Advertisement for orthosearch.org.uk
Results 141 - 160 of 188
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 4 | Pages 470 - 475
1 Apr 2011
Kendrick BJL Simpson DJ Kaptein BL Valstar ER Gill HS Murray DW Price AJ

The Oxford unicompartmental knee replacement (UKR) was designed to minimise wear utilising a fully-congruent, mobile, polyethylene bearing. Wear of polyethylene is a significant cause of revision surgery in UKR in the first decade, and the incidence increases in the second decade. Our study used model-based radiostereometric analysis to measure the combined wear of the upper and lower bearing surfaces in 13 medial-compartment Oxford UKRs at a mean of 20.9 years (17.2 to 25.9) post-operatively.

The mean linear penetration of the polyethylene bearing was 1.04 mm (0.307 to 2.15), with a mean annual wear rate of 0.045 mm/year (0.016 to 0.099). The annual wear rate of the phase-2 bearings (mean 0.022 mm/year) was significantly less (p = 0.01) than that of phase-1 bearings (mean 0.07 mm/year).

The linear wear rate of the Oxford UKR remains very low into the third decade. We believe that phase-2 bearings had lower wear rates than phase-1 implants because of the improved bearing design and surgical technique which decreased the incidence of impingement. We conclude that the design of the Oxford UKR gives low rates of wear in the long term.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 4 | Pages 517 - 524
1 Apr 2011
Cox G McGonagle D Boxall SA Buckley CT Jones E Giannoudis PV

The scarcity of mesenchymal stem cells (MSCs) in iliac crest bone marrow aspirate (ICBMA), and the expense and time in culturing cells, has led to the search for alternative harvest sites. The reamer-irrigation-aspirator (RIA) provides continuous irrigation and suction during reaming of long bones. The aspirated contents pass via a filter, trapping bony fragments, before moving into a ‘waste’ bag from which MSCs have been previously isolated. We examined the liquid and solid phases, performed a novel digestion of the solid phase, and made a comparative assessment in terms of number, phenotype and differentiation capacity with matched ICBMA.

The solid fraction from the filtrate was digested for 60 minutes at 37°C with collagenase. Enumeration was performed via the colony-forming unit fibroblast (CFU-F) assay. Passage (P2) cells were differentiated towards osteogenic, adipogenic and chondrogenic lineages, and their phenotypes assessed using flow cytometry (CD33, CD34, CD45, CD73, CD90, and CD105).

MSCs from the RIA phases were able to differentiate at least as well as those from ICBMA, and all fractions had phenotypes consistent with other established sources. The median number of colonies for the three groups was: ICBMA = 8.5 (2 to 86), RIA-liquid = 19.5 (4 to 90), RIA-solid = 109 (67 to 200) per 200 μl. The mean total yield of cells for the three groups was: ICBMA = 920 (0 to 4275), RIA-liquid = 114 983 (16 500 to 477 750), RIA-solid = 12 785 (7210 to 28 475).

The RIA filtrate contains large numbers of MSCs that could potentially be extracted without enzymatic digestion and used for bone repair without prior cell expansion.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 4 | Pages 555 - 559
1 Apr 2010
Deguchi M Shinjo R Yoshioka Y Seki H

The post-operative changes in the serum levels of CRP and serum amyloid A (SAA) were investigated prospectively in 106 patients after posterior lumbar interbody fusion. In 96 patients who did not have complications related to infection within the first year after operation, the median levels of CRP before operation and on days 3, 7 and 13 after were 0.02 (0.01 to 0.03), 9.12 (2.36 to 19.82), 1.64 (0.19 to 6.10) and 0.53 (0.05 to 2.94) mg/dl, respectively and for SAA, 2.6 (2.0 to 3.8), 1312.1 (58.0 to 3579.8), 77.3 (1.8 to 478.4), 14.1 (0.5 to 71.9) μg/ml, respectively. The levels on day 3 were the highest for both CRP and SAA and significantly decreased (p < 0.01) by day 7 and day 13.

In regard to CRP, no patient had less than the reference level (0.1 mg/dl) on day 7. In only three had the level decreased to the reference level, while in 93 it was above this on day 13. However, for SAA, the levels became normal on day 7 in 10 cases and on day 13 in 34 cases. The ratios relative to the levels on day 3 were significantly lower for SAA compared with CRP on day 7 and day 13. Of the ten patients with infection in the early stages, the level of CRP decreased slightly but an increase in SAA was observed in six.

