Many knee replacement prostheses, embodying various principles of design, are now available and there is need for a method by which valid comparisons of results can be made. An important criterion of success is durability, so the length of time the prostheses have been in situ must be taken into account. Such a method is proposed here and is applied to the results of 673 knee replacements, of nine different types, implanted at the same hospital between 1970 and 1983. A prosthesis was considered to have
1. Sixty-nine patients with degenerative disease of the hip joint were treated by intra-articular arthrodesis using secure internal fixation. External fixation with plaster was not used and the patients were mobilised on crutches after a mean interval of 3·2 weeks. Radiologically evident bony union occurred in 87 per cent of cases. Among the nine patients (13 per cent) who
1. A case of essential osteolysis is presented, occurring in a young man of eighteen with no known family history and developing progressively from early childhood. The condition was radiologically evident in the elbows, hands and feet, and was accompanied by atrophy of the cancellous bone of the epiphyses of the shoulders and knees. It was also associated with certain abnormalities of the skull and vertebrae. The patient died from a nephropathy of late onset. 2. Examination of the left foot revealed on the radiologically "lysed" bony extremities a very slow process of erosion affecting essentially the epiphysial and metaphysial cortical bone, of a non-inflammatory nature and accompanied by disappearance of the hyaline cartilage. The extremities not radiologically "lysed" showed signs of erosion that were histologically similar but not macroscopically evident; they were accompanied by regressive changes in the hyaline cartilage. 3. There were no signs of renal osteodystrophy or of Sudeck's dystrophy. 4. Post-mortem tests revealed an increase in the seromucoids and
1. The end-results of conservative treatment of supraspinatus tears have been studied in a series of 109 patients graded on a clinical basis, and in a further series of twenty-seven patients assessed initially by procaine infiltration. 2. In 87 per cent. of patients with mild lesions, full function was regained in an average period of five and a half weeks. In more than 50 per cent. of patients with apparently severe lesions, there was full functional recovery in eleven to thirteen weeks. 3. Clinical assessment, other than as mild or apparently severe, is unreliable in the early stages. 4. Procaine infiltration of recent tears, by abolishing pain and spasm, allows more accurate assessment of supraspinatus function and gives a more clear indication as to the advisability of conservative or early operative treatment. If such infiltration of the torn segment of tendon
We have followed for 13 years a consecutive series of 31 patients who had open repair of a torn meniscus. They were between 13 and 43 years of age at the time of operation and all had intact stabilising ligaments. Comparison was made with a matched group of normal subjects of similar age and level of activity. The total rate of failure after meniscal repair was 29%; three of the repaired menisci did not heal and six reruptured during the follow-up period. At follow-up 80% of the patients had normal knee function for daily activities. Radiological changes were found in seven. Two had reduction of the joint space (Ahlbäck grade 1), one with successful and one with
Aims
Patients and Methods
The aims of this study were to review the surgical technique for a combined femoral head reduction osteotomy (FHRO) and periacetabular osteotomy (PAO), and to report the short-term clinical and radiological results of a combined FHRO/PAO for the treatment of selected severe femoral head deformities. Between 2011 and 2016, six female patients were treated with a combined FHRO and PAO. The mean patient age was 13.6 years (12.6 to 15.7). Clinical data, including patient demographics and patient-reported outcome scores, were collected prospectively. Radiologicalally, hip morphology was assessed evaluating the Tönnis angle, the lateral centre to edge angle, the medial offset distance, the extrusion index, and the alpha angle.Aims
Patients and Methods
Autologous chondrocyte implantation (ACI) and mosaicplasty are both claimed to be successful for the repair of defects of the articular cartilage of the knee but there has been no comparative study of the two methods. A total of 100 patients with a mean age of 31.3 years (16 to 49) and with a symptomatic lesion of the articular cartilage in the knee which was suitable for cartilage repair was randomised to undergo either ACI or mosaicplasty; 58 patients had ACI and 42 mosaicplasty. Most lesions were post-traumatic and the mean size of the defect was 4.66 cm. 2. The mean duration of symptoms was 7.2 years and the mean number of previous operations, excluding arthroscopy, was 1.5. The mean follow-up was 19 months (12 to 26). Functional assessment using the modified Cincinatti and Stanmore scores and objective clinical assessment showed that 88% had excellent or good results after ACI compared with 69% after mosaicplasty. Arthroscopy at one year demonstrated excellent or good repairs in 82% after ACI and in 34% after mosaicplasty. All five patellar mosaicplasties
