Advertisement for orthosearch.org.uk
Results 141 - 160 of 503
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 4 | Pages 604 - 607
1 Aug 1987
Beltran J

Resection arthroplasty of the patella has been found to be a satisfactory procedure for the treatment of patellofemoral pain caused by osteoarthritis. In the present series 60% of the operated cases were pain-free on a 31-month average follow-up. The patients found it easier to climb stairs and to kneel and in most cases the radiographic joint space was good


Bone & Joint 360
Vol. 10, Issue 3 | Pages 13 - 16
1 Jun 2021


The Journal of Bone & Joint Surgery British Volume
Vol. 62-B, Issue 4 | Pages 511 - 514
1 Nov 1980
Afoke N Byers P Hutton W

A casting method for measuring the intra-articular space in the loaded hip is described. The results of tests on 22 hips from 22 cadavers show that the joint space is variable both in location and size and can disappear under light loads. It seems likely that the size and shape of the space influence how much access synovial fluid has for lubrication and nutrition


The Journal of Bone & Joint Surgery British Volume
Vol. 48-B, Issue 2 | Pages 289 - 298
1 May 1966
Bulmer JH

1. Septic arthritis of the hip in adults is not common and the diagnosis can be difficult. The value of diagnostic aspiration is emphasised. 2. Predisposing causes in fifty patients are analysed and the possible relationship to pelvic infection is discussed. 3. Loss of joint space is occasionally seen within one week of the onset of the infection. 4. A method of treatment is suggested and the value of decompression by arthrotomy is discussed


Bone & Joint Open
Vol. 2, Issue 6 | Pages 397 - 404
1 Jun 2021
Begum FA Kayani B Magan AA Chang JS Haddad FS

Limb alignment in total knee arthroplasty (TKA) influences periarticular soft-tissue tension, biomechanics through knee flexion, and implant survival. Despite this, there is no uniform consensus on the optimal alignment technique for TKA. Neutral mechanical alignment facilitates knee flexion and symmetrical component wear but forces the limb into an unnatural position that alters native knee kinematics through the arc of knee flexion. Kinematic alignment aims to restore native limb alignment, but the safe ranges with this technique remain uncertain and the effects of this alignment technique on component survivorship remain unknown. Anatomical alignment aims to restore predisease limb alignment and knee geometry, but existing studies using this technique are based on cadaveric specimens or clinical trials with limited follow-up times. Functional alignment aims to restore the native plane and obliquity of the joint by manipulating implant positioning while limiting soft tissue releases, but the results of high-quality studies with long-term outcomes are still awaited. The drawbacks of existing studies on alignment include the use of surgical techniques with limited accuracy and reproducibility of achieving the planned alignment, poor correlation of intraoperative data to long-term functional outcomes and implant survivorship, and a paucity of studies on the safe ranges of limb alignment. Further studies on alignment in TKA should use surgical adjuncts (e.g. robotic technology) to help execute the planned alignment with improved accuracy, include intraoperative assessments of knee biomechanics and periarticular soft-tissue tension, and correlate alignment to long-term functional outcomes and survivorship.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 9 | Pages 1178 - 1182
1 Sep 2009
Hakki S Coleman S Saleh K Bilotta VJ Hakki A

The requirement for release of collateral ligaments to achieve a stable, balanced total knee replacement has been reported to arise in about 50% to 100% of procedures. This wide range reflects a lack of standardised quantitative indicators to determine the necessity for a release. Using recent advances in computerised navigation, we describe two navigational predictors which provide quantitative measures that can be used to identify the need for release. The first was the ability to restore the mechanical axis before any bone resection was performed and the second was the discrepancy in the measured medial and lateral joint spaces after the tibial osteotomy, but before any femoral resection. These predictors showed a significant association with the need for collateral ligament release (p < 0.001). The first predictor using the knee stress test in extension showed a sensitivity of 100% and a specificity of 98% and the second, the difference between medial and lateral gaps in millimetres, a sensitivity of 83% and a specificity of 95%. The use of the two navigational predictors meant that only ten of the 93 patients required collateral ligament release to achieve a stable, neutral knee


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 2 | Pages 188 - 191
1 Mar 2000
Journeaux SF Morgan DAF Donnelly WJ

We have reviewed 202 consecutive primary hip replacements using a Freeman cemented femoral component after a mean period of follow-up of 64 months (23 to 113). There was only one revision for aseptic loosening. Retention of the femoral neck may act to reduce the torsional and shear forces at the implant-cement interface and may provide a seal against the migration of polyethylene-laden joint fluid in the potential joint space. The cemented Freeman femoral component with retention of the femoral neck was successful for up to nine years


The Bone & Joint Journal
Vol. 103-B, Issue 6 Supple A | Pages 59 - 66
1 Jun 2021
Abhari S Hsing TM Malkani MM Smith AF Smith LS Mont MA Malkani AL

Aims

Alternative alignment concepts, including kinematic and restricted kinematic, have been introduced to help improve clinical outcomes following total knee arthroplasty (TKA). The purpose of this study was to evaluate the clinical results, along with patient satisfaction, following TKA using the concept of restricted kinematic alignment.

