The purpose of this study was to evaluate the
long-term outcome of adults with spina bifida cystica (SBC) who
had been treated either operatively or non-operatively for scoliosis
during childhood. We reviewed 45 patients with a SBC scoliosis (Cobb angle ≥ 50º)
who had been treated at one of two children’s hospitals between
1991 and 2007. Of these, 34 (75.6%) had been treated operatively
and 11 (24.4%) non-operatively. After a mean follow-up of 14.1 years
(standard deviation ( Although patients in the two groups were demographically similar,
those who had undergone surgery had a larger mean Cobb angle (88.0º
( Spinal fusion in SBC scoliosis corrects coronal deformity and
stops progression of the curve but has no clear effect on HRQOL. Cite this article:
Large-head metal-on-metal (MoM) total hip replacements
(THR) have given rise to concern. Comparative studies of small-head
MoM THRs over a longer follow-up period are lacking. Our objective
was to compare the incidence of complications such as infection,
dislocation, revision, adverse local tissue reactions, mortality
and radiological and clinical outcomes in small-head (28 mm) MoM
and ceramic-on-polyethylene (CoP) THRs up to 12 years post-operatively. A prospective cohort study included 3341 THRs in 2714 patients.
The mean age was 69.1 years (range 24 to 98) and 1848 (55.3%) were
performed in women, with a mean follow-up of 115 months (18 to 201).
There were 883 MoM and 2458 CoP bearings. Crude incidence rates
(cases/1000 person-years) were: infection 1.3 In conclusion, we found similar results for small-head MoM and
CoP bearings up to ten years post-operatively, but after ten years
MoM THRs had a higher risk of all-cause revision. Furthermore, the
presence of an adverse response to metal debris seen in the small-head
MOM group at revision is a cause for concern. Cite this article:
Mobile-bearing unicompartmental knee replacements
(UKRs) with a flat tibial plateau have not performed well in the
lateral compartment, owing to a high dislocation rate. This led
to the development of the Domed Lateral Oxford UKR (Domed OUKR)
with a biconcave bearing. The aim of this study was to assess the
survival and clinical outcomes of the Domed OUKR in a large patient
cohort in the medium term. We prospectively evaluated 265 consecutive knees with isolated
disease of the lateral compartment and a mean age at surgery of
64 years (32 to 90). At a mean follow-up of four years ( The Domed Lateral OUKR gives good clinical outcomes, low re-operation
and revision rates and a low dislocation rate in patients with isolated
lateral compartmental disease, in the hands of the designer surgeons. Cite this article:
To review the systemic impact of smoking on bone healing as evidenced
within the orthopaedic literature. A protocol was established and studies were sourced from five
electronic databases. Screening, data abstraction and quality assessment
was conducted by two review authors. Prospective and retrospective
clinical studies were included. The primary outcome measures were
based on clinical and/or radiological indicators of bone healing.
This review specifically focused on non-spinal orthopaedic studies.Objectives
Methods
The aim of this study was to establish a classification system for the acromioclavicular joint using cadaveric dissection and radiological analyses of both reformatted computed tomographic scans and conventional radiographs centred on the joint. This classification should be useful for planning arthroscopic procedures or introducing a needle and in prospective studies of biomechanical stresses across the joint which may be associated with the development of joint pathology. We have demonstrated three main three-dimensional morphological groups namely flat, oblique and curved, on both cadaveric examination and radiological assessment. These groups were recognised in both the coronal and axial planes and were independent of age.
The April 2013 Hip &
Pelvis Roundup360 looks at: hip cartilage and magnets; labral repair or resection; who benefits from injection; rotational osteotomy for osteonecrosis; whether ceramic implants risk fracture; dual articulation; and hydroxyapatite.