Nine patients underwent arthrodesis of the knee using a customised coupled nail (the Mayday arthrodesis nail), five after infected arthroplasty, one following
The loss of cervical lordosis in radiographs of patients presenting with neck pain is sometimes ascribed to muscle spasm. We performed a cross-sectional study of the prevalence of 'straight' cervical spines in three populations: 83 patients presenting to an accident department with acute neck pain, 83 referred to a radiology department with chronic neck problems, and 80 radiographs from a normal population survey carried out in 1958. Curvature was assessed on lateral radiographs both subjectively and by measurement. The prevalence of 'straight' cervical spines was 19% in the acute cases and 26% in the chronic cases. The 95% confidence interval for the difference was -6.4% to +19.3%. In the normal population 42% showed a straight spine, but a further third of these films had been taken in a position of cervical kyphosis; this probably reflects a difference in positioning technique. Women were more likely than men to have a straight cervical spine, with an odds ratio of 2.81 (95% CI 1.23 to 6.44). Our results
Particulate wear debris is associated with periprosthetic inflammation and loosening in total joint arthroplasty. We tested the effects of titanium alloy (Ti-alloy) and PMMA particles on monocyte/macrophage expression of the C-C chemokines, monocyte chemoattractant protein-1 (MCP-1), monocyte inflammatory protein-1 alpha (MIP-1α), and regulated upon activation normal T expressed and secreted protein (RANTES). Periprosthetic granulomatous tissue was analysed for expression of macrophage chemokines by immunohistochemistry. Chemokine expression in human monocytes/macrophages exposed to Ti-alloy and PMMA particles in vitro was determined by RT-PCR, ELISA and monocyte migration. We observed MCP-1 and MIP-1α expression in all tissue samples from
A prospective study of allergic contact dermatitis after metal-on-plastic total hip replacement was undertaken in 69 patients, of whom 54 were available for review after operation. Before operation six patients were metal sensitive, but only one remained so afterwards; this patient had given a clear history of metal sensitivity and a titanium prosthesis had therefore been used. In all six patients the result of the operation was good and no case of loosening occurred. Sixty-three patients had negative patch tests before operation; in none of these was metal sensitivity detected after operation. Cutaneous sensitivity to various metals is well documented after the insertion of metal-on-metal prostheses and in
One thousand and forty-two McKee-Farrar prostheses of the present design inserted in Norwich from January 1965 to December 1972 have been reviewed retrospectively to determine the incidence of complications needing revision. Of prostheses implanted for more than two years, 6.6 per cent needed revision for loosening (cup 35 per cent; stem 2.2 per cent; both components 0.9 per cent). Of the total number, 2.3 per cent became infected and 1.9 per cent dislocated. Most dislocations needed only a single closed reduction but 08 per cent were revised. The outcome of revision operations was also assessed. Of revisions for loosening, 40 per cent needed no further operation but 23 per cent required excision; pelvic fracture or bone destruction around the components made success unlikely. Revisions for dislocation were disappointing. Of all revisions 17 per cent became infected. Excision arthroplasty is better than a series of
1. Articular cartilage from immature rabbits was placed in and near the rabbit knee joints for periods up to ten weeks. 2. Autografts of articular cartilage when placed free in the joint soon became adherent to its synovial lining; the cartilage with its subchondral bone remained viable. 3. Homografts remained viable in the presence of joint fluid, but when in contact with synovium antigenic cellular reaction was produced early. The presence of subchondral bone intensified this reaction and led to graft invasion and destruction. 4. Partial thickness homografts of articular cartilage were also antigenic and were absorbed. When full thickness cartilage was used, this cellular invasion was resisted by the zone of provisional calcification which appeared to function as a physical barrier against antigenic cells of the host. 5. When placed in muscle, both autogenous and homogenous grafts
