Advertisement for orthosearch.org.uk
Results 161 - 180 of 1168
Results per page:
Bone & Joint 360
Vol. 8, Issue 5 | Pages 27 - 30
1 Oct 2019


The Journal of Bone & Joint Surgery British Volume
Vol. 60-B, Issue 1 | Pages 56 - 57
1 Feb 1978
Dreyfuss U Kessler I

Two cases of unusual snapping at the elbow are described. In both, the medial head of the triceps was found to be separated from the main muscle belly. During flexion of the elbow, the medial head dislocated over the medial epicondyle, producing a characteristic snapping phenomenon. Both cases were of long standing and had been asymptomatic for years. The first clinical symptoms were those of an ulnar neuropathy. In order to restore the normal position of the medial head of the triceps, its tendon was detached from the olecranon, passed under the central tendon and interlaced to it. The ulnar nerve was left in the epicondylar groove in one case and transposed anteriorly in the other. At the end of the procedure flexion of the elbow was unobstructed and the snapping phenomenon had disappeared


Bone & Joint 360
Vol. 9, Issue 2 | Pages 3 - 6
1 Apr 2020
Myint Y Ollivere B


The Journal of Bone & Joint Surgery British Volume
Vol. 66-B, Issue 5 | Pages 737 - 741
1 Nov 1984
Rydholm U Tjornstrand B Pettersson H Lidgren L

Fifteen patients with rheumatoid arthritis had 19 elbow arthroplasties with the Wadsworth type of surface replacement prosthesis. After a follow-up period averaging 30 months, 11 patients with 15 elbow arthroplasties were entirely satisfied with their freedom from pain and range of movement. Radiologically, however, the humeral component was loose in 10 of the 19 elbows and the ulnar component in 5. Two patients had reoperation, one to remove a prosthesis for early deep infection and one to exchange a humeral component which was loose. The risk of mechanical loosening is reduced by accurate positioning of the humeral component, but there is a high potential for failure. Changes in the design of the prosthesis and better instrumentation for alignment of the components are desirable. Prosthetic replacement of the elbow should still be regarded as experimental


The Journal of Bone & Joint Surgery British Volume
Vol. 67-B, Issue 3 | Pages 378 - 381
1 May 1985
Grimer R Brooks S

Four cases of arterial damage resulting from closed posterior dislocation of the elbow are described. Two of these have been successfully treated by conservative methods and two by vein graft to the damaged artery. Sixteen previous cases are detailed and the management of this uncommon complication of dislocated elbow is discussed


Bone & Joint 360
Vol. 7, Issue 2 | Pages 23 - 25
1 Apr 2018


Bone & Joint 360
Vol. 7, Issue 4 | Pages 22 - 25
1 Aug 2018


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 8 | Pages 1138 - 1140
1 Nov 2003
Chapman-Sheath PJ Giangrande P Carr AJ

Total elbow replacement can be a valuable option for the treatment of the elbow in haemophilia where there are associated arthropathic changes. We describe the outcome of seven elbow replacements in five consecutive patients with severe haemophilia A (native factor levels < 1%) at a mean of 42 months (25 to 65) after operation. All the patients had excellent relief of pain and improvement in function. One failure was due to infection in an immunocompromised patient with both HIV and Hepatitis C antibodies who was on anti-retroviral chemotherapy. The implant was revised at 30 months in a one-stage procedure and showed no evidence of loosening or infection 35 months later


Bone & Joint 360
Vol. 7, Issue 1 | Pages 22 - 24
1 Feb 2018


The Journal of Bone & Joint Surgery British Volume
Vol. 55-B, Issue 1 | Pages 106 - 111
1 Feb 1973
Wilson DW Arden GP Ansell BM

1. Synovectomy of the elbow affected by rheumatoid arthritis is a worthwhile procedure even in the presence of advanced radiological changes. 2. Relief of pain is good (93 per cent) and movement is retained (87 per cent). 3. Although the follow-up in this series was short, averaging nineteen months, the results seem to be maintained. 4. Good access to the joint may be had through medial and lateral incisions, and division of the olecranon is unnecessary. A lateral incision alone is not recommended. 5. The ulnar nerve should be preserved during dissection. Anterior transposition is needed only if there are neurological symptoms before operation


