Advertisement for orthosearch.org.uk
Results 161 - 180 of 397
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 67-B, Issue 5 | Pages 747 - 749
1 Nov 1985
Seth M Khurana J

Ten patients with 13 ankylosed elbows after burns are described. Six elbows, fixed in nearly full extension, had almost total functional disability; the other seven had varying amounts of deformity. In five of the 13 elbows there was a continuous bony mass with loss of the joint space; these were treated by a modified excision arthroplasty which restored good movement and useful function, though there was some lateral laxity. Six elbows had a posterior bony block; this was excised, which restored a useful arc of movement. The literature on bony ankylosis after burns is reviewed and the management of these cases in a developing country is described


The Journal of Bone & Joint Surgery British Volume
Vol. 40-B, Issue 2 | Pages 203 - 207
1 May 1958
Jones V

1. A case of recurrent posterior subluxation of the shoulder is described. After failure of a soft-tissue repair, a posterior bone block operation was performed. 2. The distinction between traumatic dislocations with tearing of the capsule or of the glenoid labrum, and habitual luxations from laxity of the capsule, is emphasised. Although the anterior rim of the glenoid was detached in this case, it is considered to fall into the latter category. 3. A posterior bone block provides a simple and efficient form of repair in this type of case. It is free from the disadvantage of causing limitation of rotation at the shoulder joint; it employs a principle which might well merit more application than at present in the repair of anterior dislocations


Bone & Joint Open
Vol. 1, Issue 7 | Pages 339 - 345
3 Jul 2020
MacDessi SJ Griffiths-Jones W Harris IA Bellemans J Chen DB

Aims

An algorithm to determine the constitutional alignment of the lower limb once arthritic deformity has occurred would be of value when undertaking kinematically aligned total knee arthroplasty (TKA). The purpose of this study was to determine if the arithmetic hip-knee-ankle angle (aHKA) algorithm could estimate the constitutional alignment of the lower limb following development of significant arthritis.

Methods

A matched-pairs radiological study was undertaken comparing the aHKA of an osteoarthritic knee (aHKA-OA) with the mechanical HKA of the contralateral normal knee (mHKA-N). Patients with Grade 3 or 4 Kellgren-Lawrence tibiofemoral osteoarthritis in an arthritic knee undergoing TKA and Grade 0 or 1 osteoarthritis in the contralateral normal knee were included. The aHKA algorithm subtracts the lateral distal femoral angle (LDFA) from the medial proximal tibial angle (MPTA) measured on standing long leg radiographs. The primary outcome was the mean of the paired differences in the aHKA-OA and mHKA-N. Secondary outcomes included comparison of sex-based differences and capacity of the aHKA to determine the constitutional alignment based on degree of deformity.


The Bone & Joint Journal
Vol. 101-B, Issue 6 | Pages 660 - 666
1 Jun 2019
Chalmers BP Limberg AK Athey AG Perry KI Pagnano MW Abdel MP

Aims

There is little literature about total knee arthroplasty (TKA) after distal femoral osteotomy (DFO). Consequently, the purpose of this study was to analyze the outcomes of TKA after DFO, with particular emphasis on: survivorship free from aseptic loosening, revision, or any re-operation; complications; radiological results; and clinical outcome.

Patients and Methods

We retrospectively reviewed 29 patients (17 women, 12 men) from our total joint registry who had undergone 31 cemented TKAs after a DFO between 2000 and 2012. Their mean age at TKA was 51 years (22 to 76) and their mean body mass index 32 kg/m2 (20 to 45). The mean time between DFO and TKA was ten years (2 to 20). The mean follow-up from TKA was ten years (2 to 16). The prostheses were posterior-stabilized in 77%, varus-valgus constraint (VVC) in 13%, and cruciate-retaining in 10%. While no patient had metaphyseal fixation (e.g. cones or sleeves), 16% needed a femoral stem.


