Advertisement for orthosearch.org.uk
Results 1601 - 1620 of 5422
Results per page:
Bone & Joint Research
Vol. 10, Issue 6 | Pages 354 - 362
1 Jun 2021
Luo Y Zhao X Yang Z Yeersheng R Kang P

Aims. The purpose of this study was to examine the efficacy and safety of carbazochrome sodium sulfonate (CSS) combined with tranexamic acid (TXA) on blood loss and inflammatory responses after primary total hip arthroplasty (THA), and to investigate the influence of different administration methods of CSS on perioperative blood loss during THA. Methods. This study is a randomized controlled trial involving 200 patients undergoing primary unilateral THA. A total of 200 patients treated with intravenous TXA were randomly assigned to group A (combined intravenous and topical CSS), group B (topical CSS), group C (intravenous CSS), or group D (placebo). Results. Mean total blood loss (TBL) in groups A (605.0 ml (SD 235.9)), B (790.9 ml (SD 280.7)), and C (844.8 ml (SD 248.1)) were lower than in group D (1,064.9 ml (SD 318.3), p < 0.001). We also found that compared with group D, biomarker level of inflammation, transfusion rate, pain score, and hip range of motion at discharge in groups A, B, and C were significantly improved. There were no differences among the four groups in terms of intraoperative blood loss (IBL), intramuscular venous thrombosis (IMVT), and length of hospital stay (LOS). Conclusion. The combined application of CSS and TXA is more effective than TXA alone in reducing perioperative blood loss and transfusion rates, inflammatory response, and postoperative hip pain, results in better early hip flexion following THA, and did not increase the associated venous thromboembolism (VTE) events. Intravenous combined with topical injection of CSS was superior to intravenous or topical injection of CSS alone in reducing perioperative blood loss. Cite this article: Bone Joint Res 2021;10(6):354–362


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 2 | Pages 277 - 283
1 Mar 1995
Choueka J Koval K Kummer F Crawford G Zuckerman J

We studied the biomechanical behaviour of three sliding fixation devices for trochanteric femoral fractures. These were a titanium alloy sideplate and lag screw, a titanium alloy sideplate and dome plunger with cement augmentation, and a stainless-steel sideplate and lag screw. We used 18 mildly osteoporotic cadaver femora, randomly assigned to one of the three fixation groups. Four displacement and two strain gauges were fixed to each specimen, and each femur was first tested intact (control), then as a two-part fracture and then as a four-part intertrochanteric fracture. A range of physiological loads was applied to determine load-bearing, load-sharing and head displacement. The four-part-fracture specimens were subsequently tested to failure to determine maximum fixation strengths and modes of failure. The dome-plunger group failed at a load 50% higher than that of the stainless-steel lag-screw group (p < 0.05) and at a load 20% higher than that of the titanium-alloy lag-screw group (NS). All 12 lag-screw specimens failed by cut-out through the femoral head or neck, but none of the dome-plunger group showed movement within the femoral head when tested to failure. Strain-gauge analysis showed that the dome plunger produced considerably less strain in the inferior neck and calcar region than either of the lag screws. Inferior displacement of the femoral head was greatest for the dome-plunger group, and was due to sliding of the plunger. The dome plunger with cement augmentation was able to support higher loads and did not fail by cut-out through the femoral head.(ABSTRACT TRUNCATED AT 250 WORDS)


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 4 | Pages 521 - 524
1 Jul 1994
MacMahon S Rodgers A Collins R Farrell B


The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 2 | Pages 222 - 226
1 Mar 1989
Svalastoga E Kiaer T Jensen P

We have investigated the effect of joint tamponade and of traction in extension on the oxygen and carbon dioxide tensions in the femoral head of the immature goat, using mass spectrometry. Tamponade of 75 mmHg caused the oxygen tension in the femoral head to drop from 48 +/- 4 mmHg to 29 +/- 3 mmHg. Traction in extension further decreased the oxygen tension. Both these changes were highly significant. The partial pressure of carbon dioxide increased, but to a lesser extent and only effusion together with traction gave a statistically significant effect. Our study showed that joint effusion can produce hypoxia in the bone as a result of impaired blood flow to the femoral head. The application of traction increases this haemodynamic effect.


