Advertisement for orthosearch.org.uk
Results 1541 - 1560 of 2624
Results per page:
Bone & Joint 360
Vol. 8, Issue 5 | Pages 33 - 35
1 Oct 2019


The Journal of Bone & Joint Surgery British Volume
Vol. 68-B, Issue 1 | Pages 151 - 153
1 Jan 1986
Greenough C

A study of the contamination of suckers used during total hip replacement has been undertaken. Thirty suckers used throughout the operation had their tips cultured: from 11 of these bacteria were grown. The organisms found were those which have previously been implicated in deep infection of total hip replacements. In subsequent operations a further 31 suckers were used for cleaning only the femoral shaft; of these only one was contaminated. This suggests that sucker contamination is related to how long the sucker is in use; consequently it is recommended that a new sucker be used for the preparation of the femoral shaft


Bone & Joint Research
Vol. 8, Issue 10 | Pages 489 - 494
1 Oct 2019
Klasan A Bäumlein M Dworschak P Bliemel C Neri T Schofer MD Heyse TJ

Objectives

Periprosthetic femoral fractures (PFFs) have a higher incidence with cementless stems. The highest incidence among various cementless stem types was observed with double-wedged stems. Short stems have been introduced as a bone-preserving alternative with a higher incidence of PFF in some studies. The purpose of this study was a direct load-to-failure comparison of a double-wedged cementless stem and a short cementless stem in a cadaveric fracture model.

Methods

Eight hips from four human cadaveric specimens (age mean 76 years (60 to 89)) and eight fourth-generation composite femurs were used. None of the cadaveric specimens had compromised quality (mean T value 0.4 (-1.0 to 5.7)). Each specimen from a pair randomly received either a double-wedged stem or a short stem. A materials testing machine was used for lateral load-to-failure test of up to a maximal load of 5000 N.


The Bone & Joint Journal
Vol. 101-B, Issue 2 | Pages 198 - 206
1 Feb 2019
Salib CG Reina N Perry KI Taunton MJ Berry DJ Abdel MP

Aims

Concurrent hip and spine pathologies can alter the biomechanics of spinopelvic mobility in primary total hip arthroplasty (THA). This study examines how differences in pelvic orientation of patients with spine fusions can increase the risk of dislocation risk after THA.

Patients and Methods

We identified 84 patients (97 THAs) between 1998 and 2015 who had undergone spinal fusion prior to primary THA. Patients were stratified into three groups depending on the length of lumbar fusion and whether or not the sacrum was involved. Mean age was 71 years (40 to 87) and 54 patients (56%) were female. The mean body mass index (BMI) was 30 kg/m2 (19 to 45). Mean follow-up was six years (2 to 17). Patients were 1:2 matched to patients with primary THAs without spine fusion. Hazard ratios (HR) were calculated.


Bone & Joint 360
Vol. 8, Issue 5 | Pages 16 - 19
1 Oct 2019


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 6 | Pages 755 - 761
1 Jun 2012
Bosker BH Ettema HB Boomsma MF Kollen BJ Maas M Verheyen CCPM

Peri-articular soft-tissue masses or ‘pseudotumours’ can occur after large-diameter metal-on-metal (MoM) resurfacing of the hip and conventional total hip replacement (THR). Our aim was to assess the incidence of pseudotumour formation and to identify risk factors for their formation in a prospective cohort study. A total of 119 patients who underwent 120 MoM THRs with large-diameter femoral heads between January 2005 and November 2007 were included in the study. Outcome scores, serum metal ion levels, radiographs and CT scans were obtained. Patients with symptoms or an identified pseudotumour were offered MRI and an ultrasound-guided biopsy. There were 108 patients (109 hips) eligible for evaluation by CT scan at a mean follow-up of 3.6 years (2.5 to 4.5); 42 patients (39%) were diagnosed with a pseudotumour. The hips of 13 patients (12%) were revised to a polyethylene acetabular component with small-diameter metal head. Patients with elevated serum metal ion levels had a four times increased risk of developing a pseudotumour. This study shows a substantially higher incidence of pseudotumour formation and subsequent revisions in patients with MoM THRs than previously reported. Because most revision cases were identified only after an intensive screening protocol, we recommend close monitoring of patients with MoM THR


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 2 | Pages 158 - 162
1 Feb 2005
Itayem R Arndt A Nistor L McMinn D Lundberg A

