header advert
Results 141 - 160 of 284
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 4 | Pages 565 - 571
1 May 2003
Jones S Hosalkar HS Hill RA Hartley J

We have treated seven children with relapsed infantile Blount’s disease by elevation of the hemiplateau using the Ilizarov frame.

Three boys and four girls with a mean age of 10.5 years were reviewed at a mean of 29 months after surgery. All had improved considerably and were pleased with the results. The improvements in radiological measurements were statistically significant (p < 0.001). Three-dimensional CT reconstruction was useful for planning surgery. There were no major complications. The advantages of this technique are that in addition to elevation of the hemiplateau, rotational deformities and limb-length discrepancies may be addressed.


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 4 | Pages 578 - 583
1 May 2003
Hosalkar HS Jones DH Offiah A Hall C

The association between vitamin-D-resistant rickets and linear sebaceous naevus syndrome is extremely rare. Only eight cases have been described in the English literature and in none were the skeletal aspects addressed. We present three new cases and describe the musculoskeletal features. The details and outcome of surgery for correction of the deformities are discussed. The disturbances of metabolism of vitamin D and the effects of pharmacological treatment are also described.


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 2 | Pages 261 - 264
1 Mar 2003
Hosalkar HS Jones S Chowdhury M Hartley J Hill RA

We review the results of a modified quadricepsplasty in five children who developed stiffness of the knee after femoral lengthening for congenital short femur using an Ilizarov external fixator which spanned the knee.

All had a full range of movement of the knee before lengthening was undertaken. Unifocal lengthening was carried out in the distal metaphysiodiaphyseal region of the distal femur with a mean gain of 6.5 cm. The mean percentage lengthening was 24%.

At the end of one year after removal of the Ilizarov frame and despite intensive physiotherapy all patients had stiffness. Physiotherapy was continued after the quadricepsplasty and, at the latest follow-up (mean 27 months), the mean active flexion was 102° (80 to 130). The gain in movement ranged from 50° to 100°. One patient had a superficial wound infection which settled after a course of oral antibiotics. None developed an increased extension lag after surgery and all were very satisfied with the results. Quadricepsplasty is a useful procedure for stiffness of the knee after femoral lengthening which has not responded to physiotherapy.


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 2 | Pages 309 - 309
1 Mar 2003
WHITE SH JONES P HARCOURT WGV


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 7 | Pages 1088 - 1088
1 Sep 2002
Jones D


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 7 | Pages 991 - 993
1 Sep 2002
Jasani V Richards P Wynn-Jones C

Residual pain after total hip due to a number of causes both local to and replacement may be distant from the hip. We describe pain related to the psoas muscle after total hip replacement in nine patients. All presented with characteristic symptoms. We describe the key features and management. Gratifying results were achieved with treatment. This diagnosis should be considered when assessing patients with pain after total hip replacement.


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 6 | Pages 858 - 860
1 Aug 2002
Reed MR Bliss W Sher JL Emmerson KP Jones SMG Partington PF

We undertook a prospective, randomised study of 135 total knee arthroplasties to determine the most accurate and reliable technique for alignment of the tibial prosthesis. Tibial resection was guided by either intramedullary or extramedullary alignment jigs.

Of the 135 knees, standardised postoperative radiographs suitable for assessment were available in 100. Correct tibial alignment was found in 85% of the intramedullary group compared with 65% of the extramedullary group (p = 0.019).

We conclude that intramedullary guides are superior to extramedullary instruments for alignment of the tibial prosthesis.


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 1 | Pages 151 - 151
1 Jan 2002
Jones JWM Eckersley JRT


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 4 | Pages 619 - 621
1 May 2001
ALI F JONES S SHELBROOKE K


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 3 | Pages 448 - 458
1 Apr 2001
Jones LC Frondoza C Hungerford DS

The pathogenesis of aseptic loosening of total joint prostheses is not clearly understood. Two features are associated with loosened prostheses, namely, particulate debris and movement of the implant. While numerous studies have evaluated the cellular response to particulate biomaterials, few have investigated the influence of movement of the implant on the biological response to particles. Our aim was therefore to test the hypothesis that excessive mechanical stimulation of the periprosthetic tissues induces an inflammatory response and that the addition of particulate biomaterials intensifies this.

We allocated 66 adult Beagle dogs to four groups as follows: stable implants with (I) and without (II) particulate polymethylmethacrylate (PMMA) and moving implants with (III) and without (IV) particulate PMMA. They were then evaluated at 2, 4, 6, 12 and 24 weeks.

The stable implants were well tolerated and a thin, fibrous membrane of connective tissue was observed. There was evidence of positive staining in some cells for interleukin-6 (IL-6). Addition of particulate PMMA around the stable implants resulted in an increase in the fibroblastic response and positive staining for IL-6 and tumour necrosis factor-alpha (TNF-α). By contrast, movement of the implant resulted in an immediate inflammatory response characterised by large numbers of histiocytes and cytokine staining for IL-1ß, TNF-α and IL-6. Introduction of particulate PMMA aggravated this response. Animals with particulate PMMA and movement of the implant have an intense inflammatory response associated with accelerated bone loss.

