Recent improvements in surgical technique and perioperative blood management after total joint replacement (TJR) have decreased rates of transfusion. However, as many surgeons transition to outpatient TJR, obtaining routine postoperative blood tests becomes more challenging. Therefore, we sought to determine if a preoperative outpatient assessment tool that stratifies patients based on numerous medical comorbidities could predict who required postoperative haemoglobin (Hb) measurement. We performed a prospective study of consecutive unilateral primary total knee arthroplasties (TKAs) and total hip arthroplasties (THAs) performed at a single institution. Prospectively collected data included preoperative and postoperative Hb levels, need for blood transfusion, length of hospital stay, and Outpatient Arthroplasty Risk Assessment (OARA) score.Aims
Methods
The objective of this study was to compare the two-year migration pattern and clinical outcomes of a total knee arthroplasty (TKA) with an asymmetrical tibial design (Persona PS) and a well-proven TKA with a symmetrical tibial design (NexGen LPS). A randomized controlled radiostereometric analysis (RSA) trial was conducted including 75 cemented posterior-stabilized TKAs. Implant migration was measured with RSA. Maximum total point motion (MTPM), translations, rotations, clinical outcomes, and patient-reported outcome measures (PROMs) were assessed at one week postoperatively and at three, six, 12, and 24 months postoperatively.Aims
Methods
We report the medium-term outcomes of a consecutive series of 118 Zenith total ankle arthroplasties (TAAs) from a single, non-designer centre. Between December 2010 and May 2016, 118 consecutive Zenith prostheses were implanted in 114 patients. Demographic, clinical, and patient-reported outcome measures (PROMs) data were collected. The endpoint of the study was failure of the implant requiring revision of one or all of the components. Kaplan-Meier survival curves were generated with 95% confidence intervals (CIs) and the rate of failure calculated for each year.Aims
Methods
A randomised prospective trial was undertaken of antibiotic prophylaxis given at various intervals before inflation of the
We present three young men who sustained closed diaphyseal fracture of the tibia and later developed severe osteocutaneous necrosis induced by heat during intramedullary reaming. They all had a narrow medullary cavity and in all a
For many designs of total knee arthroplasty (TKA) it remains unclear whether cemented or uncemented fixation provides optimal long-term survival. The main limitation in most studies is a retrospective or non-comparative study design. The same is true for comparative trials looking only at the survival rate as extensive sample sizes are needed to detect true differences in fixation and durability. Studies using radiostereometric analysis (RSA) techniques have shown to be highly predictive in detecting late occurring aseptic loosening at an early stage. To investigate the difference in predicted long-term survival between cemented, uncemented, and hybrid fixation of TKA, we performed a randomized controlled trial using RSA. A total of 105 patients were randomized into three groups (cemented, uncemented, and hybrid fixation of the ACS Mobile Bearing (ACS MB) knee system, implantcast). RSA examinations were performed on the first day after surgery and at scheduled follow-up visits at three months, six months, one year, and two years postoperatively. Patient-reported outcome measures (PROMs) were obtained preoperatively and after two years follow-up. Patients and follow-up investigators were blinded for the result of randomization.Aims
Methods
Modern total knee arthroplasty (TKA) prostheses are designed to restore near normal kinematics including high flexion. Kneeling is a high flexion, kinematically demanding activity after TKA. The debate about design choice has not yet been informed by six-degrees-of-freedom in vivo kinematics. This prospective randomized clinical trial compared kneeling kinematics in three TKA designs. In total, 68 patients were randomized to either a posterior stabilized (PS-FB), cruciate-retaining (CR-FB), or rotating platform (CR-RP) design. Of these patients, 64 completed a minimum one year follow-up. Patients completed full-flexion kneeling while being imaged using single-plane fluoroscopy. Kinematics were calculated by registering the 3D implant models onto 2D-dynamic fluoroscopic images and exported for analysis.Aims
Methods
Free osteocutaneous fibular grafts, revascularised by microvascular anastomoses, have been used for one-stage reconstruction of extensive bone and skin loss in the lower leg in seven patients. The addition of an integral skin flap to a vascularised fibular graft makes reconstruction of bone defects with significant skin loss possible, and the technique for designing and raising such a flap is presented. The advantages of this transfer over other microvascular osteocutaneous flaps are the available length of straight cortical bone, the large thin skin flap, the good diameter of the vascular pedicle and the fact that dissection is carried out under a
Fixation of scaphoid nonunion with a volar locking plate and cancellous bone grafting has been shown to be a successful technique in small series. Few mid- or long-term follow-up studies have been reported. The aim of this study was to report the mid-term radiological and functional outcome of plate fixation for scaphoid nonunion. Patients with a scaphoid nonunion were prospectively enrolled and treated with open reduction using a volar approach, debridement of the nonunion, and fixation using a locking plate and cancellous bone grafting, from the ipsilateral iliac crest. Follow-up included examination, functional assessment using the patient-rated wrist/hand evaluation (PRWHE), and multiplanar reformation CT scans at three-month intervals until union was confirmed.Aims
