNally SA Shepperd JAN Mann CV Walczak JP

We describe the clinical and radiological outcome of 100 consecutive total hip replacements in 86 patients using the JRI Furlong hydroxyapatite-coated femoral component. The follow-up was 100% at a mean of ten years (9.0 to 12.0). All 54 living patients (62 hips) were examined annually. Their mean Merle d’Aubigné score was 5.8/5.6/4.6. A total of 32 patients had died. Their notes at the last annual assessment recorded a similar outcome to that of the living patients. Radiographs showed no radiolucent lines around any femoral component and there were no signs of impending failure. One patient required excision arthroplasty, but the femoral component had been bonded satisfactorily. There have been no other revisions of femoral components. Our findings suggest that the hydroxyapatite coating gives a satisfactory prosthesis-bone interface which is preferable to any other system


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 2 | Pages 297 - 303
1 Mar 2000
Ramaniraka NA Rakotomanana LR Leyvraz P

After cemented total hip arthroplasty (THA) there may be failure at either the cement-stem or the cement-bone interface. This results from the occurrence of abnormally high shear and compressive stresses within the cement and excessive relative micromovement. We therefore evaluated micromovement and stress at the cement-bone and cement-stem interfaces for a titanium and a chromium-cobalt stem. The behaviour of both implants was similar and no substantial differences were found in the size and distribution of micromovement on either interface with respect to the stiffness of the stem. Micromovement was minimal with a cement mantle 3 to 4 mm thick but then increased with greater thickness of the cement. Abnormally high micromovement occurred when the cement was thinner than 2 mm and the stem was made of titanium. The relative decrease in surface roughness augmented slipping but decreased debonding at the cement-bone interface. Shear stress at this site did not vary significantly for the different coefficients of cement-bone friction while compressive and hoop stresses within the cement increased slightly


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 1 | Pages 45 - 51
1 Jan 2003
Skinner JA Todo S Taylor M Wang JS Pinskerova V Scott G

We have compared the survival and radiological outcome at ten years after total hip replacement using two techniques for preparing the femoral canal. The same prosthesis was used throughout and all operations were performed by the same surgical team. In technique 1 the canal was over-reamed by 2 mm and in technique 2 it was reamed to the same size as the prosthesis. Technique 1 was performed on 92 patients and technique 2 on 97 patients. The survival at ten years was 97.2% (90.6 to 99.2) for technique 1 and 98.8% (92.9 to 99.8) for technique 2. Vertical migration was greater in technique 1 (1.8 mm versus 1.0 mm at five years; p = 0.36). There were significantly more lytic lesions and radiolucent lines at five years (p = 0.0061) with technique 1. We conclude that technique 2 is not worse and may produce better long- term results than current teaching suggests


The Journal of Bone & Joint Surgery British Volume
Vol. 63-B, Issue 3 | Pages 413 - 416
1 Aug 1981
Wicks M Rich G Ratcliff R Hone M

Effective concentrations of antibiotic in the fluid bathing implanted hip prostheses are essential to prevent infection by micro-organisms. Twenty patients undergoing total hip replacement were given one gram of Cephradine intramuscularly one hour before operation and one other received a single bolus of Cephradine intravenously before operation and one other received a single bolus of Cephradine intravenously before operation. The concentrations of antibiotic were greater and persisted longer in the tissue fluid than in the blood. The antibiotic was sufficient to inhibit most micro-organisms causing contamination. We recommend that Cephradine is given intramuscularly one hour before operation and at six-hourly intervals after operation until the drainage tubes and intravenous lines have been removed


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 1 | Pages 135 - 139
1 Jan 1997
Lerouge S Huk O Yahia L Witvoet J Sedel L

We made a semiquantitative study of the comparative histology of pseudomembranes from 12 loose cemented ceramic-ceramic and 18 metal-polyethylene total hip replacements. We found no significant difference in cellular reaction between the two groups, but there was a major difference in the origin of the particulate debris. In the metal-polyethylene group, polyethylene of articular origin was predominant, while in the ceramic-ceramic group the cellular reaction appeared to be a response to zirconia ceramic particles used to opacify cement used for fixation. Isolation and characterisation of the debris showed that the zirconia particles formed the greatest proportion (76%) in ceramic-ceramic hips, while alumina debris of articular origin formed only 12%. Our study has indicated that aseptic loosening of ceramic cups is not due to a response to debris generated at the articular interface, but to mechanical factors which lead to fragmentation of the cement