We reviewed 91 patients (103 feet) who underwent
a Ludloff osteotomy combined with additional procedures. According
to the combined procedures performed, patients were divided into
Group I (31 feet; first web space release), Group II (35 feet; Akin
osteotomy and trans-articular release), or Group III (37 feet; Akin
osteotomy, supplementary axial Kirschner (K-) wire fixation, and
trans-articular release). Each group was then further subdivided
into severe and moderate deformities. The mean hallux valgus angle correction of Group II was significantly
greater than that of Group I (p = 0.001). The mean intermetatarsal
angle correction of Group III was significantly greater than that
of Group II (p <
0.001). In severe deformities, post-operative
incongruity of the first metatarsophalangeal joint was least common
in Group I (p = 0.026). Akin osteotomy significantly increased correction
of the hallux valgus angle, while a supplementary K-wire significantly
reduced the later loss of intermetatarsal angle correction. First
web space release can be recommended for severe deformity. Additionally,
K-wire fixation (odds ratio (OR) 5.05 (95% confidence interval (CI) 1.21
to 24.39); p = 0.032) and the pre-operative hallux valgus angle
(OR 2.20 (95% CI 1.11 to 4.73); p = 0.001) were shown to be factors
affecting recurrence of hallux valgus after Ludloff osteotomy. Cite this article:
A total of 219 hips in 192 patients aged between
18 and 65 years were randomised to 28-mm metal-on-metal uncemented
total hip replacements (THRs, 107 hips) or hybrid hip resurfacing
(HR, 112 hips). At a mean follow-up of eight years (6.6 to 9.3)
there was no significant difference between the THR and HR groups
regarding rate of revision (4.0% (4 of 99) Cite this article:
Between 1990 and 2000, 123 hips in 110 patients were reconstructed for aseptic loosening using impaction bone grafting with frozen, irradiated, morsellised femoral heads and cemented acetabular components. This series was reported previously at a mean follow-up of five years. We have extended this follow-up and now describe the outcome of 86 hips in 74 patients at a mean of ten years. There have been 19 revisions, comprising nine for infection, seven for aseptic loosening and three for dislocation. In surviving acetabular reconstructions, union of the graft had occurred in 64 of 67 hips (95.5%). Survival analysis for all indications at ten years was 83.3% (95% confidence interval (CI) 68 to 89) and 71.3% (95% CI 58 to 84) at 15 years. Acetabular reconstruction using irradiated allograft and a cemented acetabular component is an effective method of reconstruction, providing results in the medium- to long-term comparable with those of reported series where non-irradiated freshly-frozen bone was used.
Antibiotic impregnated articulating spacers are
used in two-stage revision total knee arthroplasty to deliver local antibiotic
therapy while preserving function. We have observed infection control
in greater than 95% of cases with functional outcomes approaching
those seen in revision for aseptic loosening. Higher failure has
been observed with methicillin resistant organisms.
There have been few reports in the literature of total elbow arthroplasty extending beyond 10 to 15 years. We reviewed 40 patients (41 elbows) with a mean age of 56 years (19 to 83) who had undergone a Coonrad/Coonrad-Morrey elbow arthroplasty by one surgeon for various diagnoses between 1974 and 1994. Surgical selection excluded patients with previous elbow infection or who refused to accept a sedentary level of elbow activity postoperatively. Objective data were collected from charts, radiographs, clinical photographs and supplemented by the referring orthopaedic surgeons’ records and radiographs if health or distance prevented a patient from returning for final review. Subjective outcome was defined by patient satisfaction. Of the 41 elbows, 21 were functional between 10 and 14 years after operation, ten between 15 and 19 years and ten between 20 and 31 years. There were 14 complications and 13 revisions, but no cases of acute infection, or permanent removal of any implant.
Noise generation has been reported with ceramic-on-ceramic
articulations in total hip replacement (THR). This study evaluated
208 consecutive Delta Motion THRs at a mean follow-up of 21 months
(12 to 35). There were 141 women and 67 men with a mean age of 59
years (22 to 84). Patients were reviewed clinically and radiologically,
and the incidence of noise was determined using a newly described
assessment method. Noise production was examined against range of
movement, ligamentous laxity, patient-reported outcome scores, activity
level and orientation of the acetabular component. There were 143
silent hips (69%), 22 (11%) with noises other than squeaking, 17
(8%) with unreproducible squeaking and 26 (13%) with reproducible
squeaking. Hips with reproducible squeaking had a greater mean range
of movement (p <
0.001) and mean ligament laxity (p = 0.004), smaller
median head size (p = 0.01) and decreased mean acetabular component
inclination (p = 0.02) and anteversion angle (p = 0.02) compared
with the other groups. There was no relationship between squeaking
and age (p = 0.13), height (p = 0.263), weight (p = 0.333), body
mass index (p = 0.643), gender (p = 0.07) or patient outcome score
(p = 0.422). There were no revisions during follow-up. Despite the
surprisingly high incidence of squeaking, all patients remain satisfied
with their hip replacement. Cite this article:
The purpose of this study was to evaluate the
clinical results of a newly designed prosthesis to replace the body
of the talus in patients with aseptic necrosis. Between 1999 and
2006, 22 tali in 22 patients were replaced with a ceramic prosthesis.