The Journal of Bone & Joint Surgery British Volume
Vol. 68-B, Issue 3 | Pages 392 - 397
1 May 1986
Paterson M Fulford P Denham R

Review of the radiographs of 882 consecutive metal-to-polyethylene hip replacements after a mean follow-up of 6.8 years showed 72 cases (8%) of aseptic femoral loosening, all of which showed a lucent zone or black line between metal and cement. In 97% of the series this appeared within two years of the arthroplasty. Progress of loosening was unpredictable and only 24% had significant symptoms. Improved technique with methylmethacrylate cement in Stanmore prostheses had reduced loosening after two years from 7.9% to 0.4%. Methods of detection of early loosening are discussed.


The Journal of Bone & Joint Surgery British Volume
Vol. 67-B, Issue 2 | Pages 305 - 309
1 Mar 1985
Pini M Spadini E Carluccio L Giovanardi C Magnani E Ugolotti U Uggeri E

In a randomised trial we compared the effects of two different antithrombotic regimens on the incidence of venographically established deep venous thrombosis (DVT) in 83 patients undergoing surgery for fracture of the femoral neck. Group A received dextran 40 peroperatively plus 0.5 g aspirin a day beginning before operation and continuing for 10 days after. Group B received heparin calcium 5000 iu subcutaneously plus dihydroergotamine (DHE) 0.5 mg intramuscularly, given 8-hourly, beginning before operation and continuing for 10 days after. Two patients in Group A and three in Group B developed proximal DVT, while the incidence of all DVT was 33% in Group A and 29% in Group B, a difference which was not significant. Haemorrhagic complications were much more common in the dextran/aspirin group: the volume of drainage fluid, the number of patients transfused and quantity of blood transfused, and the drop in haemoglobin level were all significantly greater in Group A. We conclude that the DHE/heparin regime is preferable to dextran/aspirin because it is safer and no less effective.


The Journal of Bone & Joint Surgery British Volume
Vol. 63-B, Issue 2 | Pages 190 - 193
1 May 1981
Wientroub S Lloyd-Roberts G Fraser M


Bone & Joint Open
Vol. 2, Issue 12 | Pages 1067 - 1074
1 Dec 2021
El-Bakoury A Khedr W Williams M Eid Y Hammad AS

Aims. After failed acetabular fractures, total hip arthroplasty (THA) is a challenging procedure and considered the gold standard treatment. The complexity of the procedure depends on the fracture pattern and the initial fracture management. This study’s primary aim was to evaluate patient-reported outcome measures (PROMs) for patients who underwent delayed uncemented acetabular THA after acetabular fractures. The secondary aims were to assess the radiological outcome and the incidence of the associated complications in those patients. Methods. A total of 40 patients underwent cementless acetabular THA following failed treatment of acetabular fractures. The postoperative clinical and radiological outcomes were evaluated for all the cohort. Results. The median (interquartile range (IQR)) Oxford Hip Score (OHS) improved significantly from 9.5 (7 to 11.5), (95% confidence interval (CI) (8 to 10.6)) to 40 (39 to 44), (95% CI (40 to 43)) postoperatively at the latest follow-up (p < 0.001). It was worth noting that the initial acetabular fracture type (simple vs complex), previous acetabular treatment (ORIF vs conservative), fracture union, and restoration of anatomical centre of rotation (COR) did not affect the final OHS. The reconstructed centre of rotation (COR) was restored in 29 (72.5%) patients. The mean abduction angle in whom acetabular fractures were managed conservatively was statistically significantly higher than the surgically treated patients 42.6° (SD 7.4) vs 38° (SD 5.6)) (p = 0.032). We did not have any case of acetabular or femoral loosening at the time of the last follow-up. We had two patients with successful two-stage revision for infection with overall eight-year survival rate was 95.2% (95% CI 86.6% to 100%) with revision for any reason at a median (IQR) duration of follow-up 50 months (16 to 87) months following THA. Conclusion. Delayed cementless acetabular THA in patients with previous failed acetabular fracture treatments produces good clinical outcomes (PROMS) with excellent survivorship, despite the technically demanding nature of the procedure. The initial fracture treatment does not influence the outcome of delayed THA. In selected cases of acetabular fractures (either nondisplaced or with secondary congruency), the initial nonoperative treatment neither resulted in large acetabular defects nor required additional acetabular reconstruction at the time of THA. Cite this article: Bone Jt Open 2021;2(12):1067–1074


The Bone & Joint Journal
Vol. 103-B, Issue 7 Supple B | Pages 91 - 97
1 Jul 2021
Crawford DA Lombardi AV Berend KR Huddleston JI Peters CL DeHaan A Zimmerman EK Duwelius PJ