Methods

A total of 121 consecutive TKAs performed between 11 February 2018 to 11 June 2019 with preoperative varus deformity were reviewed at minimum one-year follow-up. Three knees were excluded due to severe preoperative varus deformity greater than 15°, and a further three due to requiring revision surgery, leaving 109 patients and 115 knees to undergo primary TKA using the concept of restricted kinematic alignment with advanced technology. Patients were stratified into three groups based on the preoperative limb varus deformity: Group A with 1° to 5° varus (43 knees); Group B between 6° and 10° varus (56 knees); and Group C with varus greater than 10° (16 knees). This study group was compared with a matched cohort of 115 TKAs and 115 patients using a neutral mechanical alignment target with manual instruments performed from 24 October 2016 to 14 January 2019.


The Bone & Joint Journal
Vol. 103-B, Issue 2 | Pages 353 - 359
1 Feb 2021
Cho C Min B Bae K Lee K Kim DH

Aims

Ultrasound (US)-guided injections are widely used in patients with conditions of the shoulder in order to improve their accuracy. However, the clinical efficacy of US-guided injections compared with blind injections remains controversial. The aim of this study was to compare the accuracy and efficacy of US-guided compared with blind corticosteroid injections into the glenohumeral joint in patients with primary frozen shoulder (FS).

Methods

Intra-articular corticosteroid injections were administered to 90 patients primary FS, who were randomly assigned to either an US-guided (n = 45) or a blind technique (n = 45), by a shoulder specialist. Immediately after injection, fluoroscopic images were obtained to assess the accuracy of the injection. The outcome was assessed using a visual analogue scale (VAS) for pain, the American Shoulder and Elbow Surgeons (ASES) score, the subjective shoulder value (SSV) and range of movement (ROM) for all patients at the time of presentation and at three, six, and 12 weeks after injection.


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 3 | Pages 437 - 440
1 May 1998
Douw CM Bulstra SK Vandenbroucke J Geesink RGT Vermeulen A

We describe six knees in five patients, referred to us after accidental irrigation with chlorhexidine 1% in aqueous solution during arthroscopy. All six knees developed persisting pain, swelling and crepitus with loss of range of movement. Radiographs showed loss of joint space in all three compartments due to extensive chondrolysis, with many loose bodies and synovitis. Histological examination showed partial necrosis of the cartilage, with slight non-specific inflammation and fibrosis of synovial specimens. Care is needed in checking irrigation fluids, and these should have a distinctive colour


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 5 | Pages 720 - 725
1 Sep 1995
van Valburg A van Roermund P Lammens J van Melkebeek J Verbout A Lafeber E Bijlsma J

We applied joint distraction using an Ilizarov apparatus in 11 patients with post-traumatic osteoarthritis of the ankle to try to delay the need for an arthrodesis. Distraction for three months resulted in clinical improvement in pain and mobility for a mean of two years, with an increase in the joint space. We considered that these effects may be produced by the absence of mechanical stress on the cartilage combined with the intra-articular hydrostatic pressures during distraction. We measured these pressures during walking with distraction, and found levels very similar to those reported to improve osteoarthritic cartilage when applied in vitro


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 1 | Pages 73 - 75
1 Jan 1991
Harper W Barnes M Gregg P

We studied 50 patients with fractures of the femoral neck, 33 intracapsular and 17 extracapsular. Intraosseous pressure was measured by a transducer within the bone to quantify blood flow, and intracapsular pressure by a needle introduced into the joint space. The mean intracapsular pressure was lower in the extracapsular fractures. In these, the mean intraosseous pressure in the femoral head was unchanged by aspiration of the joint. However in the intracapsular fractures aspiration produced a significant decrease in intra-osseous pressure and an increase in pulse pressure within the femoral head. The results suggest that aspiration of intracapsular haematoma produced an increase in femoral head blood flow by relieving tamponade


Bone & Joint Research
Vol. 10, Issue 2 | Pages 137 - 148
1 Feb 2021
Lawrence EA Aggleton J van Loon J Godivier J Harniman R Pei J Nowlan N Hammond C

Aims

Vertebrates have adapted to life on Earth and its constant gravitational field, which exerts load on the body and influences the structure and function of tissues. While the effects of microgravity on muscle and bone homeostasis are well described, with sarcopenia and osteoporosis observed in astronauts returning from space, the effects of shorter exposures to increased gravitational fields are less well characterized. We aimed to test how hypergravity affects early cartilage and skeletal development in a zebrafish model.

Methods

We exposed zebrafish to 3 g and 6 g hypergravity from three to five days post-fertilization, when key events in jaw cartilage morphogenesis occur. Following this exposure, we performed immunostaining along with a range of histological stains and transmission electron microscopy (TEM) to examine cartilage morphology and structure, atomic force microscopy (AFM) and nanoindentation experiments to investigate the cartilage material properties, and finite element modelling to map the pattern of strain and stress in the skeletal rudiments.