A total of eight patients were treated with the first-generation
prosthesis, incorporating a peg to fix into the retained neck and
head of the talus, and the remaining 14 were treated with the second-generation prosthesis,
which does not have the peg. The clinical results were assessed
by the American Orthopaedic Foot and Ankle Society ankle/hindfoot
scale. The mean follow-up was 98 months (18 to 174). The clinical results
of the first-generation prostheses were excellent in three patients,
good in one, fair in three and poor in one. There were, however,
radiological signs of loosening, prompting a change in design. The
clinical results of the second-generation prostheses were excellent
in three patients, good in five, fair in four and poor in two, with
more favourable radiological appearances. Revision was required
using a total talar implant in four patients, two in each group. Although the second-generation prosthesis produced better results,
we cannot recommend the use of a talar body prosthesis. We now recommend
the use of a total talar implant in these patients.
In 2004 we described the ten-year prospective results of 38 total hip replacements using the Furlong hydroxyapatite-ceramic-coated femoral component in 35 patients <
50 years old. We have now reviewed the surviving 35 arthroplasties in 33 patients at a mean of 16 years (10.3 to 19.9). The mean age of the surviving patients at the time of operation was 41.3 years (26.0 to 49.0). Of these, eight have undergone revision of their acetabular component for aseptic loosening. None of the femoral components has had revision for aseptic loosening giving a survival rate of 100% at 16 years (95% confidence interval 89% to 100%). The Furlong hydroxyapatite-ceramic-coated femoral component gives excellent long-term survival in young and active patients.
Eighteen hip fusions were converted to total
hip replacements. A constrained acetabular liner was used in three hips.
Mean follow up was five years (two to 15). Two (11%) hips failed,
requiring revision surgery and two patients (11%) had injury to
the peroneal nerve. Heterotopic ossification developed in seven
(39%) hips, in one case resulting in joint ankylosis. No hips dislocated. Conversion of hip fusion to hip replacement carries an increased
risk of heterotopic ossification and neurological injury. We advise
prophylaxis against heterotropic ossification. When there is concern
about hip stability we suggest that the use of a constrained acetabular
liner is considered. Despite the potential for complications, this procedure
had a high success rate and was effective in restoring hip function.
Fractures of the femoral neck in children are
rare, high-energy injuries with high complication rates. Their treatment has
become more interventional but evidence of the efficacy of such
measures is limited. We performed a systematic review of studies
examining different types of treatment and their outcomes, including
avascular necrosis (AVN), nonunion, coxa vara, premature physeal
closure (PPC), and Ratliff’s clinical criteria. A total of 30 studies
were included, comprising 935 patients. Operative treatment and
open reduction were associated with higher rates of AVN. Delbet
types I and II fractures were most likely to undergo open reduction
and internal fixation. Coxa vara was reduced in the operative group,
whereas nonunion and PPC were not related to surgical intervention. Nonunion
and coxa vara were unaffected by the method of reduction. Capsular
decompression had no effect on AVN. Although surgery allows a more
anatomical union, it is uncertain whether operative treatment or
the type of reduction affects the rate of AVN, nonunion or PPC,
because more severe fractures were operated upon more frequently.
A delay in treatment beyond 24 hours was associated with a higher
incidence of AVN. Cite this article:
We describe the survivorship of the Medial Rotation total knee replacement (TKR) at ten years in 228 cemented primary replacements implanted between October 1994 and October 2006, with their clinical and radiological outcome. This implant has a highly congruent medial compartment, with the femoral component represented by a portion of a sphere which articulates with a matched concave surface on the medial side of the tibial insert. There were 78 men (17 bilateral TKRs) and 111 women (22 bilateral TKRs) with a mean age of 67.9 years (28 to 90). All the patients were assessed clinically and radiologically using the American Knee Society scoring systems. The mean follow-up was for six years (1 to 13) with only two patients lost to follow-up and 34 dying during the period of study, one of whom had required revision for infection. There were 11 revisions performed in total, three for aseptic loosening, six for infection, one for a periprosthetic fracture and one for a painful but well-fixed replacement performed at another centre. With revision for any cause as the endpoint, the survival at ten years was 94.5% (95% CI 85.1 to 100), and with aseptic loosening as the endpoint 98.4% (95% CI 93 to 100). The mean American Knee Society score improved from 47.6 (0 to 88) to 72.2 (26 to 100) and for function from 45.1 (0 to 100) to 93.1 (45 to 100). Radiological review failed to detect migration in any of the surviving knees. The clinical and radiological results of the Medial Rotation TKR are satisfactory at ten years. The increased congruence of the medial compartment has not led to an increased rate of loosening and continued use can be supported.
