Lindahl H Malchau H Odén A Garellick G

Periprosthetic fracture of the femur is an uncommon complication after total hip replacement, but appears to be increasing. We undertook a nationwide observational study to determine the risk factors for failure after treatment of these fractures, examining patient- and implant-related factors, the classification of the fractures and the outcome.

Between 1979 and 2000, 1049 periprosthetic fractures of the femur were reported to the Swedish National Hip Arthroplasty Register. Of these, 245 had a further operation after failure of their initial management. Data were collected from the Register and hospital records. The material was analysed by the use of Poisson regression models.

It was found that the risk of failure of treatment was reduced for Vancouver type B2 injuries (p = 0.0053) if revision of the implant was undertaken (p = 0.0033) or revision and open reduction and internal fixation (p = 0.0039) were performed. Fractures classified as Vancouver type B1 had a significantly higher risk of failure (p = 0.0001). The strongest negative factor was the use of a single plate for fixation (p = 0.001). The most common reasons for failure in this group were loosening of the femoral prosthesis, nonunion and re-fracture.

It is probable that many fractures classified as Vancouver type B1 (n = 304), were in reality type B2 fractures with a loose stem which were not recognised. Plate fixation was inadequate in these cases. The difficulty in separating type B1 from type B2 fractures suggests that the prosthesis should be considered as loose until proven otherwise.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 7 | Pages 965 - 968
1 Jul 2005
Stannard JP Singhania AK Lopez-Ben RR Anderson ER Farris RC Volgas DA McGwin GR Alonso JE

We report the incidence and location of deep-vein thrombosis in 312 patients who had sustained high-energy, skeletal trauma. They were investigated using magnetic resonance venography and Duplex ultrasound.

Despite thromboprophylaxis, 36 (11.5%) developed venous thromboembolic disease with an incidence of 10% in those with non-pelvic trauma and 12.2% in the group with pelvic trauma. Of patients who developed deep-vein thrombosis, 13 of 27 in the pelvic group (48%) and only one of nine in the non-pelvic group (11%) had a definite pelvic deep-vein thrombosis. When compared with magnetic resonance venography, ultrasound had a false-negative rate of 77% in diagnosing pelvic deep-vein thrombosis. Its value in the pelvis was limited, although it was more accurate than magnetic resonance venography in diagnosing clots in the lower limbs. Additional screening may be needed to detect pelvic deep-vein thrombosis in patients with pelvic or acetabular fractures.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 7 | Pages 960 - 966
1 Jul 2006
Pluhar GE Turner AS Pierce AR Toth CA Wheeler DL

Critical size defects in ovine tibiae, stabilised with intramedullary interlocking nails, were used to assess whether the addition of carboxymethylcellulose to the standard osteogenic protein-1 (OP-1/BMP-7) implant would affect the implant’s efficacy for bone regeneration. The biomaterial carriers were a ‘putty’ carrier of carboxymethylcellulose and bovine-derived type-I collagen (OPP) or the standard with collagen alone (OPC). These two treatments were also compared to “ungrafted” negative controls. Efficacy of regeneration was determined using radiological, biomechanical and histological evaluations after four months of healing. The defects, filled with OPP and OPC, demonstrated radiodense material spanning the defect after one month of healing, with radiographic evidence of recorticalisation and remodelling by two months. The OPP and OPC treatment groups had equivalent structural and material properties that were significantly greater than those in the ungrafted controls. The structural properties of the OPP- and OPC-treated limbs were equivalent to those of the contralateral untreated limb (p > 0.05), yet material properties were inferior (p < 0.05). Histopathology revealed no residual inflammatory response to the biomaterial carriers or OP-1. The OPP- and OPC-treated animals had 60% to 85% lamellar bone within the defect, and less than 25% of the regenerate was composed of fibrous tissue. The defects in the untreated control animals contained less than 40% lamellar bone and more than 60% was fibrous tissue, creating full cortical thickness defects. In our studies carboxymethylcellulose did not adversely affect the capacity of the standard OP-1 implant for regenerating bone.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 10 | Pages 1328 - 1332
1 Oct 2005
Moonot P Ashwood N Lockwood D


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 3 | Pages 386 - 391
1 Mar 2006
Bjørnar̊ BT Gudmundsen TE Dahl OE

Over a 13-year period we studied all patients who underwent major hip and knee surgery and were diagnosed with objectively confirmed symptomatic venous thromboembolism, either deep venous thrombosis or non-fatal pulmonary embolism, within six months after surgery. Low-molecular-weight heparin had been given while the patients were in hospital.

There were 5607 patients. The cumulative incidence of symptomatic venous thromboembolism was 2.7% (150 of 5607), of which 1.1% had developed pulmonary embolism, 1.5% had deep venous thrombosis and 0.6% had both. Patients presented with deep venous thrombosis at a median of 24 days and pulmonary embolism at 17 days after surgery for hip fracture. After total hip replacement, deep venous thrombosis and pulmonary embolism occurred at a median of 21 and 34 days respectively. After total knee replacement, the median time to the presentation of deep venous thrombosis and pulmonary embolism was 20 and 12 days respectively. The cumulative risk of venous thromboembolism lasted for up to three months after hip surgery and for one month after total knee replacement. Venous thromboembolism was diagnosed after discharge from hospital in 70% of patients who developed this complication.

Despite hospital-based thromboprophylaxis, most cases of clinical venous thromboembolism occur after discharge and at different times according to the operation performed.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 11 | Pages 1488 - 1492
1 Nov 2005
Price AJ Dodd CAF Svard UGC Murray DW

We present a comparison of the results of the Oxford unicompartmental knee arthroplasty in patients younger and older than 60 years of age. The ten-year all-cause survival of the < 60 years of age group (52) was 91% (95% confidence interval (CI) 12), while in the ≥ 60 years of age group (512), the figure was 96% (95% CI 3). For the younger group, the mean Hospital for Special Surgery score at ten-year follow-up (n = 21) was 94 of 100, compared with a mean of 86 of 100 for the older group (n = 135). The results show that the Oxford unicompartmental arthroplasty can achieve ten-year results that are comparable to total knee arthroplasty in patients < 60 years of age. We conclude that for patients aged over 50, age should not be considered a contraindication for this procedure.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 11 | Pages 1480 - 1486
1 Nov 2006
Pradhan A Cheung YC Grimer RJ Abudu A Peake D Ferguson PC Griffin AM Wunder JS O’Sullivan B Hugate R Sim FH

We have investigated the significance of the method of treatment on the oncological and functional outcomes and on the complications in 184 patients with soft-tissue sarcomas of the adductor compartment managed at three international centres. The overall survival at five years was 65% and was related to the grade at diagnosis and the size of the tumour. There was no difference in overall survival between the three centres. There was, however, a significant difference in local control with a rate of 28% in Centre 1 compared with 10% in Centre 2 and 5% in Centre 3.

The overall mean functional score using the Toronto Extremity Salvage Score in 70 patients was 77% but was significantly worse in patients with wound complications or high-grade tumours. The scores were not affected by the timing of radiotherapy or the use of muscle flaps.

This large series of soft-tissue sarcomas of the adductor compartment has shown that factors influencing survival do not vary across the international boundaries studied, but that methods of treatment affect complications, local recurrence and function.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 12 | Pages 1605 - 1610
1 Dec 2005
Rathur HM Boulton AJM


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 6 | Pages 770 - 775
1 Jun 2005
Hsieh P Shih C Chang Y Lee MS Yang W Shih H

We have carried out in 24 patients, a two-stage revision arthroplasty of the hip for infection with massive bone loss. We used a custom-made, antibiotic-loaded cement prosthesis as an interim spacer. Fifteen patients had acetabular deficiencies, eight had segmental femoral bone loss and one had a combined defect.

There was no recurrence of infection at a mean follow-up of 4.2 years (2 to 7). A total of 21 patients remained mobile in the interim period. The mean Merle D’Aubigné and Postel hip score improved from 7.3 points before operation to 13.2 between stages and to 15.8 at the final follow-up. The allograft appeared to have incorporated into the host bone in all patients. Complications included two fractures and one dislocation of the cement prosthesis.

The use of a temporary spacer maintains the function of the joint between stages even when there is extensive loss of bone. Allograft used in revision surgery after septic conditions restores bone stock without the risk of recurrent infection.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 3 | Pages 351 - 357
1 Mar 2006
Naique SB Pearse M Nanchahal J

Although it is widely accepted that grade IIIB open tibial fractures require combined specialised orthopaedic and plastic surgery, the majority of patients in the UK initially present to local hospitals without access to specialised trauma facilities. The aim of this study was to compare the outcome of patients presenting directly to a specialist centre (primary group) with that of patients initially managed at local centres (tertiary group).

We reviewed 73 consecutive grade IIIB open tibial shaft fractures with a mean follow-up of 14 months (8 to 48). There were 26 fractures in the primary and 47 in the tertiary group. The initial skeletal fixation required revision in 22 (47%) of the tertiary patients. Although there was no statistically-significant relationship between flap timing and flap failure, all the failures (6 of 63; 9.5%) occurred in the tertiary group. The overall mean time to union of 28 weeks was not influenced by the type of skeletal fixation. Deep infection occurred in 8.5% of patients, but there were no persistently infected fractures. The infection rate was not increased in those patients debrided more than six hours after injury.

The limb salvage rate was 93%. The mean limb functional score was 74% of that of the normal limb. At review, 67% of patients had returned to employment, with a further 10% considering a return after rehabilitation. The times to union, infection rates and Enneking limb reconstruction scores were not statistically different between the primary and tertiary groups.

The increased complications and revision surgery encountered in the tertiary group suggest that severe open tibial fractures should be referred directly to specialist centres for simultaneous combined management by orthopaedic and plastic surgeons.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 6 | Pages 783 - 789
1 Jun 2006
Sen C Eralp L Gunes T Erdem M Ozden VE Kocaoglu M

In this retrospective study we evaluated the method of acute shortening and distraction osteogenesis for the treatment of tibial nonunion with bone loss in 17 patients with a mean age of 36 years (10 to 58). The mean bone loss was 5.6 cm (3 to 10). In infected cases, we performed the treatment in two stages. The mean follow-up time was 43.5 months (24 to 96). The mean time in external fixation was 8.0 months (4 to 13) and the mean external fixator index was 1.4 months/cm (1.1 to 1.8). There was no recurrence of infection. The bone evaluation results were excellent in 16 patients and good in one, while functional results were excellent in 15 and good in two. The complication rate was 1.2 per patient.

We conclude that acute shortening and distraction osteogenesis is a safe, reliable and successful method for the treatment of tibial nonunion with bone loss, with a shorter period of treatment and lower rate of complication.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 1 | Pages 80 - 88
1 Jan 2007
El-Rosasy MA

We have managed 21 patients with a fracture of the tibia complicated by bone and soft-tissue loss as a result of an open fracture in 10, or following debridement of an infected nonunion in 11, by resection of all the devitalised tissues, acute limb shortening to close the defect, application of an external fixator and metaphyseal osteotomy for re-lengthening. The mean bone loss was 4.7 cm (3 to 11). The mean age of the patients was 28.8 years (12 to 54) and the mean follow-up was 34.8 months (24 to 75).

All the fractures united with a well-aligned limb. The mean duration of treatment for the ten grade-III A+B open fractures (according to the Gustilo-Anderson classification) was 5.7 months (4.5 to 8) and for the nonunions, 7.6 months (5.5 to 12.5). Complications included one refracture, one transient palsy of the peroneal nerve and one equinus contracture of 10°.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 6 | Pages 790 - 795
1 Jun 2005
Eren A Ömeroglu H Güven M Ugutmen E Altintas F

We treated 26 hips (24 consecutive patients) with residual dysplasia by a technique of incomplete triple pelvic osteotomy. The mean age of the patients was 21.6 years.

The mean values for the pre-operative centre-edge angle of Wiberg, the refined centre-edge angle, the acetabular angle of Sharp, the modified acetabular angle and femoral head lateralisation were 7.7°, −3.1°, 49.3°, 53.2° and 17.2 mm, respectively. After a mean follow-up of 3.3 years they were 27.0°, 13.0°, 38.9°, 44.3° and 15.9 mm, respectively (p < 0.05). The osteoarthritic grading changed adversely in one hip. The mean pre-operative and latest Harris hip scores were 74.9 and 93.0, respectively (p < 0.05).

This technique provides a stable osteotomy with maintenance of the posterior column which allows early mobilisation and minimal internal fixation. The technique is not complex and requires minimal blood transfusion. The use of an image intensifier is not necessary and harvesting of a subcristal bone graft avoids post-operative complications at the donor site.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 9 | Pages 1267 - 1271
1 Sep 2005
Allami MK Jamil W Fourie B Ashton V Gregg PJ

The Department of Health and the Public Health Laboratory Service established the Nosocomial Infection National Surveillance Scheme in order to standardise the collection of information about infections acquired in hospital in the United Kingdom and provide national data with which hospitals could measure their own performance. The definition of superficial incisional infection (skin and subcutaneous tissue), set by the Center for Disease Control (CDC), should meet at least one of the defined criteria which would confirm the diagnosis and determine the need for specific treatment.

We have assessed the interobserver reliability of the criteria for superficial incisional infection set by the CDC in our current practice. The incisional site of 50 patients who had an elective primary arthroplasty of the hip or knee was evaluated independently by two orthopaedic clinical research fellows and two orthopaedic ward sisters for the presence or absence of surgical-site infection. Interobserver reliability was assessed by comparison of the criteria for wound infection used by the four observers using kappa reliability coefficients. Our study demonstrated that some of the components of the current CDC criteria were unreliable and we recommend their revision.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 12 | Pages 1675 - 1680
1 Dec 2005
Howie C Hughes H Watts AC

This population-based study investigated the incidence and trends in venous thromboembolic disease after total hip and knee arthroplasty over a ten-year period. Death or readmission for venous thromboembolic disease up to two years after surgery for all patients in Scotland was the primary outcome. The incidence of venous thromboembolic disease, including fatal pulmonary embolism, three months after surgery was 2.27% for primary hip arthroplasty and 1.79% for total knee arthroplasty. The incidence of fatal pulmonary embolism within three months was 0.22% for total hip arthroplasty and 0.15% for total knee arthroplasty. The majority of events occurred after hospital discharge, with no apparent trend over the period. The data support current advice that prophylaxis should be continued for at least six weeks following surgery. Despite the increased use of policies for prophylaxis and earlier mobilisation, there has been no change in the incidence of venous thromboembolic disease.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 8 | Pages 1053 - 1059
1 Aug 2006
Foss NB Kehlet H

Our aim was to determine the total blood loss associated with surgery for fracture of the hip and to identify risk factors for increased blood loss. We prospectively studied 546 patients with hip fracture. The total blood loss was calculated on the basis of the haemoglobin difference, the number of transfusions and the estimated blood volume. The hidden blood loss, in excess of that observed during surgery, varied from 547 ml (screws/ pins) to 1473 ml (intramedullary hip nail and screw) and was significantly associated with medical complications and increased hospital stay. The type of surgery, treatment with aspirin, intra-operative hypotension and gastro-intestinal bleeding or ulceration were all independent predictors of blood loss.

We conclude that total blood loss after surgery for hip fracture is much greater than that observed intra-operatively. Frequent post-operative measurements of haemoglobin are necessary to avoid anaemia.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 2 | Pages 149 - 155
1 Feb 2006
Toms AD Davidson D Masri BA Duncan CP


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 3 | Pages 343 - 347
1 Mar 2005
Winson IG Robinson DE Allen PE

We reviewed 116 patients who underwent 118 arthroscopic ankle arthrodeses. The mean age at operation was 57 years, 2 months (20 to 86 years). The indication for operation was post-traumatic osteoarthritis in 67, primary osteoarthritis in 36, inflammatory arthropathy in 13 and avascular necrosis in two. The mean follow-up was 65 months (18 to 144). Nine patients (10 ankles) died before final review and three were lost to follow-up, leaving 104 patients (105 ankles) who were assessed by a standard telephone interview. The pre-operative talocrural deformity was between 22° valgus and 28° varus, 94 cases were within 10° varus/valgus. The mean time to union was 12 weeks (6 to 20). Nonunion occurred in nine cases (7.6%). Other complications included 22 cases requiring removal of a screw for prominence, three superficial infections, two deep vein thromboses/pulmonary emboli, one revision of fixation, one stress fracture and one deep infection. Six patients had a subtalar fusion at a mean of 48 months after ankle fusion. There were 48 patients with excellent, 35 with good, 10 with fair and 11 with poor clinical results.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 6 | Pages 868 - 872
1 Jun 2005
Metcalfe AJ Saleh M Yang L

Biomechanical studies involving all-wire and hybrid types of circular frame have shown that oblique tibial fractures remain unstable when they are loaded. We have assessed a range of techniques for enhancing the fixation of these fractures. Eight models were constructed using Sawbones tibiae and standard Sheffield ring fixators, to which six additional fixation techniques were applied sequentially.

The major component of displacement was shear along the obliquity of the fracture. This was the most sensitive to any change in the method of fixation. All additional fixation systems were found to reduce shear movement significantly, the most effective being push-pull wires and arched wires with a three-hole bend. Less effective systems included an additional half pin and arched wires with a shallower arc. Angled pins were more effective at reducing shear than transverse pins.

The choice of additional fixation should be made after consideration of both the amount of stability required and the practicalities of applying the method to a particular fracture.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 1 | Pages 54 - 60
1 Jan 2006
Pandit H Jenkins C Barker K Dodd CAF Murray DW

This prospective study describes the complications and survival of the first 688 Phase 3 Oxford medial unicompartmental knee replacements implanted using a minimally-invasive technique by two surgeons and followed up independently. None was lost to follow-up. We had carried out 132 of the procedures more than five years ago. The clinical assessment of 101 of these which were available for review at five years is also presented.

Nine of the 688 knees were revised: four for infection, three for dislocation of the bearing and two for unexplained pain. A further seven knees (1%) required other procedures: four had a manipulation under anaesthesia, two an arthroscopy and one a debridement for superficial infection. The survival rate at seven years was 97.3% (95% confidence interval 5.3). At five years, 96% of the patients had a good or excellent American Knee Society score, the mean Oxford knee score was 39 and the mean flexion was 133°. This study demonstrates that the minimally-invasive Oxford unicompartmental knee replacement is a reliable and effective procedure.