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 2 | Pages 297 - 299
1 Mar 1992
O'Driscoll S An K Korinek S Morrey B

We used 11 cadaver elbows and a three-dimensional electromagnetic tracking device to record elbow movements before and after implantation of a 'loose-hinged' elbow prosthesis (modified Coonrad). During simulated active motion there was a maximum of 2.7 degrees (+/- 1.5 degrees) varus/valgus laxity in the cadaver joints. This increased slightly after total elbow arthroplasty to 3.8 degrees (+/- 1.4 degrees). These values are lower than those recorded for the cadaver joints and for the prostheses at the limits of their varus/valgus displacements, indicating that both behave as 'semi-constrained' joints under physiological conditions. They suggest that the muscles absorb some of the forces and moments that in a constrained prosthesis would be transferred to the prosthesis-bone interface


The Journal of Bone & Joint Surgery British Volume
Vol. 63-B, Issue 3 | Pages 399 - 403
1 Aug 1981
Baksi D

Lateral instability of the patella was found after recurrent, habitual and permanent dislocations. Contracture of soft tissues lateral to the patella only occurred with habitual and permanent dislocations, but medial laxity was present in all cases. After adequate release of the lateral contracture, the medial stability was improved by transposition of the lower three-quarters of the pes anserinus to the medial border of the patella, and the patellar ligament. This created a relatively unstretchable physiological sling which ensured dynamic stability of the patella. Six recurrent, 21 habitual and nine permanent dislocations of the patella were treated by this method. Results were excellent in 21 patients, good in 13 and fair in two. The follow-up period varied from 21 to 84 months. There have been no recurrences to date


The Journal of Bone & Joint Surgery British Volume
Vol. 60-B, Issue 3 | Pages 320 - 326
1 Aug 1978
Attenborough C

The stabilised gliding knee prosthesis is a compromise between hinged joints and condylar prostheses. It is a two-piece implant designed to allow normal gliding movements of flexion and extension and which, stabilised by a connecting rod between the femoral and tibial components, allows a designed laxity of rotation and lateral movements. A modification of the original femoral component is described. Two hundred and forty-five knee replacement operations have been done between January 1973 and September 1977 and the results are reported. The results using this prosthesis are at least equal to those using hinged or condylar prostheses. So far there has been no case of spontaneous loosening of the components and the implant can be used in patients who, because of severe deformities and instability, are unsuitable for condylar prostheses


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 3 | Pages 400 - 406
1 May 1995
Kato T

We have developed a method of measuring anterior displacement of the calcaneus on the talus in instability of the subtalar joint and have used the technique to demonstrate anterior instability in 50 patients (72 feet) showing a positive drawer sign. The angle of the posterior facet of the talus was also measured to assess the bony configuration. Our patients with subtalar joint instability could be divided into three categories. The first group had a history of trauma leading to ankle instability (26 cases), the second showed generalised joint laxity (10 cases) and the third were young females with a history of chronic stress on the foot and a poor bony block (14 cases). Satisfactory results were obtained by treating the instability with a brace or by reconstruction of the interosseous talocalcaneal ligament


The Bone & Joint Journal
Vol. 102-B, Issue 8 | Pages 1062 - 1071
1 Aug 2020
Cheung JPY Fong HK Cheung PWH

Aims

To determine the effectiveness of prone traction radiographs in predicting postoperative slip distance, slip angle, changes in disc height, and lordosis after surgery for degenerative spondylolisthesis of the lumbar spine.

Methods

A total of 63 consecutive patients with a degenerative spondylolisthesis and preoperative prone traction radiographs obtained since 2010 were studied. Slip distance, slip angle, disc height, segmental lordosis, and global lordosis (L1 to S1) were measured on preoperative lateral standing radiographs, flexion-extension lateral radiographs, prone traction lateral radiographs, and postoperative lateral standing radiographs. Patients were divided into two groups: posterolateral fusion or posterolateral fusion with interbody fusion.


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 1 | Pages 82 - 87
1 Jan 1994
Jonsson H Elmqvist L Karrholm J Tegner Y

We report a review of 54 patients with chronic anterior cruciate ligament rupture treated by patellar-quadriceps tendon graft augmented with polypropylene braid (Kennedy-LAD). The femoral placement of the graft was randomised to either a modified over-the-top (OTT) or a tunnel position obtained by an isometric drill guide (ISO). At the two-year follow-up both procedures had resulted in improvement of subjective knee function and activity level. Stereoradiographic measurements showed reduction of anteroposterior laxity to near normal in about one-third of the patients, but muscle strength and objective functional performance showed little or no changes. The OTT group had better subjective knee function. We were unable to confirm the theoretical advantages of the use of the drill guide, partly because it provided a tibial tunnel which was too anterior


