This study compared the outcome of total knee
replacement (TKR) in adult patients with fixed- and mobile-bearing prostheses
during the first post-operative year and at five years’ follow-up,
using gait parameters as a new objective measure. This double-blind
randomised controlled clinical trial included 55 patients with mobile-bearing (n
= 26) and fixed-bearing (n = 29) prostheses of the same design,
evaluated pre-operatively and post-operatively at six weeks, three
months, six months, one year and five years. Each participant undertook
two walking trials of 30 m and completed the EuroQol questionnaire,
Western Ontario and McMaster Universities osteoarthritis index,
Knee Society score, and visual analogue scales for pain and stiffness.
Gait analysis was performed using five miniature angular rate sensors
mounted on the trunk (sacrum), each thigh and calf. The study population
was divided into two groups according to age (≤ 70 years Improvements in most gait parameters at five years’ follow-up
were greater for fixed-bearing TKRs in older patients (>
70 years),
and greater for mobile-bearing TKRs in younger patients (≤ 70 years).
These findings should be confirmed by an extended age controlled
study, as the ideal choice of prosthesis might depend on the age
of the patient at the time of surgery.
The accuracy and precision of two new methods of model-based
radiostereometric analysis (RSA) were hypothesised to be superior
to a plain radiograph method in the assessment of polyethylene (PE)
wear. A phantom device was constructed to simulate three-dimensional
(3D) PE wear. Images were obtained consecutively for each simulated
wear position for each modality. Three commercially available packages
were evaluated: model-based RSA using laser-scanned cup models (MB-RSA),
model-based RSA using computer-generated elementary geometrical
shape models (EGS-RSA), and PolyWare. Precision (95% repeatability
limits) and accuracy (Root Mean Square Errors) for two-dimensional
(2D) and 3D wear measurements were assessed.Objectives
Methods
A total of 14 women and seven men with a mean age of 43 years (18 to 68) who sustained a Mason type IV fracture of the elbow, without an additional type II or III coronoid fracture, were evaluated after a mean of 21 years (14 to 46). Primary treatment included closed elbow reduction followed by immobilisation in a plaster in all cases, with an additional excision of the radial head in 11, partial resection in two and suturing of the annular ligament in two. Delayed radial head excision was performed in two patients and an ulnar nerve transposition in one. The uninjured elbows served as controls. Nine patients had no symptoms, 11 reported slight impairment, and one severe impairment of the elbow. Elbow flexion was impaired by a mean of 3° ( We conclude that most patients with a Mason type IV fracture of the elbow report a good long-term outcome.
The responsiveness of the Manchester–Oxford Foot
Questionnaire (MOXFQ) was compared with foot/ankle-specific and
generic outcome measures used to assess all surgery of the foot
and ankle. We recruited 671 consecutive adult patients awaiting
foot or ankle surgery, of whom 427 (63.6%) were female, with a mean
age of 52.8 years (18 to 89). They independently completed the MOXFQ,
Short-Form 36 (SF-36) and EuroQol (EQ-5D) questionnaires pre-operatively
and at a mean of nine months (3.8 to 14.4) post-operatively. Foot/ankle
surgeons assessed American Orthopaedic Foot and Ankle Society (AOFAS)
scores corresponding to four foot/ankle regions. A transition item measured
perceived changes in foot/ankle problems post-surgery. Of 628 eligible
patients proceeding to surgery, 491 (78%) completed questionnaires
and 262 (42%) received clinical assessments both pre- and post-operatively. The
regions receiving surgery were: multiple/whole foot in eight (1.3%),
ankle/hindfoot in 292 (46.5%), mid-foot in 21 (3.3%), hallux in
196 (31.2%), and lesser toes in 111 (17.7%). Foot/ankle-specific
MOXFQ, AOFAS and EQ-5D domains produced larger effect sizes (>
0.8)
than any SF-36 domains, suggesting superior responsiveness. In analyses
that anchored change in scores and effect sizes to patients’ responses
to a transition item about their foot/ankle problems, the MOXFQ
performed well. The SF-36 and EQ-5D performed poorly. Similar analyses,
conducted within foot-region based sub-groups of patients, found
that the responsiveness of the MOXFQ was good compared with the
AOFAS. This evidence supports the MOXFQ’s suitability for assessing
all foot and ankle surgery.
This year is the centenary of the birth of John Charnley. Some of his legacy to Orthopaedic Surgery is described in this editorial.
