Advertisement for orthosearch.org.uk
Results 121 - 140 of 354
Results per page:
The Bone & Joint Journal
Vol. 103-B, Issue 7 Supple B | Pages 9 - 16
1 Jul 2021
Hadden WJ Ibrahim M Taha M Ure K Liu Y Paish ADM Holdsworth DW Abdelbary H

Aims

The aims of this study were to develop an in vivo model of periprosthetic joint infection (PJI) in cemented hip hemiarthroplasty, and to monitor infection and biofilm formation in real-time.

Methods

Sprague-Dawley rats underwent cemented hip hemiarthroplasty via the posterior approach with pre- and postoperative gait assessments. Infection with Staphylococcus aureus Xen36 was monitored with in vivo photoluminescent imaging in real-time. Pre- and postoperative gait analyses were performed and compared. Postmortem micro (m) CT was used to assess implant integration; field emission scanning electron microscopy (FE-SEM) was used to assess biofilm formation on prosthetic surfaces.


The Journal of Bone & Joint Surgery British Volume
Vol. 35-B, Issue 2 | Pages 247 - 253
1 May 1953
Stratford B

1. Thirty-six cases of tuberculous hip disease treated by the Trumble type of extra-articular arthrodesis are reviewed. 2. The size and position of the graft, and the results and complications, are tabulated. 3. It is concluded that a short wide graft, placed almost horizontally between femur and ischium, gives the best results, and that a long obliquely placed graft is less satisfactory, and more liable to fracture or non-union


The Journal of Bone & Joint Surgery British Volume
Vol. 31-B, Issue 2 | Pages 222 - 226
1 May 1949
Foley WB

1. An operation is described for ischio-femoral extra-articular arthrodesis of the hip joint by posterior open approach, based on the techniques of Trumble and Brittain. 2. The operation has the advantages of affording adequate exposure of the sciatic nerve trunk and permitting visual control of the alignment and penetration of the chisel and graft. 3. The operation has been performed successfully without serious shock or subsequent complications in eighteen cases, mostly of tuberculosis of the hip


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 5 | Pages 807 - 811
1 Nov 1988
Maurice H Crone M Watt I

We reviewed 53 cases of synovial chondromatosis and compared their clinical, radiological and pathological features. A radiological diagnosis is possible with increasing frequency as the disease progresses; in the early phase arthrography is helpful. Radiologically the disease may be classified as either extra-articular, or intra-articular; the intra-articular variety may be localised or generalised. Recurrence after operation was seen in 11.5% and was much the same after either synovectomy or simple removal of loose bodies. A protocol for treatment is proposed


The Journal of Bone & Joint Surgery British Volume
Vol. 68-B, Issue 5 | Pages 739 - 746
1 Nov 1986
Shino K Kimura T Hirose H Inoue M Ono K

We describe the use of allogeneic human tendon as an intra-articular replacement for the anterior cruciate ligament. Depending on the type and degree of functional instability we recommend the addition, in some cases, of supplementary extra-articular procedures. We have reviewed 31 patients at least two years after operation and have found that 30 of them had been able to return to full sporting activities. The indications for operation and the techniques are discussed and the use of allogeneic tendon is recommended


The Journal of Bone & Joint Surgery British Volume
Vol. 68-B, Issue 1 | Pages 138 - 141
1 Jan 1986
Lynch M Taylor J

Therapeutic injection of facet joints is now widely practised, but British experience has been infrequently reported. We studied the results of injecting facet joints with a corticosteroid preparation in 50 patients suffering from the "facet syndrome". Our series included a number of extra-articular injections and these "failed injections" provide a useful control group. Results indicate that only intra-articular injections are effective; certainty of joint penetration can be ensured only by the routine use of joint arthrography


Bone & Joint 360
Vol. 10, Issue 3 | Pages 16 - 20
1 Jun 2021


The Bone & Joint Journal
Vol. 103-B, Issue 6 Supple A | Pages 150 - 157
1 Jun 2021
Anderson LA Christie M Blackburn BE Mahan C Earl C Pelt CE Peters CL Gililland J

Aims

Porous metaphyseal cones can be used for fixation in revision total knee arthroplasty (rTKA) and complex TKAs. This metaphyseal fixation has led to some surgeons using shorter cemented stems instead of diaphyseal engaging cementless stems with a potential benefit of ease of obtaining proper alignment without being beholden to the diaphysis. The purpose of this study was to evaluate short term clinical and radiographic outcomes of a series of TKA cases performed using 3D-printed metaphyseal cones.

