Advertisement for orthosearch.org.uk
Results 1561 - 1580 of 3117
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 3 | Pages 485 - 487
1 May 1994
Lennox I Cobb A Knowles J Bentley G

We describe 83 knees (69 patients) which had had patellectomy for anterior knee pain (52), patellofemoral osteoarthritis (25) or comminuted fractures (6) between 1942 and 1978. The patients were questioned about their symptoms and the function of the operated knee 14 to 50 years after operation. In the group with anterior knee pain, 76% achieved good results and were satisfied with the operation. Only 54% of the osteoarthritis group had satisfactory relief of pain and most had progressive deterioration of function. Sixteen patients who had had unilateral patellectomy were assessed by dynamometry, ultrasound and radiography. The average quadriceps muscle power was 60% of that on the normal side although two patients had stronger muscles in their operated than in their unoperated legs


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 5 | Pages 772 - 776
1 Nov 1988
Kannus P Jarvinen M

We have reviewed 32 patients who sustained a substantial knee ligament injury during adolescence when their knee epiphyses were open. They were all treated non-operatively and re-examined and evaluated in detail after an average of eight years. There were 25 Grade II partial tears and seven Grade III complete tears. After Grade II injuries the functional results were excellent or good, though static instability had not improved from the initial post-traumatic examination. The long-term results of Grade III injuries were poor, because of chronic functional instability, with continuous symptoms and some post-traumatic osteoarthritis. The results of non-operative treatment for Grade III ligament injuries were not acceptable


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 4 | Pages 652 - 657
1 Jul 1996
Abudu A Carter SR Grimer RJ

Improvement in the life expectancy of patients with primary bone tumours has led to increased emphasis on limb salvage and preservation of function. Between 1979 and 1994 we used custom-made endoprostheses in 18 patients to reconstruct diaphyseal defects after excision of primary bone tumours. The mean age at operation was 26 years (9 to 64) and the median follow-up 65 months (6 to 188). Fifteen patients have survived and are free from local or metastatic disease. Local recurrence developed in one patient. Using the modified Enneking functional scoring system, 77% of the patients achieved 80% or more of their premorbid functional capability. Mechanical loosening, limb shortening and secondary osteoarthritis were the main complications. There were no infections. We conclude that diaphyseal endoprostheses offer a good clinical and functional outcome in the lower limb


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 1 | Pages 130 - 134
1 Jan 1988
Gerber C Terrier F Ganz R

In the Trillat procedure for recurrent anterior instability of the shoulder the coracoid process is osteotomised and tilted downward to act as a bone block, and a screw is used to fix it and the Bankart lesion to the anterior scapular neck. We reviewed 52 cases after a mean follow-up of 69 months. Results in 73% of shoulders were excellent, 10% were good, 7% fair and 10% poor. Dislocation recurred in 4%, but a positive apprehension sign was present in 10 other shoulders. Some degenerative changes were seen in 62% of shoulders, a complication known to be associated with bone-block procedures. The most important reason for loss of lateral rotation was iatrogenic impingement of the coracoid. This frequent and potentially serious complication can also cause posterior subluxation of the humeral head and osteoarthritis


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 1 | Pages 60 - 66
1 Jan 1999
Schramm M Pitto RP Rohm E Hohmann D

We have examined the effect of the Wagner spherical acetabular osteotomy on preserving the joint in 38 hips with a mean follow-up of 17 years. At the time of the initial operation, 55% of patients had clinical symptoms and 30 joints showed minimal or absent radiological signs of osteoarthritis. At follow-up, 54% of patients had a good functional result. The osteotomy improved the mean centre-edge angle from −3° to +15°, the mean anterior centre-edge angle to 23° and the acetabular head index to 75%. The obliquity of the acetabular roof decreased from 28° to 16°. One patient improved, but 14 deteriorated with joint degeneration. Of these, one progressed because of postoperative deep-tissue infection and five due to undercorrection. One patient needed total joint replacement after 14 years. At 17 years after operation, Wagner osteotomy had prevented progression of secondary arthritis in 63% of cases


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 1 | Pages 171 - 177
1 Jan 1999
Okamoto T Atsuta Y Shimazaki S