We concluded that SAA is better than CRP as a post-operative inflammatory marker.


The Bone & Joint Journal
Vol. 96-B, Issue 12 | Pages 1699 - 1705
1 Dec 2014
Boyle MJ Gao R Frampton CMA Coleman B

Our aim was to compare the one-year post-operative outcomes following retention or removal of syndesmotic screws in adult patients with a fracture of the ankle that was treated surgically. A total of 51 patients (35 males, 16 females), with a mean age of 33.5 years (16 to 62), undergoing fibular osteosynthesis and syndesmotic screw fixation, were randomly allocated to retention of the syndesmotic screw or removal at three months post-operatively. The two groups were comparable at baseline.

One year post-operatively, there was no significant difference in the mean Olerud–Molander ankle score (82.4 retention vs 86.7 removal, p = 0.367), the mean American Orthopedic Foot and Ankle Society ankle-hindfoot score (88.6 vs 90.1, p = 0.688), the mean American Academy of Orthopedic Surgeons foot and ankle score (96.3 vs 94.0, p = 0.250), the mean visual analogue pain score (1.0 vs 0.7, p = 0.237), the mean active dorsiflexion (10.2° vs 13.0°, p = 0.194) and plantar flexion (33.6° vs 31.3°, p = 0.503) of the ankle, or the mean radiological tibiofibular clear space (5.0 mm vs 5.3 mm, p = 0.276) between the two groups. A total of 19 patients (76%) in the retention group had a loose and/or broken screw one year post-operatively.

We conclude that removal of a syndesmotic screw produces no significant functional, clinical or radiological benefit in adult patients who are treated surgically for a fracture of the ankle.

Cite this article: Bone Joint J 2014;96-B:1699–1705.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 8 | Pages 1074 - 1077
1 Aug 2009
Singh VK Kalairajah Y

An intra-operative splash is a common occurrence in elective knee and hip replacement surgery and can potentially transmit bloodborne diseases, with devastating consequences. This study aimed to quantify the risk of a splash and to assess its correlation with body mass index, duration of surgery and the volume of lavage fluid used.

Between December 2007 and April 2008, 62 consecutive patients (38 women, 24 men) undergoing an elective total knee or total hip replacement (TKR, THR) were recruited into the study (32 TKRs and 30 THRs) after appropriate consent.

A splash occurred in all 62 cases. A THR had a slightly higher risk of a splash than a TKR, but this was not statistically significant (p = 0.27). The correlation between body mass index, duration of surgery and the amount of pulse lavage used with a splash was r = 0.013, (non-significant), r = 0.52, (significant) and r = 0.92 (highly significant), respectively.

A high number of splashes are generated during a TKR and a THR. The simple visor mask fails to protect the surgeon, the assistant or the patient from the risk of a splash and reverse splash, respectively.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 9 | Pages 1169 - 1177
1 Sep 2011
Underwood R Matthies A Cann P Skinner JA Hart AJ

The Articular Surface Replacement (ASR) hip resurfacing arthroplasty has a failure rate of 12.0% at five years, compared with 4.3% for the Birmingham Hip Resurfacing (BHR). We analysed 66 ASR and 64 BHR explanted metal-on-metal hip replacements with the aim of understanding their mechanisms of failure. We measured the linear wear rates of the acetabular and femoral components and analysed the clinical cause of failure, pre-revision blood metal ion levels and orientation of the acetabular component.

There was no significant difference in metal ion levels (chromium, p = 0.82; cobalt, p = 0.40) or head wear rate (p = 0.14) between the two groups. The ASR had a significantly increased rate of wear of the acetabular component (p = 0.03) and a significantly increased occurrence of edge loading (p < 0.005), which can be attributed to differences in design between the ASR and BHR. The effects of differences in design on the in vivo wear rates are discussed: these may provide an explanation as to why the ASR is more sensitive to suboptimal positioning than the BHR.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 11 | Pages 1600 - 1605
1 Nov 2010
Rimington TR Edwards SG Lynch TS Pehlivanova MB

The purposes of this study were to define the range of laxity of the interosseous ligaments in cadaveric wrists and to determine whether this correlated with age, the morphology of the lunate, the scapholunate (SL) gap or the SL angle. We evaluated 83 fresh-frozen cadaveric wrists and recorded the SL gap and SL angle. Standard arthroscopy of the wrist was then performed and the grades of laxity of the scapholunate interosseous ligament (SLIL) and the lunotriquetral interosseous ligament (LTIL) and the morphology of the lunate were recorded. Arthroscopic evaluation of the SLIL revealed four (5%) grade I specimens, 28 (34%) grade II, 40 (48%) grade III and 11 (13%) grade IV. Evaluation of the LTIL showed 17 (20%) grade I specimens, 40 (48%) grade II, 28 (30%) grade III and one (1%) grade IV.