The Birmingham hip resurfacing metal-on-metal arthroplasty was introduced in 1997 and has shown promising short- to mid-term results. We used radiostereophotogrammetric analysis (RSA) to study the stability of 20 resurfacing arthroplasties over a follow-up period of 24 months. Radiological examinations for RSA were performed immediately after surgery and at two, six, 12 and 24 months after operation. Precision and detection of migration thresholds (non-zero movement) were calculated. All the results corresponded well to those found in similar experimental arrangements with standard hip prostheses. Migration of the cup and vertical and mediolateral migration of the head were calculated. The values were low at two years compared with those of earlier studies of cemented femoral components in conventional total hip replacements indicating that there was no evidence of excessive early migration or loosening of the components


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 2 | Pages 257 - 260
1 Mar 1992
Mont M Maar D Krackow K Hungerford D

Retrospective review of 730 consecutive primary uncemented and cemented total hip arthroplasties revealed 19 intra-operative hoop-stress fractures of the femoral neck. These were incomplete, linear, and minimally displaced. Management was by cerclage wiring (12), bone graft and cerclage (two), further impaction (two), and the use of cement (three), with no change from our standard postoperative management and rehabilitation. Eighteen patients had excellent or good results with an average Harris hip score of 93. Radiographically, all but one patient had Engh stability-fixation scores consistent with stable bone ingrowth. We conclude that hoop-stress fractures of the proximal femur, properly managed, do not detract from the results of total hip arthroplasty


The Bone & Joint Journal
Vol. 101-B, Issue 7_Supple_C | Pages 64 - 69
1 Jul 2019
Wodowski AJ Pelt CE Erickson JA Anderson MB Gililland JM Peters CL

Aims

The Bundled Payments for Care Improvement (BPCI) initiative has identified pathways for improving the value of care. However, patient-specific modifiable and non-modifiable risk factors may increase costs beyond the target payment. We sought to identify risk factors for exceeding our institution’s target payment, the so-called ‘bundle busters’.

Patients and Methods

Using our data warehouse and Centers for Medicare and Medicaid Services (CMS) data we identified all 412 patients who underwent total joint arthroplasty and qualified for our institution’s BPCI model, between July 2015 and May 2017. Episodes where CMS payments exceeded the target payment were considered ‘busters’ (n = 123). Risk ratios (RRs) were calculated using a modified Poisson regression analysis.


The Bone & Joint Journal
Vol. 101-B, Issue 10 | Pages 1186 - 1191
1 Oct 2019
Amstutz HC Le Duff MJ

Aims

In previous studies, we identified multiple factors influencing the survivorship of hip resurfacing arthroplasties (HRAs), such as initial anatomical conditions and surgical technique. In addition, the University of California, Los Angeles (UCLA) activity score presents a ceiling effect, so a better quantification of activity is important to determine which activities may be advisable or detrimental to the recovered patient. We aimed to determine the effect of specific groups of sporting activities on the survivorship free of aseptic failure of a large series of HRA.

Patients and Methods

A total of 661 patients (806 hips) representing 77% of a consecutive series of patients treated with metal-on-metal hybrid HRA answered a survey to determine the types and amounts of sporting activities they regularly participated in. There were 462 male patients (70%) and 199 female patients (30%). Their mean age at the time of surgery was 51.9 years (14 to 78). Their mean body mass index (BMI) was 26.5 kg/m2 (16.7 to 46.5). Activities were regrouped into 17 categories based on general analogies between these activities. Scores for typical frequency and duration of the sessions were used to quantify the patients’ overall time spent engaging in sporting activities. Impact and cycle scores were computed. Multivariable models were used.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 9 | Pages 1220 - 1221
1 Sep 2005
Wroblewski BM Siney PD Fleming PA

We report the results of our continued review of 11 total hip arthroplasties using 22.225 mm alumina ceramic femoral heads on a Charnley flanged stem, articulating with chemically cross-linked polyethylene. There was an initial bedding-in of up to 0.41 mm at the articular surface in the first two years. This had not progressed further, at a minimum follow-up of 15 years. Radiographically no femoral or acetabular component showed loosening or osteolysis


The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 2 | Pages 264 - 267
1 Mar 1987
Brown J Ward P Wilkinson A Mollan R