We present a retrospective review of a single-surgeon series of 30 consecutive lengthenings in 27 patients with congenital short femur using the Ilizarov technique performed between 1994 and 2005. The mean increase in length was 5.8 cm/18.65% (3.3 to 10.4, 9.7% to 48.8%), with a mean time in the frame of 223 days (75 to 363). By changing from a distal to a proximal osteotomy for lengthening, the mean range of knee movement was significantly increased from 98.1° to 124.2° (p = 0.041) and there was a trend towards a reduced requirement for quadricepsplasty, although this was not statistically significant (p = 0.07). The overall incidence of regenerate deformation or fracture requiring open reduction and internal fixation was similar in the distal and proximal osteotomy groups (56.7% and 53.8%, respectively). However, in the proximal osteotomy group, pre-placement of a Rush nail reduced this rate from 100% without a nail to 0% with a nail (p <
0.001). When comparing a distal osteotomy with a proximal one over a Rush nail for lengthening, there was a significant decrease in fracture rate from 58.8% to 0% (p = 0.043). We recommend that in this group of patients lengthening of the femur with an Ilizarov construct be carried out through a proximal osteotomy over a Rush nail. Lengthening should also be limited to a maximum of 6 cm during one treatment, or 20% of the original length of the femur, in order to reduce the risk of complications.
Early failure associated with adverse reactions to metal debris is an emerging problem after hip resurfacing but the exact mechanism is unclear. We analysed our entire series of 660 metal-on-metal resurfacings (Articular Surface Replacement (ASR) and Birmingham Hip Resurfacing (BHR)) and large-bearing ASR total hip replacements, to establish associations with metal debris-related failures. Clinical and radiological outcomes, metal ion levels, explant studies and lymphocyte transformation tests were performed. A total of 17 patients (3.4%) were identified (all ASR bearings) with adverse reactions to metal debris, for which revision was required. This group had significantly smaller components, significantly higher acetabular component anteversion, and significantly higher whole concentrations of blood and joint chromium and cobalt ions than asymptomatic patients did (all p <
0.001). Post-revision lymphocyte transformation tests on this group showed no reactivity to chromium or cobalt ions. Explants from these revisions had greater surface wear than retrievals for uncomplicated fractures. The absence of adverse reactions to metal debris in patients with well-positioned implants usually implies high component wear. Surgeons must consider implant design, expected component size and acetabular component positioning in order to reduce early failures when performing large-bearing metal-on-metal hip resurfacing and replacement.
Since September 1964, neonates born in New Plymouth have undergone clinical examination for instability of the hip in a structured clinical screening programme. Of the 41 563 babies born during this period, 1639 were diagnosed as having unstable hips and 663 (1.6%) with persisting instability were splinted, five of which failed. Also, three unsplinted hips progressed to congenital dislocation, and there were four late-presenting (walking) cases, giving an overall failure rate of 0.29 per 1000 live births, with an incidence of late-walking congenital dislocation of the hip of 0.1 per 1000 live births. This study confirms that clinical screening for neonatal instability of the hip by experienced orthopaedic examiners significantly reduces the incidence of late-presenting (walking) congenital dislocation of the hip.
Painful neuromas may follow traumatic nerve injury. We carried out a double-blind controlled trial in which patients with a painful neuroma of the lower limb (n = 20) were randomly assigned to treatment by resection of the neuroma and translocation of the proximal nerve stump into either muscle tissue or an adjacent subcutaneous vein. Translocation into a vein led to reduced intensity of pain as assessed by visual analogue scale (5.8 (sd 2.7) vs 3.8 (sd 2.4); p <
0.01), and improved sensory, affective and evaluative dimensions of pain as assessed by the McGill pain score (33 (sd 18) vs 14 (sd 12); p <
0.01). This was associated with an increased level of activity (p <
0.01) and improved function (p <
0.01). Transposition of the nerve stump into an adjacent vein should be preferred to relocation into muscle.
We evaluated the safety and efficacy of total
knee replacement in patients receiving continuous warfarin therapy. We identified 24 consecutive patients receiving long-term warfarin
therapy who underwent total knee replacement between 2006 and 2008
and compared them with a group of age- and gender-matched patients
not on long-term anticoagulation. Primary observations were changes
in haemoglobin, transfusion rates and complications. Secondary observations
were fluctuations in the international normalised ratio (INR) and
post-operative range of movement. There was no significant difference between the two groups in
pre- or post-operative haemoglobin, incidence of transfusion or
incidence of post-operative complications. There were no surgical
delays due to a high INR level. The mean change in INR during the
peri-operative phase was minimal (mean 0.4; Current American College of Chest Physicians guidelines recommend
bridging therapy for high-risk patients receiving oral anticoagulation
and undergoing major orthopaedic procedures. We have shown that
a safe alternative is to continue the steady-state warfarin peri-operatively
in patients on long-term anticoagulation requiring total knee replacement.