On both bivariate and multivariate analysis, the grade of both the SLIL and LTIL increased with age, but decreased with female gender. The grades of SLIL or LTIL did not correlate with the morphology of the lunate, the SL gap or the SL angle. The physiological range of laxity at the SL and lunotriquetral joints is wider than originally described. The intercarpal ligaments demonstrate an age-related progression of laxity of the SL and lunotriquetral joints. There is no correlation between the grades of laxity of the SLIL or LTIL and the morphology of the lunate, the SL gap or the SL grade. Based on our results, we believe that the Geissler classification has a role in describing intercarpal laxity, but if used alone it cannot adequately diagnose pathological instability.

We suggest a modified classification with a mechanism that may distinguish physiological laxity from pathological instability.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 7 | Pages 963 - 969
1 Jul 2010
Suzuki M Kurimoto S Shinohara T Tatebe M Imaeda T Hirata H

We have developed an illustrated questionnaire, the Hand20, comprising 20 short and easy-to-understand questions to assess disorders of the upper limb. We have examined the usefulness of this questionnaire by comparing reliability, validity, responsiveness and the level of missing data with those of the Disabilities of the Arm, Shoulder and Hand (DASH) questionnaire.

A series of 431 patients with disorders of the upper limb completed the Hand20 and the Japanese version of the DASH (DASH-JSSH) questionnaire. The norms for Hand20 scores were determined in another cross-sectional study.

Most patients had no difficulty in completing the Hand20 questionnaire, whereas the DASH-JSSH had a significantly higher rate of missing data. The standard score for the Hand20 was smaller than the reported norms for the DASH.

Our study showed that the Hand20 questionnaire provided validation comparable with that of the DASH-JSSH. Explanatory illustrations and short questions which were easy-to-understand led to better rates of response and fewer missing data, even in elderly individuals with cognitive deterioration.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 11 | Pages 1473 - 1476
1 Nov 2008
Ibrahim T Gabbar OA El-Abed K Hutchinson MJ Nelson IW

Our aim in this prospective radiological study was to determine whether the flexibility rate calculated from radiographs obtained during forced traction under general anaesthesia, was better than that of fulcrum-bending radiographs before corrective surgery in predicting the extent of the available correction in patients with idiopathic scoliosis. We evaluated 33 patients with a Cobb angle > 60° on a standing posteroanterior radiograph, who had been treated by posterior correction. Pre-operative standing fulcrum-bending radiographs and those with forced-traction under general anaesthesia were obtained. Post-operative standing radiographs were taken after surgical correction.

The mean forced-traction flexibility rate was 55% (sd 11.3) which was significantly higher than the mean fulcrum-bending flexibility rate of 32% (sd 16.1) (p < 0.001). We found no correlation between either the forced-traction or fulcrum-bending flexibility rates and the correction rate post-operatively (p = 0.24 and p = 0.44, respectively).

Radiographs obtained during forced traction under general anaesthesia were better at predicting the flexibility of the curve than fulcrum-bending radiographs in curves with a Cobb angle > 60° in the standing position and may identify those patients for whom supplementary anterior surgery can be avoided.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 1 | Pages 136 - 141
1 Jan 2010
Franken M Grimm B Heyligers I

We have investigated the accuracy of the templating of digital radiographs in planning total hip replacement using two common object-based calibration methods with the ball placed laterally (method 1) or medially (method 2) and compared them with two non-object-based methods. The latter comprised the application of a fixed magnification of 121% (method 3) and calculation of magnification based on the object-film-distance (method 4). We studied the post-operative radiographs of 57 patients (19 men, 38 women, mean age 73 years (53 to 89)) using the measured diameter of the prosthetic femoral head and comparing it with the true value.

