Advertisement for orthosearch.org.uk
Results 1421 - 1440 of 2489
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 66-B, Issue 2 | Pages 243 - 247
1 Mar 1984
Lowe L Miller A Allum R Higginson D

This paper describes the development, operative technique and results of an unconstrained total elbow arthroplasty. Forty-seven elbow replacements were carried out in 44 patients between 1974 and 1982. There was a high rate of loosening in the early condylar replacements. The results in patients with post-traumatic arthritis were poor. The later design employs an ulnar stem, with a humeral stem if the distal humeral bone stock is poor. When used in carefully selected patients with rheumatoid arthritis, pain is reduced significantly, stability and movement are preserved and function is improved


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 6 | Pages 802 - 808
1 Aug 2003
Hamilton H Fung T Rapley P

We analysed one surgeon’s attempt to reconstruct the hip in 66 patients (84 hips) with chronic dislocation and to restore the height of the centre of rotation above the transverse teardrop line, the bodyweight lever arm, the abductor lever arm, and the abductor angle to normal. The outcome was assessed using a patient profile at 0, 10 and 20 years, a clinical assessment of pain, mobility and the range of active movement. We measured the work done by active movement against gravity, radiological signs of loosening, migration and subsidence, and the need for revision. We used survival at ten years and revision as the endpoint. The incidence of complications was higher than in arthroplasty for primary osteoarthritis of the hip, but the outcome was considered satisfactory. The advantages of a flanged cemented socket were demonstrated. A custom-made, laterally reduced, Charnley extra small CDH femoral prosthesis was used in certain cases


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 5 | Pages 724 - 728
1 Sep 1991
Hardinge K Porter M Jones P Hukins D Taylor C

A computer-based image analysis system has been developed as a research tool in total hip replacement. The system has been programmed to take multiple measurements from coronal plane radiographs. Poor quality radiographic images can be enhanced and standardised. The measurements which can be obtained include stem subsidence, cup migration, cup wear, and stem loosening. Reproducibility and accuracy were +/- 0.01 mm and +/- 0.5 mm respectively. The present application is in retrospective research, but prospective monitoring of radiographs is planned


Bone & Joint Research
Vol. 6, Issue 8 | Pages 522 - 529
1 Aug 2017
Ali AM Newman SDS Hooper PA Davies CM Cobb JP

Objectives

Unicompartmental knee arthroplasty (UKA) is a demanding procedure, with tibial component subsidence or pain from high tibial strain being potential causes of revision. The optimal position in terms of load transfer has not been documented for lateral UKA. Our aim was to determine the effect of tibial component position on proximal tibial strain.

Methods

A total of 16 composite tibias were implanted with an Oxford Domed Lateral Partial Knee implant using cutting guides to define tibial slope and resection depth. Four implant positions were assessed: standard (5° posterior slope); 10° posterior slope; 5° reverse tibial slope; and 4 mm increased tibial resection. Using an electrodynamic axial-torsional materials testing machine (Instron 5565), a compressive load of 1.5 kN was applied at 60 N/s on a meniscal bearing via a matching femoral component. Tibial strain beneath the implant was measured using a calibrated Digital Image Correlation system.


Bone & Joint Research
Vol. 7, Issue 1 | Pages 85 - 93
1 Jan 2018
Saleh A George J Faour M Klika AK Higuera CA

Objectives

The diagnosis of periprosthetic joint infection (PJI) is difficult and requires a battery of tests and clinical findings. The purpose of this review is to summarize all current evidence for common and new serum biomarkers utilized in the diagnosis of PJI.

Methods

We searched two literature databases, using terms that encompass all hip and knee arthroplasty procedures, as well as PJI and statistical terms reflecting diagnostic parameters. The findings are summarized as a narrative review.


Objectives

Secondary fracture healing is strongly influenced by the stiffness of the bone-fixator system. Biomechanical tests are extensively used to investigate stiffness and strength of fixation devices. The stiffness values reported in the literature for locked plating, however, vary by three orders of magnitude. The aim of this study was to examine the influence that the method of restraint and load application has on the stiffness produced, the strain distribution within the bone, and the stresses in the implant for locking plate constructs.

Methods

Synthetic composite bones were used to evaluate experimentally the influence of four different methods of loading and restraining specimens, all used in recent previous studies. Two plate types and three screw arrangements were also evaluated for each loading scenario. Computational models were also developed and validated using the experimental tests.


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 4 | Pages 603 - 608
1 Jul 1997
Massoud SN Hunter JB Holdsworth BJ Wallace WA Juliusson R

We have studied aseptic loosening of the femoral component in 76 patients with primary total hip replacement using the Capital prosthesis. The mean follow-up was 26 months (10 to 37). Twelve femoral components (16%) were definitely and eight (10%) were possibly loose. They were characterised by a thin cement mantle (p < 0.001) and excessive residual cancellous bone in the proximomedial region (p < 0.01). We recommend that the cement mantle around the prosthesis should be 2 to 3 mm and that further long-term studies are needed to evaluate the wear properties of titanium-nitride-coated titanium femoral heads


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 1 | Pages 85 - 88
1 Jan 1988
Barbos M

Three madreporic prostheses in two patients were examined to evaluate resorption and formation of the surrounding bone tissue. All three prostheses were firmly fixed and had no clinical or radiographic signs of loosening. Transverse sections were examined by scanning electron microscopy at 40 days, 11 months and 2.5 years after implantation. The findings suggest that adaptive bone remodelling varies along the length of the stem; that bone resorption and formation are related to the time after implant; and that new bone formation (woven bone) can be found very close to the madreporic surface


The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 5 | Pages 723 - 726
1 Nov 1987
Kelly I Foster R Fisher W

Forty-two shoulders in 37 patients with polyarthritis were treated with Neer total shoulder replacements and reviewed 12 to 66 months afterwards. There was good pain relief and improvement in function, but the range of movement was less than that seen after replacements for osteoarthritis; this may have been related to the fact that 34 shoulders had abnormal rotator cuff tendons. Although there was a high incidence of radiolucent lines around the glenoid component, there was no clinical evidence of loosening. There were a few complications, but on the whole we feel that the Neer total shoulder arthroplasty is a valuable procedure for a patient with polyarthritis


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 2 | Pages 172 - 176
1 Mar 2004
Glyn-Jones S Gill HS McLardy-Smith P Murray DW

The Birmingham hip resurfacing (BHR) arthroplasty is a metal-on-metal prosthesis for which no medium- or long-term results have been published. Despite this, it is increasing in popularity as an alternative to stemmed prostheses for younger patients. Since the fixation of the socket is conventional, the major concern is long-term failure of the femoral component. This can be predicted by the use of roentgen stereophotogrammetric analysis (RSA). We have therefore undertaken such a study of the BHR femoral component over a period of two years. Twenty patients (22 hips) underwent a standard BHR procedure. Migration of the femoral component was measured by RSA at intervals of three, six, 12 and 24 months. At 24 months the total three-dimensional migration of the head was 0.2 mm. This was not statistically significant. Previous studies have shown that implants which loosen quickly have rapid early migration. Our results therefore suggest that the BHR femoral component is an inherently stable device which is likely to perform well in the long term


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 8 | Pages 1156 - 1161
1 Nov 2000
Rafiq M Worthington T Tebbs SE Treacy RBC Dias R Lambert PA Elliott TSJ

Coagulase-negative staphylococci produce an exocellular glycolipid antigen which has potential as a serological marker of infection in bone. The value of this newly detected antigen was investigated by enzyme-linked immunosorbent assay (ELISA) in 15 patients with culture-proven infection of prostheses caused by Gram-positive bacteria. The antigen was purified by gel-permeation chromatography from the culture supernatants of coagulase-negative staphylococci grown in a chemically defined medium. There were significant differences (p < 0.0001) between the serum IgG and IgM levels in patients with infection due to Gram-positive staphylococci and those of a control group of 32 patients with no infection. The ELISA test, which has potential for the diagnosis of infection, may be valuable in distinguishing between staphylococcal infection around prostheses and aseptic loosening


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 6 | Pages 825 - 831
1 Aug 2001
Adalberth G Nilsson KG Byström S Kolstad K Milbrink J

We studied the quality of fixation of the tibial component using radiostereometric analysis (RSA) in 40 patients who had undergone a cemented Freeman-Samuelson total knee arthroplasty. They were prospectively randomised to either a stemmed metal-backed (MB) or non-stemmed all-polyethylene (AP) tibial component. The articulating geometry of the implants was identical, as was the operative technique and the postoperative regime. The study showed no complications of fixation using AP tibial components, and the migration was the same as that of their metal-backed counterparts. There was no bony collapse or increased subsidence of any part of the tibial component or increased incidence of radiolucent lines in the knees with AP components. Most AP implants were stable between one and two years after surgery, a finding known to be of positive prognostic significance when predicting future aseptic loosening


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 3 | Pages 427 - 430
1 May 1999
Wroblewski BM Fleming PA Siney PD

We reviewed 261 patients with 320 Charnley low-friction arthroplasties who had a mean follow-up of 22 years 10 months (20 to 30). Of these, 93.9% considered the operation to be a success; 82.3% were free from pain and 11.6% had occasional discomfort. Satisfactory function was achieved in 59.6% and 62% had an excellent range of movement. The clinical results did not correlate well with the radiological appearance; radiologically loose components did not affect the clinical outcome. The main long-term problem was wear and loosening of the UHMWPE cup. Our findings suggest that the radiological appearance of the arthroplasty is a more reliable indication of the state of the arthroplasty than the clinical results


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 8 | Pages 1156 - 1160
1 Nov 2001
Donati D Zavatta M Gozzi E Giacomini S Campanacci L Mercuri M

We describe 25 patients who were treated for a tumour of the proximal femur by resection and replacement with an uncemented, bipolar, modular prosthesis. When followed up after more than ten years four prostheses (16%) had required revision. Two joints showed wear and another necrosis of the acetabulum. One patient with loosening of the stem had been treated by radiotherapy to the femur. Articular cartilage seemed to be a reliable barrier to acetabular wear. Very few signs of the formation of particulate debris were observed. The most obvious feature in the bone-stem relationship was stress shielding, seen as osteoporosis of the proximal part of the femur around the stem in 68%. Functional activity was satisfactory in 68% of the patients. A better system of reattachment of the soft tissues is needed to avoid pain and a persistent limp


The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 3 | Pages 456 - 459
1 May 1989
Radford P Doran A Greatorex R Rushton N

Osteonecrosis of the femoral head is a severely disabling complication of steroid immunosuppression in renal transplant patients. We report 31 total hip arthroplasties in 21 renal transplant recipients with an average follow-up of six years. There were no problems with wound healing or infection despite full immunosuppression. Four hips developed symptomatic loosening but the other results were excellent, comparing well with other methods of treatment for osteonecrosis. Ten patients died during the follow-up period. Total hip replacement is a safe and effective treatment for transplant recipients and, in view of their limited life expectancy, should be considered at an early stage in their treatment


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 5 | Pages 750 - 755
1 Nov 1988
Phillips T Messieh S

We have analysed the clinical results of a cementless hip replacement using a Moore stem with a smooth surface, and correlated these results with the radiological changes. Forty-two consecutive arthroplasties in 41 patients were studied prospectively and reviewed at a minimum of two and up to six years; 63% had a good clinical result, 18.5% a fair result, and 18.5% a poor result. Thigh pain on weight-bearing was the main problem and was due to loosening of the stem. We caution against the use of this implant in arthritic patients, in whom a good result can be obtained more predictably with cement fixation


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 4 | Pages 639 - 643
1 Aug 1988
Greenough C Jones

The results of primary total hip arthroplasty for sub-capital femoral neck fracture in previously normal hips are reported. Thirty-seven patients aged 70 or less at the time of surgery were reviewed at an average follow-up of 56 months. Eighteen (49%) had undergone or were awaiting revision surgery. A further four (11%) had definite radiological signs of loosening. Harris hip scores were calculated and correlated well with the results of gait analysis; these suggested that it was the more vigorous patients that were more liable to early failure. Consequently, primary total hip replacement is not recommended for subcapital fractures in the younger patient without pre-existing hip pathology


The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 1 | Pages 61 - 63
1 Jan 1987
Wroblewski B Lynch M Atkinson Dowson D Isaac G

We examined 59 cemented high density polyethylene sockets removed at revision hip arthroplasty. Of these 19 showed areas of wear between the outside of the socket and the acetabular bone. This was associated with lack of acrylic cement in those areas and was also related to the depth of the wear on the articulating surface of the socket. It is suggested that, in some cases, changes at the bone-cement junction are secondary to socket loosening and abrasion against the bone of the acetabulum, rather than to particles migrating from the metal-polyethylene interface. It is therefore important that impingement of the neck of the femoral stem on the edge of the cup be avoided and that, when the socket is inserted, it is not in direct contact with the bone


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 8 | Pages 1126 - 1130
1 Nov 2002
Ashraf T Newman JH Evans RL Ackroyd CE

We describe 88 knees (79 patients) with lateral unicompartmental osteoarthritis which had been treated by the St Georg Sled prosthesis. At a mean follow-up of nine years (2 to 21) 15 knees had revision surgery, nine for progression of arthritis, six for loosening, four for breakage of a component and four for more than one reason. Six patients complained of moderate or severe pain at the final follow-up. Only five knees were lost to follow-up in the 21-year period. We performed survivorship analysis on the group using revision for any cause as the endpoint. At ten years the cumulative survival rate was 83%, and at 15 years, when ten knees were still at risk, it was 74%. Based on our clinical results and survival rate the St Georg Sled may be considered to be a suitable unicompartmental replacement for isolated lateral compartment osteoarthritis


The Journal of Bone & Joint Surgery British Volume
Vol. 66-B, Issue 5 | Pages 682 - 684
1 Nov 1984
Inglis G

A retrospective review of medial compartment arthroplasty in 22 patients (22 knees) is reported. The operations were performed between 1973 and 1978. Eighty-six per cent were rated good or excellent using the knee rating system devised by the Hospital for Special Surgery, New York. Excellent or good results were achieved in six patients who had previously had a high tibial osteotomy. At the time of follow-up significant loosening had not occurred, although progression of patellofemoral disease was noted. This study supports the promising results reported for unicompartmental resurfacing arthroplasty in the elderly