Blood metal ions have been widely used to investigate
metal-on-metal hip replacements, but their ability to discriminate
between well-functioning and failed hips is not known. The Medicines
and Healthcare products Regulatory Agency (MHRA) has suggested a
cut-off level of 7 parts per billion (ppb). We performed a pair-matched, case-control study to investigate
the sensitivity and specificity of blood metal ion levels for diagnosing
failure in 176 patients with a unilateral metal-on-metal hip replacement.
We recruited 88 cases with a pre-revision, unexplained failed hip
and an equal number of matching controls with a well-functioning
hip. We investigated the 7 ppb cut-off level for the maximum of
cobalt or chromium and determined optimal mathematical cut-off levels
from receiver-operating characteristic curves. The 7 ppb cut-off level for the maximum of cobalt or chromium
had a specificity of 89% and sensitivity 52% for detecting a pre-operative
unexplained failed metal on metal hip replacement. The optimal cut-off
level for the maximum of cobalt or chromium was 4.97 ppb and had
sensitivity 63% and specificity 86%. Blood metal ions had good discriminant ability to separate failed
from well-functioning hip replacements. The MHRA cut-off level of
7 ppb provides a specific test but has poor sensitivity.
We examined the differences in post-operative
functional disability and patient satisfaction between 56 patients who
underwent a lumbar fusion at three or more levels for degenerative
disease (group I) and 69 patients, matched by age and gender, who
had undergone a one or two level fusion (group II). Their mean age
was 66 years (49 to 84) and the mean follow-up was 43 months (24
to 65). The mean pre-operative Oswestry Disability Index (ODI) and visual
analogue scale (VAS) for back and leg pain, and the mean post-operative
VAS were similar in both groups (p >
0.05), but post-operatively
the improvement in ODI was significantly less in group I (40.6%)
than in group II (49.5%) (p <
0.001). Of the ten ODI items, patients
in group I showed significant problems with lifting, sitting, standing,
and travelling (p <
0.05). The most significant differences in
the post-operative ODI were observed between patients who had undergone
fusion at four or more levels and those who had undergone fusion
at less than four levels (p = 0.005). The proportion of patients
who were satisfied with their operations was similar in groups I
and II (72.7% and 77.0%, respectively) (p = 0.668). The mean number
of fused levels was associated with the post-operative ODI (r =
0.266, p = 0.003), but not with the post-operative VAS or satisfaction
grade (p >
0.05). Post-operative functional disability was more
severe in those with a long-level lumbar fusion, particularly at
four or more levels, but patient satisfaction remained similar for
those with both long- and short-level fusions.
Femoral lengthening using the Intramedullary Skeletal Kinetic Distractor is a new technique. However, with intramedullary distraction the surgeon has less control over the lengthening process. Therefore, 33 femora lengthened with this device were assessed to evaluate the effect of operative variables under the surgeon’s control on the course of lengthening. The desired lengthening was achieved in 32 of 33 limbs. Problems encountered included difficulty in achieving length in eight femora (24%) and uncontrolled lengthening in seven (21%). Uncontrolled lengthening was more likely if the osteotomy was placed with less than 80 mm of the thick portion of the nail in the distal fragment (p = 0.052), and a failure to lengthen was more likely if there was over 125 mm in the distal fragment (p = 0.008). The latter problem was reduced with over-reaming by 2.5 mm to 3 mm. Previous intramedullary nailing also predisposed to uncontrolled lengthening (p = 0.042), and these patients required less reaming. Using the Intramedullary Skeletal Kinetic Distractor, good outcomes were obtained; problems were minimised by optimising the position of the osteotomy and the amount of over-reaming performed.
The Oxford hip and knee scores are used to measure the outcome after primary total hip and knee replacement. We propose a new layout for the instrument in which patients are always asked about both limbs. In addition, we have defined an alternative scoring method which accounts for missing data. Over a period of 4.5 years, 4086 (1423 patients) and 5708 (1458 patients) questionnaires were completed for hips and knees, respectively. The hip score had a pre-operative median of 70.8 (interquartile range (IQR) 58.3 to 81.2) decreasing to 20.8 (IQR 10.4 to 35.4) after one year. The knee score had a pre-operative median of 68.8 (IQR 56.2 to 79.2) decreasing to 29.2 (IQR 14.6 to 45.8). There was no further significant change in either score after one year. As a result of the data analysis, we suggest that the score percentiles can be used as a standard for auditing patients before and after operation.