1. Seventy-six patients with fracture of the upper end of the femur were examined phlebographically for evidence of thrombosis. The patients were randomly divided into two groups : one was given phenindione post-operatively ; the other acted as a control. 2. Analysis of the select series showed that the incidence of venous thrombosis in the anticoagulation group (19 per cent) was significantly less than that in the control group (48 per cent). 3. However, analysis of the complete series
We studied the time course of micro-embolism by recording high intensity transient signals (HITS) on Doppler venous blood flow studies during a 7-day period in 57 of 63 consecutive patients after hip or knee replacement. No HITS were found before surgery, or in the non-operated leg after surgery. In the operated leg, the median number of HITS per minute showed an exponential decrease with time; a 50% reduction in the number of HITS took 72 minutes. Regardless of the duration and severity of HITS, we found no clinically apparent embolic event. Colour Doppler imaging at days 8 to 10 after operation showed a deep venous thrombosis in 17% of our patients with one thrombosis of the long saphenous vein. The presence or severity of HITS did not predict the venous thrombi. Although we found no pulmonary complications, we detected micro-emboli over a longer period after surgery than is usually reported. Spectral analysis of the Doppler venous signal is a repeatable and non-invasive monitoring technique in the post-surgical period. We
This is a 15-year follow-up observational study of 4390 patients with 4606 primary total knee replacements (TKRs) implanted in the Trent health region between 1990 and 1992. The operations were performed in 21 hospitals, including both district general and teaching hospitals, with 77 different surgeons as named consultant. The main objective was to analyse the survival of the patients and of the prostheses, and to evaluate what impact different variables have on survival. In addition, the 1480 patients (33.7%) (1556 TKRs) alive at 15 years following operation were sent a self-administered questionnaire which examined their level of satisfaction, of pain, and their quality of life at 15 years. Completed responses were received from 912 TKRs (58.6%). Three survival curves were constructed: a best-case scenario based on the patients entered into the life tables, another included failures not reported in the revision database, and a third worst-case scenario based on all patients lost to follow-up presumed to have had a
The objective of this study was to investigate bone healing after
internal fixation of displaced femoral neck fractures (FNFs) with
the Dynamic Locking Blade Plate (DLBP) in a young patient population
treated by various orthopaedic (trauma) surgeons. We present a multicentre prospective case series with a follow-up
of one year. All patients aged ≤ 60 years with a displaced FNF treated
with the DLBP between 1st August 2010 and December 2014 were included.
Patients with pathological fractures, concomitant fractures of the
lower limb, symptomatic arthritis, local infection or inflammation,
inadequate local tissue coverage, or any mental or neuromuscular
disorder were excluded. Primary outcome measure was failure in fracture
healing due to nonunion, avascular necrosis, or implant failure
requiring revision surgery.Aims
Patients and Methods
We have reviewed 29 patients (30 hips) who had undergone revision total hip arthroplasty using a Freeman metal-backed acetabular component and acetabular impaction allografting. The mean follow-up was for 15.3 years (12 to 17). Five patients (5 hips) died with the prosthesis in situ and four (4 hips) were lost to follow-up. Twelve hips had
We report the incidence of osteolysis in the femur, tibia, and patella of 44 consecutive patients (60 knees) who were followed for more than seven years after cementless knee arthroplasty with a Porous-Coated Anatomic prosthesis. The average age of the patients was 56.5 years (17 to 73); the operative diagnosis was osteoarthritis (33 knees), rheumatoid arthritis (17), tuberculous arthritis (7) and post-traumatic arthritis (3). All patellae were resurfaced. No femoral or tibial component was loose at the final follow-up examination. Thirty patellar components were loose of which six had been revised. Radiographs revealed osteolysis in 90% of the tibial plateaux and in 80% of the 30 intact patellar prostheses. No osteolysis was seen around any femoral component. In 50 knees (83%) the average wear of the polyethylene liner was 2.5 mm in the medial compartment and 1.7 mm in the lateral compartment. Four of 60 knees (6.7%) were revised for complete wear of the polyethylene liner of the tibial component. Fixation of the tibial and patellar components without cement