Both object-based methods (1 and 2) produced large errors (mean/maximum: 2.55%/17.4% and 2.04%/6.46%, respectively). Method 3 applying a fixed magnification and method 4 (object-film-distance) produced smaller errors (mean/maximum 1.42%/5.22% and 1.57%/4.24%, respectively; p < 0.01). The latter results were clinically relevant and acceptable when planning was allowed to within one implant size. Object-based calibration (methods 1 and 2) has fundamental problems with the correct placement of the calibration ball. The accuracy of the fixed magnification (method 3) matched that of object-film-distance (method 4) and was the most reliable and efficient calibration method in digital templating.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 3 | Pages 344 - 350
1 Mar 2009
Luyckx T Didden K Vandenneucker H Labey L Innocenti B Bellemans J

The purpose of this study was to test the hypothesis that patella alta leads to a less favourable situation in terms of patellofemoral contact force, contact area and contact pressure than the normal patellar position, and thereby gives rise to anterior knee pain.

A dynamic knee simulator system based on the Oxford rig and allowing six degrees of freedom was adapted in order to simulate and record the dynamic loads during a knee squat from 30° to 120° flexion under physiological conditions. Five different configurations were studied, with variable predetermined patellar heights.

The patellofemoral contact force increased with increasing knee flexion until contact occurred between the quadriceps tendon and the femoral trochlea, inducing load sharing. Patella alta caused a delay of this contact until deeper flexion. As a consequence, the maximal patellofemoral contact force and contact pressure increased significantly with increasing patellar height (p < 0.01). Patella alta was associated with the highest maximal patellofemoral contact force and contact pressure. When averaged across all flexion angles, a normal patellar position was associated with the lowest contact pressures.

Our results indicate that there is a biomechanical reason for anterior knee pain in patients with patella alta.


The Bone & Joint Journal
Vol. 96-B, Issue 1 | Pages 19 - 23
1 Jan 2014
Sabharwal S Gauher S Kyriacou S Patel V Holloway I Athanasiou T

We evaluated the quality of guidelines on thromboprophylaxis in orthopaedic surgery by examining how they adhere to validated methodological standards in their development. A structured review was performed for guidelines that were published between January 2005 and April 2013 in medical journals or on the Internet. A pre-defined computerised search was used in MEDLINE, Scopus and Google to identify the guidelines. The AGREE II assessment tool was used to evaluate the quality of the guidelines in the study.

Seven international and national guidelines were identified. The overall methodological quality of the individual guidelines was good. ‘Scope and Purpose’ (median score 98% interquartile range (IQR)) 86% to 98%) and ‘Clarity of Presentation’ (median score 90%, IQR 90% to 95%) were the two domains that received the highest scores. ‘Applicability’ (median score 68%, IQR 45% to 75%) and ‘Editorial Independence’ (median score 71%, IQR 68% to 75%) had the lowest scores.

These findings reveal that although the overall methodological quality of guidelines on thromboprophylaxis in orthopaedic surgery is good, domains within their development, such as ‘Applicability’ and ‘Editorial Independence’, need to be improved. Application of the AGREE II instrument by the authors of guidelines may improve the quality of future guidelines and provide increased focus on aspects of methodology used in their development that are not robust.

Cite this article: Bone Joint J 2014;96-B:19–23.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 8 | Pages 1000 - 1004
1 Aug 2008
Wraighte PJ Howard PW

Femoral impaction bone allografting has been developed as a means of restoring bone stock in revision total hip replacement. We report the results of 75 consecutive patients (75 hips) with a mean age of 68 years (35 to 87) who underwent impaction grafting using the Exeter collarless, polished, tapered femoral stem between 1992 and 1998.

The mean follow-up period was 10.5 years (6.3 to 14.1). The median pre-operative bone defect score was 3 (interquartile range (IQR) 2 to 3) using the Endo-Klinik classification.

The median subsidence at one year post-operatively was 2 mm (IQR 1 to 3). At the final review the median Harris hip score was 80.6 (IQR 67.6 to 88.9) and the median subsidence 2 mm (IQR 1 to 4). Incorporation of the allograft into trabecular bone and secondary remodelling were noted radiologically at the final follow-up in 87% (393 of 452 zones) and 40% (181 of 452 zones), respectively.

Subsidence of the Exeter stem correlated with the pre-operative Endo-Klinik bone loss score (p = 0.037). The degree of subsidence at one year had a strong association with long-term subsidence (p < 0.001). There was a significant correlation between previous revision surgery and a poor Harris Hip score (p = 0.028), and those who had undergone previous revision surgery for infection had a higher risk of complications (p = 0.048). Survivorship at 10.5 years with any further femoral operation as the end-point was 92% (95% confidence interval 82 to 97).


