Advertisement for orthosearch.org.uk
Results 121 - 140 of 776
Results per page:
Bone & Joint Open
Vol. 4, Issue 5 | Pages 306 - 314
3 May 2023
Rilby K Mohaddes M Kärrholm J

Aims

Although the Fitmore Hip Stem has been on the market for almost 15 years, it is still not well documented in randomized controlled trials. This study compares the Fitmore stem with the CementLeSs (CLS) in several different clinical and radiological aspects. The hypothesis is that there will be no difference in outcome between stems.

Methods

In total, 44 patients with bilateral hip osteoarthritis were recruited from the outpatient clinic at a single tertiary orthopaedic centre. The patients were operated with bilateral one-stage total hip arthroplasty. The most painful hip was randomized to either Fitmore or CLS femoral component; the second hip was operated with the femoral component not used on the first side. Patients were evaluated at three and six months and at one, two, and five years postoperatively with patient-reported outcome measures, radiostereometric analysis, dual-energy X-ray absorptiometry, and conventional radiography. A total of 39 patients attended the follow-up visit at two years (primary outcome) and 35 patients at five years. The primary outcome was which hip the patient considered to have the best function at two years.


Bone & Joint Open
Vol. 4, Issue 6 | Pages 463 - 471
23 Jun 2023
Baldock TE Walshaw T Walker R Wei N Scott S Trompeter AJ Eardley WGP

Aims

This is a multicentre, prospective assessment of a proportion of the overall orthopaedic trauma caseload of the UK. It investigates theatre capacity, cancellations, and time to surgery in a group of hospitals that is representative of the wider population. It identifies barriers to effective practice and will inform system improvements.

Methods

Data capture was by collaborative approach. Patients undergoing procedures from 22 August 2022 and operated on before 31 October 2022 were included. Arm one captured weekly caseload and theatre capacity. Arm two concerned patient and injury demographics, and time to surgery for specific injury groups.


The Bone & Joint Journal
Vol. 104-B, Issue 7 | Pages 902 - 908
1 Jul 2022
Hsu P Lee C Lin S Kuo KN Wu K Wang T

Aims

The aim of this study was to compare outcomes of guided growth and varus osteotomy in treating Kalamchi type II avascular necrosis (AVN) after open reduction and Pemberton acetabuloplasty for developmental dysplasia of the hip (DDH).

Methods

This retrospective study reviewed patients undergoing guided growth or varus osteotomy for Kalamchi type II AVN between September 2009 and January 2019. All children who had undergone open reduction and Pemberton acetabuloplasty for DDH with a minimum two-year follow-up were enrolled in the study. Demographic and radiological data, which included the head-shaft angle (HSA), neck-shaft angle (NSA), articulotrochanteric distance (ATD), Sharp angle (SA), and lateral centre-edge angle (LCEA) at baseline, two years, and at the extended follow-up, were compared. Revision rates were evaluated. Clinical outcomes using the Harris Hip Score were assessed two years postoperatively.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11_Supple_A | Pages 47 - 51
1 Nov 2012
Gustke K

The use of short stems has become more popular with the increased interest in less invasive approaches for total hip arthroplasty. The curved broaches and stem can be inserted along a curved track to avoid the abductor attachments. Short stems have the potential of being more bone conserving by allowing for higher neck retention, maintenance of the medial greater trochanter, and preferential stress transfer to the proximal femur. An initial experience with 500 new short stems (Fitmore, Zimmer Orthopedics) stems used for total hip arthroplasty is reported. No stems have been revised for aseptic loosening


Bone & Joint Research
Vol. 2, Issue 10 | Pages 206 - 209
1 Oct 2013
Griffin XL McArthur J Achten J Parsons N Costa ML

