Jepegnanam TS

Four men who presented with chronic dislocation of the radial head and nonunion or malunion of the ulna were reviewed after open reduction of the radial head and internal fixation of the ulna in attempted overcorrection. Their mean age was 37 years (28 to 46) and the mean interval between injury and reconstruction was nine months (4 to 18).

The mean follow-up was 24 months (15 to 36). One patient who had undergone secondary excision of the radial head was also followed up for comparison.

The three patients who had followed the treatment protocol had nearly normal flexion, extension and supination and only very occasional pain. All had considerable loss of pronation which did not affect patient satisfaction.

Preservation of the radial head in chronic adult Monteggia fractures appears to be a promising mode of treatment.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 12 | Pages 1620 - 1626
1 Dec 2007
Toma CD Machacek P Bitzan P Assadian O Trieb K Wanivenhaus A

We retrospectively compared wrist arthrodesis using the Mannerfelt technique in 19 or an AO-plate in 23 patients with long-standing rheumatoid arthritis. The mean follow-up was for 76 months.

Compared with the Mannerfelt fusion group, patients in the AO-plate group reported greater satisfaction with their wrist function (74% vs 37%, p = 0.015). Complications were reported in six wrists in the AO-plate group and two wrists in the Mannerfelt fusion group (p = 0.258). At final follow-up, 95% of patients (41) reported either no pain or only mild pain. There was improvement in flexion of the finger joints in both groups but no significant improvement in the extension lag in either group.

Both methods relieve pain and improve function. Overall, the activities of daily living scores and the patients’ subjective assessment of outcome tended to be higher in the AO-plate group than in the Mannerfelt fusion group, although the difference was not statistically significant. Similarly, although more postoperative complications occurred in the AO-plate group, the difference between the two groups was not statistically significant.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 3 | Pages 362 - 365
1 Mar 2006
Mangwani J Nadarajah R Paterson JMH

Although supracondylar fracture is a very common elbow injury in childhood, there is no consensus on the timing of surgery, approach for open reduction and positioning of fixation wires. We report our ten-year experience between 1993 and 2003 in 291 children.

Most fractures (285; 98%) were extension injuries, mainly Gartland types II (73; 25%) and III (163; 56%). Six (2%) were open fractures and a neurovascular deficit was seen in 12 (4%) patients. Of the 236 children (81%) who required an operation, 181 (77%) were taken to theatre on the day of admission. Most (177; 75%) of the operations were performed by specialist registrars. Fixation was by crossed Kirschner wires in 158 of 186 (85%) patients and open reduction was necessary in 52 (22%).

A post-operative neurological deficit was seen in nine patients (4%) and three (1%) required exploration of the ulnar nerve. Only 22 (4%) patients had a long-term deformity, nine (3%) from malreduction and three (1%) because of growth arrest, but corrective surgery for functional limitation was required in only three (1%) patients.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 2 | Pages 196 - 201
1 Feb 2007
Veitch S Blake SM David H

We prospectively reviewed 14 patients with deficiency of the proximal pole of the scaphoid who were treated by rib osteochondral replacement arthroplasty.

Improvement in wrist function occurred in all except one patient with enhanced grip strength, less pain and maintenance of wrist movement. In 13 patients wrist function was rated as good or excellent according to the modified wrist function score of Green and O’Brien. The mean pre-operative score of 54 (35 to 80) rose to 79 (50 to 90) at review at a mean of 64 months (27 to 103). Carpal alignment did not deteriorate in any patient and there were no cases of nonunion or significant complications.

This procedure can restore the mechanical integrity of the proximal pole of the scaphoid satisfactorily and maintain wrist movement while avoiding the potential complications of alternative replacement arthroplasty techniques and problems associated with vascularised grafts and salvage techniques.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 3 | Pages 301 - 305
1 Mar 2007
Ziaee H Daniel J Datta AK Blunt S McMinn DJW

Metal-on-metal bearings are being increasingly used in young patients. The potential adverse effects of systemic metal ion elevation are the subject of ongoing investigation. The purpose of this study was to investigate whether cobalt and chromium ions cross the placenta of pregnant women with a metal-on-metal hip resurfacing and reach the developing fetus. Whole blood levels were estimated using high-resolution inductively-coupled plasma mass spectrometry.