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 1 | Pages 38 - 46
1 Jan 2010
Langton DJ Jameson SS Joyce TJ Hallab NJ Natu S Nargol AVF

Early failure associated with adverse reactions to metal debris is an emerging problem after hip resurfacing but the exact mechanism is unclear. We analysed our entire series of 660 metal-on-metal resurfacings (Articular Surface Replacement (ASR) and Birmingham Hip Resurfacing (BHR)) and large-bearing ASR total hip replacements, to establish associations with metal debris-related failures. Clinical and radiological outcomes, metal ion levels, explant studies and lymphocyte transformation tests were performed. A total of 17 patients (3.4%) were identified (all ASR bearings) with adverse reactions to metal debris, for which revision was required. This group had significantly smaller components, significantly higher acetabular component anteversion, and significantly higher whole concentrations of blood and joint chromium and cobalt ions than asymptomatic patients did (all p < 0.001). Post-revision lymphocyte transformation tests on this group showed no reactivity to chromium or cobalt ions. Explants from these revisions had greater surface wear than retrievals for uncomplicated fractures. The absence of adverse reactions to metal debris in patients with well-positioned implants usually implies high component wear.

Surgeons must consider implant design, expected component size and acetabular component positioning in order to reduce early failures when performing large-bearing metal-on-metal hip resurfacing and replacement.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 7 | Pages 958 - 965
1 Jul 2008
Leong JJH Leff DR Das A Aggarwal R Reilly P Atkinson HDE Emery RJ Darzi AW

The aim of this study was to validate the use of three models of fracture fixation in the assessment of technical skills. We recruited 21 subjects (six experts, seven intermediates, and eight novices) to perform three procedures: application of a dynamic compression plate on a cadaver porcine model, insertion of an unreamed tibial intramedullary nail, and application of a forearm external fixator, both on synthetic bone models. The primary outcome measures were the Objective Structural Assessment of technical skills global rating scale on video recordings of the procedures which were scored by two independent expert observers, and the hand movements of the surgeons which were analysed using the Imperial College Surgical Assessment Device.

The video scores were significantly different for the three groups in all three procedures (p < 0.05), with excellent inter-rater reliability (α = 0.88). The novice and intermediate groups specifically were significantly different in their performance with dynamic compression plate and intramedullary nails (p < 0.05). Movement analysis distinguished between the three groups in the dynamic compression plate model, but a ceiling effect was demonstrated in the intramedullary nail and external fixator procedures, where intermediates and experts performed to comparable standards (p > 0.6). A total of 85% (18 of 21) of the subjects found the dynamic compression model and 57% (12 of 21) found all the models acceptable tools of assessment.

This study has validated a low-cost, high-fidelity porcine dynamic compression plate model using video rating scores for skills assessment and movement analysis. It has also demonstrated that Synbone models for the application of and intramedullary nail and an external fixator are less sensitive and should be improved for further assessment of surgical skills in trauma. The availability of valid objective tools of assessment of surgical skills allows further studies into improving methods of training.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 8 | Pages 1081 - 1084
1 Aug 2005
Han I Chang CB Lee S Lee MC Seong SC Kim TK

We sought to determine the degree of correlation between the condition of the patellar articular cartilage and patellofemoral symptoms and function in osteoarthritic patients undergoing total knee arthroplasty. The depth of the osteoarthritic lesion, as graded by the Outerbridge classification and its size and location were assessed to determine the condition of the patellar cartilage in 80 consecutive osteoarthritic knees undergoing total knee arthroplasty. The association between the condition of the cartilage and patellofemoral symptoms and function was investigated by correlation analysis.

The depth and size of the lesion had a significant but weak correlation with anterior knee pain (r = −0.300 and −0.289; p = 0.007 and 0.009, respectively), whereas location had no significant association (p > 0.05). None had a significant association with patellofemoral functional parameters (chair-rising, stair-climbing, and quadriceps power) (p > 0.05).

Our study indicates that patellofemoral symptoms and function are not completely determined by the condition of the cartilage. Caution should be taken when the symptoms and functional limitations are attributed to a lesion in the patellofemoral joint in making a decision regarding patellar resurfacing in total knee arthroplasty.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 1 | Pages 66 - 71
1 Jan 2007
Suh KT Lee SS Kim SJ Kim YK Lee JS

The scoliosis observed in chickens after pinealectomy resembles that seen in humans with an adolescent idiopathic scoliosis, suggesting that melatonin deficiency may be responsible. However, to date there have been no studies of pineal gland glucose metabolism in patients with adolescent idiopathic scoliosis that might support this hypothesis.