Aims. The purpose of this study is to evaluate early outcomes with the use of a smartphone-based exercise and educational care management system after total hip arthroplasty (THA) and demonstrate decreased use of in-person physiotherapy (PT). Methods. A multicentre, prospective randomized controlled trial was conducted to evaluate a smartphone-based care platform for primary THA. Patients randomized to the control group (198) received the institution’s standard of care. Those randomized to the treatment group (167) were provided with a smartwatch and smartphone application. PT use, THA complications, readmissions, emergency department/urgent care visits, and physician office visits were evaluated. Outcome scores include the Hip disability and Osteoarthritis Outcome Score (HOOS, JR), health-related quality-of-life EuroQol five-dimension five-level score (EQ-5D-5L), single leg stance (SLS) test, and the Timed Up and Go (TUG) test. Results. The control group was significantly younger by a mean 3.0 years (SD 9.8 for control, 10.4 for treatment group; p = 0.007), but there were no significant differences between groups in BMI, sex, or preoperative diagnosis. Postoperative PT use was significantly lower in the treatment group (34%) than in the control group (55.4%; p = 0.001). There were no statistically significant differences in complications, readmissions, or outpatient visits. The 90-day outcomes showed no significant differences in mean hip flexion between controls (101° (SD 10.8)) and treatment (100° (SD 11.3); p = 0.507) groups. The HOOS, JR scores were not significantly different between control group (73 points (SD 13.8)) and treatment group (73.6 points (SD 13); p = 0.660). Mean 30-day SLS time was 22.9 seconds (SD 19.8) in the control group and 20.7 seconds (SD 19.5) in the treatment group (p = 0.342). Mean TUG time was 11.8 seconds (SD 5.1) for the control group and 11.9 (SD 5) seconds for the treatment group (p = 0.859). Conclusion. The use of the smartphone care management system demonstrated similar early outcomes to those achieved using traditional care models, along with a significant decrease in PT use. Noninferiority was demonstrated with regard to complications, readmissions, and ED and urgent care visits. This technology allows patients to rehabilitate on a more flexible schedule and avoid unnecessary healthcare visits, as well as potentially reducing overall healthcare costs. Cite this article: Bone Joint J 2021;103-B(7 Supple B):91–97


Bone & Joint Open
Vol. 2, Issue 2 | Pages 103 - 110
1 Feb 2021
Oussedik S MacIntyre S Gray J McMeekin P Clement ND Deehan DJ

Aims. The primary aim is to estimate the current and potential number of patients on NHS England orthopaedic elective waiting lists by November 2020. The secondary aims are to model recovery strategies; review the deficit of hip and knee arthroplasty from National Joint Registry (NJR) data; and assess the cost of returning to pre-COVID-19 waiting list numbers. Methods. A model of referral, waiting list, and eventual surgery was created and calibrated using historical data from NHS England (April 2017 to March 2020) and was used to investigate the possible consequences of unmet demand resulting from fewer patients entering the treatment pathway and recovery strategies. NJR data were used to estimate the deficit of hip and knee arthroplasty by August 2020 and NHS tariff costs were used to calculate the financial burden. Results. By November 2020, the elective waiting list in England is predicted to be between 885,286 and 1,028,733. If reduced hospital capacity is factored into the model, returning to full capacity by November, the waiting list could be as large as 1.4 million. With a 30% increase in productivity, it would take 20 months if there was no hidden burden of unreferred patients, and 48 months if there was a hidden burden, to return to pre-COVID-19 waiting list numbers. By August 2020, the estimated deficits of hip and knee arthroplasties from NJR data were 18,298 (44.8%) and 16,567 (38.6%), respectively, compared to the same time period in 2019. The cost to clear this black log would be £198,811,335. Conclusion. There will be up to 1.4 million patients on elective orthopaedic waiting lists in England by November 2020, approximate three-times the pre-COVID-19 average. There are various strategies for recovery to return to pre-COVID-19 waiting list numbers reliant on increasing capacity, but these have substantial cost implications. Cite this article: Bone Jt Open 2021;2(2):103–110


The Bone & Joint Journal
Vol. 103-B, Issue 7 Supple B | Pages 3 - 8
1 Jul 2021
Roberts HJ Barry J Nguyen K Vail T Kandemir U Rogers S Ward D