Impedance plethysmography has great potential in the non-invasive detection of dangerous iliofemoral thrombosis. It was used to examine 198 patients undergoing total hip replacement for evidence of proximal venous segment thrombosis. There were 13 abnormal results, and subsequent venography in 12 of these revealed a false-positive rate of 4.0%; there was one false-negative result giving a sensitivity of 85.7%. A venographic study of 46 other patients clinically suspected of having a proximal deep-vein thrombosis confirmed this sensitivity. The iliofemoral thrombosis rate was 3.9% after total hip replacement and this rate increased significantly in the group of patients over 70 kg in weight. Impedance plethysmography was found to be a useful non-invasive screening procedure for potentially fatal proximal venous thrombosis


Bone & Joint Research
Vol. 1, Issue 9 | Pages 225 - 233
1 Sep 2012
Paulsen A Odgaard A Overgaard S

Objectives. The Oxford hip score (OHS) is a 12-item questionnaire designed and developed to assess function and pain from the perspective of patients who are undergoing total hip replacement (THR). The OHS has been shown to be consistent, reliable, valid and sensitive to clinical change following THR. It has been translated into different languages, but no adequately translated, adapted and validated Danish language version exists. Methods. The OHS was translated and cross-culturally adapted into Danish from the original English version, using methods based on best-practice guidelines. The translation was tested for psychometric quality in patients drawn from a cohort from the Danish Hip Arthroplasty Register (DHR). Results. The Danish OHS had a response rate of 87.4%, no floor effect and a 19.9% ceiling effect (as expected in post-operative patients). Only 1.2% of patients had too many items missing to calculate a sum score. Construct validity was adequate and 80% of our predefined hypotheses regarding the correlation between scores on the Danish OHS and the other questionnaires were confirmed. The intraclass correlation (ICC) of the different items ranged from 0.80 to 0.95 and the average limits of agreement (LOA) ranged from -0.05 to 0.06. The Danish OHS had a high internal consistency with a Cronbach’s alpha of 0.99 and an average inter-item correlation of 0.88. Conclusions. This Danish version of the OHS is a valid and reliable patient-reported outcome measurement instrument (PROM) with similar qualities to the original English language version.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 11 | Pages 1425 - 1429
1 Nov 2006
Old AB McGrory BJ White RR Babikian GM

The use of allograft struts and cerclage wire, possibly augmented by plate fixation, for the treatment of Vancouver type-B1 peri-prosthetic fractures around a total hip replacement has been strongly advocated. We examined our results using plate fixation without allograft struts and compared them with the results of the use of struts alone or when combined with plate fixation. Of 20 consecutive patients with type-B1 fractures treated by open reduction and plate fixation, 19 were available for follow-up. The fractures healed in 18 patients with a mean time to weight-bearing of ten weeks (4 to 19). There were no cases of infection or malunion. Nonunion occurred in one patient and required a second plate fixation to achieve union. Safe, cost-effective treatment of Vancouver type-B1 fractures can be performed by plate fixation without the addition of cortical struts. This procedure may allow earlier weight-bearing than allograft strut fixation alone


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 2 | Pages 259 - 265
1 Mar 1999
Smith PN Ling RSM Taylor R

We have studied the influence of weight-bearing on the measurement of wear of the polyethylene acetabular component in total hip arthroplasty using two techniques. The measured vertical wear was significantly greater when radiographs were taken weight-bearing rather than with the patient supine (p = 0.001, method 1; p = 0.007, method 2). Calculations of rates of linear wear of the acetabular component were significantly underestimated (p < 0.05) when radiographs were taken supine. There are two reasons for this. First, a change in pelvic orientation when bearing weight ensures that the thinnest polyethylene is brought into relief, and secondly, the head of the femoral component assumes the position of maximal displacement along its wear path. Interpretation of previous studies on both linear and volumetric polyethylene wear in total hip arthroplasty should be reassessed in the light of these findings


The Bone & Joint Journal
Vol. 95-B, Issue 11 | Pages 1582 - 1582
1 Nov 2013
Haddad FS

Kazi HA, Perera JR, Gillott E, Carroll FA, Briggs TW. A prospective study of a ceramic-on-metal bearing in total hip arthroplasty: Clinical results, metal ion levels and chromosome analysis at two years. Bone Joint J 2013;95-B:1040-1044


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 2 | Pages 191 - 198
1 Mar 2003
Hasegawa Y Sakano S Iwase T Iwasada S Torii S Iwata H