The Bone & Joint Journal
Vol. 100-B, Issue 1 | Pages 1 - 3
1 Jan 2018
Skinner JA Haddad FS


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 5 | Pages 796 - 801
1 Sep 1996
Kiss J Murray DW Turner-Smith AR Bithell JF Bulstrode CJ

We studied the migration of 58 cemented Hinek femoral components for total hip replacement,using roentgen stereophotogrammetric analysis over four years. The implants migrated faster during the first year than subsequently, and the pattern of migration in the second period was very different. During the first year they subsided, tilted into varus and internally rotated. After this there was slow distal migration with no change in orientation. None of the prostheses has yet failed. The early migration is probably caused by resorption of bone damaged by surgical trauma or the heat generated by the polymerisation of bone cement. Later migration may be due to creep in the bone cement or the surrounding fibrous membrane. The prosthesis which we studied allows the preservation of some of the femoral neck, and comparison with published migration studies of the Charnley stem suggests that this decreases rotation and may help to prevent loosening


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 4 | Pages 593 - 597
1 May 2001
Kamikawa K Harada Y Nagata K Moriya H

Sterilisation by gamma irradiation in the presence of air causes free radicals generated in polyethylene (PE) to react with oxygen, which could lead to loss of physical properties and reduction in fatigue strength. Tissue retrieved from failed total hip replacements often has large quantities of particulate PE and most particles associated with peri-implant osteolysis are oxidised. Consequently, an understanding of the cellular responses of oxidised PE particles may lead to clarification of the pathogenesis of osteolysis and aseptic loosening. We have used the agarose system to demonstrate the differential effects of oxidised and non-oxidised PE particles on the release of proinflammatory products such as interleukin-1β (IL-1β), IL-6, and tumour necrosis factor-α (TNF-α) from monocytes/ macrophages (M/M). Oxidised PE particles were shown to stimulate human M/M to phagocytose and to release cytokines. Oxidation may alter the surface chemistry of the particles and enhance the response to specific membrane receptors on macrophages, such as scavenger-type receptors


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 3 | Pages 383 - 386
1 May 1990
Heeg M Klasen H Visser J

We report a retrospective study of 54 acetabular fractures treated by open reduction and internal fixation, with an average follow-up of 9.6 years (3 to 17). Reduction leaving displacement of less than or equal to 2 mm was achieved in 36 hips (67%); good or excellent functional results were obtained in 33 patients (61%). Early complications requiring re-operation included postoperative loss of reduction in one case and an intra-articular screw in another. Arthrodesis or total hip arthroplasty had been performed in 10 patients (19%) who had late symptomatic degenerative changes. Failure to obtain accurate reduction was the most important factor leading to a poor result, but heterotopic calcification caused poor results in seven patients, five of whom had had an anatomical reduction


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 4 | Pages 520 - 527
1 Jul 1995
Murray D Carr A Bulstrode C

To assist surgeons to select a total hip replacement (THR) we present comparative information on all such implants on the market in the UK. We identified 62 different primary THRs, manufactured by 19 companies; half had been introduced in the last five years, and only 30% have any results published in peer-reviewed journals. The prices range from 250 pounds to 2000 pounds, and the two cheapest implants have the longest reported follow-up. The number of THR implants available in the UK, and presumably the rest of the world, is rapidly increasing, but there is little or no scientific evidence that the newer, more expensive, implants are better than established designs. Some will undoubtedly be worse. We believe that this situation is unsatisfactory and make recommendations for improvement, in particular that preference be given to implants with good results in published peer-reviewed long-term clinical trials


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 1 | Pages 130 - 134
1 Jan 1999
Alfaro-Adrián J Gill HS Murray DW

Studies using roentgen stereophotogrammetric analysis (RSA) have shown that the femoral components of cemented total hip replacements (THR) migrate distally relative to the bone, but it is not clear whether this occurs at the cement-implant or the cement-bone interface or within the cement mantle. Our aim was to determine where this migration occurred, since this has important implications for the way in which implants function and fail. Using RSA we compared for two years the migration of the tip of the stem with that of the cement restrictor for two different designs of THR, the Exeter and Charnley Elite. We have assumed that if the cement restrictor migrates, then at least part of the cement mantle also migrates. Our results have shown that the Exeter migrates distally three times faster than the Charnley Elite and at different interfaces. With the Exeter migration was at the cement-implant interface whereas with the Charnley Elite there was migration at both the cement-bone and the cement-implant interfaces


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 5 | Pages 728 - 734
1 Sep 1994
Marti R Schuller H van Steijn M

Dysplastic acetabula were augmented during total hip replacement by superolateral autografts. In cases of primary arthroplasty these were taken from the excised femoral head and in revision surgery from the iliac crest. Two or (usually) three small grafts were used to facilitate revascularisation; they were fixed with lag screws to the roughened iliac bone above the acetabulum. We reviewed 84 hips (63 primary arthroplasties and 21 revisions) more than five years (mean 10.1) after operation. All but one of the grafts showed consolidation within three months and they had become structurally integrated with the iliac bone, as evidenced by the trabecular reorientation. Resorption, which has caused early socket failure when large bone grafts have been used, did not occur


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 5 | Pages 706 - 711
1 Jul 2003
Whitehouse SL Lingard EA Katz JN Learmonth ID

We used prospective data from 862 total knee and 716 total hip replacements three years after surgery in order to derive and validate a reduced Western Ontario and McMasters University Osteoarthritis Index (WOMAC) function scale. The reduced scale was derived using the advice of clinical experts as well as analysis of data. The scale was tested for validity, reliability and responsiveness. Items which were retained included: ascending stairs, rising from sitting, walking on the flat, getting in or out of a car, putting on socks, rising from bed, and sitting. The reduced and full scales had comparable, moderate correlations with other measures of function, confirming convergent validity. Cronbach’s alpha was high (α > 0.85) with the reduced scale confirming reliability. Responsiveness was greater for the reduced scale (full = 1.4, reduced = 1.6). This reduced version of the WOMAC function scale provides a practical, valid, reliable and responsive alternative to the full function scale for use after total joint replacement. Further work is needed to demonstrate its wider applicability


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 4 | Pages 616 - 623
1 Jul 1993
Joshi A Porter M Trail I Hunt L Murphy J Hardinge K

We report the long-term outcome of 218 Charnley low-friction arthroplasties in 141 patients who were 40 years old or younger at the time of surgery. The minimum follow-up was ten years with a mean of 16 years. The probability of the femoral component surviving 20 years was 86% and of the acetabular component, 84%. The chance that both components would survive for this period was 75%. The pathological diagnosis significantly influenced implant survival. In rheumatoid patients the probability of both components surviving at 20 years was 96% compared with 51% in patients with osteoarthritis. Clinical assessment of 103 patients (166 hips) in whom the arthroplasty was still functioning showed that 94% of hips had minimal pain or none. We conclude that in young patients cemented total hip replacement is a good procedure for those with rheumatoid arthritis but that the results are much less reliable in those with osteoarthritis


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 2 | Pages 222 - 227
1 Mar 1993
Anwar M Sugano N Matsui M Takaoka K Ono K

We performed Kawamura's dome osteotomy of the pelvis, with simultaneous distal transfer of the greater trochanter on 101 hips in 91 patients with osteoarthritis secondary to hip dysplasia. The mean age at operation was 30 years (15 to 55), and follow-up was for a mean of 8.3 years (5 to 14). Clinical evaluation using the Merle d'Aubigne score showed 92% excellent or good results. Radiologically, 91 hips had good acetabular remodelling and showed no signs of progression of osteoarthritis. In ten hips the osteoarthritic process progressed despite the osteotomy and six of these eventually underwent total hip replacement. Factors which were significantly associated with a poor outcome included an advanced stage of osteoarthritis, valgus deformity of the proximal femur, old age at the time of operation and postoperative persistence of abductor insufficiency