Advertisement for orthosearch.org.uk
Results 1461 - 1480 of 5421
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 1 | Pages 149 - 149
1 Jan 2003
PARVIZI J


The Bone & Joint Journal
Vol. 104-B, Issue 7 | Pages 852 - 858
1 Jul 2022
Grothe T Günther K Hartmann A Blum S Haselhoff R Goronzy J

Aims. Head-taper corrosion is a cause of failure in total hip arthroplasty (THA). Recent reports have described an increasing number of V40 taper failures with adverse local tissue reaction (ALTR). However, the real incidence of V40 taper damage and its cause remain unknown. The aim of this study was to evaluate the long-term incidence of ALTR in a consecutive series of THAs using a V40 taper and identify potentially related factors. Methods. Between January 2006 and June 2007, a total of 121 patients underwent THA using either an uncemented (Accolade I, made of Ti. 12. Mo. 6. Zr. 2. Fe; Stryker, USA) or a cemented (ABG II, made of cobalt-chrome-molybdenum (CoCrMo); Stryker) femoral component, both with a V40 taper (Stryker). Uncemented acetabular components (Trident; Stryker) with crosslinked polyethylene liners and CoCr femoral heads of 36 mm diameter were used in all patients. At a mean folllow-up of 10.8 years (SD 1.1), 94 patients (79%) were eligible for follow-up (six patients had already undergone a revision, 15 had died, and six were lost to follow-up). A total of 85 THAs in 80 patients (mean age 61 years (24 to 75); 47 (56%) were female) underwent clinical and radiological evaluation, including the measurement of whole blood levels of cobalt and chrome. Metal artifact reduction sequence MRI scans of the hip were performed in 71 patients. Results. A total of 20 ALTRs were identified on MRI, with an incidence of 26%. Patients with ALTR had significantly higher median Co levels compared with those without ALTR (2.96 μg/l (interquartile range (IQR) 1.35 to 4.98) vs 1.44 μg/l (IQR 0.79 to 2.5); p = 0.019). Radiological evidence of osteolysis was also significantly associated with ALTR (p = 0.014). Median Cr levels were not significantly higher in those with ALTR compared with those without one (0.97 μg/l (IQR 0.72 to 1.9) v 0.67 μg/l (IQR 0.5 to 1.19; p = 0.080). BMI, sex, age, type of femoral component, head length, the inclination of the acetabular component, and heterotopic ossification formation showed no significant relationship with ALTR. Conclusion. Due to the high incidence of local ALTR in our cohort after more than ten years postoperatively, we recommend regular follow-up investigation even in asymptomatic patients with V40 taper and metal heads. As cobalt levels correlate with ALTR occurrence, routine metal ion screening and consecutive MRI investigation upon elevation could be discussed. Cite this article: Bone Joint J 2022;104-B(7):852–858


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 3 | Pages 414 - 418
1 Apr 2001
Clark DI Ahmed AB Baxendale BR Moran CG

In a prospective, controlled study, we measured the effect on cardiac output of the introduction of methylmethacrylate during hemiarthroplasty for displaced fractures of the femoral neck. We treated 20 elderly patients who were similar in age, height, weight and preoperative left ventricular function with either cemented or uncemented hemiarthroplasty. Using a transoesophageal Doppler probe, we measured cardiac output before incision and at six stages of the procedure: during the surgical approach, reaming and lavage of the femoral canal, the introduction of cement, the insertion of the prosthesis, and in reduction and closure.

We found that before the cement was introduced, there was no difference in stroke volume or cardiac output (p > 0.25). Cementation produced a transient but significant reduction in cardiac output of 33% (p < 0.01) and a reduction in stroke volume of 44% (p < 0.02). The introduction of cement did not affect the heart rate or mean arterial pressure. There was no significant difference in cardiac function on insertion of the prosthesis. Standard non-invasive haemodynamic monitoring did not detect the cardiovascular changes which may account for the sudden deaths that sometimes occur during cemented hemiarthroplasty.

The fall in stroke volume and cardiac output may be caused by embolism occurring during cementation, but there was no similar fall during reaming or insertion of the prosthesis.


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 1 | Pages 153 - 153
1 Jan 2001
Evans S


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 2 | Pages 240 - 241
1 Feb 2007
Lamdan R Sadun A Shamir MY

We describe a near-fatal event, probably due to air embolism, following an air arthrogram for developmental hip dysplasia in a baby aged four months. The sequence of events and the subsequent treatment are described. There is little information about this complication in the literature. The presumed mechanism and alternative methods for confirmation of placement of the needle are discussed. We no longer use air arthrography in children.


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 3 | Pages 427 - 430
1 May 1999
Wroblewski BM Fleming PA Siney PD

We reviewed 261 patients with 320 Charnley low-friction arthroplasties who had a mean follow-up of 22 years 10 months (20 to 30). Of these, 93.9% considered the operation to be a success; 82.3% were free from pain and 11.6% had occasional discomfort. Satisfactory function was achieved in 59.6% and 62% had an excellent range of movement.

The clinical results did not correlate well with the radiological appearance; radiologically loose components did not affect the clinical outcome. The main long-term problem was wear and loosening of the UHMWPE cup. Our findings suggest that the radiological appearance of the arthroplasty is a more reliable indication of the state of the arthroplasty than the clinical results.


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 2 | Pages 374 - 374
1 Mar 1999
Moore FH


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 1 | Pages 179 - 179
1 Jan 1999
COHEN J


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 6 | Pages 1085 - 1085
1 Nov 1998
Laurence M


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 7 | Pages 833 - 838
1 Jul 2008
Uçkay I Pittet D Bernard L Lew D Perrier A Peter R

More than a million hip replacements are carried out each year worldwide, and the number of other artificial joints inserted is also rising, so that infections associated with arthroplasties have become more common. However, there is a paucity of literature on infections due to haematogenous seeding following dental procedures. We reviewed the published literature to establish the current knowledge on this problem and to determine the evidence for routine antibiotic prophylaxis prior to a dental procedure.

We found that antimicrobial prophylaxis before dental interventions in patients with artificial joints lacks evidence-based information and thus cannot be universally recommended.


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 1 | Pages 181 - 181
1 Jan 1998
BENSON MKD


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 6 | Pages 838 - 838
1 Jun 2006
SPENCER RF


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 6 | Pages 839 - 839
1 Jun 2006
ROBERTS P GRIGORIS P


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 6 | Pages 1041 - 1041
1 Nov 1997
MAQUET P


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 4 | Pages 702 - 702
1 Jul 1997
Walsh HPJ


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 4 | Pages 701 - 702
1 Jul 1997
Muirhead-Allwood S


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 2 | Pages 343 - 343
1 Mar 1997
KOHLER R


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 1 | Pages 85 - 91
1 Jan 1996
Önsten I Carlsson ÅS Sanzén L Besjakov J

A consecutive series of 30 total hip replacements using a hydroxyapatite (HA)-coated, modular implant (Omnifit) was followed clinically and by roentgen stereophotogrammetric analysis for two years and compared with two control groups, one of 27 cemented Charnley sockets and one of 40 cemented Charnley stems.

Omnifit sockets with a central gap between the dome of the socket and the acetabular bone in the postoperative radiographs, migrated less than sockets without such gaps (p = 0.01). After adjustment for patient-related factors (age, gender and weight), no significant difference was found between the two prostheses with respect to micromotion and wear.

We conclude that the early fixation of the HA-coated Omnifit prosthesis compares with that of the cemented Charnley prosthesis.


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 4 | Pages 515 - 516
1 Jul 1994
Catterall A


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 1 | Pages 93 - 100
1 Jan 1992
Liebergall M Lowe J Whitelaw G Wetzler M Segal D

A consecutive series is reported of 17 patients who underwent early surgical treatment for acetabular or unstable pelvic fractures associated with ipsilateral fractures of the femur. Treatment included external and internal fixation, and required careful consideration of the surgical approach and the positioning of the patient. The multiple injuries sustained by these patients required simultaneous procedures by several surgical teams. All the femoral fractures were internally fixed at the initial operation and eight patients had primary definitive treatment of all their other fractures as well. In nine patients the definitive treatment of their other fractures was delayed for an average of 11 days. There were no deaths, and no serious infections. The long-term morbidity resulted from the associated injuries and not from the pelvic or femoral fractures.