Advertisement for orthosearch.org.uk
Results 161 - 180 of 290
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 7 | Pages 1083 - 1083
1 Sep 2000
JONES DHA


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 7 | Pages 1085 - 1085
1 Sep 2000
JONES S ALI F FERNDANDEZ J


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 2 | Pages 160 - 164
1 Mar 2000
Jones DH Dezateux CA Danielsson LG Paton RW Clegg J


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 6 | Pages 991 - 994
1 Nov 1999
Morgan-Jones RL Cross MJ

Thirty cruciate ligaments were retrieved from either cadavers or limbs which had been amputated. Each specimen was sectioned and stained to demonstrate the presence of collagen, nerves and vessels.

All 30 specimens contained an interconnecting band of collagen fibres between the anterior and posterior cruciate ligaments. Vascular structures were present in all specimens and nerve fibres were identified in 26 (86%). We have called this structure the ‘intercruciate band’. The anterior and posterior cruciate ligaments should no longer be thought of in isolation, but together as a ‘cruciate complex’.


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 6 | Pages 1023 - 1028
1 Nov 1999
Williams PR Jones DA Bishay M

Between January 1987 and December 1988 there were 7575 births in the Swansea maternity unit. Of these 823 (10.9%) were considered to be at ‘high risk’ for developmental dysplasia of the hip (DDH). Static ultrasound examination was performed in each case and the results classified on the basis of the method of Graf. A total of 117 type III–IV hips in 83 infants was splinted using the Aberdeen splint.

Radiographs of these hips were taken at six and 12 months. Hilgenreiner’s measurements of the acetabular angle were made in all cases and the development of the femoral capital epiphysis was assessed by measuring the epiphyseal area. The effect of splintage on the acetabular angle and the epiphyseal area between the normal and abnormal splinted hips was compared. Radiographs of 16 normal infants (32 normal unsplinted hips) were used as a control group.

This cohort has now been followed up for a minimum of nine years. There have been no complications as a result of splintage. The failure rate was 1.7% or 0.25 per 1000 live births. No statistical difference was found when comparing the effect of splintage on the acetabular angle and epiphyseal area between normal and abnormal splinted hips and normal unsplinted hips.

Our study has shown that while the Aberdeen splint had a definite but small failure rate, it was safe in that it did not produce avascular necrosis. The current conventional view that a low rate of splintage is always best is therefore brought into question if the Aberdeen splint is chosen for the management of neonatal DDH.


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 4 | Pages 744 - 744
1 Jul 1999
JONES D


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 3 | Pages 560 - 560
1 May 1999
JONES D


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 6 | Pages 943 - 945
1 Nov 1998
Jones D


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 1 | Pages 184 - 184
1 Jan 1998
Jones DHA


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 4 | Pages 576 - 582
1 Jul 1997
Haddad FS Jones DHA Vellodi A Kane N Pitt MC

Children with a mucopolysaccharidosis or mucolipidosis suffer progressive disability of the hands, particularly in relation to dysfunction of the median nerve. This is an increasing problem because bone-marrow transplantation has dramatically improved survival without apparently changing the musculoskeletal manifestations. We have reviewed 48 children with these syndromes who required carpal tunnel decompression, recording symptoms, signs, radiological, electrophysiological and operative findings, histology and upper-limb function. In these children the carpal tunnel syndrome differs from that seen in adults. Symptoms are rare but signs such as decreased sweating, pulp atrophy, thenar wasting and manual clumsiness are much more common. At operation, the flexor retinaculum was thickened and a mass of white tenosynovium engulfed the flexor tendons. Most patients had some definite nerve constriction with a thickened epineurium.

Functional improvement was seen after early decompression, with some benefit from simultaneous tendon release. Regular physiotherapy helped to maintain increased hand movement.

We describe our assessment protocol, the physiotherapy and operative regime and the standard functional review which helps to maximise function in the hands and upper limbs of these children.


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 3 | Pages 471 - 476
1 May 1996
Haidar RK Jones RS Vergroesen DA Evans GA

We have studied retrospectively 37 hips in 36 children at an average of 91 months after simultaneous open reduction and Salter innominate osteotomy for developmental hip dysplasia. At the latest review 97.3% were clinically and 83.8% radiologically good or excellent. In three hips (8%) there were signs of avascular necrosis, but only one had been symptomatic. There were no cases of recurrent posterior displacement.


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 4 | Pages 640 - 644
1 Jul 1995
Li P Jones N Gregg P

The early diagnosis of aseptic loosening of a total hip replacement by plain radiography, scintigraphy and arthrography has been shown to be unreliable. It has been suggested that it may be possible to distinguish between a secure and a loose prosthesis using a vibration technique. We have assessed the use of this technique in vitro using models of early and late loosening. Late loosening with an unstable prosthesis can be reliably detected by vibration analysis, but this method was shown to have a very poor diagnostic sensitivity in early loosening when there is no obvious prosthetic instability.


