We have investigated the contaminating bacteria in primary hip arthroplasty and their sensitivity to the prophylactic antibiotics currently in use. Impressions (627) of the gloved hands of the surgical team in 50 total hip arthroplasties were obtained on blood agar. The gloves were changed after draping, at intervals of 20 minutes thereafter, and before using cement. Changes were also undertaken whenever a visible puncture was detected. The culture plates were incubated at 37°C for 48 hours. Isolates were identified and tested for sensitivity to flucloxacillin, which is a recognised indicator of sensitivity to cefuroxime. They were also tested against other agents depending upon their appearance on Gram staining. We found contamination in 57 (9%) impressions and 106 bacterial isolates. Coagulase-negative staphylococci were seen most frequently (68.9%), but we also isolated
Polymethylmethacrylate remains one of the most enduring materials in orthopaedic surgery. It has a central role in the success of total joint replacement and is also used in newer techniques such as percutaneous vertebroplasty and kyphoplasty. This article describes the current uses and limitations of polymethylmethacrylate in orthopaedic surgery. It focuses on its mechanical and chemical properties and links these to its clinical performance. The behaviour of antibiotic-loaded bone cement are discussed, together with areas of research that are now shedding light upon the behaviour of this unique biomaterial.
Fractures of the proximal femur are one of the
greatest challenges facing the medical community, constituting a
heavy socioeconomic burden worldwide. Controversy exists regarding
the optimal treatment for patients with unstable trochanteric proximal
femoral fractures. The recognised treatment alternatives are extramedullary
fixation usually with a sliding hip screw and intramedullary fixation
with a cephalomedullary nail. Current evidence suggests that best
results and lowest complication rates occur using a sliding hip screw.
Complications in these difficult fractures are relatively common
regardless of type of treatment. We believe that a novel device,
the X-Bolt dynamic plating system, may offer superior fixation over
a sliding hip screw with lower reoperation risk and better function.
We therefore propose to investigate the clinical effectiveness of
the X-bolt dynamic plating system compared with standard sliding
hip screw fixation within the framework of a the larger WHiTE (Warwick
Hip Trauma Evaluation) Comprehensive Cohort Study. Cite this article:
All major studies have incorporated the use of prolonged courses of parenteral or oral antibiotic therapy in the management of two-stage revision of an infected total knee arthroplasty. We present a series of 59 consecutive patients, all with microbiologically-proven deep infection of a total knee arthroplasty, in whom a prolonged course of antibiotic therapy was not routinely used. The mean follow-up was 56.4 months (24 to 114). Of the 38 patients who underwent a staged exchange, infection was successfully eradicated in 34 (89%) but recurrent or persistent infection was present in four (11%). Our rate of cure for infection is similar to that reported elsewhere. We conclude that a prolonged course of antibiotic therapy seems not to alter the incidence of recurrent or persistent infection. The costs of the administration of antibiotics are high and such a regime may be unnecessary.
In our department we use an enhanced recovery
protocol for joint replacement of the lower limb. This incorporates the
use of intravenous tranexamic acid (IVTA; 15 mg/kg) at the induction
of anaesthesia. Recently there was a national shortage of IVTA for
18 weeks; during this period all patients received an oral preparation
of tranexamic acid (OTA; 25 mg/kg). This retrospective study compares
the safety (surgical and medical complications) and efficacy (reduction
of transfusion requirements) of OTA and IVTA. During the study period
a total of 2698 patients received IVTA and 302 received OTA. After
adjusting for a range of patient and surgical factors, the odds
ratio (OR) of receiving a blood transfusion was significantly higher
with IVTA than with OTA (OR 0.48 (95% confidence interval 0.26 to
0.89), p = 0.019), whereas the safety profile was similar, based
on length of stay, rate of readmission, return to theatre, deep
infection, stroke, gastrointestinal bleeding, myocardial infarction,
pneumonia, deep-vein thrombosis and pulmonary embolism. The financial
benefit of OTA is £2.04 for a 70 kg patient; this is amplified when
the cost saving associated with significantly fewer blood transfusions
is considered. Although the number of patients in the study is modest, this
work supports the use of OTA, and we recommend that a randomised
trial be undertaken to compare the different methods of administering
tranexamic acid. Cite this article:
The removal of all prosthetic material and a
two-stage revision procedure is the established standard management of
an infected total hip replacement (THR). However, the removal of
well-fixed femoral cement is time-consuming and can result in significant
loss of bone stock and femoral shaft perforation or fracture. We
report our results of two-stage revision THR for treating infection,
with retention of the original well-fixed femoral cement mantle
in 15 patients, who were treated between 1989 and 2002. Following
partial excision arthroplasty, patients received local and systemic
antibiotics and underwent reconstruction and re-implantation at
a second-stage procedure, when the infection had resolved. The mean follow-up of these 15 patients was 82 months (60 to
192). Two patients had positive microbiology at the second stage
and were treated with six weeks of appropriate antibiotics; one
of these developed recurrent infection requiring further revision.
Successful eradication of infection was achieved in the remaining
14 patients. We conclude that when two-stage revision is used for the treatment
of peri-prosthetic infection involving a THR, a well-fixed femoral
cement mantle can be safely left
The aim of this study was to evaluate whether
coating titanium discs with selenium in the form of sodium selenite decreased
bacterial adhesion of In order to evaluate bacterial adhesion, sterile titanium discs
were coated with increasing concentrations of selenium and incubated
with bacterial solutions of The tested Selenium coating is a promising method to reduce bacterial attachment
on prosthetic material. Cite this article:
The aim of our study was to describe the characteristics,
treatment, and outcomes of patients with periprosthetic joint infection
(PJI) and normal inflammatory markers after total knee arthroplasty
(TKA) and total hip arthroplasty (THA). In total 538 TKAs and 414 THAs underwent surgical treatment for
PJI and met the inclusion criteria. Pre-operative erythrocyte sedimentation
rate (ESR) and C-reactive protein level (CRP) were reviewed to identify
the seronegative cohort. An age- and gender-matched cohort was identified
from the remaining patients for comparison. Overall, 4% of confirmed
infections were seronegative (21 TKA and 17 THA). Of those who underwent
pre-operative aspiration, cultures were positive in 76% of TKAs
(n = 13) and 64% of THAs (n = 7). Cell count and differential were
suggestive of infection in 85% of TKA (n = 11) and all THA aspirates
(n = 5). The most common organism was coagulase-negative Cite this article:
We describe a patient who developed a delayed-type hypersensitivity reaction to piperacillin/tazobactam in the cement beads and a spacer inserted at revision of total replacement of the left knee. We believe that this is the first report of such a problem. Our experience suggests that a delayed-type hypersensitivity reaction should be considered when a mixture of antibiotics such as piperacillin/tazobactam has been used in the bone cement, beads or spacer and the patient develops delayed symptoms of pain or painful paraesthesiae, fever, rash and abnormal laboratory findings in the absence of infection. The diagnosis was made when identical symptoms were induced by a provocation challenge test.
Fractures of the proximal femur are one of the
greatest challenges facing the medical community, constituting a
heavy socioeconomic burden worldwide. The National Hip Fracture
Audit currently provides a framework for service evaluation. This
evaluation is based upon the assessment of process rather than assessment
of patient-centred outcome and therefore it fails to provide meaningful
data regarding the clinical effectiveness of treatments. This study
aims to capture data from the cohort of patients who present with
a fracture of the proximal femur at a single United Kingdom Major
Trauma Centre. Patient-centred outcomes will be recorded and provide
a baseline cohort within which to test the clinical effectiveness
of experimental interventions.
We report on two cases of infective spondylodiscitis
caused by We describe the clinical features, investigations and treatment
options.
We studied the effects of coating titanium implants with teicoplanin and clindamycin in 30 New Zealand White rabbits which were randomly assigned to three groups. The intramedullary canal of the left tibia of each rabbit was inoculated with 500 colony forming units of Staphylococcus aureus. Teicoplanin-coated implants were implanted into rabbits in group 1, clindamycin-coated implants into rabbits in group 2, and uncoated implants into those in group 3. All the rabbits were killed one week later. The implants were removed and cultured together with pieces of tibial bone and wound swabs. The rate of colonisation of the organisms in the three groups was compared. Organisms were cultured from no rabbits in group 1, one in group 2 but from all in group 3. There was no significant difference between groups 1 and 2 (p = 1.000). There were significant differences between groups 1 and 3 and groups 2 and 3 (p <
0.001). Significant protection against bacterial colonisation and infection was found with teicoplanin- and clindamycin-coated implants in this experimental model.
Giant cell tumour is the most common aggressive
benign tumour of the musculoskeletal system and has a high rate of
local recurrence. When it occurs in proximity to the hip, reconstruction
of the joint is a challenge. Options for reconstruction after wide
resection include the use of a megaprosthesis or an allograft-prosthesis
composite. We performed a clinical and radiological study to evaluate
the functional results of a proximal femoral allograft-prosthesis
composite in the treatment of proximal femoral giant cell tumour
after wide resection. This was an observational study, between 2006
and 2012, of 18 patients with a mean age of 32 years (28 to 42)
and a mean follow-up of 54 months (18 to 79). We achieved excellent
outcomes using Harris Hip Score in 13 patients and a good outcome
in five. All allografts united. There were no complications such
as infection, failure, fracture or resorption of the graft, or recurrent
tumour. Resection and reconstruction of giant cell tumours with
proximal femoral allograft–prosthesis composite is a better option
than using a prosthesis considering preservation of bone stock and excellent
restoration of function. A good result requires demanding bone banking techniques, effective
measures to prevent infection and stability at the allograft-host
junction. Cite this article:
We report the five year outcomes of a two-stage
approach for infected total hip replacement. This is a single-surgeon
experience at a tertiary centre where the more straightforward cases
are treated using single-stage exchange. This study highlights the
vital role of the multidisciplinary team in managing these cases. A total of 125 patients (51 male, 74 female) with a mean age
of 68 years (42 to 78) were reviewed prospectively. Functional status
was assessed using the Harris hip score (HHS). The mean HHS improved
from 38 (6 to 78.5) pre-operatively to 81.2 (33 to 98) post-operatively.
