We have followed up a series of
Twenty patients were examined by standard radiography and roentgen stereophotogrammetric analysis (RSA) during a two-year period after
A series of 167 patients with Charnley-type
Injuries to the sciatic nerve are an occasional complication of surgery to the hip and acetabulum, and traction is frequently the causative mechanism. In vitro and animal experiments have shown that increased tensile strain on peripheral nerves, when applied for prolonged periods, impairs nerve function. We have used video-extensometry to measure strain on the human sciatic nerve during
We describe the clinical and radiological outcome of 100 consecutive
After cemented
We have compared the survival and radiological outcome at ten years after
Effective concentrations of antibiotic in the fluid bathing implanted hip prostheses are essential to prevent infection by micro-organisms. Twenty patients undergoing
We made a semiquantitative study of the comparative histology of pseudomembranes from 12 loose cemented ceramic-ceramic and 18 metal-polyethylene
We studied the migration of 58 cemented Hinek femoral components for
Sterilisation by gamma irradiation in the presence of air causes free radicals generated in polyethylene (PE) to react with oxygen, which could lead to loss of physical properties and reduction in fatigue strength. Tissue retrieved from failed
We report a retrospective study of 54 acetabular fractures treated by open reduction and internal fixation, with an average follow-up of 9.6 years (3 to 17). Reduction leaving displacement of less than or equal to 2 mm was achieved in 36 hips (67%); good or excellent functional results were obtained in 33 patients (61%). Early complications requiring re-operation included postoperative loss of reduction in one case and an intra-articular screw in another. Arthrodesis or
To assist surgeons to select a
Studies using roentgen stereophotogrammetric analysis (RSA) have shown that the femoral components of cemented
Dysplastic acetabula were augmented during
We used prospective data from 862 total knee and 716
We report the long-term outcome of 218 Charnley low-friction arthroplasties in 141 patients who were 40 years old or younger at the time of surgery. The minimum follow-up was ten years with a mean of 16 years. The probability of the femoral component surviving 20 years was 86% and of the acetabular component, 84%. The chance that both components would survive for this period was 75%. The pathological diagnosis significantly influenced implant survival. In rheumatoid patients the probability of both components surviving at 20 years was 96% compared with 51% in patients with osteoarthritis. Clinical assessment of 103 patients (166 hips) in whom the arthroplasty was still functioning showed that 94% of hips had minimal pain or none. We conclude that in young patients cemented
We performed Kawamura's dome osteotomy of the pelvis, with simultaneous distal transfer of the greater trochanter on 101 hips in 91 patients with osteoarthritis secondary to hip dysplasia. The mean age at operation was 30 years (15 to 55), and follow-up was for a mean of 8.3 years (5 to 14). Clinical evaluation using the Merle d'Aubigne score showed 92% excellent or good results. Radiologically, 91 hips had good acetabular remodelling and showed no signs of progression of osteoarthritis. In ten hips the osteoarthritic process progressed despite the osteotomy and six of these eventually underwent