Isolated fractures of the anterior column and anterior wall are a relatively rare subgroup of acetabular fractures. We report our experience of 30 consecutive cases treated over ten years. Open reduction and internal fixation through an ilioinguinal approach was performed for most of these cases (76.7%) and percutaneous techniques were used for the remainder. At a mean follow-up of four years (2 to 6), 26 were available for review. The radiological and functional outcomes were good or excellent in 23 of 30 patients (76.7%) and 22 of 26 patients (84.6%) according to Matta’s radiological criteria and the modified Merlé d’Aubigné score, respectively. Complications of minor to moderate severity were seen in six of the 30 cases (20%) and none of the patients underwent secondary surgery or replacement of the hip.
The diagnosis of a meniscal tear may require MRI, which is costly. Ultrasonography has been used to image the meniscus, but there are no reliable data on its accuracy. We performed a prospective study investigating the sensitivity and specificity of ultrasonography in comparison with MRI; the final outcome was determined at arthroscopy. The study included 35 patients with a mean age of 47 years (14 to 73). There was a sensitivity of 86.4% (95% confidence interval (CI) 75 to 97.7), a specificity of 69.2% (95% CI 53.7 to 84.7), a positive predictive value of 82.6% (95% CI 70 to 95.2) and a negative predictive value of 75% (95% CI 60.7 to 81.1) for ultrasonography. This compared favourably with a sensitivity of 86.4% (95% CI 75 to 97.7), a specificity of 100.0%, a positive predictive value of 100.0% and a negative predictive value of 81.3% (95% CI 74.7 to 87.9) for MRI. Given that the sensitivity matched that of MRI we feel that ultrasonography can reasonably be applied to confirm the clinical diagnosis before undertaking arthroscopy. However, the lower specificity suggests that there is still a need to improve the technique to reduce the number of false-positive diagnoses and thus to avoid unnecessary arthroscopy.
A 60-year-old man developed severe neuropathic pain and foot-drop in his left leg following resurfacing arthroplasty of the left hip. The pain was refractory to all analgesics for 16 months. At exploration, a PDS suture was found passing through the sciatic nerve at several points over 6 cm and terminating in a large knot. After release of the suture and neurolysis there was dramatic and rapid improvement of the neuropathic pain and of motor function. This case represents the human equivalent of previously described nerve ligation in an animal model of neuropathic pain. It emphasises that when neuropathic pain is present after an operation, the nerve related to the symptoms must be inspected, and that removal of a suture or irritant may lead to relief of pain, even after many months.
Between 1989 and 1992 we had 102 knees suitable for unicompartmental knee replacement (UKR). They were randomised to receive either a St Georg Sled UKR or a Kinematic modular total knee replacement (TKR). The early results demonstrated that the UKR group had less complications and more rapid rehabilitation than the TKR group. At five years there were an equal number of failures in the two groups but the UKR group had more excellent results and a greater range of movement. The cases were reviewed by a research nurse at 8, 10 and 12 years after operation. We report the outcome at 15 years follow-up. A total of 43 patients (45 knees) died with their prosthetic knees intact. Throughout the review period the Bristol knee scores of the UKR group have been better and at 15 years 15 (71.4%) of the surviving UKRs and 10 (52.6%) of the surviving TKRs had achieved an excellent score. The 15 years survivorship rate based on revision or failure for any reason was 24 (89.8%) for UKR and 19 (78.7%) for TKR. During the 15 years of the review four UKRs and six TKRs failed. The better early results with UKR are maintained at 15 years with no greater failure rate. The median Bristol knee score of the UKR group was 91.1 at five years and 92 at 15 years, suggesting little functional deterioration in either the prosthesis or the remainder of the joint. These results justify the increased use of UKR.
We describe a case of rotational dislocation of the proximal interphalangeal joint of the ring finger. This injury was not initially appreciated and therefore closed reduction failed. The clinical findings included puckering of the skin on the dorsum of the joint and rotational incongruity on radiographs. At open reduction there was interposition of the lateral band. Identification of the pathology allows early successful treatment.
Deep prosthetic joint infection remains an uncommon but serious complication of total hip replacement. We reviewed 24 patients with recalcitrant hip wounds following infected total hip replacement treated with either pedicled rectus femoris or vastus lateralis muscle flaps between 1998 and 2009. The mean age of the patients was 67.4 years (42 to 86) with ten men and 14 women. There had been a mean of four (1 to 8) previous attempts to close the wound. A total of 20 rectus femoris and five vastus lateralis flaps were used, with one of each type of flap failing and requiring further reconstruction. All patients had positive microbiology. At a mean follow-up of 47 months (9 to 128), 22 patients had a healed wound and two had a persistent sinus. The prosthesis had been retained in five patients. In the remainder it had been removed, and subsequently re-implanted in nine patients. Six patients continued to take antibiotics at final follow-up. This series demonstrates the effectiveness of pedicled muscle flaps in healing these infected wounds. The high number of previous debridements suggests that these flaps could have been used earlier.