The October 2015 Wrist &
Hand Roundup360 looks at: Base of thumb arthritis – steroids not a waste of time; De Quervain’s tenosynovitis and steroids; Use your therapy time wisely!; Excision osteotomy for the carpometacarpal joint?; CORDLESS at five years?; Arthroscopy again of no benefit?; Distal radius stirring up trouble again!; Scaphoid arthroscopy under the spotlight
The spiral blade modification of the Dynamic
Hip Screw (DHS) was designed for superior biomechanical fixation
in the osteoporotic femoral head. Our objective was to compare clinical
outcomes and in particular the incidence of loss of fixation. In a series of 197 consecutive patients over the age of 50 years
treated with DHS-blades (blades) and 242 patients treated with conventional
DHS (screw) for AO/OTA 31.A1 or A2 intertrochanteric fractures were
identified from a prospectively compiled database in a level 1 trauma
centre. Using propensity score matching, two groups comprising 177
matched patients were compiled and radiological and clinical outcomes
compared. In each group there were 66 males and 111 females. Mean
age was 83.6 (54 to 100) for the conventional DHS group and 83.8
(52 to 101) for the blade group. Loss of fixation occurred in two blades and 13 DHSs. None of
the blades had observable migration while nine DHSs had gross migration
within the femoral head before the fracture healed. There were two
versus four implant cut-outs respectively and one side plate pull-out
in the DHS group. There was no significant difference in mortality
and eventual walking ability between the groups. Multiple logistic
regression suggested that poor reduction (odds ratio (OR) 11.49,
95% confidence intervals (CI) 1.45 to 90.9, p = 0.021) and fixation
by DHS (OR 15.85, 95%CI 2.50 to 100.3, p = 0.003) were independent
predictors of loss of fixation. The spiral blade design may decrease the risk of implant migration
in the femoral head but does not reduce the incidence of cut-out
and reoperation. Reduction of the fracture is of paramount importance
since poor reduction was an independent predictor for loss of fixation
regardless of the implant being used. Cite this article:
The August 2015 Trauma Roundup360 looks at: Thromboprophylaxis not required in lower limb fractures; Subclinical thyroid dysfunction and fracture risk: moving the boundaries in fracture; Posterior wall fractures refined; Neurological injury and acetabular fracture surgery; Posterior tibial plateau fixation; Tibial plateau fractures in the longer term; Comprehensive orthogeriatric care and hip fracture; Compartment syndrome: in the eye of the beholder?
The June 2015 Spine Roundup360 looks at: Less is more in pyogenic vertebral osteomyelitis; Paracetamol out of favour in spinal pain but effective for osteoarthritis; Local wound irrigation to reduce infection?; Lumbar facet joint effusion: a reliable prognostic sign?; SPORT for the octogenarian; Neurological deterioration following traumatic spinal cord injury; PROMS in spinal surgery
Techniques for fixation of fractures of the lateral
malleolus have remained essentially unchanged since the 1960s, but
are associated with complication rates of up to 30%. The fibular
nail is an alternative method of fixation requiring a minimal incision
and tissue dissection, and has the potential to reduce the incidence
of complications. We reviewed the results of 105 patients with unstable fractures
of the ankle that were fixed between 2002 and 2010 using the Acumed
fibular nail. The mean age of the patients was 64.8 years (22 to
95), and 80 (76%) had significant systemic medical comorbidities.
Various different configurations of locking screw were assessed
over the study period as experience was gained with the device.
Nailing without the use of locking screws gave satisfactory stability
in only 66% of cases (4 of 6). Initial locking screw constructs
rendered between 91% (10 of 11) and 96% (23 of 24) of ankles stable.
Overall, seven patients had loss of fixation of the fracture and
there were five post-operative wound infections related to the distal
fibula. This lead to the development of the current technique with
a screw across the syndesmosis in addition to a distal locking screw.
