Advertisement for orthosearch.org.uk
Results 1621 - 1640 of 1756
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 1 | Pages 54 - 60
1 Jan 2006
Pandit H Jenkins C Barker K Dodd CAF Murray DW

This prospective study describes the complications and survival of the first 688 Phase 3 Oxford medial unicompartmental knee replacements implanted using a minimally-invasive technique by two surgeons and followed up independently. None was lost to follow-up. We had carried out 132 of the procedures more than five years ago. The clinical assessment of 101 of these which were available for review at five years is also presented.

Nine of the 688 knees were revised: four for infection, three for dislocation of the bearing and two for unexplained pain. A further seven knees (1%) required other procedures: four had a manipulation under anaesthesia, two an arthroscopy and one a debridement for superficial infection. The survival rate at seven years was 97.3% (95% confidence interval 5.3). At five years, 96% of the patients had a good or excellent American Knee Society score, the mean Oxford knee score was 39 and the mean flexion was 133°. This study demonstrates that the minimally-invasive Oxford unicompartmental knee replacement is a reliable and effective procedure.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 3 | Pages 356 - 360
1 Mar 2005
Ohnishi K Miyamoto K Kanamori Y Kodama H Hosoe H Shimizu K

Multiple thoracic disc herniations are rare and there are few reports in the literature. Between December 1998 and July 2002, we operated on 12 patients with multiple thoracic disc herniations. All underwent an anterior decompression and fusion through a transthoracic approach. The clinical outcomes were assessed using the Frankel neurological classification and the Japanese Orthopaedic Association (JOA) score. Under the Frankel classification, two patients improved by two grades (C to E), one patient improved by one grade (C to D), while nine patients who had been classified as grade D did not change. The JOA scores improved significantly after surgery with a mean recovery rate of 44.8% ± 24.5%. Overall, clinical outcomes were excellent in two patients, good in two, fair in six and unchanged in two. Our results indicate that anterior decompression and fusion for multiple thoracic disc herniations through a transthoracic approach can provide satisfactory results.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 7 | Pages 940 - 945
1 Jul 2005
Pandit H Ward T Hollinghurst D Beard DJ Gill HS Thomas NP Murray DW

Abnormal sagittal kinematics after total knee replacement (TKR) can adversely affect functional outcome. Two important determinants of knee kinematics are component geometry and the presence or absence of a posterior-stabilising mechanism (cam-post). We investigated the influence of these variables by comparing the kinematics of a TKR with a polyradial femur with a single radius design, both with and without a cam-post mechanism.

We assessed 55 patients, subdivided into four groups, who had undergone a TKR one year earlier by using an established fluoroscopy protocol in order to examine their kinematics in vivo. The kinematic profile was obtained by measuring the patellar tendon angle through the functional knee flexion range (0° to 90°) and the results compared with 14 normal knees. All designs of TKR had abnormal sagittal kinematics compared with the normal knee. There was a significant (p < 0.05) difference between those of the two TKRs near to full extension. The presence of the cam-post mechanism did not influence the kinematics for either TKR design. These differences suggest that surface geometry is a stronger determinant of kinematics than the presence or absence of a cam-post mechanism for these two designs. This may be because the cam-post mechanism is ineffective.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 12 | Pages 1612 - 1617
1 Dec 2009
Venkatesh KP Modi HN Devmurari K Yoon JY Anupama BR Song HR

Extensive limb lengthening may be indicated in achondroplastic patients who wish to achieve a height within the normal range for their population. However, increasing the magnitude of lengthening is associated with further complications particularly adjacent joint stiffness and fractures. We studied the relationship between the magnitude of femoral lengthening and callus pattern, adjacent joint stiffness and fracture of the regenerate bone in 40 femoral lengthenings in 20 achondroplastic patients. They were divided into two groups; group A had lengthening of less than 50% and group B of more than 50% of their initial femoral length. The patterns of radiological callus formation were classified according to shape, type and features. The incidence of callus features, knee stiffness and regenerate bone fracture were analysed in the two groups. Group B was associated with an increased incidence of concave, lateral and central callus shapes, adjacent joint and stiffness and fracture. Statistically, the incidence of stiffness in adjacent joints and regenerate bone fracture was significantly associated with the magnitude of lengthening.