Our results indicate that the initiation of the inflammatory response to biomaterial particles was much slower than that to gross mechanical instability. Furthermore, when there was both particulate debris and movement, there was an amplification of the adverse tissue response as evidenced by the presence of osteolysis and increases in the presence of inflammatory cells and their associated cytokines.


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 3 | Pages 345 - 347
1 Apr 2001
Harcourt WGV White SH Jones P

There is a need for the accurate measurement of the outcome after knee surgery. The Oxford Knee Score is being increasingly used since it is reported to be short, simple, inexpensive and validated.

We sent the questionnaire to 346 patients awaiting surgery to the hip or lumbar spine. Only 11% of 141 patients with proximal pathology who denied knee problems gave a maximum score. Their mean score was substantially lower than expected at 28.7 (maximum 48), and was significantly lower than the score of 36.5 obtained from patients after total knee replacement.

We therefore suggest that the frequent coexistence of hip or spinal pathology will significantly alter both the absolute score and any improvement to be expected after knee surgery. Although sensitive to disability originating from the knee the Oxford Knee Score is not sufficiently specific since it is heavily influenced by more proximal pathology.


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 1 | Pages 106 - 111
1 Jan 2001
Brown R Hussain M McHugh K Novelli V Jones D

Discitis is uncommon in children and presents in different ways at different ages. It is most difficult to diagnose in the uncommunicative toddler of one to three years of age. We present 11 consecutive cases. The non-specific clinical features included refusal to walk (63%), back pain (27%), inability to flex the lower back (50%) and a loss of lumbar lordosis (40%). Laboratory tests were unhelpful and cultures of blood and disc tissue were negative.

MRI reduces the diagnostic delay and may help to avoid the requirement for a biopsy. In 75% of cases it demonstrated a paravertebral inflammatory mass, which helped to determine the duration of the oral therapy given after initial intravenous antibiotics.

At a mean follow-up of 21 months (10 to 40), all the spines were mobile and the patients free from pain. Radiological fusion occurred in 20% and was predictable after two years. At follow-up, MRI showed variable appearances: changes in the vertebral body usually resolved at 24 months and recovery of the disc was seen after 34 months.


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 8 | Pages 1204 - 1204
1 Nov 2000
JONES S ALI F FERNDANDES J


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 8 | Pages 1207 - 1207
1 Nov 2000
JONES DH


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 7 | Pages 1083 - 1083
1 Sep 2000
JONES DHA


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 7 | Pages 1085 - 1085
1 Sep 2000
JONES S ALI F FERNDANDEZ J


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 2 | Pages 160 - 164
1 Mar 2000
Jones DH Dezateux CA Danielsson LG Paton RW Clegg J


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 6 | Pages 991 - 994
1 Nov 1999
Morgan-Jones RL Cross MJ

Thirty cruciate ligaments were retrieved from either cadavers or limbs which had been amputated. Each specimen was sectioned and stained to demonstrate the presence of collagen, nerves and vessels.

All 30 specimens contained an interconnecting band of collagen fibres between the anterior and posterior cruciate ligaments. Vascular structures were present in all specimens and nerve fibres were identified in 26 (86%). We have called this structure the ‘intercruciate band’. The anterior and posterior cruciate ligaments should no longer be thought of in isolation, but together as a ‘cruciate complex’.


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 6 | Pages 1023 - 1028
1 Nov 1999
Williams PR Jones DA Bishay M

Between January 1987 and December 1988 there were 7575 births in the Swansea maternity unit. Of these 823 (10.9%) were considered to be at ‘high risk’ for developmental dysplasia of the hip (DDH). Static ultrasound examination was performed in each case and the results classified on the basis of the method of Graf. A total of 117 type III–IV hips in 83 infants was splinted using the Aberdeen splint.

Radiographs of these hips were taken at six and 12 months. Hilgenreiner’s measurements of the acetabular angle were made in all cases and the development of the femoral capital epiphysis was assessed by measuring the epiphyseal area. The effect of splintage on the acetabular angle and the epiphyseal area between the normal and abnormal splinted hips was compared. Radiographs of 16 normal infants (32 normal unsplinted hips) were used as a control group.

This cohort has now been followed up for a minimum of nine years. There have been no complications as a result of splintage. The failure rate was 1.7% or 0.25 per 1000 live births. No statistical difference was found when comparing the effect of splintage on the acetabular angle and epiphyseal area between normal and abnormal splinted hips and normal unsplinted hips.

Our study has shown that while the Aberdeen splint had a definite but small failure rate, it was safe in that it did not produce avascular necrosis. The current conventional view that a low rate of splintage is always best is therefore brought into question if the Aberdeen splint is chosen for the management of neonatal DDH.


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 4 | Pages 744 - 744
1 Jul 1999
JONES D