Aims. While interdisciplinary protocols and expedited surgical treatment improve the management of hip fractures in the elderly, the impact of such interventions on patients specifically undergoing arthroplasty for a femoral neck fracture is not clear. We sought to evaluate the efficacy of an interdisciplinary protocol for the management of patients with a femoral neck fracture who are treated with an arthroplasty. Methods. In 2017, our institution introduced a standardized interdisciplinary hip fracture protocol. We retrospectively reviewed adult patients who underwent hemiarthroplasty (HA) or total hip arthroplasty (THA) for femoral neck fracture between July 2012 and March 2020, and compared patient characteristics and outcomes between those treated before and after the introduction of the protocol. Results. A total of 157 patients were treated before the introduction of the protocol (35 (22.3%) with a THA), and 114 patients were treated after its introduction (37 (32.5%) with a THA). The demographic details and medical comorbidities were similar in the two groups. Patients treated after the introduction of the protocol had a significantly reduced median time between admission and surgery (22.8 hours (interquartile range (IQR) 18.8 to 27.7) compared with 24.8 hours (IQR 18.4 to 43.3) (p = 0.042), and a trend towards a reduced mean time to surgery (24.1 hours (SD 10.7) compared with 46.5 hours (SD 165.0); p = 0.150), indicating reduction in outliers. Patients treated after the introduction of the protocol had a significantly decreased rate of major complications (4.4% vs 17.2%; p = 0.005), decreased median hospital length of stay in hospital (4.0 days vs 4.8 days; p = 0.008), increased rate of discharge home (26.3% vs 14.7%; p = 0.030), and decreased one-year mortality (14.7% vs 26.3%; p = 0.049). The 90-day readmission rate (18.2% vs 21.7%; p = 0.528) and 30-day mortality (3.7% vs 5.1%; p = 0.767) did not significantly differ. Patients who underwent HA were significantly older than those who underwent THA (82.1 years (SD 10.4) vs 71.1 years (SD 9.5); p < 0.001), more medically complex (mean Charlson Comorbidity Index 6.4 (SD 2.6) vs 4.1 (SD 2.2); p < 0.001), and more likely to develop delirium (8.5% vs 0%; p = 0.024). Conclusion. The introduction of an interdisciplinary protocol for the management of elderly patients with a femoral neck fracture was associated with reduced time to surgery, length of stay, complications, and one-year mortality. Such interventions are critical in improving outcomes and reducing costs for an ageing population. Cite this article: Bone Joint J 2021;103-B(7 Supple B):3–8


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 7 | Pages 1075 - 1081
1 Sep 2001
Doherty AT Howell RT Ellis LA Bisbinas I Learmonth ID Newson R Case CP

The long-term biological effects of wear debris are unknown. We have investigated whether there is any evidence of cumulative mutagenic damage in peripheral blood lymphocytes of patients undergoing revision arthroplasty of predominantly metal-on-plastic total hip replacements compared with those at primary arthroplasty.

There was a threefold increase in aneuploidy and a twofold increase in chromosomal translocations which could not be explained by the confounding variables of smoking, gender, age and diagnostic radiographs. In the patients with TiVaAl prostheses there was a fivefold increase in aneuploidy but no increase in chromosomal translocations. By contrast, in patients with cobalt-chrome prostheses there was a 2.5-fold increase in aneuploidy and a 3.5-fold increase in chromosomal translocations. In six patients with stainless-steel prostheses there was no increase in either aneuploidy or chromosomal translocations.

Our results suggest that future epidemiological studies of the putative long-term risks of joint replacement should take into account the type of alloy used in the prosthesis.


Bone & Joint Open
Vol. 2, Issue 11 | Pages 951 - 957
16 Nov 2021
Chuntamongkol R Meen R Nash S Ohly NE Clarke J Holloway N

Aims. The aim of this study was to surveil whether the standard operating procedure created for the NHS Golden Jubilee sufficiently managed COVID-19 risk to allow safe resumption of elective orthopaedic surgery. Methods. This was a prospective study of all elective orthopaedic patients within an elective unit running a green pathway at a COVID-19 light site. Rates of preoperative and 30-day postoperative COVID-19 symptoms or infection were examined for a period of 40 weeks. The unit resumed elective orthopaedic services on 29 June 2020 at a reduced capacity for a limited number of day-case procedures with strict patient selection criteria, increasing to full service on 29 August 2020 with no patient selection criteria. Results. A total of 2,373 cases were planned in the 40-week study period. Surgery was cancelled in 59 cases, six (10.2%) of which were due to having a positive preoperative COVID-19 screening test result. Of the remaining 2,314, 996 (43%) were male and 1,318 (57%) were female. The median age was 67 years (interquartile range 59.2 to 74.6). The median American Society of Anesthesiologists grade was 2. Hip and knee arthroplasties accounted for the majority of the operations (76%). Six patients tested positive for COVID-19 preoperatively (0.25%) and 39 patients were tested for COVID-19 within 30 days after discharge, with only five patients testing positive (0.22%). Conclusion. Through strict application of a COVID-19 green pathway, elective orthopaedic surgery could be safely delivered to a large number of patients with no selection criteria. Cite this article: Bone Jt Open 2021;2(11):951–957