Methods
Over a 25-year period, 12 patients had from 2.5 to 5.1 cm operative shortening of the tibia and fibula for leg length discrepancy at between four and 18 years of age. All recovered normal function and there was minor cosmetic impairment in only two cases. The only vascular complication was temporary delay in return of the circulation to the foot after
A prospective single-cohort study was designed to include 20 patients with enchondromas but was stopped because of poor early results. Four patients with an enchondroma, three in the proximal humerus and one in the distal femur, were treated by curettage and filling of the defect with Norian SRS cement. Clinical and radiological follow-up including CT and MRI was carried out for 18 months. All three patients with lesions in the proximal humerus had severe pain and limited movement of the shoulder. The radiological and CT appearances of the cement were unchanged at follow-up. There were characteristic appearances of synovitis and periosteitis on MRI in two patients. Since the cement induces a soft-tissue reaction the bony cavity should be sealed with the curetted and burred bone after curettage and introduction of Norian cement, especially in sites where a
1. Three new cases of injury to main arteries at orthopaedic operations are described, and a follow-up of two previously described cases is given. The rarity of these accidents is a credit to those engaged in orthopaedic surgery, for many orthopaedic operations are done very close to great vessels, and often under the bloodless conditions of a
An experimental study performed in 16 mongrel dogs is presented, which shows that when venous stasis is combined with the local injection of non-esterified fatty acid an intense thrombosis results. This response is not produced by venous stasis alone, nor by the combination of venous stasis and triacylglycerol. Histologically it is quite different from the response produced by an inert intraluminal foreign body. It does resemble venous thrombosis described experimentally and in patients. The clinical relevance of these findings is that during accidental or operative trauma to a long bone, fat is commonly forced into the local venous circulation. If this event is combined with venous stasis or a
We investigated the effect of a fibrinolytic inhibitor, tranexamic acid, on blood loss and blood transfusion in knee arthroplasty by a randomised, double-blind study of 86 patients. A dose of 10 mg/kg body-weight of either tranexamic acid or placebo was given intravenously shortly before the release of the
The application of robotics in the operating theatre for knee arthroplasty remains controversial. As with all new technology, the introduction of new systems might be associated with a learning curve. However, guidelines on how to assess the introduction of robotics in the operating theatre are lacking. This systematic review aims to evaluate the current evidence on the learning curve of robot-assisted knee arthroplasty. An extensive literature search of PubMed, Medline, Embase, Web of Science, and Cochrane Library was conducted. Randomized controlled trials, comparative studies, and cohort studies were included. Outcomes assessed included: time required for surgery, stress levels of the surgical team, complications in regard to surgical experience level or time needed for surgery, size prediction of preoperative templating, and alignment according to the number of knee arthroplasties performed. A total of 11 studies met the inclusion criteria. Most were of medium to low quality. The operating time of robot-assisted total knee arthroplasty (TKA) and unicompartmental knee arthroplasty (UKA) is associated with a learning curve of between six to 20 cases and six to 36 cases respectively. Surgical team stress levels show a learning curve of seven cases in TKA and six cases for UKA. Experience with the robotic systems did not influence implant positioning, preoperative planning, and postoperative complications. Robot-assisted TKA and UKA is associated with a learning curve regarding operating time and surgical team stress levels. Future evaluation of robotics in the operating theatre should include detailed measurement of the various aspects of the total operating time, including total robotic time and time needed for preoperative planning. The prior experience of the surgical team should also be evaluated and reported. Cite this article:
Using a scintigraphic technique based on anautologous injection of . 99m. Tc-labelled erythrocytes, we have evaluated the efficiency of different exsanguination procedures in the upper limb of ten healthy male volunteers. The methods were elevation alone, the use of the Esmarch bandage or a gauze bandage, the Pomidor roll-cuff, the squeeze method and the Urias bag. The various procedures gave the following median percentage reductions of blood volumes: elevation for 5 seconds 44%, 15 seconds 45%, 30 seconds 46%, 60 seconds 46% and 4 minutes 42%, the Esmarch bandage 69%, a gauze bandage 63%, the Pomidor roll-cuff 66%, the squeeze method 53%, and the Urias bag 57%. With regard to elevation alone no significant differences were found. All the external methods were significantly more effective than elevation alone. Overall, the squeeze method was found to be the best method of exsanguination before inflation of a
Malignancy and surgery are risk factors for venous thromboembolism (VTE). We undertook a systematic review of the literature concerning the prophylactic management of VTE in orthopaedic oncology patients. MEDLINE (PubMed), EMBASE (Ovid), Cochrane, and CINAHL databases were searched focusing on VTE, deep vein thrombosis (DVT), pulmonary embolism (PE), bleeding, or wound complication rates.Aims
Methods