Fractures of the proximal femur are one of the greatest challenges facing the medical community, constituting a heavy socioeconomic burden worldwide. Controversy exists regarding the optimal treatment for patients with unstable trochanteric proximal femoral fractures. The recognised treatment alternatives are extramedullary fixation usually with a sliding hip screw and intramedullary fixation with a cephalomedullary nail. Current evidence suggests that best results and lowest complication rates occur using a sliding hip screw. Complications in these difficult fractures are relatively common regardless of type of treatment. We believe that a novel device, the X-Bolt dynamic plating system, may offer superior fixation over a sliding hip screw with lower reoperation risk and better function. We therefore propose to investigate the clinical effectiveness of the X-bolt dynamic plating system compared with standard sliding hip screw fixation within the framework of a the larger WHiTE (Warwick Hip Trauma Evaluation) Comprehensive Cohort Study. Cite this article: Bone Joint Res 2013;2:206–9


Bone & Joint Research
Vol. 6, Issue 5 | Pages 270 - 276
1 May 2017
Gosiewski JD Holsgrove TP Gill HS

Objectives. Fractures of the proximal femur are a common clinical problem, and a number of orthopaedic devices are available for the treatment of such fractures. The objective of this study was to assess the rotational stability, a common failure predictor, of three different rotational control design philosophies: a screw, a helical blade and a deployable crucifix. Methods. Devices were compared in terms of the mechanical work (W) required to rotate the implant by 6° in a bone substitute material. The substitute material used was Sawbones polyurethane foam of three different densities (0.08 g/cm. 3. , 0.16 g/cm. 3. and 0.24 g/cm. 3. ). Each torsion test comprised a steady ramp of 1°/minute up to an angular displacement of 10°. Results. The deployable crucifix design (X-Bolt), was more torsionally stable, compared to both the dynamic hip screw (DHS, p = 0.008) and helical blade (DHS Blade, p= 0.008) designs in bone substitute material representative of osteoporotic bone (0.16 g/cm. 3. polyurethane foam). In 0.08 g/cm. 3. density substrate, the crucifix design (X-Bolt) had a higher resistance to torsion than the screw (DHS, p = 0.008). There were no significant differences (p = 0.101) between the implants in 0.24 g/cm. 3. density bone substitute. Conclusions. Our findings indicate that the clinical standard proximal fracture fixator design, the screw (DHS), was the least effective at resisting torsional load, and a novel crucifix design (X-Bolt), was the most effective design in resisting torsional load in bone substitute material with density representative of osteoporotic bone. At other densities the torsional stability was also higher for the X-Bolt, although not consistently significant by statistical analysis. Cite this article: J. D. Gosiewski, T. P. Holsgrove, H. S. Gill. The efficacy of rotational control designs in promoting torsional stability of hip fracture fixation. Bone Joint Res 2017;6:270–276. DOI: 10.1302/2046-3758.65.BJR-2017-0287.R1


The Bone & Joint Journal
Vol. 105-B, Issue 5 | Pages 481 - 486
1 May 2023
Scott CEH Jain S Moran M Haddad FS

The Unified Classification System (UCS), or Vancouver system, is a validated and widely used classification system to guide the management of periprosthetic femoral fractures. It suggests that well-fixed stems (type B1) can be treated with fixation but that loose stems (types B2 and B3) should be revised. Determining whether a stem is loose can be difficult and some authors have questioned how to apply this classification system to polished taper slip stems which are, by definition, loose within their cement mantle. Recent evidence has challenged the common perception that revision surgery is preferable to fixation surgery for UCS-B periprosthetic fractures around cemented polished taper slip stems. Indications for fixation include an anatomically reducible fracture and cement mantle, a well-fixed femoral bone-cement interface, and a well-functioning acetabular component. However, not all type B fractures can or should be managed with fixation due to the risk of early failure. This annotation details specific fracture patterns that should not be managed with fixation alone.

Cite this article: Bone Joint J 2023;105-B(5):481–486.