We suggest that careful radiological assessment of the patterns of callus formation is a useful method for the evaluation and monitoring of regenerate bone.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 8 | Pages 1029 - 1037
1 Aug 2005
Mayer HM


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 8 | Pages 1096 - 1101
1 Aug 2005
Maynou C Cassagnaud X Mestdagh H

We compared the long-term function of subscapularis after the Latarjet procedure using two surgical approaches. We treated 102 patients (106 shoulders) with a mean age of 26.8 years (15 to 51) with involuntary unidirectional recurrent instability. The operation was carried out through an L-shaped incision with trans-section of the upper two-thirds of the muscle in 69 cases and with a subscapularis split in 37. All clinical results were assessed by the Rowe and the Duplay scores and the function of subscapularis by evaluating the distance and strength at the lift-off position. Bilateral CT was performed in 77 patients for assessment of fatty degeneration. The mean follow-up was 7.5 years (2 to 15) and 18% of cases were lost to follow-up. The mean Duplay score was 82 of 100 for the L-shaped incision group and 90 of 100 for those with a subscapularis split (p = 0.02). The mean fatty degeneration score was 1.18 after an L-shaped incision compared with 0.12 after subscapularis split (p = 0.001). The subscapularis split approach is therefore recommended.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 10 | Pages 1426 - 1433
1 Oct 2005
Kobayashi T Watanabe H Yanagawa T Tsutsumi S Kayakabe M Shinozaki T Higuchi H Takagishi K

Human bone-marrow mesenchymal stem cells have an important role in the repair of musculoskeletal tissues by migrating from the bone marrow into the injured site and undergoing differentiation. We investigated the use of autologous human serum as a substitute for fetal bovine serum in the ex vivo expansion medium to avoid the transmission of dangerous transfectants during clinical reconstruction procedures.

Autologous human serum was as effective in stimulating growth of bone-marrow stem cells as fetal bovine serum. Furthermore, medium supplemented with autologous human serum was more effective in promoting motility than medium with fetal bovine serum in all cases. Addition of B-fibroblast growth factor to medium with human serum stimulated growth, but not motility. Our results suggest that autologous human serum may provide sufficient ex vivo expansion of human bone-marrow mesenchymal stem cells possessing multidifferentiation potential and may be better than fetal bovine serum in preserving high motility.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 8 | Pages 1119 - 1120
1 Aug 2008
Crowther MAA


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 8 | Pages 1007 - 1012
1 Aug 2009
Egermann M Döderlein L Schläger E Müller S Braatz F

In patients with severe quadriplegic cerebral palsy and painful hip dislocation proximal femoral resection arthroplasty can reduce pain, but the risk of heterotopic ossification is significant. We present a surgical technique of autologous capping of the femoral stump in order to reduce this risk, using the resected femoral head as the graft.

A retrospective study of 31 patients (43 hips) who had undergone proximal femoral resection arthroplasty with (29 hips) and without autologous capping (14 hips) was undertaken. Heterotopic ossification was less frequent in patients with autologous capping, and a more predictable pattern of bony overgrowth was found.

For a selected group of non-ambulatory patients with long-standing painful dislocation of the hip, we recommend femoral resection arthroplasty over more complicated reconstructive operations. The risk of heterotopic ossification, which is a major disadvantage of this operation, is reduced by autologous capping.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 12 | Pages 1631 - 1633
1 Dec 2008
Atinga M Hamer AJ

The Morquio syndrome is a rare disorder which presents with a number of musculoskeletal problems. The literature describing total knee replacement in these patients is sparse. We describe the management of a patient with bilateral instability and pain in the knees using bilateral constrained knee replacements, and followed up for five years with pre- and postoperative knee scores. We highlight the difficulties encountered and discuss the end results.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 9 | Pages 1148 - 1153
1 Sep 2009
Schreurs BW Keurentjes JC Gardeniers JWM Verdonschot N Slooff TJJH Veth RPH

We present an update of the clinical and radiological results of 62 consecutive acetabular revisions using impacted morsellised cancellous bone grafts and a cemented acetabular component in 58 patients, at a mean follow-up of 22.2 years (20 to 25). The Kaplan-Meier survivorship for the acetabular component with revision for any reason as the endpoint was 75% at 20 years (95% confidence interval (CI) 62 to 88) when 16 hips were at risk. Excluding two revisions for septic loosening at three and six years, the survivorship at 20 years was 79% (95% CI 67 to 93). With further exclusions of one revision of a well-fixed acetabular component after 12 years during a femoral revision and two after 17 years for wear of the acetabular component, the survivorship for aseptic loosening was 87% at 20 years (95% CI 76 to 97). At the final review 14 of the 16 surviving hips had radiographs available. There was one additional case of radiological loosening and four acetabular reconstructions showed progressive radiolucent lines in one or two zones.