Our findings showed that cobalt and chromium are able to cross the placenta in the study patients with metal-on-metal hip resurfacings and in control subjects without any metal implants. In the study group the mean concentrations of cobalt and chromium in the maternal blood were 1.39 μg/l (0.55 to 2.55) and 1.28 μg/l (0.52 to 2.39), respectively. The mean umbilical cord blood concentrations of cobalt and chromium were comparatively lower, at 0.839 μg/l (0.42 to 1.75) and 0.378 μg/l (0.14 to 1.03), respectively, and this difference was significant with respect to chromium (p < 0.05).

In the control group, the mean concentrations of cobalt and chromium in the maternal blood were 0.341 μg/l (0.18 to 0.54) and 0.199 μg/l (0.12 to 0.33), and in the umbilical cord blood they were 0.336 μg/l (0.17 to 0.5) and 0.194 μg/l (0.11 to 0.56), respectively. The differences between the maternal and umbilical cord blood levels in the controls were marginal, and not statistically significant (p > 0.05). The mean cord blood level of cobalt in the study patients was significantly greater than that in the control group (p < 0.01). Although the mean umbilical cord blood chromium level was nearly twice as high in the study patients (0.378 μg/l) as in the controls (0.1934 μg/l), this difference was not statistically significant. (p > 0.05)

The transplacental transfer rate was in excess of 95% in the controls for both metals, but only 29% for chromium and 60% for cobalt in study patients, suggesting that the placenta exerts a modulatory effect on the rate of metal ion transfer.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 10 | Pages 1388 - 1395
1 Oct 2007
Hembree WC Ward BD Furman BD Zura RD Nichols LA Guilak F Olson SA

Post-traumatic arthritis is a frequent consequence of articular fracture. The mechanisms leading to its development after such injuries have not been clearly delineated. A potential contributing factor is decreased viability of the articular chondrocytes. The object of this study was to characterise the regional variation in the viability of chondrocytes following joint trauma. A total of 29 osteochondral fragments from traumatic injuries to joints that could not be used in articular reconstruction were analysed for cell viability using the fluorescence live/dead assay and for apoptosis employing the TUNEL assay, and compared with cadaver control fragments.

Chondrocyte death and apoptosis were significantly greater along the edge of the fracture and in the superficial zone of the osteochondral fragments. The middle and deep zones demonstrated significantly higher viability of the chondrocytes. These findings indicate the presence of both necrotic and apoptotic chondrocytes after joint injury and may provide further insight into the role of chondrocyte death in post-traumatic arthritis.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 1 | Pages 26 - 31
1 Jan 2007
Kawanabe K Akiyama H Onishi E Nakamura T

We retrospectively evaluated 42 hips which had undergone acetabular reconstruction using the Kerboull acetabular reinforcement device between September 1994 and December 1998. We used autogenous bone chips from the ilium and ceramic particle morsellised grafts, even in large acetabular bone defects, in the early stages of the study. Thereafter, femoral head allograft was used as bulk graft in patients with large acetabular defects. Ceramic blocks and the patients’ contralateral femoral head were also used as bulk graft. The mean follow-up period was 8.7 years (4.3 to 12).

Survivorship analysis was performed using radiological failure of the acetabular component, irrespective of whether it was revised, or not, as the end-point.

The survival rate of the morsellised graft group (25 hips) and the bulk graft group (17 hips) at ten years was 53% (95% confidence interval (CI) 42.5% to 63.5%) and 82% (95% CI 72.4% to 91.6%), respectively. The mid-term results of revision total hip replacement with the Kerboull device were better when bulk graft was used in any size of bone defect.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 2 | Pages 180 - 185
1 Feb 2007
Koëter S Diks MJF Anderson PG Wymenga AB

An abnormal lateral position of the tibial tuberosity causes distal malalignment of the extensor mechanism of the knee and can lead to lateral tracking of the patella causing anterior knee pain or objective patellar instability, characterised by recurrent dislocation. Computer tomography is used for a precise pre-operative assessment of the tibial tubercle-trochlear groove distance. A distance of more than 15 mm is considered to be pathological and an indication for surgery in symptomatic patients.