Segmental collapse occurs in the early stage of a vascular necrosis (AVN) of the femoral head, and is associated with a poor prognosis. Since it develops at a relatively young age, the long-term outcome after total hip replacement is a major concern. We have compared the long-term results of pedicle bone grafting (PBG) with those of transtrochanteric rotational osteotomy (TRO). In the PBG group there were 23 men (27 hips) and three women (4 hips) with a mean age at the time of surgery of 38 years and a mean follow-up of 13 years. In the TRO group there were 44 men (55 hips) and 19 women (22 hips) with a mean age at the time of surgery of 39 years and a mean follow-up of seven years. Failure was defined as a need for total hip replacement or a Harris hip score below 70. The long-term results were similar for the two groups. The survival rates at five and ten years were 85% and 67%, respectively, in the PBG group, and 71% and 61%, respectively, in the TRO group, according to Kaplan-Meier survivorship analysis. In the TRO group patients in stage II had significantly better results that those in stage III


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 10 | Pages 1309 - 1316
1 Oct 2007
Gosvig KK Jacobsen S Palm H Sonne-Holm S Magnusson E

Femoroacetabular cam impingement is thought to be a cause of premature osteoarthritis of the hip. The presence of cam malformation was determined in 2803 standardised anteroposterior (AP) pelvic radiographs from the Copenhagen Osteoarthritis Study by measuring the alpha (α) angle and the triangular index, a new measure of asphericity of the femoral head. In addition, the α-angle and the triangular index were assessed on the AP and lateral hip radiographs of 82 men and 82 women randomly selected from patients scheduled for total hip replacement (THR). The influence of varying femoral rotation on the α angle and the triangular index was also determined in femoral specimens under experimental conditions. From the 2803 radiographs the mean AP α-angle was 55° (30° to 100°) in men and 45° (34° to 108°) in women. Approximately 6% of men and 2% of women had cam malformation. The α-angle and triangular index were highly inter-related. Of those patients scheduled for THR, 36 men (44%) and 28 women (35%) had cam malformation identifiable on the AP radiographs. The triangular index proved to be more reliable in detecting cam malformation when the hip was held in varying degrees of rotation. The combination of the α-angle and the triangular index will allow examination of historical radiographs for epidemiological purposes in following the natural history of the cam deformity


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 7 | Pages 969 - 974
1 Sep 2003
Drescher W Fürst M Hahne HJ Helfenstein A Petersen W Hassenpflug J

The treatment of osteonecrosis of the femoral head (FHN) is controversial. It mainly occurs in young patients in whom total hip replacement is best avoided because of an increased risk of revision. The objective of this long-term follow-up study was to evaluate the outcome of intertrochanteric flexion osteotomy as a hip joint preserving operation for FHN. Over a 19-year period we carried out 70 intertrochanteric flexion osteotomies for FHN in 64 patients. The mean follow-up was 10.4 years (3.0 to 20.3). The overall mean Harris hip score increased from 51 points preoperatively to 71 points postoperatively. Six patients (9%) developed early postoperative complications. A total of 19 hips (27%) underwent total hip arthroplasty at a mean of 8.7 years after osteotomy. The five-year survival rate was 90%. Survival rates of hips in Ficat stage 2 were higher than those in stages 3 or 4. Hips with a preoperative necrotic angle of < 200° had a better survival probability than those with a necrotic angle > 200°. Our findings suggest that flexion osteotomy is a safe and effective procedure in Ficat stage 2 and 3 FHN, preferably with a necrotic angle of < 200°


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 2 | Pages 238 - 242
1 Feb 2006
Khan RJK Fick D Yao F Tang K Hurworth M Nivbrant B Wood D

We carried out a blinded prospective randomised controlled trial comparing 2-octylcyanoacrylate (OCA), subcuticular suture (monocryl) and skin staples for skin closure following total hip and total knee arthroplasty. We included 102 hip replacements and 85 of the knee. OCA was associated with less wound discharge in the first 24 hours for both the hip and the knee. However, with total knee replacement there was a trend for a more prolonged wound discharge with OCA. With total hip replacement there was no significant difference between the groups for either early or late complications. Closure of the wound with skin staples was significantly faster than with OCA or suture. There was no significant difference in the length of stay in hospital, Hollander wound evaluation score (cosmesis) or patient satisfaction between the groups at six weeks for either hips or knees. We consider that skin staples are the skin closure of choice for both hip and knee replacements