We studied the sensory afferent properties of normal, immobilised and inflamed rat knees by recording the activity of the medial articular nerve (MAN). When the knee was inflamed by kaolin-carrageenan or immobilised for six weeks, MAN activity significantly increased during rest and continuous passive motion (CPM). The maximal discharge rate tended to increase depending on the angular velocity of the CPM. When the knees were then rested for one hour before again starting CPM, activity was further increased at the initial CPM cycle, the ‘post-rest effect’. Analysis of the conduction velocity showed that 94% and 66% of spike units on the recorded discharge of the immobilised and inflamed knees, respectively, belonged to fine nerve fibres. Our findings show that the sensory receptors in the knee are sensitised in a similar manner by immobilisation and by inflammation, suggesting a relationship to pain. The post-rest effect may be related to a characteristic symptom of osteoarthritis called ‘starting pain’


The Journal of Bone & Joint Surgery British Volume
Vol. 53-B, Issue 2 | Pages 324 - 337
1 May 1971
Bentley G

1. Degenerative arthritis has been produced consistently in adult rabbits by the injection of the proteolytic plant enzyme papain into the hip joint. Arthritic changes were recognisable radiographically after six weeks. 2. A progression of changes occurred, from loss of acid mucopolysaccharide staining in the matrix, fibrillation, fissuring and erosion of articular cartilage with death of chondrocytes in the weight-bearing areas, to secondary bony changes of subchondral sclerosis, occasional cysts and osteophyte formation. 3. Synovial inflammation occurred with accumulation of cartilage and bone debris in the inferior capsule and later capsular thickening. 4. It is suggested that this arthritis is sufficiently similar to human osteoarthritis to be useful as a model for further studies of the pathogenesis of the disease and the effects of different methods of treatment


The Journal of Bone & Joint Surgery British Volume
Vol. 51-B, Issue 3 | Pages 488 - 493
1 Aug 1969
Fitzgerald JAW

1. One hundred cases of arthrodesis of first metatarso-phalangeal joint have been reviewed after a post-operative interval of at least ten years. 2. Seventy-seven per cent of patients were completely satisfied with the late results ; only 9 per cent were dissatisfied. 3. The two major factors leading to poor results were found to be malposition of the arthrodesis, and interphalangeal osteoarthritis. 4. The ideal position for fusion is considered to be in at least 20 degrees of valgus, preferably between 20 and 30 degrees ; between 20 and 40 degrees of dorsiflexion ; and most importantly, neutral rotation. 5. The precise operative technique is not important provided it maintains the position obtained at operation until the arthrodesis is sound


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 7 | Pages 1034 - 1036
1 Sep 2001
Rees JL Price AJ Lynskey TG Svärd UCG Dodd CAF Murray DW

Satisfactory selection criteria are essential for the successful outcome of unicompartmental knee arthroplasty (UCA). We report the frequency of revision of the Oxford medial unicompartmental arthroplasty in knees previously treated for anteromedial osteoarthritis by high tibial osteotomy (HTO). The combined results from three sources were used to allow statistical analysis of this uncommon subgroup. In the combined series of 631 knees (507 patients) which had medial unicompartmental replacement, 613 were primary procedures and 18 were for a failed HTO. The mean follow-up times of the two groups were similar (5.8 years and 5.4 years, respectively). At review, 19 (3.1%) of the primary procedures and five (27.8%) of those undertaken for a failed HTO had been revised to total knee replacement. Survival analysis revealed the ten-year cumulative survivals to be 96% and 66%, respectively. The log-rank comparison of these survivals revealed a highly significant difference (p < 0.0001). We recommend that the Oxford UCA should not be used in knees which have previously undergone an HTO


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 5 | Pages 752 - 756
1 Sep 1992
Sward L Hughes J Howell C Colton C

We have reviewed the results of 19 ankle arthrodeses in 18 patients by a new technique of posterior internal compression. Sixteen of the ankles fused at a mean time of 14 weeks and the other three after reoperation. Complications included one case each of infection, Sudeck's atrophy and non-fatal pulmonary embolism. Clinical assessment using Mazur's ankle score showed excellent or good results in nine ankles and three painfree ankles in patients who were wheelchair-bound for other reasons. The mean position of fusion was in 1.7 degrees equinus and 0.8 degrees varus, and the mean range of midtarsal movements was 15.8 degrees. Twelve patients showed radiographic signs of talonavicular or subtalar osteoarthritis


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 5 | Pages 726 - 728
1 Sep 1995
McCallum J Scott R

Osteoarthritis of the medial compartment of the knee often shows a specific pattern of anterior wear. Review of our revisions from a series of medial metal-backed Brigham unicondylar knee replacements performed between 1983 and 1989 showed that this wear pattern was common on the tibial polyethylene surface. We reviewed these cases retrospectively to compare the pattern of preoperative erosion with the wear of the prosthesis. In all 14 knees with severe anterior wear in a unicompartmental replacement, the prearthroplasty radiographs showed similar patterns, suggesting that the implanted tibial component may continue to be subjected to the same localised stresses that precipitated the failure of the original articular cartilage. Many tibial components implanted during the 1980s had an unacceptably thin anterior rim of polyethylene and it seems that greater thickness is essential at the anterior and peripheral margins of the tibial plateau


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 2 | Pages 211 - 216
1 Mar 2000
Brunet JA

The late results of treatment of calcaneal fractures in 17 children (19 fractures) were reviewed at a mean of 16.8 years after injury. With the exception of one patient, all fractures had been treated conservatively. At follow-up there were few complaints. All but two patients had full or slightly reduced mobility of the subtalar joint and unrestricted foot function, including the ability to walk comfortably on uneven surfaces. Minor radiological abnormalities of the hindfoot were common; there were two cases of post-traumatic osteoarthritis. Clinical scoring of the ankle and hindfoot using the American Orthopaedic Foot and Ankle Society rating system averaged 96.2 points. The results suggest that up to 16.8 years after injury almost all children achieve excellent long-term functional results with conservative treatment of fractures of the os calcis. Open management may only be appropriate for adolescents with severe displacements


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 4 | Pages 639 - 640
1 Jul 1990
Messieh S Fowler P Munro T

Destruction of the articular cartilage is the first change seen on gross examination of the knee in osteoarthritis. Weight-bearing radiographs are conventionally taken with the knee in full extension. Biomechanical studies have shown, however, that the major contact stresses in the femorotibial articulation occur when the knee is flexed about 28 degrees. Arthroscopy has confirmed that cartilage loss occurs in a more posterior portion of the femoral condyles than is revealed by radiographs taken in full extension. The 'standing tunnel view' is a weight-bearing postero-anterior radiograph taken with the knee in 30 degrees of flexion. The radiographs of 64 patients have been used to compare the conventional with the standing tunnel view. In 10 knees in which the conventional view suggested normal cartilage the standing tunnel view revealed severe degeneration


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 4 | Pages 604 - 608
1 May 2001
Fink B Berger I Siegmüller C Fassbender H Meyer-Scholten C Tillmann K Rüther W

We evaluated histologically samples of synovial tissue from the knees of 50 patients with rheumatoid arthritis (RA). The samples were taken during revision for aseptic loosening. The findings were compared with those in 64 knees with osteoarthritis (OA) and aseptic loosening and in 18 knees with RA without loosening. The last group had been revised because of failure of the inlay or the coupling system of a constrained prosthesis. All the patients had had a total ventral synovectomy before implantation of the primary prosthesis. In all three groups a foreign-body reaction and lymphocellular infiltration were seen in more than 80% of the tissue samples. Deposits of fibrin were observed in about one-third to one-half of the knees in all groups. Typical signs of the reactivation of RA such as rheumatoid necrosis and/or proliferation of synovial stromal cells were found in 26% of knees with RA and loosening, but not in those with OA and loosening and in those with RA without loosening. Our findings show that reactivation of rheumatoid synovitis occurs after total knee replacement and may be a cofactor in aseptic loosening in patients with RA


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 3 | Pages 435 - 439
1 May 1988
Broughton N Todd R Dunn D Angel J

The results of open reduction of the severely slipped upper femoral epiphysis are reported for 115 hips with an average follow-up of 12 years 11 months (range 2 to 33 years). In 70 hips with a chronic slip and an open growth plate the incidence of complications was low: two developed avascular necrosis, five chondrolysis, and one had both. There were more complications in the 38 hips with an acute-on-chronic slip: six developed avascular necrosis, one chondrolysis, and three had both. Of the seven hips operated upon with a partially fused plate, only one did well. All these complications were obvious within the first year but there were also three hips in the series in which osteoarthritis developed between 10 and 20 years after operation


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 6 | Pages 807 - 810
1 Nov 1992
Emerson R Head W Peters P