In a prospective study we performed a subtle transfer of the tibial tuberosity according to the information gained from the pre-operative CT scan. This method was applied to two groups of patients, those with painful lateral tracking of the patella, and those with objective patellar instability. We evaluated the clinical results in 30 patients in each group. The outcome was documented at 3, 12 and 24 months using the Lysholm scale, the Kujala score, and a visual analogue pain score.

Post-operatively, all but one patient in the instability group who had a patellar dislocation requiring further surgery reported good improvement with no further subluxation or dislocation. All patients in both groups had a marked improvement in pain and functional score. Two patients sustained a tibial fracture six and seven weeks after surgery. One patient suffered a per-operative fracture of the tibial tubercle which later required further fixation.

If carefully performed, this type of transfer of the tibial tubercle appears to be a satisfactory technique for the treatment of patients with an increased tibial tubercle-trochlear groove distance and who present with symptoms related to lateral maltracking of the patella.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 1 | Pages 114 - 121
1 Jan 2008
Pendegrass CJ Gordon D Middleton CA Sun SNM Blunn GW

Conventional amputation prostheses rely on the attachment of the socket to the stump, which may lead to soft-tissue complications. Intraosseous transcutaneous amputation prostheses (ITAPs) allow direct loading of the skeleton, but their success is limited by infection resulting from breaching of the skin at the interface with the implant. Keratinocytes provide the skin’s primary barrier function, while hemidesmosomes mediate their attachment to natural ITAP analogues. Keratinocytes must attach directly to the surface of the implant. We have assessed the proliferation, morphology and attachment of keratinocytes to four titaniumalloy surfaces in order to determine the optimal topography in vitro. We used immunolocalisation of adhesion complex components, scanning electron microscopy and transmission electron microscopy to assess cell parameters.

We have shown that the proliferation, morphology and attachment of keratinocytes are affected by the surface topography of the biomaterials used to support their growth. Smoother surfaces improved adhesion. We postulate that a smooth topography at the point of epithelium-ITAP contact could increase attachment in vivo, producing an effective barrier of infection.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 1 | Pages 121 - 126
1 Jan 2007
Jensen TB Overgaard S Lind M Rahbek O Bünger C Søballe K

Impacted bone allograft is often used in revision joint replacement. Hydroxyapatite granules have been suggested as a substitute or to enhance morcellised bone allograft. We hypothesised that adding osteogenic protein-1 to a composite of bone allograft and non-resorbable hydroxyapatite granules (ProOsteon) would improve the incorporation of bone and implant fixation. We also compared the response to using ProOsteon alone against bone allograft used in isolation. We implanted two non-weight-bearing hydroxyapatite-coated implants into each proximal humerus of six dogs, with each implant surrounded by a concentric 3 mm gap. These gaps were randomly allocated to four different procedures in each dog: 1) bone allograft used on its own; 2) ProOsteon used on its own; 3) allograft and ProOsteon used together; or 4) allograft and ProOsteon with the addition of osteogenic protein-1.

After three weeks osteogenic protein-1 increased bone formation and the energy absorption of implants grafted with allograft and ProOsteon. A composite of allograft, ProOsteon and osteogenic protein-1 was comparable, but not superior to, allograft used on its own.

ProOsteon alone cannot be recommended as a substitute for allograft around non-cemented implants, but should be used to extend the volume of the graft, preferably with the addition of a growth factor.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 3 | Pages 406 - 410
1 Mar 2006
Quinlan JF Watson RWG Kelly G Kelly PM O’Byrne JM Fitzpatrick JM

Injuries to the spinal cord may be associated with increased healing of fractures. This can be of benefit, but excessive bone growth can also cause considerable adverse effects.

We evaluated two groups of patients with fractures of the spinal column, those with neurological compromise (n = 10) and those without (n = 15), and also a control group with an isolated fracture of a long bone (n = 12). The level of transforming growth factor-beta (TGF-β), was measured at five time points after injury (days 1, 5, 10, 42 and 84).

The peak level of 142.79 ng/ml was found at day 84 in the neurology group (p < 0.001 vs other time points). The other groups peaked at day 42 and had a decrease at day 84 after injury (p ≤ 0.001).

Our findings suggest that TGF-β may have a role in the increased bone turnover and attendant complications seen in patients with acute injuries to the spinal cord.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 12 | Pages 1660 - 1665
1 Dec 2006
Surendran S Kim SH Jee BK Ahn SH Gopinathan P Han CW

We stably transfected early passage chondrocytes with an anti-apoptotic Bcl-2 gene in vitro using a retrovirus vector. Samples of articular cartilage were obtained from 11 patients with a mean age of 69 years (61 to 75) who were undergoing total knee replacement for osteoarthritis. The Bcl-2-gene-transfected chondrocytes were compared with non-transfected and lac-Z-gene-transfected chondrocytes, both of which were used as controls. All three groups of cultured chondrocytes were incubated with nitric oxide (NO) for ten days. Using the Trypan Blue exclusion assay, an enzyme-linked immunosorbent assay and flow cytometric analysis, we found that the number of apoptotic chondrocytes was significantly higher in the non-transfected and lac-Z-transfected groups than in the Bcl-2-transfected group (p < 0.05). The Bcl-2-transfected chondrocytes were protected from NO-induced impairment of proteoglycan synthesis.

We conclude that NO-induced chondrocyte death involves a mechanism which appears to be subject to regulation by an anti-apoptotic Bcl-2 gene. Therefore, Bcl-2 gene therapy may prove to be of therapeutic value in protecting human articular chondrocytes.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 2 | Pages 203 - 205
1 Feb 2006
Krishnan SP Skinner JA Carrington RWJ Flanagan AM Briggs TWR Bentley G

We prospectively studied the clinical, arthroscopic and histological results of collagen-covered autologous chondrocyte implantation (ACI-C) in patients with symptomatic osteochondritis dissecans of the knee. The study included 37 patients who were evaluated at a mean follow-up of 4.08 years.

Clinical results showed a mean improvement in the modified Cincinnati score from 46.1 to 68.4. Excellent and good clinical results were seen in 82.1% of those with juvenile-onset osteochondritis dissecans but in only 44.4% of those with adult-onset disease.

Arthroscopy at one year revealed International Cartilage Repair Society grades of 1 or 2 in 21 of 24 patients (87.5%). Of 23 biopsies, 11 (47.8%) showed either a hyaline-like or a mixture of hyaline-like and fibrocartilage, 12 (52.2%) showed fibrocartilage.

The age at the time of ACI-C determined the clinical outcome for juvenile-onset disease (p = 0.05), whereas the size of the defect was the major determinant of outcome in adult-onset disease (p = 0.01).


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 5 | Pages 574 - 580
1 May 2007
Delloye C Cornu O Druez V Barbier O

Bone allografts can be used in any kind of surgery involving bone from minor defects to major bone loss after tumour resection. This review describes the various types of bone grafts and the current knowledge on bone allografts, from procurement and preparation to implantation. The surgical conditions for optimising the incorporation of bone are outlined, and surgeon expectations from a bone allograft discussed.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 5 | Pages 567 - 573
1 May 2007
Keegan GM Learmonth ID Case CP

The long-term effects of metal-on-metal arthroplasty are currently under scrutiny because of the potential biological effects of metal wear debris. This review summarises data describing the release, dissemination, uptake, biological activity, and potential toxicity of metal wear debris released from alloys currently used in modern orthopaedics. The introduction of risk assessment for the evaluation of metal alloys and their use in arthroplasty patients is discussed and this should include potential harmful effects on immunity, reproduction, the kidney, developmental toxicity, the nervous system and carcinogenesis.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 10 | Pages 1309 - 1315
1 Oct 2006
Shetty N Hamer AJ Stockley I Eastell R Willkinson JM

Bisphosphonates reduce peri-prosthetic bone loss in the short term after total hip replacement but the mid- and longer term effects are not known. The aims of this randomised trial were to examine the effect of a single dose of 90 mg of pamidronate on the clinical and radiological outcome and peri-prosthetic bone mineral density in 50 patients (56 hips) over a five-year period, following total hip replacement.

At five years, 37 patients (42 hips) returned for assessment. The Harris hip scores were similar in the pamidronate and placebo groups throughout the study. Also at five years, four patients, two from each group had osteolytic lesions on plain radiography. These were located around the acetabular component in three patients and in the femoral calcar in one. The femoral and acetabular peri-prosthetic bone mineral density in the pamidronate group and the control group was similar at five years.

Pamidronate given as a single post-operative dose does not appear to influence the clinical outcome or prevent the development of osteolytic lesions at five years after total hip replacement.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 2 | Pages 189 - 195
1 Feb 2007
Levy JC Virani N Pupello D Frankle M

We report the use of the reverse shoulder prosthesis in the revision of a failed shoulder hemiarthroplasty in 19 shoulders in 18 patients (7 men, 11 women) with severe pain and loss of function. The primary procedure had been undertaken for glenohumeral arthritis associated with severe rotator cuff deficiency.

Statistically significant improvements were seen in pain and functional outcome. After a mean follow-up of 44 months (24 to 89), mean forward flexion improved by 26.4° and mean abduction improved by 35°. There were six prosthesis-related complications in six shoulders (32%), five of which had severe bone loss of the glenoid, proximal humerus or both. Three shoulders (16%) had non-prosthesis related complications.

The use of the reverse shoulder prosthesis provides improvement in pain and function for patients with failure of a hemiarthroplasty for glenohumeral arthritis and rotator cuff deficiency. However, high rates of complications were associated with glenoid and proximal humeral bone loss.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 9 | Pages 1158 - 1164
1 Sep 2007
Lusty PJ Watson A Tuke MA Walter WL Walter WK Zicat B

We studied 33 third generation, alumina ceramic-on-ceramic bearings retrieved from cementless total hip replacements after more than six months in situ. Wear volume was measured with a Roundtest machine, and acetabular orientation from the anteroposterior pelvic radiograph. The overall median early wear rate was 0.1 mm3/yr for the femoral heads, and 0.04 mm3/yr for the acetabular liners. We then excluded hips where the components had migrated. In this stable subgroup of 22 bearings, those with an acetabular anteversion of < 15° (seven femoral heads) had a median femoral head wear rate of 1.2 mm3/yr, compared with 0 mm3/yr for those with an anteversion of ≥15° (15 femoral heads, p < 0.001). Even under edge loading, wear volumes with ceramic-on-ceramic bearings are small in comparison to other bearing materials. Low acetabular anteversion is associated with greater wear.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 11 | Pages 1459 - 1462
1 Nov 2005
Crawford JR Villar RN


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 9 | Pages 1173 - 1177
1 Sep 2006
Kean J Wigderowitz CA Coventry DM

We performed a double-blind, randomised controlled trial to assess the effectiveness of a continuous-infusion brachial plexus block with levobupivacaine compared with that of a standard single injection for the management of post-operative pain after surgery on the shoulder.

Eight patients were randomised to receive a pre-operative brachial plexus block using 30 ml of levobupivacaine 0.5% with adrenaline 1:200 000 followed by insertion of a 20-gauge polyamide catheter. This was connected to a disposable elastometric pump, set immediately after surgery to administer a continuous flow of levobupivacaine 0.25% at a rate of 5 ml per hour. The other eight patients were randomised to receive only the initial injection of 30 ml. The study was double-blinded with the aid of sham catheters and clamped pumps.

All patients were given regular paracetamol and were prescribed morphine through a patient-controlled analgesia pump. Motor and sensory block assessments, visual analogue scale pain scores and consumption of morphine were recorded after the operation and then at 6, 12 and 24 hours after administration of the block.

Satisfactory motor and sensory block was achieved in all patients. The mean visual analogue scale pain score at 12 hours and consumption of morphine at 24 hours after injection were significantly lower (p < 0.05) in the continuous-infusion group. This group also took longer to request their first additional analgesia and reported a significantly higher overall level of satisfaction.

Our study has shown that continuous interscalene infusion of levobupivacaine is an effective method of post-operative analgesia after major surgery of the shoulder.