In 21 patients treated with this technique there have been no significant
complications and only one superficial wound infection. Good fracture
reduction was achieved in all of these patients. The mean physical
component Short-Form 12, Olerud and Molander score, and American Academy
of Orthopaedic Surgeons Foot and Ankle outcome scores at a mean
of six years post-injury were 46 (28 to 61), 65 (35 to 100) and
83 (52 to 99), respectively. There have been no cases of fibular
nonunion. Nailing of the fibula using our current technique gives good
radiological and functional outcomes with minimal complications,
and should be considered in the management of patients with an unstable
ankle fracture.
Loosening of pedicle screws is a major complication of posterior
spinal stabilisation, especially in the osteoporotic spine. Our
aim was to evaluate the effect of cement augmentation compared with
extended dorsal instrumentation on the stability of posterior spinal
fixation. A total of 12 osteoporotic human cadaveric spines (T11-L3) were
randomised by bone mineral density into two groups and instrumented
with pedicle screws: group I (SHORT) separated T12 or L2 and group
II (EXTENDED) specimen consisting of T11/12 to L2/3. Screws were
augmented with cement unilaterally in each vertebra. Fatigue testing
was performed using a cranial-caudal sinusoidal, cyclic (1.0 Hz)
load with stepwise increasing peak force.Aims
Materials and Methods
The June 2014 Children’s orthopaedics Roundup360 looks at: plaster wedging in paediatric forearm fractures; the medial approach for DDH; Ponseti – but not as he knew it?; Salter osteotomy more accurate than Pemberton in DDH; is the open paediatric fracture an emergency?; bang up-to-date with femoral external fixation; indomethacin, heterotopic ossification and cerebral palsy hips; lengthening nails for congenital femoral deformities, and is MRI the answer to imaging of the physis?
The April 2015 Spine Roundup360 looks at: Hyperostotic spine in injury; App based back pain control; Interspinous process devices should be avoided in claudication; Robot assisted pedicle screws: fad or advance?; Vancomycin antibiotic power in spinal surgery; What to do with that burst fracture?; Increasing complexity of spinal fractures in major trauma pathways; Vitamin D and spinal fractures
The Gamma nail is frequently used in unstable
peri-trochanteric hip fractures. We hypothesised that mechanical failure
of the Gamma nail was associated with inadequate proximal three-point
fixation. We identified a consecutive series of 299 Gamma nails
implanted in 299 patients over a five-year period, 223 of whom fulfilled
our inclusion criteria for investigation. The series included 61
men and 162 women with a mean age of 81 years (20 to 101). Their fractures
were classified according to the Modified Evans’ classification
and the quality of fracture reduction was graded. The technical
adequacy of three points of proximal fixation was recorded from
intra-operative fluoroscopic images, and technical inadequacy for
each point was defined. All patients were followed to final follow-up
and mechanical failures were identified. A multivariate statistical
analysis was performed, adjusting for confounders. A total of 16
failures (7.2%) were identified. The position of the lag screw relative
to the lateral cortex was the most important point of proximal fixation,
and when inadequate the failure rate was 25.8% (eight of 31: odds
ratio 7.5 (95% confidence interval 2.5 to 22.7), p <
0.001). Mechanical failure of the Gamma nail in peri-trochanteric femoral
fractures is rare (<
1%) when three-point proximal fixation is
achieved. However, when proximal fixation is inadequate, failure
rates increase. The strongest predictor of failure is positioning
the lateral end of the lag screw short of the lateral cortex. Adherence
to simple technical points minimises the risk of fixation failure
in this vulnerable patient group. Cite this article:
The aim of this study was to quantify the stability
of fracture-implant complex in fractures after fixation. A total
of 15 patients with an undisplaced fracture of the femoral neck,
treated with either a dynamic hip screw or three cannulated hip
screws, and 16 patients with an AO31-A2 trochanteric fracture treated
with a dynamic hip screw or a Gamma Nail, were included. Radiostereometric
analysis was used at six weeks, four months and 12 months post-operatively
to evaluate shortening and rotation. Migration could be assessed in ten patients with a fracture of
the femoral neck and seven with a trochanteric fracture. By four
months post-operatively, a mean shortening of 5.4 mm (-0.04 to 16.1)
had occurred in the fracture of the femoral neck group and 5.0 mm
(-0.13 to 12.9) in the trochanteric fracture group. A wide range