Methods

A retrospective review of 86 rTKAs and nine complex primary TKAs, with an average age of 63.2 years (SD 8.2) and BMI of 34.0 kg/m2 (SD 8.7), in which metaphyseal cones were used for both femoral and tibial fixation were compared for their knee alignment based on the type of stem used. Overall, 22 knees had cementless stems on both sides, 52 had cemented stems on both sides, and 15 had mixed stems. Postoperative long-standing radiographs were evaluated for coronal and sagittal plane alignment. Adjusted logistic regression models were run to assess malalignment hip-knee-ankle (HKA) alignment beyond ± 3° and sagittal alignment of the tibial and femoral components ± 3° by stem type.


The Journal of Bone & Joint Surgery British Volume
Vol. 66-B, Issue 5 | Pages 706 - 710
1 Nov 1984
Dunlop R Adams M Hutton W

Cadaveric lumbar spine specimens of "motion segments", each including two vertebrae and the linking disc and facet joints, were compressed. The pressure across the facet joints was measured using interposed pressure-recording paper. This was repeated for 12 pairs of facet joints at four angles of posture and with three different disc heights. The results were that pressure between the facets increased significantly with narrowing of the disc space and with increasing angles of extension. Extra-articular impingement was found to be caused, or worsened, by disc space narrowing. Increased pressure or impingement may be a source of pain in patients with reduced disc spaces


The Journal of Bone & Joint Surgery British Volume
Vol. 35-B, Issue 4 | Pages 551 - 560
1 Nov 1953
Wilson JN

1. Thirty-one cases of tuberculosis of the elbow have been reviewed and the general characters of the disease described. 2. The condition is classified into four types distinguishable radiologically. 3. Treatment is predominantly conservative. Operation is sometimes indicated for extra-articular lesions. Arthrodesis is advisable in selected cases but it is not essential for healing. 4. Of twenty patients observed for five years or more, seventeen returned to work, seven required permanent splintage and five had residual pain or sinuses. 5. It is suggested that the best position for fixation of the elbow is 30 degrees below the right angle


The Journal of Bone & Joint Surgery British Volume
Vol. 68-B, Issue 3 | Pages 453 - 457
1 May 1986
Paterson F Trickey E

We have reviewed 40 patients after replacement of a ruptured anterior cruciate ligament with a free graft of the medial third of the patellar tendon, combining this in 17 of the cases with a MacIntosh extra-articular tenodesis. The average age of the patients at operation was 25.4 years; instability of the knee had been present for 1.5 to 9 years, and the mean follow-up was 2.9 years. The results, assessed on subjective stability, were good in 29 patients, over half being able to return to their original sport, and fair in eight. The technique of operation for free patellar tendon grafting is described in detail and the indications for this and for an additional MacIntosh tenodesis are discussed


The Journal of Bone & Joint Surgery British Volume
Vol. 68-B, Issue 1 | Pages 68 - 74
1 Jan 1986
Vishwakarma G Khare A

Arthroplasty of the hip using an interposed multi-layered cap of amniotic membrane is reported in 28 patients with tuberculous arthritis. The disease had been present from one to seven years, and five patients had multiple discharging sinuses. Follow-up was from 30 to 46 months. Amniotic tissue caused no inflammatory reaction, or obvious rejection, and 25 patients were free of symptoms, with a good range of movement and a stable joint. The three failures were caused by dislocation, fracture of the femoral neck and extra-articular bone formation respectively. Amniotic arthroplasty seems to be capable of providing a painless, mobile and stable joint in patients with tuberculosis of the hip


The Journal of Bone & Joint Surgery British Volume
Vol. 36-B, Issue 2 | Pages 202 - 208
1 May 1954
Kennedy JC Cameron H

1. Screw fixation of clavicle to coracoid process, with subsequent calcification and ossification along the conoid and trapezoid ligaments, creates an extra-articular fusion of the acromio-clavicular joint. 2. Though the follow-up is admittedly early, excellent results can be obtained in the young healthy adult. It is possible to return an athlete to competitive sports and a heavy labourer to full work in a surprisingly short time. 3. The operation is of doubtful value in older patients. 4. A precise operative technique is most important in producing a successful result. 5. Screw fixation introduces a new movement into the abduction mechanism of the shoulder: synchronous scapulo-clavicular rotation


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 5 | Pages 663 - 667
1 Jul 2001
Arazi M Memik R Ögün TC Yel M

Our aim was to determine the clinical effectiveness and safety of Ilizarov external fixation for the acute treatment of severely comminuted extra-articular and intercondylar fractures of the distal femur. A total of 14 consecutive patients with complex fractures was treated. There were three type-A3, two type-C2 and nine type-C3 fractures according to the AO/ASIF system. The mean follow-up was 14 months. Most fractures (13) united primarily at a mean of 16 weeks. One patient with a type-IIIA open fracture had infection and nonunion. The mean range of flexion of the knee at the final follow-up was 105° (35 to 130). We conclude that, in the treatment of comminuted fractures of the distal femur, the Ilizarov fixator is safe and effective in providing stability and allowing early rehabilitation