The Bone & Joint Journal
Vol. 105-B, Issue 2 | Pages 215 - 219
1 Feb 2023
Buchan SJ Lindisfarne EA Stabler A Barry M Gent ED Bennet S Aarvold A

Aims

Fixation techniques used in the treatment of slipped capital femoral epiphysis (SCFE) that allow continued growth of the femoral neck, rather than inducing epiphyseal fusion in situ, have the advantage of allowing remodelling of the deformity. The aims of this study were threefold: to assess whether the Free-Gliding (FG) SCFE screw prevents further slip; to establish whether, in practice, it enables lengthening and gliding; and to determine whether the age of the patient influences the extent of glide.

Methods

All patients with SCFE who underwent fixation using FG SCFE screws after its introduction at our institution, with minimum three years’ follow-up, were reviewed retrospectively as part of ongoing governance. All pre- and postoperative radiographs were evaluated. The demographics of the patients, the grade of slip, the extent of lengthening of the barrel of the screw and the restoration of Klein’s line were recorded. Subanalysis was performed according to sex and age.


Bone & Joint 360
Vol. 12, Issue 2 | Pages 36 - 39
1 Apr 2023

The April 2023 Oncology Roundup360 looks at: Complete tumour necrosis after neoadjuvant chemotherapy defines good responders in patients with Ewing’s sarcoma; Monitoring vascularized fibular autograft: are radiographs enough?; Examining patient perspectives on sarcoma surveillance; The management of sacral tumours; Venous thromboembolism and major bleeding in the clinical course of osteosarcoma and Ewing’s sarcoma; Secondary malignancies after Ewing’s sarcoma: what is the disease burden?; Outcomes of distal radial endoprostheses for tumour reconstruction: a single centre experience over 15 years; Is anaerobic coverage during soft-tissue sarcoma resection needed?; Is anaerobic coverage during soft-tissue sarcoma resection needed?


Bone & Joint 360
Vol. 12, Issue 5 | Pages 39 - 42
1 Oct 2023

The October 2023 Oncology Roundup360 looks at: Are pathological fractures in patients with osteosarcoma associated with worse survival outcomes?; Spotting the difference: how secondary osteosarcoma manifests in retinoblastoma survivors versus conventional cases; Accuracy of MRI scans in predicting intra-articular joint involvement in high-grade sarcomas around the knee; Endoprosthetic reconstruction for lower extremity soft-tissue sarcomas with bone involvement; Local relapse of soft-tissue sarcoma of the extremities or trunk wall operated on with wide margins without radiation therapy; 3D-printed, custom-made prostheses in patients who had resection of tumours of the hand and foot; Long-term follow-up for low-grade chondrosarcoma; Evaluation of local recurrence and diagnostic discordance in chondrosarcoma patients undergoing preoperative biopsy; Radiological scoring and resection grade for intraosseous chondrosarcoma.


Bone & Joint Research
Vol. 11, Issue 12 | Pages 873 - 880
1 Dec 2022
Watanabe N Miyatake K Takada R Ogawa T Amano Y Jinno T Koga H Yoshii T Okawa A

Aims

Osteoporosis is common in total hip arthroplasty (THA) patients. It plays a substantial factor in the surgery’s outcome, and previous studies have revealed that pharmacological treatment for osteoporosis influences implant survival rate. The purpose of this study was to examine the prevalence of and treatment rates for osteoporosis prior to THA, and to explore differences in osteoporosis-related biomarkers between patients treated and untreated for osteoporosis.

Methods

This single-centre retrospective study included 398 hip joints of patients who underwent THA. Using medical records, we examined preoperative bone mineral density measures of the hip and lumbar spine using dual energy X-ray absorptiometry (DXA) scans and the medications used to treat osteoporosis at the time of admission. We also assessed the following osteoporosis-related biomarkers: tartrate-resistant acid phosphatase 5b (TRACP-5b); total procollagen type 1 amino-terminal propeptide (total P1NP); intact parathyroid hormone; and homocysteine.


Bone & Joint 360
Vol. 13, Issue 4 | Pages 26 - 29
2 Aug 2024

The August 2024 Shoulder & Elbow Roundup360 looks at: Comparing augmented and nonaugmented locking-plate fixation for proximal humeral fractures in the elderly; Elevated five-year mortality following shoulder arthroplasty for fracture; Total intravenous anaesthesia with propofol reduces discharge times compared with inhaled general anaesthesia in shoulder arthroscopy: a randomized controlled trial; The influence of obesity on outcomes following arthroscopic rotator cuff repair; Humeral component version has no effect on outcomes following reverse total shoulder arthroplasty: a prospective, double-blinded, randomized controlled trial; What is a meaningful improvement after total shoulder arthroplasty by implant type, preoperative diagnosis, and sex?; The safety of corticosteroid injection prior to shoulder arthroplasty: a systematic review; Mortality and subsequent fractures of patients with olecranon fractures compared to other upper limb osteoporotic fractures.


Bone & Joint 360
Vol. 13, Issue 3 | Pages 42 - 45
3 Jun 2024

The June 2024 Children’s orthopaedics Roundup360 looks at: Proximal femoral unicameral bone cysts: is ESIN the answer?; Hybrid-mesh casts in the conservative management of paediatric supracondylar humeral fractures: a randomized controlled trial; Rate and risk factors for contralateral slippage in adolescents treated for slipped capital femoral epiphysis; CRP predicts the need to escalate care after initial debridement for musculoskeletal infection; Genu valgum in paediatric patients presenting with patellofemoral instability; Nusinersen therapy changed the natural course of spinal muscular atrophy type 1: what about spine and hip?; The necessity of ulnar nerve exploration and translocation in open reduction of medial humeral epicondyle fractures in children.


Bone & Joint Open
Vol. 4, Issue 6 | Pages 416 - 423
2 Jun 2023
Tung WS Donnelley C Eslam Pour A Tommasini S Wiznia D

Aims

Computer-assisted 3D preoperative planning software has the potential to improve postoperative stability in total hip arthroplasty (THA). Commonly, preoperative protocols simulate two functional positions (standing and relaxed sitting) but do not consider other common positions that may increase postoperative impingement and possible dislocation. This study investigates the feasibility of simulating commonly encountered positions, and positions with an increased risk of impingement, to lower postoperative impingement risk in a CT-based 3D model.

Methods

A robotic arm-assisted arthroplasty planning platform was used to investigate 11 patient positions. Data from 43 primary THAs were used for simulation. Sacral slope was retrieved from patient preoperative imaging, while angles of hip flexion/extension, hip external/internal rotation, and hip abduction/adduction for tested positions were derived from literature or estimated with a biomechanical model. The hip was placed in the described positions, and if impingement was detected by the software, inspection of the impingement type was performed.


Bone & Joint Open
Vol. 4, Issue 11 | Pages 853 - 858
10 Nov 2023
Subbiah Ponniah H Logishetty K Edwards TC Singer GC

Aims

Metal-on-metal hip resurfacing (MoM-HR) has seen decreased usage due to safety and longevity concerns. Joint registries have highlighted the risks in females, smaller hips, and hip dysplasia. This study aimed to identify if reported risk factors are linked to revision in a long-term follow-up of MoM-HR performed by a non-designer surgeon.

Methods

A retrospective review of consecutive MoM hip arthroplasties (MoM-HRAs) using Birmingham Hip Resurfacing was conducted. Data on procedure side, indication, implant sizes and orientation, highest blood cobalt and chromium ion concentrations, and all-cause revision were collected from local and UK National Joint Registry records.