Acetabular revision using impacted large morsellised bone chips (0.5 cm to 1 cm in diameter) and a cemented acetabular component remains a reliable technique for reconstruction, even when assessed at more than 20 years after surgery.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 8 | Pages 1119 - 1119
1 Aug 2008
Crowther MAA


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 10 | Pages 1310 - 1315
1 Oct 2009
Ibrahim SAR Hamido F Al Misfer AK Mahgoob A Ghafar SA Alhran H

A total of 218 patients with unilateral anterior cruciate ligament deficiency were randomly assigned to one of four groups. In group A an anatomical double bundle anterior cruciate ligament reconstruction was performed; group B were treated by a single bundle using an Endobutton for femoral fixation; in group C by a single bundle using RigidFix cross pins for femoral fixation; and in group D by a single bundle using a bioabsorbable TransFix II screw for femoral fixation. For tibial fixation a bioabsorbable Intrafix interference screw was used for all the groups and the graft was fashioned from the semitendinosus and gracilis tendons in all patients. In all, 18 patients were lost to follow-up. The remaining 200 were subjected to a clinical evaluation, with assessment of the anterior drawer, Lachman’s and the pivot-shift tests, and KT-1000 arthrometer measurement. They also completed the International Knee Documentation Committee, Lysholm knee and Tegner activity scores.

At a mean of 29 months (25 to 38) follow-up there were no significant differences concerning time between injury and range of movement and Lysholm knee scores among the four groups. However, the double bundle method showed significantly better results for the pivot-shift test (p = 0.002). The KT 1000 measurements showed a mean difference between the reconstructed knee and the patients’ normal knee of 1.4 mm in the double bundle group and 2.4 mm in the single bundle group; which was statistically significant. The Lachman and anterior drawer tests also showed superior results for the double bundle method. The International Knee Documentation Committee scale showed no significant difference among the groups (p < 0.001).

On clinical evaluation the double bundle group showed less laxity than the single bundle groups. However, regardless of the technique, all knees were improved by anterior cruciate ligament reconstruction compared with their pre-operative status.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 5 | Pages 612 - 615
1 May 2009
Knupp M Schuh R Stufkens SAS Bolliger L Hintermann B

We describe a retrospective review of the clinical and radiological parameters of 32 feet in 30 patients (10 men and 20 women) who underwent correction for malalignment of the hindfoot with a modified double arthrodesis through a medial approach. The mean follow-up was 21 months (13 to 37). Fusion was achieved in all feet at a mean of 13 weeks (6 to 30). Apart from the calcaneal pitch angle, all angular measurements improved significantly after surgery. Primary wound healing occurred without complications.

The isolated medial approach to the subtalar and talonavicular joints allows good visualisation which facilitated the reduction and positioning of the joints. It was also associated with fewer problems with wound healing than the standard lateral approach.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 5 | Pages 721 - 729
1 May 2005
Yanai T Ishii T Chang F Ochiai N

We produced large full-thickness articular cartilage defects in 33 rabbits in order to evaluate the effect of joint distraction and autologous culture-expanded bone-marrow-derived mesenchymal cell transplantation (ACBMT) at 12 weeks. After fixing the knee on a hinged external fixator, we resected the entire surface of the tibial plateau. We studied three groups: 1) with and without joint distraction; 2) with joint distraction and collagen gel, and 3) with joint distraction and ACBMT and collagen gel.

The histological scores were significantly higher in the groups with ACBMT collagen gel (p < 0.05). The area of regenerated soft tissue was smaller in the group allowed to bear weight (p < 0.05). These findings suggest that the repair of large defects of cartilage can be enhanced by joint distraction, collagen gel and ACBMT.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 7 | Pages 877 - 882
1 Jul 2009
Kim HT Woo SH Lee JS Cheon SJ

When the Bernese periacetabular osteotomy is performed through an anterior approach, the ischial and retroacetabular osteotomies and manual fracture of the incompletely osteotomised ischium are conducted with an incomplete view resulting in increased risk and morbidity. We have assessed the dual anteroposterior approach which appears to address this deficiency.

We compared the results of the Bernese periacetabular osteotomy performed in 11 patients (13 osteotomies) through a single anterior approach with those in 12 patients (13 osteotomies) in whom the procedure was carried out through a dual anteroposterior approach. The estimated blood loss, the length of anaesthesia, duration of surgery and radiological parameters were measured.