of rotation occurred in both types of fracture. Right-sided trochanteric
fractures seem more rotationally stable than left-sided fractures. This prospective study shows that migration at the fracture site
occurs continuously during the first four post-operative months,
after which stabilisation occurs. This information may allow the
early recognition of patients at risk of failure of fixation. Cite this article:
The results of the DRAFFT (distal radius acute
fracture fixation trial) study, which compared volar plating with
Kirschner (K-) wire fixation for dorsally displaced fractures of
the distal radius, were published in August 2014. The use of K-wires
to treat these fractures is now increasing, with a concomitant decline
in the use of volar locking plates. We provide a critical appraisal of the DRAFFT study and question
whether surgeons have been unduly influenced by its headline conclusions. Cite this article:
We performed a retrospective study to determine
the effect of osteoporosis on the functional outcome of osteoporotic
distal radial fractures treated with a volar locking plate. Between
2009 and 2012 a total of 90 postmenopausal women with an unstable
fracture of the distal radius treated with a volar locking plate
were studied. Changes in the radiological parameters of 51 patients
with osteoporosis (group 1, mean age 66.9, mean T-score –3.16 ( We found that osteoporosis does not have a negative effect on
the functional outcome and additional analysis did not show a correlation
between T-score and outcome. Cite this article:
A retrospective study was performed in 100 children
aged between two and 16 years, with a dorsally angulated stable
fracture of the distal radius or forearm, who were treated with
manipulation in the emergency department (ED) using intranasal diamorphine
and 50% oxygen and nitrous oxide. Pre- and post-manipulation radiographs,
the final radiographs and the clinical notes were reviewed. A successful
reduction was achieved in 90 fractures (90%) and only three children
(3%) required remanipulation and Kirschner wire fixation or internal
fixation. The use of Entonox and intranasal diamorphine is safe and effective
for the closed reduction of a stable paediatric fracture of the
distal radius and forearm in the ED. By facilitating discharge on the same day, there is a substantial
cost benefit to families and the NHS and we recommend this method. Take home message: Simple easily reducible fractures of the distal
radius and forearm in children can be successfully and safely treated
in the ED using this approach, thus avoiding theatre admission and
costly hospital stay. Cite this article:
Failure of fixation is a common problem in the treatment of osteoporotic fractures around the hip. The reinforcement of bone stock or of fixation of the implant may be a solution. Our study assesses the existing evidence for the use of bone substitutes in the management of these fractures in osteoporotic patients. Relevant publications were retrieved through Medline research and further scrutinised. Of 411 studies identified, 22 met the inclusion criteria, comprising 12 experimental and ten clinical reports. The clinical studies were evaluated with regard to their level of evidence. Only four were prospective and randomised. Polymethylmethacrylate and calcium-phosphate cements increased the primary stability of the implant-bone construct in all experimental and clinical studies, although there was considerable variation in the design of the studies. In randomised, controlled studies, augmentation of intracapsular fractures of the neck of the femur with calcium-phosphate cement was associated with poor long-term results. There was a lack of data on the long-term outcome for trochanteric fractures. Because there were only a few, randomised, controlled studies, there is currently poor evidence for the use of bone cement in the treatment of fractures of the hip.
We hypothesised that the use of pulsed electromagnetic
field (PEMF) bone growth stimulation in acute scaphoid fractures
would significantly shorten the time to union and reduce the number
of nonunions in a randomised, double-blind, placebo-controlled multicentre
trial. A total of 102 patients (78 male, 24 female; mean age 35
years (18 to 77)) from five different medical centres with a unilateral
undisplaced acute scaphoid fracture were randomly allocated to PEMF
(n = 51) or placebo (n = 51) and assessed with regard to functional
and radiological outcomes (multiplanar reconstructed CT scans) at
6, 9, 12, 24 and 52 weeks. The overall time to clinical and radiological healing
did not differ significantly between the active PEMF group and the
placebo group. We concluded that the addition of PEMF bone growth
stimulation to the conservative treatment of acute scaphoid fractures
does not accelerate bone healing. Cite this article: