This study aimed to evaluate whether an enhanced recovery protocol (ERP) for arthroplasty established during the COVID-19 pandemic at a safety net hospital can be associated with a decrease in hospital length of stay (LOS) and an increase in same-day discharges (SDDs) without increasing acute adverse events. A retrospective review of 124 consecutive primary arthroplasty procedures performed after resuming elective procedures on 11 May 2020 were compared to the previous 124 consecutive patients treated prior to 17 March 2020, at a single urban safety net hospital. Revision arthroplasty and patients with < 90-day follow-up were excluded. The primary outcome measures were hospital LOS and the number of SDDs. Secondary outcome measures included 90-day complications, 90-day readmissions, and 30day emergency department (ED) visits.Aims
Methods
This study aimed to evaluate the accuracy of implant placement with robotic-arm assisted total hip arthroplasty (THA) in patients with developmental dysplasia of the hip (DDH). The study analyzed a consecutive series of 69 patients who underwent robotic-arm assisted THA between September 2018 and December 2019. Of these, 30 patients had DDH and were classified according to the Crowe type. Acetabular component alignment and 3D positions were measured using pre- and postoperative CT data. The absolute differences of cup alignment and 3D position were compared between DDH and non-DDH patients. Moreover, these differences were analyzed in relation to the severity of DDH. The discrepancy of leg length and combined offset compared with contralateral hip were measured.Aims
Methods
The COVID-19 pandemic drastically affected elective orthopaedic services globally as routine orthopaedic activity was largely halted to combat this global threat. Our institution (University College London Hospital, UK) previously showed that during the first peak, a large proportion of patients were hesitant to be listed for their elective lower limb procedure. The aim of this study is to assess if there is a patient perception change towards having elective surgery now that we have passed the peak of the second wave of the pandemic. This is a prospective study of 100 patients who were on the waiting list of a single surgeon for an elective hip or knee procedure. Baseline characteristics including age, American Society of Anesthesiologists (ASA) grade, COVID-19 risk, procedure type, and admission type were recorded. The primary outcome was patient consent to continue with their scheduled surgical procedure. Subgroup analysis was also conducted to define if any specific patient factors influenced decision to continue with surgeryAims
Methods
Acetabular edge-loading was a cause of increased wear rates in metal-on-metal hip arthroplasties, ultimately contributing to their failure. Although such wear patterns have been regularly reported in retrieval analyses, this study aimed to determine their in vivo location and investigate their relationship with acetabular component positioning. 3D CT imaging was combined with a recently validated method of mapping bearing surface wear in retrieved hip implants. The asymmetrical stabilizing fins of Birmingham hip replacements (BHRs) allowed the co-registration of their acetabular wear maps and their computational models, segmented from CT scans. The in vivo location of edge-wear was measured within a standardized coordinate system, defined using the anterior pelvic plane.Aims
Methods
Orthopaedic surgeries are complex, frequently performed procedures associated with significant haemorrhage and perioperative blood transfusion. Given refinements in surgical techniques and changes to transfusion practices, we aim to describe contemporary transfusion practices in orthopaedic surgery in order to inform perioperative planning and blood banking requirements. We performed a retrospective cohort study of adult patients who underwent orthopaedic surgery at four Canadian hospitals between 2014 and 2016. We studied all patients admitted to hospital for nonarthroscopic joint surgeries, amputations, and fracture surgeries. For each surgery and surgical subgroup, we characterized the proportion of patients who received red blood cell (RBC) transfusion, the mean/median number of RBC units transfused, and exposure to platelets and plasma.Aims
Methods
Prior studies have identified that malseating of a modular dual mobility liner can occur, with previous reported incidences between 5.8% and 16.4%. The aim of this study was to determine the incidence of malseating in dual mobility implants at our institution, assess for risk factors for liner malseating, and investigate whether liner malseating has any impact on clinical outcomes after surgery. We retrospectively reviewed the radiographs of 239 primary and revision total hip arthroplasties with a modular dual mobility liner. Two independent reviewers assessed radiographs for each patient twice for evidence of malseating, with a third observer acting as a tiebreaker. Univariate analysis was conducted to determine risk factors for malseating with Youden’s index used to identify cut-off points. Cohen’s kappa test was used to measure interobserver and intraobserver reliability.Aims
Methods
This systematic review and meta-analysis was conducted to compare open reduction and internal fixation (ORIF) with primary arthrodesis (PA) in the treatment of Lisfranc injuries, regarding patient-reported outcome measures (PROMs), and risk of secondary surgery. The aim was to conclusively determine the best available treatment based on the most complete and recent evidence available. A systematic search was conducted in PubMed, Cochrane Controlled Register of Trials (CENTRAL), EMBASE, CINAHL, PEDro, and SPORTDiscus. Additionally, ongoing trial registers and reference lists of included articles were screened. Risk of bias (RoB) and level of evidence were assessed using the Cochrane risk of bias tools and the Grading of Recommendations Assessment, Development and Evaluation (GRADE) tool. The random and fixed-effect models were used for the statistical analysis.Aims
Methods