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 4 | Pages 635 - 639
1 Jul 1991
Futami T Kasahara Y Suzuki S Ushikubo S Tsuchiya T

We used ultrasonography to examine 36 children suffering from transient synovitis and 12 children with early Perthes' disease. Widening of the joint space was revealed by ultrasonography in all affected hips with either disease. In the patients with transient synovitis, capsular distension was attributed to synovial effusion, while in the patients with Perthes' disease it was produced by thickening of the synovial membrane. Neither capsular distension nor thickening of the joint cartilage was seen in the contralateral normal hip in the patients with transient synovitis, but they were common in early Perthes' disease. Ultrasonography may provide significant diagnostic clues to differentiate early Perthes' from transient synovitis


The Journal of Bone & Joint Surgery British Volume
Vol. 68-B, Issue 5 | Pages 808 - 811
1 Nov 1986
Kallio P Ryoppy S Kunnamo I

A prospective study was made of 119 children with transient synovitis or any other cause for synovial effusion and elevated intra-articular pressure. During a follow-up of one year not one case of Perthes' disease was diagnosed and the late clinical and radiographic changes were minimal with moderate overgrowth of the femoral head in 33% and widening of the joint space in 14.2%. Our results do not support the widely accepted concept that Perthes' disease develops as a result of the period of elevated intra-articular pressure found in transient synovitis. Further research into this and Perthes' disease should follow the premise that they are two different diseases without any aetiological connection


The Journal of Bone & Joint Surgery British Volume
Vol. 67-B, Issue 5 | Pages 747 - 749
1 Nov 1985
Seth M Khurana J

Ten patients with 13 ankylosed elbows after burns are described. Six elbows, fixed in nearly full extension, had almost total functional disability; the other seven had varying amounts of deformity. In five of the 13 elbows there was a continuous bony mass with loss of the joint space; these were treated by a modified excision arthroplasty which restored good movement and useful function, though there was some lateral laxity. Six elbows had a posterior bony block; this was excised, which restored a useful arc of movement. The literature on bony ankylosis after burns is reviewed and the management of these cases in a developing country is described


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 3 | Pages 432 - 436
1 May 1998
Terauchi M Shirakura K Katayama M Higuchi H Takagishi K

We studied 37 patients with varus osteoarthritis of the knee to determine the influence of the bone mineral density (BMD) on the varus deformity. There were 15 men (21 knees) and 22 women (38 knees). The mean age of the men was 69 years and of the women 68 years. BMD was measured in the L1–L4 spinal region using dual X-ray absorptiometry. In the women a low level of BMD was associated with varus deformity originating at the proximal tibia, but a high level was predominantly linked with deformity originating in the joint space. Similar findings were obtained in the men. Our results suggest that a low BMD predisposes to trabecular microfractures and consequently increased stress on the articular cartilage. A low BMD does not preclude osteoarthritic change in the knee


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 1 | Pages 66 - 69
1 Jan 2002
Kloen P Leunig M Ganz R

Osteonecrosis of the femoral head can be caused by a variety of disorders and affects the relatively young patient. Most studies have concentrated on the femoral changes; the sites of early lesions of the labrum and acetabular cartilage have not been recorded. We studied 17 hips with osteonecrosis and a wide congruent joint space on radiographs and by direct inspection of the femoral head, labrum and acetabular cartilage during surgery. All of the femoral heads had some anterosuperior flattening which reduced the head-neck ratio in this area. A consistent pattern of damage to the labrum and the acetabular cartilage was seen in all hips. Intraoperatively, impingement and the cam-effect with its spatial correlation with lesions of the labrum and acetabular cartilage were observed. These findings could be helpful when undertaking conservative surgery for osteonecrosis, since the recognition of early radiologically undetectable acetabular lesions may require modification of the surgical technique


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 2 | Pages 313 - 318
1 Mar 1995
Lee A Campbell J Hoffman E

We reviewed 33 children with tuberculosis of the knee treated during the period from 1979 to 1991. All were treated with triple chemotherapy, using rifampicin, isoniazid and pyrazinamide for nine months. No patient had a synovectomy; surgery was limited to open biopsy or salvage procedures such as posterior release and arthrodesis for late stages of the disease. The radiological appearance of the knee at presentation predicted the outcome. The 30 patients with stage-1 (normal) or stage-2 (osteomyelitic) disease had excellent or good results; the three with narrowed joint spaces in stage 3 or stage 4 (arthritic) had fair or poor results. Early active mobilisation, as against long-term immobilisation, seemed to have no effect on the outcome of stage-1 or stage-2 disease


The Bone & Joint Journal
Vol. 102-B, Issue 7 | Pages 822 - 831
1 Jul 2020
Kuroda Y Saito M Çınar EN Norrish A Khanduja V

Aims

This paper aims to review the evidence for patient-related factors associated with less favourable outcomes following hip arthroscopy.

Methods

Literature reporting on preoperative patient-related risk factors and outcomes following hip arthroscopy were systematically identified from a computer-assisted literature search of Pubmed (Medline), Embase, and Cochrane Library using Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA) guidelines and a scoping review.