We examined the excretion of urinary 6-sulfatoxyl-melatonin as well as the glucose metabolism of the pineal gland in 14 patients with an adolescent idiopathic scoliosis and compared them with those of 13 gender-matched healthy controls using F-18 fluorodeoxyglucose brain positron emission tomography. There was no significant difference in the level of urinary 6-sulfatoxyl-melatonin or pineal gland metabolism between the study and the control group. We conclude that permanent melatonin deficiency is not a causative factor in the aetiology of adolescent idiopathic scoliosis.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 8 | Pages 1025 - 1031
1 Aug 2008
Mizu-uchi H Matsuda S Miura H Okazaki K Akasaki Y Iwamoto Y

We compared the alignment of 39 total knee replacements implanted using the conventional alignment guide system with 37 implanted using a CT-based navigation system, performed by a single surgeon. The knees were evaluated using full-length weight-bearing anteroposterior radiographs, lateral radiographs and CT scans.

The mean hip-knee-ankle angle, coronal femoral component angle and coronal tibial component angle were 181.8° (174.2° to 188.3°), 88.5° (84.0° to 91.8°) and 89.7° (86.3° to 95.1°), respectively for the conventional group and 180.8° (178.2° to 185.1°), 89.3° (85.8° to 92.0°) and 89.9° (88.0° to 93.0°), respectively for the navigated group.

The mean sagittal femoral component angle was 85.5° (80.6° to 92.8°) for the conventional group and 89.6° (85.5° to 94.0°) for the navigated group.

The mean rotational femoral and tibial component angles were −0.7° (−8.8° to 9.8°) and −3.3° (−16.8° to 5.8°) for the conventional group and −0.6° (−3.5° to 3.0°) and 0.3° (−5.3° to 7.7°) for the navigated group.

The ideal angles of all alignments in the navigated group were obtained at significantly higher rates than in the conventional group. Our results demonstrated significant improvements in component positioning with a CT-based navigation system, especially with respect to rotational alignment.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 1 | Pages 100 - 106
1 Jan 2007
Nunn TR Cheung WY Rollinson PD

Between September 2004 and December 2005 we carried out a prospective study of all cases of sepsis of the hip in childhood at a South African regional hospital with a large local population, and which also took referrals from nine rural hospitals. The clinical, radiological, ultrasound and bacteriological features were assessed. All the hips were drained by arthrotomy and the diagnosis was confirmed microbiologically and histologically. Hips with tuberculosis were excluded. The children were reviewed in a dedicated clinic at a mean follow-up of 8.1 months (3 to 18).

There were 40 hips with sepsis in 38 patients. Two patients were lost to follow-up. Nine (24%) had multi-focal sepsis. Overall, 13 hips (34%) had a full and uncomplicated clinical and radiological recovery and 25 (66%) had complications. All patients treated by arthrotomy and appropriate antibiotics within five days of the onset of symptoms had an uncomplicated recovery. Initial misdiagnosis was associated with a delay to arthrotomy. However, ‘deprivation’, consultation with a traditional healer, maternal educational attainment and distance to a primary health-care facility were not associated with delay to arthrotomy. The early correct diagnosis of this condition, common in the developing world, remains a significant factor in improving the clinical outcome.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 10 | Pages 1385 - 1390
1 Oct 2005
Niva MH Kiuru MJ Haataja R Pihlajamäki HK

The purpose of this study was to describe the anatomical distribution and incidence of fatigue injuries of the femur in physically-active young adults, based upon MRI studies. During a period of 70 months, 1857 patients with exercise-induced pain in the femur underwent MRI of the pelvis, hips, femora, and/or knees.

Of these, 170 patients had a total of 185 fatigue injuries, giving an incidence of 199 per 100 000 person-years. Bilateral injuries occurred in 9% of patients. The three most common sites affected were the femoral neck (50%), the condylar area (24%) and the proximal shaft (18%). A fatigue reaction was seen in 57%, and a fracture line in 22%. There was a statistical correlation between the severity of the fatigue injury and the duration of pain (p = 0.001). The location of the pain was normally at the site of the fatigue injury. Fatigue injuries of the femur appear to be relatively common in physically-active patients.