The Bone & Joint Journal
Vol. 106-B, Issue 4 | Pages 307 - 311
1 Apr 2024
Horner D Hutchinson K Bretherton CP Griffin XL


Bone & Joint 360
Vol. 13, Issue 2 | Pages 26 - 29
1 Apr 2024

The April 2024 Wrist & Hand Roundup360 looks at: Lunocapitate versus four-corner fusion in scapholunate or scaphoid nonunion advanced collapse: a randomized controlled trial; Postoperative scaphoid alignment, smoking, and avascular necrosis determine outcomes; Grip strength signals broader health concerns in females with distal radius fractures; Clearing the smoke: how smoking status influences recovery from open carpal tunnel release surgery; Age matters: assessing the likelihood of corrective surgery after distal radius fractures; Is pronator quadratus muscle repair required after anterior plate fixation for distal radius fractures?; Efficacy of total wrist arthroplasty: a comparative analysis of inflammatory and non-inflammatory arthritis outcomes; A comprehensive review of the one-bone forearm as a salvage technique.


Bone & Joint Open
Vol. 4, Issue 11 | Pages 825 - 831
1 Nov 2023
Joseph PJS Khattak M Masudi ST Minta L Perry DC

Aims

Hip disease is common in children with cerebral palsy (CP) and can decrease quality of life and function. Surveillance programmes exist to improve outcomes by treating hip disease at an early stage using radiological surveillance. However, studies and surveillance programmes report different radiological outcomes, making it difficult to compare. We aimed to identify the most important radiological measurements and develop a core measurement set (CMS) for clinical practice, research, and surveillance programmes.

Methods

A systematic review identified a list of measurements previously used in studies reporting radiological hip outcomes in children with CP. These measurements informed a two-round Delphi study, conducted among orthopaedic surgeons and specialist physiotherapists. Participants rated each measurement on a nine-point Likert scale (‘not important’ to ‘critically important’). A consensus meeting was held to finalize the CMS.


Bone & Joint Open
Vol. 3, Issue 12 | Pages 960 - 968
23 Dec 2022
Hardwick-Morris M Wigmore E Twiggs J Miles B Jones CW Yates PJ

Aims

Leg length discrepancy (LLD) is a common pre- and postoperative issue in total hip arthroplasty (THA) patients. The conventional technique for measuring LLD has historically been on a non-weightbearing anteroposterior pelvic radiograph; however, this does not capture many potential sources of LLD. The aim of this study was to determine if long-limb EOS radiology can provide a more reproducible and holistic measurement of LLD.

Methods

In all, 93 patients who underwent a THA received a standardized preoperative EOS scan, anteroposterior (AP) radiograph, and clinical LLD assessment. Overall, 13 measurements were taken along both anatomical and functional axes and measured twice by an orthopaedic fellow and surgical planning engineer to calculate intraoperator reproducibility and correlations between measurements.


Bone & Joint Open
Vol. 3, Issue 12 | Pages 991 - 997
23 Dec 2022
McPherson EJ Stavrakis AI Chowdhry M Curtin NL Dipane MV Crawford BM

Aims

Large acetabular bone defects encountered in revision total hip arthroplasty (THA) are challenging to restore. Metal constructs for structural support are combined with bone graft materials for restoration. Autograft is restricted due to limited volume, and allogenic grafts have downsides including cost, availability, and operative processing. Bone graft substitutes (BGS) are an attractive alternative if they can demonstrate positive remodelling. One potential product is a biphasic injectable mixture (Cerament) that combines a fast-resorbing material (calcium sulphate) with the highly osteoconductive material hydroxyapatite. This study reviews the application of this biomaterial in large acetabular defects.

Methods

We performed a retrospective review at a single institution of patients undergoing revision THA by a single surgeon. We identified 49 consecutive patients with large acetabular defects where the biphasic BGS was applied, with no other products added to the BGS. After placement of metallic acetabular implants, the BGS was injected into the remaining bone defects surrounding the new implants. Patients were followed and monitored for functional outcome scores, implant fixation, radiological graft site remodelling, and revision failures.