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 4 | Pages 598 - 603
1 May 2001
Nevelos JE Prudhommeaux F Hamadouche M Doyle C Ingham E Meunier A Nevelos AB Sedel L Fisher J

We compared and quantified the modes of failure and patterns of wear of 11 Mittelmeier and 11 Ceraver-Ostal retrieved alumina-alumina hip prostheses with reference to the corresponding clinical and radiological histories.

Macroscopic wear was assessed using a three-dimensional co-ordinate measuring machine. Talysurf contacting profilometry was used to measure surface roughness on a microscopic scale and SEM to determine mechanisms of wear at the submicron level.

The components were classified into one of three categories of wear: low (no visible/measurable wear), stripe (elliptical wear stripe on the heads and larger worn areas on the cups) and severe (macroscopic wear, large volumes of material lost). Overall, the volumetric wear of the alumina-alumina prostheses was substantially less than the widely used metal and ceramic-on-polyethylene combinations. By identifying and eliminating the factors which accelerate wear, it is expected that the lifetime of these devices can be further increased.


Bone & Joint Research
Vol. 10, Issue 10 | Pages 629 - 638
20 Oct 2021
Hayashi S Hashimoto S Kuroda Y Nakano N Matsumoto T Ishida K Shibanuma N Kuroda R

Aims. This study aimed to evaluate the accuracy of implant placement with robotic-arm assisted total hip arthroplasty (THA) in patients with developmental dysplasia of the hip (DDH). Methods. The study analyzed a consecutive series of 69 patients who underwent robotic-arm assisted THA between September 2018 and December 2019. Of these, 30 patients had DDH and were classified according to the Crowe type. Acetabular component alignment and 3D positions were measured using pre- and postoperative CT data. The absolute differences of cup alignment and 3D position were compared between DDH and non-DDH patients. Moreover, these differences were analyzed in relation to the severity of DDH. The discrepancy of leg length and combined offset compared with contralateral hip were measured. Results. The mean values of absolute differences (postoperative CT-preoperative plan) were 1.7° (standard deviation (SD) 2.0) (inclination) and 2.5° (SD 2.1°) (anteversion) in DDH patients, and no significant differences were found between non-DDH and DDH patients. The mean absolute differences for 3D cup position were 1.1 mm (SD 1.0) (coronal plane) and 1.2 mm (SD 2.1) (axial plane) in DDH patients, and no significant differences were found between two groups. No significant difference was found either in cup alignment between postoperative CT and navigation record after cup screws or in the severity of DDH. Excellent restoration of leg length and combined offset were achieved in both groups. Conclusion. We demonstrated that robotic-assisted THA may achieve precise cup positioning in DDH patients, and may be useful in those with severe DDH. Cite this article: Bone Joint Res 2021;10(10):629–638


The Bone & Joint Journal
Vol. 103-B, Issue 2 | Pages 321 - 328
1 Feb 2021
Vandeputte F Vanbiervliet J Sarac C Driesen R Corten K

Aims. Optimal exposure through the direct anterior approach (DAA) for total hip arthroplasty (THA) conducted on a regular operating theatre table is achieved with a standardized capsular releasing sequence in which the anterior capsule can be preserved or resected. We hypothesized that clinical outcomes and implant positioning would not be different in case a capsular sparing (CS) technique would be compared to capsular resection (CR). Methods. In this prospective trial, 219 hips in 190 patients were randomized to either the CS (n = 104) or CR (n = 115) cohort. In the CS cohort, a medial based anterior flap was created and sutured back in place at the end of the procedure. The anterior capsule was resected in the CR cohort. Primary outcome was defined as the difference in patient-reported outcome measures (PROMs) after one year. PROMs (Harris Hip Score (HHS), Hip disability and Osteoarthritis Outcome Score (HOOS), and Short Form 36 Item Health Survey (SF-36)) were collected preoperatively and one year postoperatively. Radiological parameters were analyzed to assess implant positioning and implant ingrowth. Adverse events were monitored. Results. At one year, there was no difference in HSS (p = 0.728), HOOS (Activity Daily Life, p = 0.347; Pain, p = 0.982; Quality of Life, p = 0.653; Sport, p = 0.994; Symptom, p = 0.459), or SF-36 (p = 0.338). Acetabular component inclination (p = 0.276) and anteversion (p = 0.392) as well as femoral component alignment (p = 0.351) were similar in both groups. There were no dislocations, readmissions, or reoperations in either group. The incidence of psoas tendinitis was six cases in the CS cohort (6%) and six cases in the CR cohort (5%) (p = 0.631). Conclusion. No clinical differences were found between resection or preservation of the anterior capsule when performing a primary THA through the DAA on a regular theatre table. In case of limited visibility during the learning curve, it might be advisable to resect a part of the anterior capsule. Cite this article: Bone Joint J 2021;103-B(2):321–328