Bone & Joint 360
Vol. 6, Issue 6 | Pages 25 - 28
1 Dec 2017


Bone & Joint 360
Vol. 7, Issue 3 | Pages 21 - 24
1 Jun 2018


The Journal of Bone & Joint Surgery British Volume
Vol. 44-B, Issue 1 | Pages 119 - 121
1 Feb 1962
Kilburn P Sweeney JG Silk FF

1. Rupture of the brachial artery or of one of its divisions in association with elbow injuries is probably more common than a survey of the literature would imply. Three cases of rupture of the brachial artery complicating compound dislocation of the elbow are reported. 2. These cases appear to have a consistent pattern of soft-tissue damage, with avulsion of the common flexor origin, and a varying degree of damage to the biceps and brachialis. The median nerve escaped injury. 3. The method of dealing with the divided vessels does not appear to be of importance in determining the outcome, simple ligation being as satisfactory as attempts at grafting or suture. 4. In no case was there any evidence of Volkmann's contracture. Provided rapid reduction of the dislocation is effected, together with ligation of the vessels, a satisfactory return of the circulation may be expected


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 5 | Pages 738 - 739
1 Jul 2001
Oka Y Ikeda M

We treated a patient with extensive osteochondritis dissecans of the elbow by an osteochondral graft from a rib. It had consolidated seven months after operation. When seen at follow-up, after seven years and eight months, the elbow was free from pain with an improvement in the range of movement of 24°


The Journal of Bone & Joint Surgery British Volume
Vol. 50-B, Issue 3 | Pages 644 - 652
1 Aug 1968
Vizkelety T Aszodi K

1. A case of symmetrical bilateral calcareous bursitis at the elbow is described. 2. Metabolic and neurotrophic factors played a role in its genesis. 3. Chemical analysis showed a similarity between the ratio of calcium phosphate and calcium carbonate in dystrophic calcification and in the fluid in the bursal cavity. 4. An inflammatory reaction was seen around the calcium appearing interstitially: this was probably not a consequence of chemical stimuli


Bone & Joint 360
Vol. 6, Issue 3 | Pages 21 - 24
1 Jun 2017


Bone & Joint 360
Vol. 6, Issue 5 | Pages 21 - 24
1 Oct 2017


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 5 | Pages 702 - 704
1 Jul 2000
Cole AS Hill GA Abela M Carr AJ

We present three cases of recurrent instability of the elbow in association with the Ehlers-Danlos syndrome. The pattern of instability has not previously been reported. We describe our procedure for achieving stability using a bone graft to the olecranon fossa which gave a functional range of movement


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 3 | Pages 490 - 492
1 May 1998
Moritomo H Tada K Yoshida T Kawatsu N

Persistent dislocation of the elbow after a fracture of the coronoid process is a difficult problem. We have performed an open reduction with reconstruction of the coronoid by an osteocartilaginous graft from the ipsilateral olecranon for two patients. Both achieved a painless, stable joint with a functional range of movement. The joint surface of the graft has a similar curve to that of the coronoid giving good congruency and stability. The technique is simple and the graft is obtained through the same incision


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 7 | Pages 1006 - 1010
1 Sep 2003
Jensen SL Deutch SR Olsen BS Søjbjerg JO Sneppen O

We studied the stabilising effect of prosthetic replacement of the radial head and repair of the medial collateral ligament (MCL) after excision of the radial head and section of the MCL in five cadaver elbows. Division of the MCL increased valgus angulation (mean 3.9 ± 1.5°) and internal rotatory laxity (mean 5.3 ± 2.0°). Subsequent excision of the radial head allowed additional valgus (mean 11.1 ± 7.3°) and internal rotatory laxity (mean 5.7 ± 3.9°). Isolated replacement of the radial head reduced valgus laxity to the level before excision of the head, while internal rotatory laxity was still greater (2.8 ± 2.1°). Isolated repair of the MCL corrected internal rotatory laxity, but a slight increase in valgus laxity remained (mean 0.7 ± 0.6°). Combined replacement of the head and repair of the MCL restored stability completely. We conclude that the radial head is a constraint secondary to the MCL for both valgus displacement and internal rotation. Isolated repair of the ligament is superior to isolated prosthetic replacement and may be sufficient to restore valgus and internal rotatory stability after excision of the radial head in MCL-deficient elbows