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 1 | Pages 169 - 172
1 Jan 1998
Jorn LP Fridén T Ryd L Lindstrand A

We obtained simultaneous measurements of sagittal knee laxity in 12 consecutive patients after reconstruction of the anterior cruciate ligament (ACL), using the Stryker laxity tester and radiostereometric analysis (RSA). The mean anteroposterior (AP) displacement when a 90 N load was applied in both directions was 5.3 ± 2.7 mm with RSA and 9.8 ± 1.6 mm with the external device (p < 0.001). The corresponding measurements at a load of 180 N were 5.7 ± 2.4 mm and 13.8 ± 3.7 mm, respectively (p < 0.001). More than 50% of the sagittal knee movement, as measured by the external device at a load of 180 N, was not true femorotibial displacement of the joint but was due to soft-tissue deformation


The Journal of Bone & Joint Surgery British Volume
Vol. 60-B, Issue 3 | Pages 315 - 318
1 Aug 1978
Cavendish M Wright J

This is a preliminary report of the results of knee joint replacements using the Liverpool Mark II knee joint system which consists of a bicondylar prosthesis and a set of stereotactic instruments. The prosthesis has been developed from Gunston's concept, and the special instruments ensure its accurate insertion through meniscectomy-type incisions placed on either side of the patella. Particular features of the prosthesis are near-normal articulation, and the simplicity of the operation. Sixty-two knee replacements were implanted in forty-two patients between the spring of 1974 and January 1977. After the operation fifty-six knees were painless and four others produced only slight pain. Full extension was obtained in fifty-eight knees, and none showed a valgus or varus deformity. Collateral laxity was absent in all knees. There were two failures. These early results are most encouraging


The Journal of Bone & Joint Surgery British Volume
Vol. 59-B, Issue 1 | Pages 15 - 19
1 Feb 1977
Tillberg B

An operation using either the medial or the lateral meniscus to effect the late repair of torn cruciate ligaments is described. Forty-three patients under fifty years of age who were unable to return to their work because of severe joint laxity have been treated in this way and reviewed after one to thirty years. Sagittal stability was measured by a special apparatus, and a comparison was made between normal knees and affected knees before and after operation. The review of forty-five knees showed normal stability in thirty-one, slight instability in twelve and no improvement in two. Forty-one patients had returned to their former work: twenty-two complained of instability when tired; all had pain-free joints. The use of a meniscus for the reconstruction of either cruciate ligament is considered to be simple, safe and effective


Bone & Joint 360
Vol. 8, Issue 6 | Pages 3 - 8
1 Dec 2019
Pulido PG Donell S McNamara I


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 1 | Pages 93 - 96
1 Jan 1999
Bokor DJ Conboy VB Olson C

We studied retrospectively a consecutive series of 547 shoulders in 529 patients undergoing operation for instability. In 41, the cause of instability was considered to be lateral avulsion of the capsule, including the inferior glenohumeral ligament, from the neck of the humerus, the HAGL lesion. In 35, the lesion was found at first exploration, whereas in six it was noted at revision of a previous failed procedure. In both groups, the patients were older on average than those with instability from other causes. Of the primary cases, in 33 (94.3%) the cause of the first dislocation was a violent injury; six (17.4%) had evidence of damage to the rotator cuff and/or the subscapularis. Only four (11.4%) had a Bankart lesion. In patients undergoing a primary operation in whom the cause of the first dislocation was a violent injury, who did not have a Bankart lesion and had no suggestion of multidirectional laxity, the incidence of HAGL was 39%


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 1 | Pages 29 - 32
1 Jan 2001
Hulet CH Locker BG Schiltz D Texier A Tallier E Vielpeau CH