Pelvic tilt (PT) can significantly change the functional orientation of the acetabular component and may differ markedly between patients undergoing total hip arthroplasty (THA). Patients with stiff spines who have little change in PT are considered at high risk for instability following THA. Femoral component position also contributes to the limits of impingement-free range of motion (ROM), but has been less studied. Little is known about the impact of combined anteversion on risk of impingement with changing pelvic position. We used a virtual hip ROM (vROM) tool to investigate whether there is an ideal functional combined anteversion for reduced risk of hip impingement. We collected PT information from functional lateral radiographs (standing and sitting) and a supine CT scan, which was then input into the vROM tool. We developed a novel vROM scoring system, considering both seated flexion and standing extension manoeuvres, to quantify whether hips had limited ROM and then correlated the vROM score to component position.Aims
Methods
The study objective was to prospectively assess clinical outcomes for a pilot cohort of tibial shaft fractures treated with a new tibial nailing system that produces controlled axial interfragmentary micromotion. The hypothesis was that axial micromotion enhances fracture healing compared to static interlocking. Patients were treated in a single level I trauma centre over a 2.5-year period. Group allocation was not randomized; both the micromotion nail and standard-of-care static locking nails (control group) were commercially available and selected at the discretion of the treating surgeons. Injury risk levels were quantified using the Nonunion Risk Determination (NURD) score. Radiological healing was assessed until 24 weeks or clinical union. Low-dose CT scans were acquired at 12 weeks and virtual mechanical testing was performed to objectively assess structural bone healing.Aims
Methods
The effect of pelvic tilt (PT) and sagittal balance in hips with pincer-type femoroacetabular impingement (FAI) with acetabular retroversion (AR) is controversial. It is unclear if patients with AR have a rotational abnormality of the iliac wing. Therefore, we asked: are parameters for sagittal balance, and is rotation of the iliac wing, different in patients with AR compared to a control group?; and is there a correlation between iliac rotation and acetabular version? A retrospective, review board-approved, controlled study was performed including 120 hips in 86 consecutive patients with symptomatic FAI or hip dysplasia. Pelvic CT scans were reviewed to calculate parameters for sagittal balance (pelvic incidence (PI), PT, and sacral slope), anterior pelvic plane angle, pelvic inclination, and external rotation of the iliac wing and were compared to a control group (48 hips). The 120 hips were allocated to the following groups: AR (41 hips), hip dysplasia (47 hips) and cam FAI with normal acetabular morphology (32 hips). Subgroups of total AR (15 hips) and high acetabular anteversion (20 hips) were analyzed. Statistical analysis was performed using analysis of variance with Bonferroni correction.Aims
Methods
The aim of this study was to determine the impact of hospital-level service characteristics on hip fracture outcomes and quality of care processes measures. This was a retrospective analysis of publicly available audit data obtained from the National Hip Fracture Database (NHFD) 2018 benchmark summary and Facilities Survey. Data extraction was performed using a dedicated proforma to identify relevant hospital-level care process and outcome variables for inclusion. The primary outcome measure was adjusted 30-day mortality rate. A random forest-based multivariate imputation by chained equation (MICE) algorithm was used for missing value imputation. Univariable analysis for each hospital level factor was performed using a combination of Tobit regression, Siegal non-parametric linear regression, and Mann-Whitney U test analyses, dependent on the data type. In all analyses, a p-value < 0.05 denoted statistical significance.Aims
Methods
Knee arthroplasty surgery is a highly effective treatment for arthritis and disorders of the knee. There are a wide variety of implant brands and types of knee arthroplasty available to surgeons. As a result of a number of highly publicized failures, arthroplasty surgery is highly regulated in the UK and many other countries through national registries, introduced to monitor implant performance, surgeons, and hospitals. With time, the options available within many brand portfolios have grown, with alternative tibial or femoral components, tibial insert materials, or shapes and patella resurfacings. In this study we have investigated the effect of the expansion of implant brand portfolios and where there may be a lack of transparency around a brand name. We also aimed to establish the potential numbers of compatible implant construct combinations. Hypothetical implant brand portfolios were proposed, and the number of compatible implant construct combinations was calculated.Aims
Methods
We aimed to evaluate the long-term outcome of highly cross-linked polyethylene (HXLPE) cemented acetabular components and assess whether any radiolucent lines (RLLs) which arose were progressive. We retrospectively reviewed 170 patients who underwent 187 total hip arthroplasties at two hospitals with a minimum follow-up of ten years. All interventions were performed using the same combination of HXLPE cemented acetabular components with femoral stems made of titanium alloy. Kaplan-Meier survival analysis was performed for the primary endpoint of acetabular component revision surgery for any reason and secondary endpoint of the appearance of RLLs. RLLs that had appeared once were observed over time. We statistically assessed potential relationships between RLLs and a number of factors, including the technique of femoral head autografting and the Japanese Orthopaedic Association score.Aims
Methods
Proximal femoral endoprosthetic replacements (PFEPRs) are the most common reconstruction option for osseous defects following primary and metastatic tumour resection. This study aimed to compare the rate of implant failure between PFEPRs with monopolar and bipolar hemiarthroplasties and acetabular arthroplasties, and determine the optimum articulation for revision PFEPRs. This is a retrospective review of 233 patients who underwent PFEPR. The mean age was 54.7 years (SD 18.2), and 99 (42.5%) were male. There were 90 patients with primary bone tumours (38.6%), 122 with metastatic bone disease (52.4%), and 21 with haematological malignancy (9.0%). A total of 128 patients had monopolar (54.9%), 74 had bipolar hemiarthroplasty heads (31.8%), and 31 underwent acetabular arthroplasty (13.3%).Aims
Methods