We reviewed two similar groups of patients with medial osteoarthritis of the knee treated by unicompartmental arthroplasty. The group receiving an Oxford meniscal-bearing implant, with no medial release, showed significantly better mechanical alignment than that receiving a fixed-bearing implant. Under-correction, with its ominous mechanical implications, was much more common with the fixed-bearing design. Over-correction was rare and was seen in both designs about equally. Degenerative stenosis of the intercondylar notch was common and appeared to put the anterior cruciate ligament at risk of rupture, especially after correction of the varus deformity. We consider that postoperative leg alignment and soft-tissue balance after unicompartmental knee replacement are determined more by the implant design and the surgical technique than by any variation in soft-tissue contracture. Release of the medial collateral ligament is not necessary for realignment, but a generous notchplasty is often needed to allow normal anterior cruciate ligament function


The Journal of Bone & Joint Surgery British Volume
Vol. 58-B, Issue 2 | Pages 184 - 192
1 May 1976
Fitzgerald J Newman P

A clinical study has been made of forty-three patients with symptoms arising from degenerative spondylolisthesis of the lumbar spine. Attention is drawn to the lower average level of the iliac crests in these patients, and to the high incidence of osteoarthritis of the hips. Many patients in this series had been referred specifically for operation and fourteen were so treated. The techniques of decompression and of spinal fusion are discussed. It is concluded that patients with back pain predominant are well treated by corsetry, only a minority needing fusion, and that patients with nerve root involvement or with symptoms of spinal stenosis need decompression. The place of spinal fusion is the main problem, but it seems reasonable, firstly, in younger patients with clear evidence of instability and degenerative change at a single level, and secondly, when radical decompression is judged to increase the risk of instability


The Journal of Bone & Joint Surgery British Volume
Vol. 58-B, Issue 1 | Pages 79 - 83
1 Feb 1976
Feith R Slooff T Kazem I van Rens T

In a series of seventeen patients with unilateral osteoarthritis of the hip a scintiscanning follow-up study was made before and after total hip replacement for the assessment of the normal course of the 87mSr-scintiscan. In another series of twenty-eight patients with total hip replacement a photoscan was made as a supplement for the diagnosis of loosening of one or both components of a total hip implant. In most of these cases it proved to be a useful method, especially when clinical and raidological examination was inconclusive. It is concluded that up to six months after operation increased osteoblastic activity exists; the scintiscan became normal after that time. 87mSr scintiscanning offers a safe and simple technique for the assessment of the success and stability of total hip arthroplasty. It is also a useful aid for the early detection of loosening and infection. The procedure can help in the differential diagnosis of complaints after total hip replacement


The Journal of Bone & Joint Surgery British Volume
Vol. 51-B, Issue 2 | Pages 252 - 262
1 May 1969
Fairbank TJ

This series, albeit consecutive and unselected, is very small; conclusions must therefore be tentative. The results do however suggest that the dangers of late manipulative reduction properly performed may have been exaggerated. Attempted without undue force it proved a harmless procedure, often successful even in cases of long duration. When it succeeds, the results in slips of unacceptable degree are at least as good as those following the more major surgical procedures, which can thus be avoided. Even when the displacement is minor its correction should on theoretical grounds at least decrease the prospects of later osteoarthritis. The only absolute contra-indication is a fused epiphysial plate. The degree of slip and above all the duration of symptoms should not preclude an attempt at manipulative reduction


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 7 | Pages 975 - 979
1 Sep 2003
Therbo M Petersen MM Varmarken J Olsen CA Lund B

Between 1986 and 1991, 106 patients (127 knees) underwent uncemented knee arthroplasty for osteoarthritis. There were 106 total knee arthroplasties and 21 medial unicompartmental knee arthroplasties. The arthroplasties were evaluated for aseptic loosening during the year 2000. For total arthroplasty we used 77 porous-coated anatomic prostheses and 29 press-fit condylar prostheses. The mean bone mineral content of the proximal tibia, measured the day before surgery using dual-photon absorptiometry was 5.48 g/cm for the porous-coated anatomic prostheses which were revised for aseptic loosening (n = 9). This was significantly higher (p = 0.02) than the mean of 4.33 g/cm for those which were not revised. Values for the two revised press-fit condylar knees (4.78 and 4.93 g/cm) were above the mean value (4.23 g/cm) for those which were not revised. We found no statistically significant (p = 0.38) difference between the bone mineral content of the 12 revised and nine unrevised unicompartmental arthroplasties. Low trabecular bone quality, measured as the pre-operative bone mineral content of the proximal tibia, was not a predictor for later revision surgery following uncemented total knee or unicompartmental knee arthroplasty