Bone allografts can store and release high levels of vancomycin. We present our results of a two-stage treatment for infected hip arthroplasty with acetabular and femoral impaction grafting using vancomycin-loaded allografts. We treated 29 patients (30 hips) by removal of the implants, meticulous debridement, parenteral antibiotic therapy and second-stage reconstruction using vancomycin-supplemented impacted bone allografts and a standard cemented Charnley femoral component. The mean follow-up was 32.4 months (24 to 60). Infection control was obtained in 29 cases (re-infection rate of 3.3%; 95% confidence interval 0.08 to 17) without evidence of progressive radiolucent lines, demarcation or graft resorption. One patient had a further infection ten months after revision caused by a different pathogen. Associated post-operative complications were one traumatic periprosthetic fracture at 14 months, a single dislocation in two hips and four displacements of the greater trochanter. Vancomycin-supplemented allografts restored bone stock and provided sound fixation with a low incidence of further infection.
The treatment of fractures of the proximal tibia is complex and makes great demands on the implants used. Our study aimed to identify what levels of primary stability could be achieved with various forms of osteosynthesis in the treatment of diaphyseal fractures of the proximal tibia. Pairs of human tibiae were investigated. An unstable fracture was simulated by creating a defect at the metaphyseal-diaphyseal junction. Six implants were tested in a uniaxial testing device (Instron) using the quasi-static and displacement-controlled modes and the force-displacement curve was recorded. The movements of each fragment and of the implant were recorded video-optically (MacReflex, Qualysis). Axial deviations were evaluated at 300 N. The results show that the nailing systems tolerated the highest forces. The lowest axial deviations in varus and valgus were also found for the nailing systems; the highest axial deviations were recorded for the buttress plate and the less invasive stabilising system (LISS). In terms of rotational displacement the LISS was better than the buttress plate. In summary, it was found that higher loads were better tolerated by centrally placed load carriers than by eccentrically placed ones. In the case of the latter, it appears advantageous to use additive procedures for medial buttressing in the early phase.
Iontophoresis is a novel technique which may be used to facilitate the movement of antibiotics into the substance of bone using an electrical potential applied externally. We have examined the rate of early infection in allografts following application of this technique in clinical practice. A total of 31 patients undergoing revision arthroplasty or surgery for limb salvage received 34 iontophoresed sequential allografts, of which 26 survived for a minimum of two years. The mean serum antibiotic levels after operation were low (gentamicin 0.37 mg/l (0.2 to 0.5); flucloxacillin 1 mg/l (0 to 1) and the levels in the drains were high (gentamicin 40 mg/l (2.5 to 131); flucloxacillin 17 mg/l (1 to 43). There were no early deep infections. Two late infections were presumed to be haemotogenous; 28 of the 34 allografts were retained. In 12 patients with pre-existing proven infection further infection has not occurred at a mean follow-up of 51 months (24 to 82).
We have evaluated the functional, clinical and radiological outcome of patients with simple and complex acetabular fractures involving the posterior wall, and identified factors associated with an adverse outcome. We reviewed 128 patients treated operatively for a fracture involving the posterior wall of the acetabulum between 1982 and 1999. The Musculoskeletal Functional Assessment and Short-Form 36 scores, the presence of radiological arthritis and complications were assessed as a function of injury, treatment and clinical variables. The patients had profound functional deficits compared with the normal population. Anatomical reduction alone was not sufficient to restore function. The fracture pattern, marginal impaction and residual displacement of >
2 mm were associated with the development of arthritis, which related to poor function and the need for hip replacement. It may be appropriate to consider immediate total hip replacement for patients aged >
50 years with marginal impaction and comminution of the wall, since 7 of 13 (54%) of these required early hip replacement.
We describe the intermediate results of lateral ligamentous repair or reconstruction for posterolateral rotatory instability of the elbow. Between 1986 and 1999, we performed 12 direct repairs and 33 ligament reconstructions with a tendon autograft. One patient was lost to follow-up and 44 were retrospectively studied at a mean of six years (2 to 15). Surgery restored stability in all except five patients. In two the elbow became stable after a second procedure. The mean post-operative Mayo elbow performance score was 85 points (60 to 100). The result was classified as excellent in 19, good in 13, fair in seven and poor in five patients. Thirty-eight patients (86%) were subjectively satisfied with the outcome of the operation. Better results were obtained in patients with a post-traumatic aetiology (p = 0.03), those with subjective symptoms of instability at presentation (p = 0.006) and those who had an augmented reconstruction using a tendon graft (p = 0.04). Reconstruction using a tendon graft seems to provide better results than ligament repair and the results do not seem to deteriorate with time. The outcome of this procedure is less predictable in patients with no subjective instability.
Over the past 40 years, the management of displaced fractures of the acetabulum has changed from conservative to operative. We have undertaken a meta-analysis to evaluate the classification, the incidence of complications and the functional outcome of patients who had undergone operative treatment of such injuries. We analysed a total of 3670 fractures. The most common long-term complication was osteoarthritis which occurred in approximately 20% of the patients. Other late complications, including heterotopic ossification and avascular necrosis of the femoral head, were present in less than 10%. However, only 8% of patients who were treated surgically needed a further operation, usually a hip arthroplasty, and between 75% and 80% of patients gained an excellent or good result at a mean of five years after injury. Factors influencing the functional outcome included the type of fracture and/or dislocation, damage to the femoral head, associated injuries and co-morbidity which can be considered to be non-controllable, and the timing of the operation, the surgical approach, the quality of reduction and local complications which are all controllable. The treatment of these injuries is challenging. Tertiary referrals need to be undertaken as early as possible, since the timing of surgery is of the utmost importance. It is important, at operation, to obtain the most accurate reduction of the fracture which is possible, with a minimal surgical approach, as both are related to improved outcome.