We reviewed 74 partial medial meniscectomies in 57 patients with stable knees, to assess the long-term functional and radiological outcome. The International Knee Documentation Committee score and the residual laxity were assessed in both knees. At the time of surgery the mean age of the patients was 36 ± 11 years and the mean follow-up was 12 ± 1 years. All had a limited medial meniscectomy. The anterior cruciate ligament was intact in all cases. The meniscal tear was vertical in 95% and complex in 5%. The posterior part of the meniscus was removed in 99%. A peripheral rim was preserved in all cases. After 12 years 95% of the patients were satisfied or very satisfied with their knee(s). Objectively, 57% had grade A function and 43% were grade B. The outcome correlated only with the presence of anterior knee pain at final follow-up. In the 49 cases of arthroscopic meniscectomy for which there was a contralateral normal knee there was narrowing of the ‘joint-space’ in 16% of the operated knees. There was no correlation between this and other parameters such as age or different meniscal pathologies


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 4 | Pages 654 - 659
1 Jul 1994
Beard D Dodd C Trundle H Simpson A

We performed a prospective, double-blind, randomised, clinical trial to investigate the efficacy of two regimes of rehabilitation for knees with anterior cruciate ligament deficiency (ACLD). Fifty ACLD patients were randomly allocated to one of two treatment groups: a programme of muscle strengthening (T) or a programme designed to enhance proprioception and improve hamstring contraction reflexes (P). An indirect measure of proprioception, the reflex hamstring contraction latency (RHCL), and a functional scoring system were used to record the status of the knee before and after the 12-week course of physiotherapy. Sagittal knee laxity was also measured. There was improvement in mean RHCL and in the mean functional score in both groups after treatment. The improvement in group P was significantly greater than that in group T. There was no significant change in joint laxity after treatment in either group. In both groups there was a positive correlation between improvement in RHCL and functional gain


The Journal of Bone & Joint Surgery British Volume
Vol. 50-B, Issue 3 | Pages 546 - 550
1 Aug 1968
Thieme WT Wynne-Davies R Blair HAF Bell ET Loraine JA

1. Twenty-one cases of congenital dislocation of the hip were found on examination of 1,881 consecutive neonates on the first day of life, giving an incidence of eleven per 1,000 live births. 2. Insignificant high-pitched "clicks" were noted in 10 per cent of newborn children. 3. Conversion of half of the patients with hip dislocation to normal occurred during the first post-natal week. 4. Joint laxity was not a feature of the newborn with congenital dislocation of the hip. 5. Oestradiol, oestrone and oestriol were estimated in twenty-fourhour urine samples collected from sixteen patients with congenital dislocation of the hip and nineteen matched controls during the first six days of life. No significant differences in oestrogen output between the two groups were found. 6. The hypothesis that congenital dislocation of the hip is a result of an inborn error of oestrogen metabolism in the newborn is not supported


The Bone & Joint Journal
Vol. 102-B, Issue 6 | Pages 677 - 682
1 Jun 2020
Katzouraki G Zubairi AJ Hershkovich O Grevitt MP

Aims

Diagnosis of cauda equina syndrome (CES) remains difficult; clinical assessment has low accuracy in reliably predicting MRI compression of the cauda equina (CE). This prospective study tests the usefulness of ultrasound bladder scans as an adjunct for diagnosing CES.

Methods

A total of 260 patients with suspected CES were referred to a tertiary spinal unit over a 16-month period. All were assessed by Board-eligible spinal surgeons and had transabdominal ultrasound bladder scans for pre- and post-voiding residual (PVR) volume measurements before lumbosacral MRI.


Bone & Joint Research
Vol. 9, Issue 6 | Pages 293 - 301
1 Jun 2020
Hexter AT Hing KA Haddad FS Blunn G

Aims

To evaluate graft healing of decellularized porcine superflexor tendon (pSFT) xenograft in an ovine anterior cruciate ligament (ACL) reconstruction model using two femoral fixation devices. Also, to determine if pSFT allows functional recovery of gait as compared with the preoperative measurements.

Methods

A total of 12 sheep underwent unilateral single-bundle ACL reconstruction using pSFT. Two femoral fixation devices were investigated: Group 1 (n = 6) used cortical suspensory fixation (Endobutton CL) and Group 2 (n = 6) used cross-pin fixation (Stratis ST). A soft screw was used for tibial fixation. Functional recovery was quantified using force plate analysis at weeks 5, 8, and 11. The sheep were euthanized after 12 weeks and comprehensive histological analysis characterized graft healing at the graft-bone interface and the intra-articular graft (ligamentization).