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 1 | Pages 107 - 109
1 Jan 1995
Moens P Lammens J Molenaers G Fabry G

We describe a technique of femoral derotation osteotomy performed according to the Ilizarov principles of percutaneous corticotomy and fixation with a frame. We performed 24 femoral osteotomies in 16 patients, four with cerebral palsy and 12 with idiopathic femoral anteversion. All had rapid union and there were few complications. The advantages of the method include early ambulation, good control of rotation and axial alignment, and minimal scarring.


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 5 | Pages 775 - 778
1 Sep 1992
Stranks G MacKenzie N Grover M Fail T

We performed a prospective randomised controlled trial of the A-V Impulse System in 82 patients treated by hemiarthroplasty for subcapital fracture of the femoral neck. The incidence of proximal deep-vein thrombosis as assessed by Doppler ultrasonography was 23% in the control group and 0% in those using the device (p less than 0.01). Calf and thigh circumferences were measured in both groups at seven to ten days after operation. In the treatment group there was a mean relative reduction of postoperative swelling of the thigh by 3.27 cm (p less than 0.001) and of the calf by 1.55 cm (p less than 0.001). The A-V Impulse System appears to be a safe and effective method of reducing the incidence of proximal deep-vein thrombosis, and of postoperative swelling.


Bone & Joint Open
Vol. 2, Issue 5 | Pages 278 - 292
3 May 2021
Miyamoto S Iida S Suzuki C Nakatani T Kawarai Y Nakamura J Orita S Ohtori S

Aims. The main aims were to identify risk factors predictive of a radiolucent line (RLL) around the acetabular component with an interface bioactive bone cement (IBBC) technique in the first year after THA, and evaluate whether these risk factors influence the development of RLLs at five and ten years after THA. Methods. A retrospective review was undertaken of 980 primary cemented THAs in 876 patients using cemented acetabular components with the IBBC technique. The outcome variable was any RLLs that could be observed around the acetabular component at the first year after THA. Univariate analyses with univariate logistic regression and multivariate analyses with exact logistic regression were performed to identify risk factors for any RLLs based on radiological classification of hip osteoarthritis. Results. RLLs were detected in 27.2% of patients one year postoperatively. In multivariate regression analysis controlling for confounders, atrophic osteoarthritis (odds ratio (OR) 2.17 (95% confidence interval (CI), 1.04 to 4.49); p = 0.038) and 26 mm (OR 3.23 (95% CI 1.85 to 5.66); p < 0.001) or 28 mm head diameter (OR 3.64 (95% CI 2.07 to 6.41); p < 0.001) had a significantly greater risk for any RLLs one year after surgery. Structural bone graft (OR 0.19 (95% CI 0.13 to 0.29) p < 0.001) and location of the hip centre within the true acetabular region (OR 0.15 (95% CI 0.09 to 0.24); p < 0.001) were significantly less prognostic. Improvement of the cement-bone interface including complete disappearance and poorly defined RLLs was identified in 15.1% of patients. Kaplan-Meier survival analysis for the acetabular component at ten years with revision of the acetabular component for aseptic loosening as the end point was 100.0% with a RLL and 99.1% without a RLL (95% CI 97.9 to 100). With revision of the acetabular component for any reason as the end point, the survival rate was 99.2% with a RLL (95% CI 97.6 to 100) and 96.5% without a RLL (95% CI 93.4 to 99.7). Conclusion. This study demonstrates that acetabular bone quality, head diameter, structural bone graft, and hip centre position may influence the presence of the any RLL. Cite this article: Bone Joint Open 2021;2(5):278–292


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 7 | Pages 1085 - 1086
1 Sep 2003
AVCI S