The mean operative time and length of anaesthesia were not significantly different in the two groups (p = 0.781 and p = 0.698, respectively). The radiological parameters improved to a similar extent in both groups after the operation but there was significantly less blood loss in the dual osteotomy group (p = 0.034).

The dual anteroposterior approach provides a direct view of the retroacetabular and ischial parts of the osteotomy, within a reasonable operating time and with minimal blood loss and gives a satisfactory outcome.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 12 | Pages 1594 - 1600
1 Dec 2009
Khan A Bunker TD Kitson JB

There are no long-term published results on the survival of a third-generation cemented total shoulder replacement. We describe a clinical and radiological study of the Aequalis total shoulder replacement for a minimum of ten years. Between September 1996 and May 1998, 39 consecutive patients underwent a primary cemented total shoulder replacement using this prosthesis. Data were collected prospectively on all patients each year, for a minimum of ten years, or until death or failure of the prosthesis. At a follow-up of at least ten years, 12 patients had died with the prosthesis intact and two had emigrated, leaving 25 available for clinical review. Of these, 13 had rheumatoid arthritis and 12 osteoarthritis. One refused radiological review leaving 24 with fresh radiographs.

Survivorship at ten years was 100% for the humeral component and 92% for the glenoid component. The incidence of lucent lines was low. No humeral component was thought to be at risk and only two glenoid components. The osteoarthritic group gained a mean 65° in forward flexion and their Constant score improved by a mean 41.4 points (13 to 55). The rheumatoid group gained a mean of 24° in flexion and their Constant score improved by 29.4 points. This difference may have been due to failure of the rotator cuff in 75% of the patients with rheumatoid arthritis.

Thus a third-generation total shoulder replacement gives an excellent result in patients with osteoarthritis and an intact rotator cuff. Patients with rheumatoid arthritis have a 75% risk of failure of the rotator cuff at ten years.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 3 | Pages 357 - 360
1 Mar 2009
Dalury DF Mason JB Murphy JA Adams MJ

Gender-specific total knee replacement has generated much interest recently. We reviewed 1970 Sigma knees implanted in 920 women and 592 men with a mean age of 69.7 years.

At a mean follow-up of 7.3 years (minimum, five years), we found minimal differences in the outcome between genders. At the final follow-up, men had a higher overall Knee Society score and more osteolysis (3.8% vs 1.1%). However, there were no significant differences between men and women in terms of complications or improvements in knee function, pain score or range of movement. The estimated ten-year survivorship was 97% in women and 98% in men (p = 0.96).

We concluded that there was little difference in outcome between the genders treated by a modern unisex design of total knee replacement in this large multicentre study.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 2 | Pages 180 - 184
1 Feb 2009
Lim HC Bae JH Hur CR Oh JK Han SH

We retrospectively evaluated eight patients who underwent arthrodesis of the knee using cannulated screws. There were six women and two men, with a mean age of 53 years. The indications for arthrodesis were failed total knee arthroplasty, septic arthritis, tuberculosis, and recurrent persistent infection. Solid union was achieved in all patients at a mean of 6.1 months. One patient required autogenous bone graft for delayed union. One suffered skin necrosis which was treated with skin grafting. The mean limb-length discrepancy was 3.1 cm. On a visual analogue scale, the mean pain score improved from 7.9 to 3.3. According to the Knee Injury and Osteoarthritis Outcome score quality of life items, the mean score improved from 38.3 pre-operatively to 76.6 at follow-up. Cannulated screws provide a high rate of union in arthrodesis of the knee with minimal complications, patient convenience, and a simple surgical technique.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 4 | Pages 463 - 468
1 Apr 2009
Fukunaga K Kobayashi A Minoda Y Iwaki H Hashimoto Y Takaoka K

The patellar clunk syndrome describes painful catching, grinding or jumping of the patella when the knee moves from a flexed to an extended position after total knee replacement (TKR). The posterior stabilised TKR had been noted to have a higher incidence of this problem. Mobile-bearing posteriorly stabilised TKRs have been introduced to improve patellar tracking and related problems by a mechanism of self-alignment. We evaluated the patellar clunk syndrome in 113 knees in 93 patients with such a TKR at a mean follow-up of 2.3 years (2.0 to 3.2). The syndrome was identified in 15 knees (13.3%).

Logistic regression analysis showed that the absolute value of the post-operative angle of patellar tilt was significantly associated with the occurrence of patellar clunk (p = 0.025). Patellar tracking should be carefully checked during surgery.