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 4 | Pages 588 - 592
1 Jul 1996
Rikli DA Regazzoni P

Fractures of the distal end of the radius should be treated on the same principles as other fractures involving joints. Displaced articular fractures require open reduction to allow anatomical reconstruction of both the radiocarpal and the radio-ulnar joints. For extra-articular fractures with severe comminution and shortening this enables the radial length to be re-established achieving radio-ulnar congruency. Stable internal fixation can be achieved with two 2.0 AO titanium plates placed on each of the ‘lateral’ and the ‘intermediate’ columns of the wrist at an angle of 50° to 70°. This gives good stability despite the tiny dimensions of the plates, and allows early function. We report a series of 20 fractures treated by this method of internal fixation with satisfactory results in all


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 3 | Pages 468 - 470
1 May 1996
Hayes AG Nadkarni JB

Surgical exposure of the ankle is usually obtained by an anterior approach, especially for replacement arthroplasty. The transfibular approach has been popular for arthrodesis. We describe a new posterior approach to the ankle and posterior subtalar joint based on an extra-articular vertical calcaneal osteotomy behind the subtalar joint. The posterior flap so formed is hinged medially and offers wide exposure of the back of the ankle and posterior subtalar joint. This hinge allows safe and stable reduction of the osteotomised calcaneum, and the plane of dissection follows an ‘internervous plane’ behind the fibula. We have had good results after using this incision in 12 patients with osteoarthritis or rheumatoid arthritis and there have been no difficulties with wound healing


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 2 | Pages 198 - 199
1 Mar 1994
Dandy D Desai S

We studied changes in patellar tendon length after reconstruction of the anterior cruciate ligament using either the medial third of the patellar tendon as a graft (n = 40) or a Leeds-Keio artificial ligament (n = 40). Both types of ligament replacement had been supplemented with a MacIntosh extra-articular lateral substitution. The mean change in length in the tendon graft group was 6% (SD 5.39); in the Leeds-Keio group it was 2.4% (SD 4.93). The change in length was significant in both groups, but shortening was more frequent and more severe in the tendon graft group. There was shortening of 10% or more in 25% of knees after patellar tendon graft and 7.5% after use of a Leeds-Keio prosthesis


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 1 | Pages 78 - 82
1 Jan 1998
Kerry RM Simonds GW

Over a 20-year period we treated 29 patients (31 dislocated hips) by non-operative reduction after nine months of age, using horizontal traction. They were followed up for a mean of 11.7 years, and 12 hips required secondary extra-articular surgery. The clinical result was excellent in 25 hips, good in four and fair in two. Of the 29 hips for which detailed radiographs were available, 18 achieved Severin grade I, nine grade II and two grade III. There were no major complications and, in particular, no cases of avascular necrosis. The non-operative reduction of late-presenting developmental dysplasia of the hip is still a viable option. It has a potential for excellent results and a very low complication rate


The Journal of Bone & Joint Surgery British Volume
Vol. 68-B, Issue 1 | Pages 117 - 120
1 Jan 1986
Soudry M Lanir A Angel D Roffman M Kaplan N Mendes D

Nuclear magnetic resonance imaging (MRI) was used to study the normal knee. As well as revealing bone quality, MRI provided useful information on intra-articular and extra-articular soft tissues. Midsagittal views gave clear images of the cruciate ligaments, and of the patellar and quadriceps tendons. Parasagittal views were the best for delineating the menisci which, like ligaments and tendons, are of low intensity; the semimembranosus tendon and its insertion to the proximal tibia were also seen clearly in these views. The cruciate ligaments and menisci, though visible in the coronal view also, were better seen in the sagittal view. Axial views provided information on the structure of the patella, its cartilage, the patellofemoral joint and posterior soft-tissue structures


The Journal of Bone & Joint Surgery British Volume
Vol. 43-B, Issue 1 | Pages 100 - 106
1 Feb 1961
Garden RS

1. Tennis elbow is largely an affliction of middle age, and it is believed that degenerative changes in the orbicular ligament may underlie its pathology. 2. It has been shown that most patients may be relieved by either extra-articular or intra-articular injection of hydrocortisone, and operative intervention is required only in a minority of cases. 3. Contraction of the extensor carpi radialis brevis is considered to be the principal pain-producing factor, and Z-lengthening of the tendon of this muscle has been found to relieve the symptoms when conservative measures have failed. 4. The late results in fifty patients have shown that this operation causes diminution neither of the power of wrist dorsiflexion nor in the efficiency of the grip. The operation may therefore be undertaken with every prospect of relieving the discomfort of tennis elbow without inviting alternative disability