Staphylococcus species were isolated in 85 patients (68%). The rate of control of infection was 96% at five years. In all,
19 patients died during the period of the study. This represented
a one year mortality of 0.8% and an overall mortality of 15.2% at
five years. No patients were lost to follow-up. We report excellent control of infection in a series of complex
patients and infections using a two-stage revision protocol supported
by a multidisciplinary approach. The reason for the high rate of
mortality in these patients is not known. Cite this article:
This paper reviews the current literature concerning the main clinical factors which can impair the healing of fractures and makes recommendations on avoiding or minimising these in order to optimise the outcome for patients. The clinical implications are described.
The outcome of an anatomical shoulder replacement
depends on an intact rotator cuff. In 1981 Grammont designed a novel
large-head reverse shoulder replacement for patients with cuff deficiency.
Such has been the success of this replacement that it has led to
a rapid expansion of the indications. We performed a systematic
review of the literature to evaluate the functional outcome of each
indication for the reverse shoulder replacement. Secondary outcome
measures of range of movement, pain scores and complication rates
are also presented.
Intramedullary infection in long bones represents
a complex clinical challenge, with an increasing incidence due to the
increasing use of intramedullary fixation. We report a prospective
case series using an intramedullary reaming device, the Reamer–Irrigator–Aspirator
(RIA) system, in association with antibiotic cement rods for the
treatment of lower limb long bone infections. A total of 24 such
patients, 16 men and eight women, with a mean age of 44.5 years
(17 to 75), 14 with femoral and 10 with tibial infection, were treated
in a staged manner over a period of 2.5 years in a single referral
centre. Of these, 21 patients had had previous surgery, usually
for fixation of a fracture (seven had sustained an open fracture
originally and one had undergone fasciotomies). According to the
Cierny–Mader classification system, 18 patients were classified
as type 1A, four as 3A (discharging sinus tract), one as type 4A
and one as type 1B. Cite this article:
We investigated the capacity of patient warming
devices to disrupt the ultra-clean airflow system. We compared the effects
of two patient warming technologies, forced-air and conductive fabric,
on operating theatre ventilation during simulated hip replacement
and lumbar spinal procedures using a mannequin as a patient. Infection
data were reviewed to determine whether joint infection rates were
associated with the type of patient warming device that was used. Neutral-buoyancy detergent bubbles were released adjacent to
the mannequin’s head and at floor level to assess the movement of
non-sterile air into the clean airflow over the surgical site. During
simulated hip replacement, bubble counts over the surgical site
were greater for forced-air than for conductive fabric warming when
the anaesthesia/surgery drape was laid down (p = 0.010) and at half-height
(p <
0.001). For lumbar surgery, forced-air warming generated
convection currents that mobilised floor air into the surgical site
area. Conductive fabric warming had no such effect. A significant increase in deep joint infection, as demonstrated
by an elevated infection odds ratio (3.8, p = 0.024), was identified
during a period when forced-air warming was used compared to a period
when conductive fabric warming was used. Air-free warming is, therefore,
recommended over forced-air warming for orthopaedic procedures.
The April 2014 Knee Roundup360 looks at: mobile compression as good as chemical thromboprophylaxis; patellar injury with MIS knee surgery; tibial plateau fracture results not as good as we thought; back and knee pain; metaphyseal sleeves may be the answer in revision knee replacement; oral tranexamic acid; gentamycin alone in antibiotic spacers; and whether the jury is still out on unloader braces.
In this retrospective study, we investigated
the results of revision total hip replacement (THR) using a cemented long-stemmed
Exeter femoral component, with a minimum length of 205 mm in patients
with extensive femoral bone defects. The study included 37 consecutive
patients with a mean age of 76 years (39 to 93) and a mean follow-up
of nine years (5 to 16). A total of 26 patients (70%) had a pre-operative
Endo-Klinik score of 3 or 4. Impaction bone grafting was used in
24 patients (65%). At the time of evaluation, 22 patients (59%)
were still alive and were evaluated clinically and radiologically.
A total of 14 patients died during follow-up and their data were
included until the time of their death. One reconstruction failed
after five years and five months owing to recurrent dislocation:
the hip was converted to an excision arthroplasty. Intra-operative
fractures or fissures were encountered in nine patients (24%), but
none occurred during impaction of the bone graft. Post-operative
peri-prosthetic fractures occurred in two patients (5%); both were
treated with plate fixation. At nine years, survival with the endpoint
of all-cause re-revision was 96.3% (95% CI 76.4 to 99.5); including
re-operations for any reason, it was 80.7% (95% CI 56.3 to 92.3%).
There were no re-revisions for aseptic loosening. The survival of long stem cemented femoral components following
revision THR is satisfactory in a fragile population with extensive
femoral defects. Cite this article: