The AO Foundation advocates the use of partially
threaded lag screws in the fixation of fractures of the medial malleolus.
However, their threads often bypass the radiodense physeal scar
of the distal tibia, possibly failing to obtain more secure purchase
and better compression of the fracture. We therefore hypothesised that the partially threaded screws
commonly used to fix a medial malleolar fracture often provide suboptimal
compression as a result of bypassing the physeal scar, and proposed
that better compression of the fracture may be achieved with shorter
partially threaded screws or fully threaded screws whose threads
engage the physeal scar. We analysed compression at the fracture site in human cadaver
medial malleoli treated with either 30 mm or 45 mm long partially
threaded screws or 45 mm fully threaded screws. The median compression
at the fracture site achieved with 30 mm partially threaded screws
(0.95 kg/cm2 (interquartile range (IQR) 0.8 to 1.2) and
45 mm fully threaded screws
(1.0 kg/cm2 (IQR 0.7 to 2.8)) was significantly higher
than that achieved with 45 mm partially threaded screws (0.6 kg/cm2 (IQR
0.2 to 0.9)) (p = 0.04 and p <
0.001, respectively). The fully
threaded screws and the 30mm partially threaded screws were seen
to engage the physeal scar under an image intensifier in each case. The results support the use of 30 mm partially threaded or 45
mm fully threaded screws that engage the physeal scar rather than
longer partially threaded screws that do not. A
45 mm fully threaded screw may in practice offer additional benefit
over 30 mm partially threaded screws in increasing the thread count
in the denser paraphyseal region. Cite this article:
We assessed the outcome of patients who were
lost to follow-up after arthroplasty by a single surgeon. The aim was
to validate the surgeon’s data set with the Australian Orthopaedic
Association National Joint Replacement Registry and determine the
outcome of those patients lost to follow-up. Prospective data on patient demographics, operative details and
outcomes of the surgeon’s 1192 primary unicompartmental knee arthroplasty
(UKA) procedures were analysed. There were 69 knees in patients
who were lost to follow-up, among whom the Registry identified 31
deaths and eight revisions. The cumulative percentage revision (CPR) at seven years using
the additional Registry data was 8.8% (95% confidence interval (CI)
7 to 11). Using the surgeon’s data, the CPR at seven years was 8%
(95% CI 6.3 to 10.1) for the best-case scenario where loss to follow-up
was excluded, and 16% (95% CI 13.8 to 19.4) for the worst-case scenario, where
all patients lost to follow-up were deemed to have been revised.
There was a significantly higher mortality rate in those patients
lost to follow-up. This study demonstrates that a national joint registry can be
used by individual surgeons to establish more accurate revision
rates in their arthroplasty patients. This is expected to facilitate
a more rigorous audit of surgical outcomes by surgeons and lead
to more accurate and uniform reporting of the results of arthroplasty
in general.
In an initial randomised controlled trial (RCT)
we segregated 180 patients to one of two knee positions following total
knee replacement (TKR): six hours of knee flexion using either a
jig or knee extension. Outcome measures included post-operative
blood loss, fall in haemoglobin, blood transfusion requirements,
knee range of movement, limb swelling and functional scores. A second
RCT consisted of 420 TKR patients randomised to one of three post-operative
knee positions: flexion for three or six hours post-operatively,
or knee extension. Positioning of the knee in flexion for six hours immediately
after surgery significantly reduced blood loss (p = 0.002). There
were no significant differences in post-operative range of movement,
swelling, pain or outcome scores between the various knee positions
in either study. Post-operative knee flexion may offer a simple
and cost-effective way to reduce blood loss and transfusion requirements
following TKR. We also report a cautionary note regarding the potential risks
of prolonged knee flexion for more than six hours observed during
clinical practice in the intervening period between the two trials,
with 14 of 289 patients (4.7%) reporting lower limb sensory neuropathy
at their three-month review. Cite this article:
The December 2012 Hip &
Pelvis Roundup360 looks at: swimming against the tide with resurfacing; hip impingement surgery; the relationship between obesity and co-morbidities and joint replacement infection; cemented hips; cross-linked polyethylene notching; whether cement is necessary in oncological arthroplasty; and how total hip replacement may result in weight gain.
The December 2013 Knee Roundup360 looks at: Conflict of interest and hyaluronic acid; Will time indeed tell in microfracture?; Contralateral knee pain and joint replacement outcomes; Patient satisfaction and knee replacement?; Hope in the cytokines for painful TKRs?; Pain severity, cytokines and osteoarthritis?; Quadriceps weakness and pain; and spontaneous osteonecrosis of the knee
To review the systemic impact of smoking on bone healing as evidenced
within the orthopaedic literature. A protocol was established and studies were sourced from five
electronic databases. Screening, data abstraction and quality assessment
was conducted by two review authors. Prospective and retrospective
clinical studies were included. The primary outcome measures were
based on clinical and/or radiological indicators of bone healing.
This review specifically focused on non-spinal orthopaedic studies.Objectives
Methods
The December 2013 Oncology Roundup360 looks at: Peri-articular resection fraught with complications; Navigated margins; Skeletal tumours and thromboembolism; Conditional survival in Ewing’s sarcoma; Reverse shoulders and tumour; For how long should we follow up sarcoma patients?; and already metastasised?
We reviewed 31 consecutive patients with Friedreich’s
ataxia and scoliosis. There were 24 males and seven females with
a mean age at presentation of 15.5 years (8.6 to 30.8) and a mean
curve of 51° (13° to 140°). A total of 12 patients had thoracic
curvatures, 11 had thoracolumbar and eight had double thoracic/lumbar.
Two patients had long thoracolumbar collapsing scoliosis with pelvic
obliquity and four had hyperkyphosis. Left-sided thoracic curves in
nine patients (45%) and increased thoracic kyphosis differentiated
these deformities from adolescent idiopathic scoliosis. There were
17 patients who underwent a posterior instrumented spinal fusion
at mean age of 13.35 years, which achieved and maintained good correction
of the deformity. Post-operative complications included one death due
to cardiorespiratory failure, one revision to address nonunion and
four patients with proximal junctional kyphosis who did not need
extension of the fusion. There were no neurological complications
and no wound infections. The rate of progression of the scoliosis
in children kept under simple observation and those treated with bracing
was less for lumbar curves during bracing and similar for thoracic
curves. The scoliosis progressed in seven of nine children initially
treated with a brace who later required surgery. Two patients presented
after skeletal maturity with balanced curves not requiring correction.
Three patients with severe deformities who would benefit from corrective
surgery had significant cardiac co-morbidities.
Debate has raged over whether a cruciate retaining
(CR) or a posterior stabilised (PS) total knee replacement (TKR) provides
a better range of movement (ROM) for patients. Various sub-sets
of CR design are frequently lumped together when comparing outcomes.
Additionally, multiple factors have been proven to influence the
rate of manipulation under anaesthetic (MUA) following TKR. The
purpose of this study was to determine whether different CR bearing
insert designs provide better ROM or different MUA rates. All primary
TKRs performed by two surgeons between March 2006 and March 2009
were reviewed and 2449 CR-TKRs were identified. The same CR femoral
component, instrumentation, and tibial base plate were consistently
used. In 1334 TKRs a CR tibial insert with 3° posterior slope and
no posterior lip was used (CR-S). In 803 there was an insert with
no slope and a small posterior lip (CR-L) and in 312 knees the posterior
cruciate ligament (PCL) was either resected or lax and a deep-dish,
anterior stabilised insert was used (CR-AS). More CR-AS inserts
were used in patients with less pre-operative ROM and greater pre-operative
tibiofemoral deformity and flexion contracture (p <
0.05). The
mean improvement in ROM was highest for the CR-AS inserts (5.9°
(-40° to 55°) Cite this article:
The increasing prevalence of osteoporosis in
an ageing population has contributed to older patients becoming
the fastest-growing group presenting with acetabular fractures.
We performed a systematic review of the literature involving a number
of databases to identify studies that included the treatment outcome
of acetabular fractures in patients aged >
55 years. An initial
search identified 61 studies; after exclusion by two independent
reviewers, 15 studies were considered to meet the inclusion criteria.
All were case series. The mean Coleman score for methodological
quality assessment was 37 (25 to 49). There were 415 fractures in
414 patients. Pooled analysis revealed a mean age of 71.8 years
(55 to 96) and a mean follow-up of 47.3 months (1 to 210). In seven
studies the results of open reduction and internal fixation (ORIF)
were presented: this was combined with simultaneous hip replacement
(THR) in four, and one study had a mixture of these strategies.
The results of percutaneous fixation were presented in two studies,
and a single study revealed the results of non-operative treatment. With fixation of the fracture, the overall mean rate of conversion
to THR was 23.1% (0% to 45.5%). The mean rate of non-fatal complications
was 39.8% (0% to 64%), and the mean mortality rate was 19.1% (5%
to 50%) at a mean of 64 months (95% confidence interval 59.4 to
68.6; range 12 to 143). Further data dealing with the classification
of the fracture, the surgical approach used, operative time, blood
loss, functional and radiological outcomes were also analysed. This study highlights that, of the many forms of treatment available
for this group of patients, there is a trend to higher complication
rates and the need for further surgery compared with the results
of the treatment of acetabular fractures in younger patients. Cite this article:
Impaction bone grafting for the reconstitution
of bone stock in revision hip surgery has been used for nearly 30 years.
Between 1995 and 2001 we used this technique in acetabular reconstruction,
in combination with a cemented component, in 304 hips in 292 patients
revised for aseptic loosening. The only additional supports used
were stainless steel meshes placed against the medial wall or laterally
around the acetabular rim to contain the graft. All Paprosky grades
of defect were included. Clinical and radiographic outcomes were
collected in surviving patients at a minimum of ten years after
the index operation. Mean follow-up was 12.4 years ( Cite this article:
Patient specific cutting guides generated by
preoperative Magnetic Resonance Imaging (MRI) of the patient’s extremity
have been proposed as a method of improving the consistency of Total
Knee Arthroplasty (TKA) alignment and adding efficiency to the operative
procedure. The cost of this option was evaluated by quantifying the
savings from decreased operative time and instrument processing
costs compared to the additional cost of the MRI and the guide.
Coronal plane alignment was measured in an unselected consecutive
series of 200 TKAs, 100 with standard instrumentation and 100 with
custom cutting guides. While the cutting guides had significantly lower
total operative time and instrument processing time, the estimated
$322 savings was overwhelmed by the $1,500 additional cost of the
MRI and the cutting guide. All measures of coronal plane alignment
were equivalent between the two groups. The data does not currently
support the proposition that patient specific guides add value to
TKA.
Satisfaction is increasingly employed as an outcome
measure for a successful total knee replacement (TKR). Satisfaction
as an outcome measure encompasses many different intrinsic and extrinsic
factors related to a person’s experience before and after TKR. The
Swedish Knee Arthroplasty Registry has previously demonstrated on
a large population study that 17% of TKR recipients are not satisfied
with their TKR outcome. This finding has been replicated in other
countries. Similar significant factors emerged from these registry
studies that are related to satisfaction. It would appear that satisfaction
is better after more chronic diseases and whether the TKR results
in pain relief or improved function. Importantly, unmet pre-operative
expectations are a significant predictor for dissatisfaction following
a TKR. It may be possible to improve rates by addressing the issues
surrounding pain, function and expectation before embarking on surgery. Cite this article:
Patients with transfemoral amputation (TFA) often
experience problems related to the use of socket-suspended prostheses.
The clinical development of osseointegrated percutaneous prostheses
for patients with a TFA started in 1990, based on the long-term
successful results of osseointegrated dental implants. Between1999 and 2007, 51 patients with 55 TFAs were consecutively
enrolled in a prospective, single-centre non-randomised study and
followed for two years. The indication for amputation was trauma
in 33 patients (65%) and tumour in 12 (24%). A two-stage surgical
procedure was used to introduce a percutaneous implant to which
an external amputation prosthesis was attached. The assessment of
outcome included the use of two self-report questionnaires, the
Questionnaire for Persons with a Transfemoral Amputation (Q-TFA)
and the Short-Form (SF)-36. The cumulative survival at two years’ follow-up was 92%. The
Q-TFA showed improved prosthetic use, mobility, global situation
and fewer problems (all p <
0.001). The physical function SF-36
scores were also improved (p <
0.001). Superficial infection
was the most frequent complication, occurring 41 times in 28 patients
(rate of infection 54.9%). Most were treated effectively with oral
antibiotics. The implant was removed in four patients because of loosening
(three aseptic, one infection). Osseointegrated percutaneous implants constitute a novel form
of treatment for patients with TFA. The high cumulative survival
rate at two years (92%) combined with enhanced prosthetic use and
mobility, fewer problems and improved quality of life, supports
the ‘revolutionary change’ that patients with TFA have reported
following treatment with osseointegrated percutaneous prostheses. Cite this article:
The purpose of this study was to evaluate the
clinical results of a newly designed prosthesis to replace the body
of the talus in patients with aseptic necrosis. Between 1999 and
2006, 22 tali in 22 patients were replaced with a ceramic prosthesis.
A total of eight patients were treated with the first-generation
prosthesis, incorporating a peg to fix into the retained neck and
head of the talus, and the remaining 14 were treated with the second-generation prosthesis,
which does not have the peg. The clinical results were assessed
by the American Orthopaedic Foot and Ankle Society ankle/hindfoot
scale. The mean follow-up was 98 months (18 to 174). The clinical results
of the first-generation prostheses were excellent in three patients,
good in one, fair in three and poor in one. There were, however,
radiological signs of loosening, prompting a change in design. The
clinical results of the second-generation prostheses were excellent
in three patients, good in five, fair in four and poor in two, with
more favourable radiological appearances. Revision was required
using a total talar implant in four patients, two in each group. Although the second-generation prosthesis produced better results,
we cannot recommend the use of a talar body prosthesis. We now recommend
the use of a total talar implant in these patients.
The variation in surgical performance, both between
centres and individual surgeons, has recently been of significant
political, media and public interest. Within the United Kingdom, a
government agenda to increase accountability amongst surgeons has
led to the online publication of ‘surgeon-level’ data. Surgeons,
journalists and the public need to understand these data if they
are to be useful in driving up standards of surgical care. This
Editorial describes the use of Funnel Plots, which are the common
means by which such data are presented, and discusses how the plots
are generated. Cite this article:
Our goal was to evaluate the use of Ponseti’s
method, with minor adaptations, in the treatment of idiopathic clubfeet
presenting in children between five and ten years of age. A retrospective
review was performed in 36 children (55 feet) with a mean age of
7.4 years (5 to 10), supplemented by digital images and video recordings
of gait. There were 19 males and 17 females. The mean follow-up
was 31.5 months (24 to 40). The mean number of casts was 9.5 (6
to 11), and all children required surgery, including a percutaneous
tenotomy or open tendo Achillis lengthening (49%), posterior release
(34.5%), posterior medial soft-tissue release (14.5%), or soft-tissue
release combined with an osteotomy (2%). The mean dorsiflexion of
the ankle was 9° (0° to 15°). Forefoot alignment was neutral in
28 feet (51%) or adducted (<
10°) in 20 feet (36%), >
10° in
seven feet (13%). Hindfoot alignment was neutral or mild valgus
in 26 feet (47%), mild varus (<
10°) in 19 feet (35%), and varus
(>
10°) in ten feet (18%). Heel–toe gait was present in 38 feet
(86%), and 12 (28%) exhibited weight-bearing on the lateral border
(out of a total of 44 feet with gait videos available for analysis).
Overt relapse was identified in nine feet (16%, six children). The
parents of 27 children (75%) were completely satisfied. A plantigrade foot was achieved in 46 feet (84%) without an extensive
soft-tissue release or bony procedure, although under-correction
was common, and longer-term follow-up will be required to assess
the outcome. Cite this article:
This study evaluates the position of the long
head of biceps tendon using ultrasound following simple tenotomy,
in patients with arthroscopically repaired rotator cuff tears. In total, 52 patients with a mean age of 60.7 years (45 to 75)
underwent arthroscopic repair of the rotator cuff and simple tenotomy
of the long head of biceps tendon. At two years post-operatively,
ultrasound revealed that the tendon was inside the bicipital groove
in 43 patients (82.7%) and outside in nine (17.3%); in six of these
it was lying just outside the groove and in the remaining three
(5.8%) it was in a remote position with a positive Popeye Sign.
A dynamic ultrasound scan revealed that the tenotomised tendons
had adhered to the surrounding tissues (autotenodesis).The initial
condition of the tendon influenced its final position (p <
0.0005).
The presence of a Popeye sign was statistically influenced by the
pre-operative co-existence of supraspinatus and subscapularis tears (p
<
0.0001). It appears that the natural history of the tenotomised long head
of biceps tendon is to tenodese itself inside or just outside the
bicipital groove, while its pre-operative condition and coexistent
subscapularis tears play a significant role in the occurrence of
a Popeye sign.
There have been a few reports of patients with
a combination of lumbar and thoracic spinal stenosis. We describe six
patients who suffered unexpected acute neurological deterioration
at a mean of 7.8 days (6 to 10) after lumbar decompressive surgery.
Five had progressive weakness and one had recurrent pain in the
lower limbs. There was incomplete recovery following subsequent
thoracic decompressive surgery. The neurological presentation can be confusing. Patients with
compressive myelopathy due to lower thoracic lesions, especially
epiconus lesions (T10 to T12/L1 disc level), present with similar
symptoms to those with lumbar radiculopathy or cauda equina lesions.
Despite the rarity of this condition we advise that patients who
undergo lumbar decompressive surgery for stenosis should have sagittal
whole spine MRI studies pre-operatively to exclude proximal neurological
compression. Cite this article:
The October 2012 Shoulder &
Elbow Roundup360 looks at: fast-absorbing suture anchors for use in shoulder labral tears; double-row rotator cuff repair; degenerate massive rotator cuff tears addressed with partial repair; open and arthroscopic stabilisation of Bankart lesions; predicting the risk of revision humeral head replacement; arthroscopic treatment for frozen shoulder; and long-term follow-up of the Bristow-Latarjet procedure.