This was a retrospective analysis of the medium-
to long-term results of 46 TC3 Sigma revision total knee replacements
using long uncemented stems in press-fit mode. Clinical and radiological analysis took place pre-operatively,
at two years post-operatively, and at a mean follow-up of 8.5 years
(4 to 12). The mean pre-operative International Knee Society (IKS)
clinical score was 42 points (0 to 74), improving to 83.7 (52 to
100) by the final follow-up. The mean IKS score for function improved
from 34.3 points (0 to 80) to 64.2 (15 to 100) at the final follow-up.
At the final follow-up 30 knees (65.2%) had an excellent result, seven
(15.2%) a good result, one (2.2%) a medium and eight (17.4%) a poor
result. There were two failures, one with anteroposterior instability
and one with aseptic loosening. The TC3 revision knee system, when used with press-fit for long
intramedullary stems and cemented femoral and tibial components,
in both septic and aseptic revisions, results in a satisfactory
clinical and radiological outcome, and has a good medium- to long-term
survival rate.
Medium-term survivorship of the Oxford phase
3 unicompartmental knee replacement (UKR) has not yet been established
in an Asian population. We prospectively evaluated the outcome of
400 phase 3 Oxford UKRs in 320 Korean patients with a mean age at
the time of operation of 69 years (48 to 82). The mean follow-up
was 5.2 years (1 to 10). Clinical and radiological assessment was
carried out pre- and post-operatively. At five years, the mean Knee
Society knee and functional scores had increased significantly from
56.2 (30 to 91) pre-operatively to 87.2 (59 to 98) (p = 0.034) and
from 59.2 (30 to 93) to 88.3 (50 to 100) (p = 0.021), respectively.
The Oxford knee score increased from a mean of 25.8 (12 to 39) pre-operatively
to 39.8 (25 to 58) at five years (p = 0.038). The ten-year survival
rate was 94% (95% confidence interval 90.1 to 98.0). A total of
14 UKRs (3.5%) required revision. The most common reason for revision
was dislocation of the bearing in 12 (3%). Conversion to a total
knee replacement was required in two patients who developed osteoarthritis
of the lateral compartment. This is the largest published series of UKR in Korean patients.
It shows that the mid-term results after a minimally invasive Oxford
phase 3 UKR can yield satisfactory clinical and functional results
in this group of patients.
We investigated 60 patients (89 feet) with a
mean age of 64 years (61 to 67) treated for congenital clubfoot deformity,
using standardised weight-bearing radiographs of both feet and ankles
together with a functional evaluation. Talocalcaneal and talonavicular
relationships were measured and the degree of osteo-arthritic change
in the ankle and talonavicular joints was assessed. The functional
results were evaluated using a modified Laaveg-Ponseti score. The
talocalcaneal (TC) angles in the clubfeet were significantly lower
in both anteroposterior (AP) and lateral projections than in the
unaffected feet (p <
0.001 for both views). There was significant
medial subluxation of the navicular in the clubfeet compared with
the unaffected feet (p <
0.001). Severe osteoarthritis in the
ankle joint was seen in seven feet (8%) and in the talonavicular
joint in 11 feet (12%). The functional result was excellent or good
(≥ 80 points) in 29 patients (48%), and fair or poor (<
80 points)
in 31 patients (52%). Patients who had undergone few (0 to 1) surgical
procedures had better functional outcomes than those who had undergone
two or more procedures (p <
0.001). There was a significant correlation
between the functional result and the degree of medial subluxation
of the navicular (p <
0.001, r2 = 0.164), the talocalcaneal
angle on AP projection (p <
0.02, r2 = 0.025) and extent of osteoarthritis
in the ankle joint (p <
0.001). We conclude that poor functional outcome in patients with congenital
clubfoot occurs more frequently in those with medial displacement
of the navicular, osteoarthritis of the talonavicular and ankle
joints, and a low talocalcaneal angle on the AP projection, and
in patients who have undergone two or more surgical procedures. However,
the ankle joint in these patients appeared relatively resistant
to the development of osteoarthritis.