Advertisement for orthosearch.org.uk
Results 1401 - 1420 of 1897
Results per page:
Bone & Joint 360
Vol. 2, Issue 4 | Pages 12 - 15
1 Aug 2013

The August 2013 Foot & Ankle Roundup360 looks at: mobility, ankles and fractures; hindfoot nailing: not such a bad option after all?; little treatment benefit for blood injection in tendonitis; fixed bearing ankles successful in the short term; hindfoot motion following STAR ankle replacement; minimally invasive calcaneal fracture fixation?; pes planus in adolescents; and subluxing peroneals and groove deepening


Bone & Joint 360
Vol. 3, Issue 3 | Pages 2 - 8
1 Jun 2014
Phillips JRA Waterson HB Searle DJ Mandalia VI Toms AD

This is the second of a series of reviews of registries. This review looks specifically at worldwide registry data that have been collected on knee arthroplasty, what we have learned from their reports, and what the limitations are as to what we currently know.


Bone & Joint 360
Vol. 3, Issue 6 | Pages 21 - 23
1 Dec 2014

The December 2014 Spine Roundup360 looks at: surgeon outcomes;

complications and scoliosis surgery; is sequestrectomy enough in lumbar disc prolapse?; predicting outcomes in lumbar disc herniation; sympathectomy has a direct effect on the dorsal root ganglion; and distal extensions of fusion in adolescent idiopathic scoliosis.


Bone & Joint 360
Vol. 3, Issue 1 | Pages 35 - 37
1 Feb 2014

The February 2014 Children’s orthopaedics Roundup360 looks at: flexible plasters; dual 8-plate or ablation for knee epiphysiodesis; ultrasounds for pulled elbow; leg length without the radiation; Boyd amputation in limb deficiencies; gold standard club foot treatment; quadrupled semitendinosis graft effective in paediatric ACL reconstruction; and predicting complications following cerebral palsy hip reconstruction


Bone & Joint 360
Vol. 3, Issue 6 | Pages 19 - 21
1 Dec 2014

The December 2014 Shoulder & Elbow Roundup360 looks at: cuff tears and plexus injury;

corticosteroids and physiotherapy in SAI; diabetes and elbow arthroplasty; distal biceps tendon repairs; shockwave therapy in frozen shoulder; hydrodilation and steroids for adhesive capsulitis; just what do our patients read?; and what happens to that stable radial head fracture?


The Bone & Joint Journal
Vol. 97-B, Issue 1 | Pages 94 - 99
1 Jan 2015
Grammatopoulos G Wilson HA Kendrick BJL Pulford EC Lippett J Deakin M Andrade AJ Kambouroglou G

National Institute of Clinical Excellence guidelines state that cemented stems with an Orthopaedic Data Evaluation Panel (ODEP) rating of > 3B should be used for hemiarthroplasty when treating an intracapsular fracture of the femoral neck. These recommendations are based on studies in which most, if not all stems, did not hold such a rating.

This case-control study compared the outcome of hemiarthroplasty using a cemented (Exeter) or uncemented (Corail) femoral stem. These are the two prostheses most commonly used in hip arthroplasty in the UK.

Data were obtained from two centres; most patients had undergone hemiarthroplasty using a cemented Exeter stem (n = 292/412). Patients were matched for all factors that have been shown to influence mortality after an intracapsular fracture of the neck of the femur. Outcome measures included: complications, re-operations and mortality rates at two, seven, 30 and 365 days post-operatively. Comparable outcomes for the two stems were seen.

There were more intra-operative complications in the uncemented group (13% vs 0%), but the cemented group had a greater mortality in the early post-operative period (n = 6). There was no overall difference in the rate of re-operation (5%) or death (365 days: 26%) between the two groups at any time post-operatively.

This study therefore supports the use of both cemented and uncemented stems of proven design, with an ODEP rating of 10A, in patients with an intracapsular fracture of the neck of the femur.

Cite this article: Bone Joint J 2015;97-B:94–9.


The Bone & Joint Journal
Vol. 97-B, Issue 3 | Pages 337 - 345
1 Mar 2015
Jaroma AVJ Soininvaara TA Kröger H

Total knee arthroplasty (TKA) is known to lead to a reduction in periprosthetic bone mineral density (BMD). In theory, this may lead to migration, instability and aseptic loosening of the prosthetic components. Bisphosphonates inhibit bone resorption and may reduce this loss in BMD. We hypothesised that treatment with bisphosphonates and calcium would lead to improved BMD and clinical outcomes compared with treatment with calcium supplementation alone following TKA. A total of 26 patients, (nine male and 17 female, mean age 67 years) were prospectively randomised into two study groups: alendronate and calcium (bisphosphonate group, n = 14) or calcium only (control group, n = 12). Dual energy X-ray absorptiometry (DEXA) measurements were performed post-operatively, and at three months, six months, one, two, four, and seven years post-operatively.

Mean femoral metaphyseal BMD was significantly higher in the bisphosphonate group compared with controls, up to four years following surgery in some areas of the femur (p = 0.045). BMD was observed to increase in the lateral tibial metaphysis in the bisphosphonate group until seven years (p = 0.002), and was significantly higher than that observed in the control group throughout (p = 0.024). There were no significant differences between the groups in the central femoral metaphyseal, tibial medial metaphyseal or diaphyseal regions of interest (ROI) of either the femur or tibia.

Bisphosphonate treatment after TKA may be of benefit for patients with poor bone quality. However, further studies with a larger number of patients are necessary to assess whether this is clinically beneficial.

Cite this article: Bone Joint J 2015;97-B:337–45.


Bone & Joint 360
Vol. 3, Issue 5 | Pages 1 - 1
1 Oct 2014
Ollivere B


The Bone & Joint Journal
Vol. 96-B, Issue 3 | Pages 299 - 305
1 Mar 2014
Bell KR Clement ND Jenkins PJ Keating JF

We performed a case–control study to compare the rates of further surgery, revision and complications, operating time and survival in patients who were treated with either an uncemented hydroxyapatite-coated Corail bipolar femoral stem or a cemented Exeter stem for a displaced intracapsular fracture of the hip. The mean age of the patients in the uncemented group was 82.5 years (53 to 97) and in the cemented group was 82.7 years (51 to 99) We used propensity score matching, adjusting for age, gender and the presence or absence of dementia and comorbidities, to produce a matched cohort receiving an Exeter stem (n = 69) with which to compare the outcome of patients receiving a Corail stem (n = 69). The Corail had a significantly lower all-cause rate of further surgery (p = 0.016; odds ratio (OR) 0.18, 95% CI 0.04 to 0.84) and number of hips undergoing major further surgery (p = 0.029; OR 0.13, 95% CI 0.01 to 1.09). The mean operating time was significantly less for the Corail group than for the cemented Exeter group (59 min [12 to 136] vs 70 min [40 to 175], p = 0.001). The Corail group also had a lower risk of a peri-prosthetic fracture (p = 0.042; OR 0.19, 95% CI 0.01 to 1.42) . There was no difference in the mortality rate between the groups. There were significantly fewer complications in the uncemented group, suggesting that the use of this stem would result in a decreased rate of morbidity in these frail patients. Whether this relates to an improved functional outcome remains unknown.

Cite this article: Bone Joint J 2014;96-B:299–305.


Bone & Joint 360
Vol. 3, Issue 6 | Pages 31 - 34
1 Dec 2014

The December 2014 Research Roundup360 looks at: demineralised bone matrix not as good as we thought?; trunk control following ACL reconstruction; subclinical thyroid dysfunction: not quite subclinical?; establishing musculoskeletal function in mucopolysaccharidosis; starting out: a first year in consultant practice under the spotlight; stroke and elective surgery; sepsis and clots; hip geometry and arthritis incidence; and theatre discipline and infection.


The Bone & Joint Journal
Vol. 96-B, Issue 1 | Pages 132 - 136
1 Jan 2014
Shahid M Saunders T Jeys L Grimer R

We reviewed the outcome of patients who had been treated operatively for symptomatic peri-acetabular metastases and present an algorithm to guide treatment.

The records of 81 patients who had been treated operatively for symptomatic peri-acetabular metastases between 1987 and 2010 were identified. There were 27 men and 54 women with a mean age of 61 years (15 to 87). The diagnosis, size of lesion, degree of pelvic continuity, type of reconstruction, World Health Organization performance status, survival time, pain, mobility and complications including implant failure were recorded in each case.

The overall patient survivorship at five years was 5%. The longest lived patient survived 16 years from the date of diagnosis. The mean survival was 23 months (< 1 to 16 years) and the median was 15 months. At follow-up 14 patients remained alive. Two cementoplasties failed because of local disease progression. Three Harrington rods broke: one patient needed a subsequent Girdlestone procedure. One ‘ice-cream cone’ prosthesis dislocated and was subsequently revised without further problems. We recommend the ‘ice-cream cone’ for pelvic discontinuity and Harrington rod reconstruction for severe bone loss. Smaller defects can be safely managed using standard revision hip techniques.

Cite this article: Bone Joint J 2014;96-B:132–6.


The Bone & Joint Journal
Vol. 96-B, Issue 11_Supple_A | Pages 43 - 47
1 Nov 2014
Su EP Su SL

Surgical interventions consisting of internal fixation (IF) or total hip replacement (THR) are required to restore patient mobility after hip fractures. Conventionally, this decision was based solely upon the degree of fracture displacement. However, in the last ten years, there has been a move to incorporate patient characteristics into the decision making process. Research demonstrating that joint replacement renders superior functional results when compared with IF, in the treatment of displaced femoral neck fractures, has swayed the pendulum in favour of THR. However, a high risk of dislocation has always been the concern. Fortunately, there are newer technologies and alternative surgical approaches that can help reduce the risk of dislocation. The authors propose an algorithm for the treatment of femoral neck fractures: if minimally displaced, in the absence of hip joint arthritis, IF should be performed; if arthritis is present, or the fracture is displaced, then THR is preferred.

Cite this article: Bone Joint J 2014;96-B(11 Suppl A):43–7.


The Bone & Joint Journal
Vol. 97-B, Issue 2 | Pages 164 - 172
1 Feb 2015
Grammatopoulos G Thomas GER Pandit H Beard DJ Gill HS Murray DW

We assessed the orientation of the acetabular component in 1070 primary total hip arthroplasties with hard-on-soft, small diameter bearings, aiming to determine the size and site of the target zone that optimises outcome. Outcome measures included complications, dislocations, revisions and ΔOHS (the difference between the Oxford Hip Scores pre-operatively and five years post-operatively). A wide scatter of orientation was observed (2sd 15°). Placing the component within Lewinnek’s zone was not associated withimproved outcome. Of the different zone sizes tested (± 5°, ± 10° and ± 15°), only ± 15° was associated with a decreased rate of dislocation. The dislocation rate with acetabular components inside an inclination/anteversion zone of 40°/15° ± 15° was four times lower than those outside. The only zone size associated with statistically significant and clinically important improvement in OHS was ± 5°. The best outcomes (ΔOHS > 26) were achieved with a 45°/25° ± 5° zone.

This study demonstrated that with traditional technology surgeons can only reliably achieve a target zone of ±15°. As the optimal zone to diminish the risk of dislocation is also ±15°, surgeons should be able to achieve this. This is the first study to demonstrate that optimal orientation of the acetabular component improves the functional outcome. However, the target zone is small (± 5°) and cannot, with current technology, be consistently achieved.

Cite this article: Bone Joint J 2015;97-B:164–72.


Bone & Joint 360
Vol. 2, Issue 3 | Pages 31 - 33
1 Jun 2013

The June 2013 Trauma Roundup360 looks at: open foot fractures; the diagnostic accuracy of continuous compartment pressure monitoring; conservative treatment for supracondylar fractures; high complication rates in patellar fractures; vitamin D and fracture; better function with K-wires; and tensionless bands.


Bone & Joint 360
Vol. 2, Issue 6 | Pages 14 - 17
1 Dec 2013

The December 2013 Knee Roundup360 looks at: Conflict of interest and hyaluronic acid; Will time indeed tell in microfracture?; Contralateral knee pain and joint replacement outcomes; Patient satisfaction and knee replacement?; Hope in the cytokines for painful TKRs?; Pain severity, cytokines and osteoarthritis?; Quadriceps weakness and pain; and spontaneous osteonecrosis of the knee


Bone & Joint 360
Vol. 3, Issue 5 | Pages 21 - 22
1 Oct 2014

The October 2014 Shoulder & Elbow Roundup360 looks at: PRP is not effective in tennis elbow; eccentric physiotherapy effective in subacromial pain; dexamethasone in shoulder surgery; arthroscopic remplissage for engaging Hill-Sach’s lesions; a consistent approach to subacromial impingement; delay in fixation of proximal humeral fractures detrimental to outcomes.


The Bone & Joint Journal
Vol. 95-B, Issue 12 | Pages 1645 - 1649
1 Dec 2013
Bernhoff K Rudström H Gedeborg R Björck M

Popliteal artery injury (PAI) is a feared complication during knee replacement. Our aim was to investigate those injuries that occurred in association with knee replacement in terms of the type of injury, treatment and outcomes.

From our national vascular registry (Swedvasc) and the Swedish Patient Insurance databases a total of 32 cases were identified. Prospective data from the registries was supplemented with case-records, including long-term follow-up.

We estimated the incidence during 1998 to 2010 to be 0.017%. In our series of 32 patients with PAI occurring between 1987 and 2011, 25 (78%) were due to penetrating trauma and seven were caused by blunt trauma. The patients presented in three ways: bleeding (14), ischaemia (7) and false aneurysm formation (11), and five occurred during revision surgery. A total of 12 injuries were detected intra-operatively, eight within 24 hours (3 to 24) and 12 at more than 24 hours post-operatively (2 to 90 days). Treatment comprised open surgery in 28 patients. Patency of the vascular repair at 30 days was 97% (31 of 32, one amputation). At the time of follow-up (median 546 days, mean 677 days (24 to 1251)), 25 patients had residual symptoms. Of seven patients with a complete recovery, six had had an early diagnosis of the PAI during the procedure, and were treated by a vascular surgeon in the same hospital.

PAI is a rare adverse event during knee replacement surgery. The outcome following such events is often adversely affected by diagnostic and therapeutic delay. Bleeding and false aneurysm were the most common clinical presentations.

Cite this article: Bone Joint J 2013;95-B:1645–9.


The Bone & Joint Journal
Vol. 95-B, Issue 2 | Pages 181 - 187
1 Feb 2013
Liddle AD Pandit H O’Brien S Doran E Penny ID Hooper GJ Burn PJ Dodd CAF Beverland DE Maxwell AR Murray DW

The Cementless Oxford Unicompartmental Knee Replacement (OUKR) was developed to address problems related to cementation, and has been demonstrated in a randomised study to have similar clinical outcomes with fewer radiolucencies than observed with the cemented device. However, before its widespread use it is necessary to clarify contraindications and assess the complications. This requires a larger study than any previously published.

We present a prospective multicentre series of 1000 cementless OUKRs in 881 patients at a minimum follow-up of one year. All patients had radiological assessment aligned to the bone–implant interfaces and clinical scores. Analysis was performed at a mean of 38.2 months (19 to 88) following surgery. A total of 17 patients died (comprising 19 knees (1.9%)), none as a result of surgery; there were no tibial or femoral loosenings. A total of 19 knees (1.9%) had significant implant-related complications or required revision. Implant survival at six years was 97.2%, and there was a partial radiolucency at the bone–implant interface in 72 knees (8.9%), with no complete radiolucencies. There was no significant increase in complication rate compared with cemented fixation (p = 0.87), and no specific contraindications to cementless fixation were identified.

Cementless OUKR appears to be safe and reproducible in patients with end-stage anteromedial osteoarthritis of the knee, with radiological evidence of improved fixation compared with previous reports using cemented fixation.

Cite this article: Bone Joint J 2013;95-B:181–7.


The Bone & Joint Journal
Vol. 96-B, Issue 12 | Pages 1637 - 1643
1 Dec 2014
Yang Z Liu H Xie X Tan Z Qin T Kang P

Total knee replacement (TKR) is an effective method of treating end-stage arthritis of the knee. It is not, however, a procedure without risk due to a number of factors, one of which is diabetes mellitus. The purpose of this study was to estimate the general prevalence of diabetes in patients about to undergo primary TKR and to determine whether diabetes mellitus adversely affects the outcome. We conducted a systematic review and meta-analysis according to the Meta-analysis Of Observational Studies in Epidemiology (MOOSE) guidelines. The Odds Ratio (OR) and mean difference (MD) were used to represent the estimate of risk of a specific outcome. Our results showed the prevalence of diabetes mellitus among patients undergoing TKR was 12.2%. Patients with diabetes mellitus had an increased risk of deep infection (OR = 1.61, 95% confidence interval (CI), 1.38 to 1.88), deep vein thrombosis (in Asia, OR = 2.57, 95% CI, 1.58 to 4.20), periprosthetic fracture (OR = 1.89, 95% CI, 1.04 to 3.45), aseptic loosening (OR = 9.36, 95% CI, 4.63 to 18.90), and a poorer Knee Society function subscore (MD = -5.86, 95% CI, -10.27 to -1.46). Surgeons should advise patients specifically about these increased risks when obtaining informed consent and be meticulous about their peri-operative care.

Cite this article: Bone Joint J 2014;96-B:1637–43.


The Bone & Joint Journal
Vol. 95-B, Issue 11_Supple_A | Pages 77 - 83
1 Nov 2013
Gehrke T Zahar A Kendoff D

Based on the first implementation of mixing antibiotics into bone cement in the 1970s, the Endo-Klinik has used one stage exchange for prosthetic joint infection (PJI) in over 85% of cases. Looking carefully at current literature and guidelines for PJI treatment, there is no clear evidence that a two stage procedure has a higher success rate than a one-stage approach. A cemented one-stage exchange potentially offers certain advantages, mainly based on the need for only one operative procedure, reduced antibiotics and hospitalisation time. In order to fulfill a one-stage approach, there are obligatory pre-, peri- and post-operative details that need to be meticulously respected, and are described in detail. Essential pre-operative diagnostic testing is based on the joint aspiration with an exact identification of any bacteria. The presence of a positive bacterial culture and respective antibiogram are essential, to specify the antibiotics to be loaded to the bone cement, which allows a high local antibiotic elution directly at the surgical side. A specific antibiotic treatment plan is generated by a microbiologist. The surgical success relies on the complete removal of all pre-existing hardware, including cement and restrictors and an aggressive and complete debridement of any infected soft tissues and bone material. Post-operative systemic antibiotic administration is usually completed after only ten to 14 days.

Cite this article: Bone Joint J 2013;95-B, Supple A:77–83.