Advertisement for orthosearch.org.uk
Results 121 - 140 of 1756
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 2 | Pages 260 - 267
1 Mar 1991
Amis A Dawkins G

This work studied the fibre bundle anatomy of the anterior cruciate ligament. Three functional bundles--anteromedial, intermediate, and posterolateral--were identified in cadaver knees. Their contributions to resisting anterior subluxation in flexion and extension were found by repeated tests after sequential bundle transection. Changes of length in flexion and extension and in tibial rotation were measured. None of the fibres were isometric. The posterolateral bundle was stretched in extension and the anteromedial in flexion, which correlated with increased contributions to knee stability and the likelihood of partial ruptures in these positions. Tibial rotation had no significant effect. The fibre length changes suggested that the 'isometric point' aimed at by some ligament replacements lay anterior and superior to the femoral origin of the intermediate fibre bundle and towards the roof of the intercondylar notch


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 4 | Pages 579 - 582
1 May 2000
Nakata K Shino K Horibe S Natsu-ume T Mae T Ochi T

We have described a method of anatomical reconstruction of the lateral ligaments of the ankles with instability using allogeneic fascia lata dried with solvents and sterilised with gamma irradiation. Twenty ankles of 20 patients were assessed objectively and subjectively after a mean follow-up of 4.2 years (3.1 to 10). The result was excellent in 12 (60%), good in seven (35%) and fair in one (5%); none had a poor result. Stress radiography showed that the angle of talar tilt improved from 12.3 ± 4.2° (mean ±. sd. ) to 5.9 ± 3.0° and that the anterior drawer distance decreased from 9.2 ± 3.9 mm to 4.4 ± 2.5 mm. Neither infection nor limitation of movement occurred after operation. Fascia lata allografts provide a good alternative to autogenous grafts such as the peroneus brevis tendon


The Journal of Bone & Joint Surgery British Volume
Vol. 62-B, Issue 4 | Pages 497 - 499
1 Nov 1980
Jenkins D McKibbin B

The role of flexible carbon-fibre implants as substitutes for injured tendons and ligaments was investigated. These implants were simple to perform and were well tolerated by the patient. Repairs using carbon-fibres in 60 patients were successful, particularly in the almost insoluble problem of posterior cruciate laxity. The results in this report show that carbon-fibre implants have few disadvantages and have a future use in reconstructive procedures


The Bone & Joint Journal
Vol. 95-B, Issue 7 | Pages 917 - 922
1 Jul 2013
Sabouret P Lavoie F Cloutier J

We report on the long-term results of 163 bicruciate-retaining Hermes 2C total knee replacements in 130 patients at a mean follow-up of 22.4 years (20.3 to 23.5). Even when the anterior cruciate ligament had a partially degenerative appearance it was preserved as long as the knee had a normal anterior drawer and Lachman’s test pre-operatively. The description and surgical technique of this minimally constrained prosthesis were published in 1983 and the ten-year clinical results in 1999.

A total of 12% of the knees (20 of 163) in this study were revised because of wear of the polyethylene tibial insert. Excellent stability was achieved and the incidence of aseptic component loosening was 4.3% (seven of 163). The survival rate using revision for any reason as the endpoint was 82% (95% confidence interval 76.2 to 88.0).

Although this series included a relatively small number of replacements, it demonstrated that the anterior cruciate ligament, even when partially degenerated at the time of TKR, remained functional and provided adequate stability at a long-term follow-up.

Cite this article: Bone Joint J 2013;95-B:917–22.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 6 | Pages 885 - 885
1 Jun 2005
RAISBECK CC


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 6 | Pages 982 - 982
1 Nov 1995
McLain R


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 4 | Pages 480 - 491
1 May 2004
Dowd GSE


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 5 | Pages 747 - 747
1 May 2005
Allum R


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 3 | Pages 389 - 392
1 Apr 2003
Misra AN Hussain MRA Fiddian NJ Newton G

We randomised 129 knees which were to be replaced using a standard posterior-cruciate-ligament (PCL)-retaining cemented total knee replacement into two groups. In one the PCL was retained in the normal way and in the other it was resected. They were well matched, with a predominance of women, and a mean age of 67 years.