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 3 | Pages 435 - 438
1 May 1995
Chissell H Jones J

We performed a retrospective study of the factors affecting the outcome of Weber type-C ankle fractures in 43 patients reviewed at two to nine years after injury. We determined the functional result in relation to the use of a diastasis screw, the accuracy of reduction, the presence of tibiotalar dislocation, and of injury to the medial side of the ankle by medial malleolar fracture or deltoid ligament rupture. We assessed the use of a diastasis screw as appropriate or inappropriate on the basis of an anatomical study performed by Boden et al (1989). The diastasis screw was used unnecessarily in 19 of the 31 patients so treated, but this did not appear to affect the final functional result. The worse functional results were in ankles dislocated at the initial injury, and in those with medial malleolar fractures as opposed to those with deltoid ligament ruptures. The best results were after accurate reduction of the fibula and the syndesmosis, and greater increase in the width of the syndesmosis was associated with a worse result. Our results suggest that an increase of more than 1.5 mm in syndesmosis width is unacceptable. We recommend that when the deltoid ligament is ruptured, a diastasis screw should be used if the fibular fracture is more than 3.5 cm above the top of the syndesmosis. When a medial malleolar fracture has been rigidly repaired a diastasis screw is required if the fibular fracture is more than 15 cm above the syndesmosis.


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 1 | Pages 64 - 66
1 Jan 1995
Mohammed A Rahamatalla A Wynne-Jones C


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 1 | Pages 18 - 22
1 Jan 1992
Jones S Pinder I Moran C Malcolm A

Isolated wear of the polyethylene tibial component led to failure in five of a series of 108 uncemented porous-coated knee replacements. The clinical features included pain, effusion and instability with progressive varus deformity. In all cases there was extensive wear on the medial side of the polyethylene surface of the prosthesis. The mechanism of such wear is complex, being due in part to the unconstrained nature of the joint and the incongruity of its surfaces. Other design characteristics may have contributed.


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 6 | Pages 969 - 971
1 Nov 1991
Phelan S Jones D Bishay M

Transverse fractures of the sacrum with neurological complications have been studied in four patients illustrating the following features: diagnosis is often delayed, there are radiological difficulties in making the diagnosis, and the indications for surgery are not well defined. Specific radiographic views are recommended. All the cases presented in this report responded well to conservative management.


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 6 | Pages 884 - 889
1 Nov 1991
Kallio P Lequesne G Paterson D Foster B Jones

We used ultrasonography to study 26 hips with slipped capital femoral epiphyses. In recently slipped epiphyses the ultrasound image revealed a step at the anterior physeal outline (mean 6.4 mm), diminished distance between the anterior acetabular rim and the femoral metaphysis (mean 4.3 mm) and an effusion. As metaphyseal remodelling progressed the physeal step decreased. The femoral neck appeared straighter in hips which had been symptomatic for longer than three weeks. It was possible to measure posterior epiphyseal displacement without projectional errors and the method was accurate in diagnosing minimal slip and in staging displacement. The suggested criteria are, less than 7 mm for a mild slip, 7 to 11 mm for a moderate slip and more than 11 mm for a severe slip. We recommend ultrasonography for the diagnosis, staging and follow-up management of slipped upper femoral epiphysis.


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 5 | Pages 724 - 728
1 Sep 1991
Hardinge K Porter M Jones P Hukins D Taylor C

A computer-based image analysis system has been developed as a research tool in total hip replacement. The system has been programmed to take multiple measurements from coronal plane radiographs. Poor quality radiographic images can be enhanced and standardised. The measurements which can be obtained include stem subsidence, cup migration, cup wear, and stem loosening. Reproducibility and accuracy were +/- 0.01 mm and +/- 0.5 mm respectively. The present application is in retrospective research, but prospective monitoring of radiographs is planned.


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 3 | Pages 487 - 491
1 May 1991
Forbes H Allen P Waller C Jones S Edgar M Webb P Ransford A

Since 1981, during operations for spinal deformity, we have routinely used electrophysiological monitoring of the spinal cord by the epidural measurement of somatosensory evoked potentials (SEPs) in response to stimulation of the posterior tibial nerve. We present the results in 1168 consecutive cases. Decreases in SEP amplitude of more than 50% occurred in 119 patients, of whom 32 had clinically detectable neurological changes postoperatively. In 35 cases the SEP amplitude was rapidly restored, either spontaneously or by repositioning of the recording electrode; they had no postoperative neurological changes. One patient had delayed onset of postoperative symptoms referrable to nerve root lesions without evidence of spinal cord involvement, but there were no false negative cases of intra-operative spinal cord damage. In 52 patients persistent, significant, SEP changes were noted without clinically detectable neurological sequelae. None of the many cases which showed falls in SEP amplitude of less than 50% experienced neurological problems. Neuromuscular scoliosis, the use of sublaminar wires, the magnitude of SEP decrement, and a limited or absent intra-operative recovery of SEP amplitude were identified as factors which increased the risk of postoperative neurological deficit.


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 2 | Pages 216 - 218
1 Mar 1991
Jones D

Ten normal neonatal hips were examined in stillborn babies. At first, forcible Barlow manoeuvres did not produce subluxation or dislocation, but by repeated examination a previously stable joint could be rendered unstable. Dissection of the hips showed that the vacuum fit between the femur and the acetabulum was an important factor in neonatal hip stability. The posterior capsule was not a strong or, in itself, an important structure. It is postulated that the capsule and the labrum act together as 'O' rings to maintain the vacuum fit; it is possible that repeated examinations, by producing an effusion, could break the seal and allow instability.