There was no statistically significant difference in the Hospital for Special Surgery scores at a mean of 57 months (56 to 60) between the two groups although 21 patients (24 knees) were lost to follow-up. Relief from pain, correction of deformity, range of movement, stability and strength were comparable in both. Radiological assessment showed femoral rollback in approximately 20% of knees with a slightly higher incidence in the PCL-resected group. There was no significant loosening detected in either group at review at two years.

At five years, one knee in the PCL-retained group had been revised because of infection and one patient in each group was awaiting revision for loosening.

Our findings have shown no significant difference in the five-year results for a PCL-retaining total knee replacement if the PCL is excised or preserved. This suggests two important points. First, the PCL is not functional in most patients with a total knee replacement even when retained. Secondly, patients with an excised PCL show a good result with a PCL-retaining implant, thereby questioning the need for a posterior stabilised design in such a situation.


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 7 | Pages 1086 - 1086
1 Sep 2002
WRIGHT I


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 5 | Pages 936 - 936
1 Sep 1999
Bollen S


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 3 | Pages 469 - 470
1 May 1992
Rao B Taraknath V Sista V


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 5 | Pages 630 - 637
1 May 2012
Bourke HE Gordon DJ Salmon LJ Waller A Linklater J Pinczewski LA

The purpose of this study was to report the outcome of ‘isolated’ anterior cruciate ligament (ACL) ruptures treated with anatomical endoscopic reconstruction using hamstring tendon autograft at a mean of 15 years (14.25 to 16.9). A total of 100 consecutive men and 100 consecutive women with ‘isolated’ ACL rupture underwent four-strand hamstring tendon reconstruction with anteromedial portal femoral tunnel drilling and interference screw fixation by a single surgeon. Details were recorded pre-operatively and at one, two, seven and 15 years post-operatively. Outcomes included clinical examination, subjective and objective scoring systems, and radiological assessment. At 15 years only eight of 118 patients (7%) had moderate or severe osteo-arthritic changes (International Knee Documentation Committee Grades C and D), and 79 of 152 patients (52%) still performed very strenuous activities. Overall graft survival at 15 years was 83% (1.1% failure per year). Patients aged < 18 years at the time of surgery and patients with > 2 mm of laxity at one year had a threefold increase in the risk of suffering a rupture of the graft (p = 0.002 and p = 0.001, respectively). There was no increase in laxity of the graft over time.

ACL reconstructive surgery in patients with an ‘isolated’ rupture using this technique shows good results 15 years post-operatively with respect to ligamentous stability, objective and subjective outcomes, and does not appear to cause osteoarthritis.


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 2 | Pages 173 - 175
1 Mar 1994
Moyen B Lerat J


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 1 | Pages 149 - 150
1 Jan 1988
Savage R


The Journal of Bone & Joint Surgery British Volume
Vol. 37-B, Issue 3 | Pages 443 - 445
1 Aug 1955
Alldred AJ


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 5 | Pages 777 - 777
1 Jul 2002
Dandy D


The Journal of Bone & Joint Surgery British Volume
Vol. 68-B, Issue 5 | Pages 827 - 828
1 Nov 1986
Kaelin A Hulin P Carlioz H

Instability of the knee is frequently found in association with congenital leg-length discrepancy. We have studied six such patients clinically, radiologically and arthroscopically. Clinical signs of knee instability and significant radiological changes were present in all, and at arthroscopy the anterior cruciate ligament was completely absent in four patients and functionless in the other two. This deficiency appears to be a congenital condition which may predispose to meniscus injury or retropatellar pain; it may also lead to subluxation or dislocation of the knee during leg-lengthening procedures.


The Journal of Bone & Joint Surgery British Volume
Vol. 64-B, Issue 1 | Pages 92 - 94
1 Feb 1982
Dandy D Pusey R


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 1 | Pages 147 - 147
1 Jan 2002
FORSTER M