Advertisement for orthosearch.org.uk
Results 1201 - 1220 of 6074
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11_Supple_A | Pages 26 - 31
1 Nov 2012
Mayle RE Della Valle CJ

The purpose of this paper is to discuss the risk factors, prevention strategies, classification, and treatment of intra-operative femur fractures sustained during primary and revision total hip arthroplasty.


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 1 | Pages 11 - 12
1 Jan 1991
Gregory R Gibson M Moran C

Dislocation is the most frequent serious complication following total hip replacement for subcapital femoral fracture. We report a prospective study, using matched groups, which compared the range of hip movement following hip replacement for arthritis and for fracture. The range of movement was significantly greater in the fracture group. We suggest that this is a predisposing factor for dislocation


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 3 | Pages 416 - 417
1 May 1992
Proubasta I

External fixation of the first metacarpal was used in Rolando's fracture to counter the forces that cause shortening and articular incongruity. Satisfactory reduction was achieved and maintained in five patients


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 2 | Pages 315 - 319
1 Feb 2010
Lalliss SJ Branstetter JG

Using an osteotomy of the olecranon as a model of a transverse fracture in 22 cadaver elbows we determined the ability of three different types of suture and stainless steel wire to maintain reduction when using a tension-band technique to stabilise the bone. Physiological cyclical loading simulating passive elbow movement (15 N) and using the arms to push up from a chair (450 N) were applied using an Instron materials testing machine whilst monitoring the osteotomy site with a video extensometer. Each osteotomy was repaired by one of four materials, namely, Stainless Steel Wire (7), No 2 Ethibond (3), No 5 Ethibond (5), or No 2 FiberWire (7). There were no failures (movement of > 2 mm) with stainless steel wire or FiberWire and no significant difference in the movements measured across the site of the osteotomy (p = 0.99). The No. 2 Ethibond failed at 450 N and two of the five of No. 5 Ethibond sutures had a separation of > 2 mm at 450 N. FiberWire as the tension band in this model held the reduction as effectively as stainless steel wire and may reduce the incidence of discomfort from the hardware. On the basis of our findings we suggest that a clinical trial should be undertaken


The Journal of Bone & Joint Surgery British Volume
Vol. 45-B, Issue 4 | Pages 727 - 731
1 Nov 1963
Wright PR

1. Five cases of greenstick fracture of the upper end of the ulna with dislocation of the radio-humeral joint are described. 2. Although the direction of angulation of the fracture and the corresponding displacement of the upper end of the radius may be lateral, medial or anterior, it is suggested that all five cases form a group in which the mechanism of injury is essentially the same. This mechanism is considered to be a fall on the outstretched hand with the forearm held in supination. 3. The complications of the injury are described


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 2 | Pages 204 - 205
1 Mar 2001
Thomas RH Holt MD James SH White PG

The imaging techniques available to aid the diagnosis of ruptures of tendo Achillis, the rotator cuff and the tendon of tibialis posterior in rheumatoid patients are well described. However, ruptures of tendon or muscle at other sites are uncommon and may be overlooked. Diagnosis is often made by localised tenderness, swelling and a lack of active movement associated with a palpable defect. Clinical examination may be inconclusive and can be aided by imaging studies. We report two cases in which ruptures of a tendon were suspected, and ultrasound imaging demonstrated the palpable defect to be a cleavage plane in the subcutaneous fat – a ‘fat fracture’


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 4 | Pages 534 - 536
1 Jul 1997
Barbier O Malghem J Delaere O Vande Berg B Rombouts JJ

Clavicular fractures are occasionally responsible for lesions of the brachial plexus. The symptoms are usually delayed and due to compression by hypertrophic callus, nonunion or a subclavian pseudoaneurysm. We describe a patient in whom a displaced bone fragment was pressing on the retroclavicular part of the brachial plexus, leading to early symptoms of a lesion of the posterior cord. Internal fixation of the clavicle and external neurolysis of the brachial plexus gave an almost full recovery


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 2 | Pages 270 - 271
1 Mar 1992
Astrom J Beertema J

In a population-based study we identified a cohort of 282 women, whose children had been treated for osteoarthritis of the hip. The incidence of hip fracture in these mothers was 0.54 (95% CI 0.35 to 0.83) of that in the whole population of their age and sex. This finding could be explained by a genetic factor for increased rigidity of subchondral bone, making osteoarthritis more likely and osteoporosis less likely


The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 3 | Pages 471 - 474
1 May 1989
Pryor G Williams D

The rehabilitation of elderly patients after hip fractures is important: we report a prospective study which compares supported home rehabilitation with management in hospital in two similar groups of patients. Our results show that early discharge from hospital and home rehabilitation produces substantial savings in bed days, and also provides quicker and more effective recovery


The Journal of Bone & Joint Surgery British Volume
Vol. 68-B, Issue 4 | Pages 577 - 583
1 Aug 1986
Piggot J Graham H McCoy G

Ninety-eight children with severely displaced supracondylar fractures of the humerus were treated by straight lateral traction. After a mean follow-up period of 3.5 years there were 90 satisfactory and only eight unsatisfactory results. Cubitus varus was present in only four children, which compares favourably with the results of operative treatment. The indications for straight lateral traction, and the advantages of this method, are discussed


The Journal of Bone & Joint Surgery British Volume
Vol. 68-B, Issue 4 | Pages 610 - 613
1 Aug 1986
Rowley D Norris S Duckworth T

A series of 42 ankle fractures have been randomised into two groups respectively undergoing either open reduction and internal fixation or manipulative reduction and plaster. Their progress after removal of all external splintage has been followed using simple gait analysis techniques. There appears to be no difference in the outcome of treatment of the two groups in the early recovery period (up to 20 weeks)


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 8 | Pages 1168 - 1172
1 Nov 2001
Goldfarb CA Bassett GS Sullivan S Gordon JE

Retrosternal displacement of the medial aspect of the clavicle after physeal fracture is rare. We treated six patients with this injury between 1995 and 1998, all as an emergency in order to avoid complications associated with compression of adjacent mediastinal structures. Attempted closed reduction was undertaken, but all required open reduction and internal fixation using a wire suture. There were no associated complications. Five were reviewed clinically and radiologically at a minimum of one year after operation. All had regained full use of the affected arm without pain and had resumed their preinjury level of activity including sports. Follow-up radiographs showed union in the anatomical position in all patients. We recommend attempted closed reduction in the operating room, followed, if necessary, by open reduction. Internal fixation after open reduction gives stable fixation with minimal morbidity


The Journal of Bone & Joint Surgery British Volume
Vol. 63-B, Issue 1 | Pages 3 - 6
1 Feb 1981
Thomas T Meggitt B

A comparative study of methods for treating fractures of the distal half of the femur was carried out prospectively in the five-year period January 1973 to December 1977. The three methods compared were conservative treatment on a Thomas' splint, application of a knee-hinged cast-brace at five to seven weeks, and intramedullary nailing. The time in bed, in hospital and to union were compared as was the rate of functional recovery of the knee. It is concluded that the cast-brace provides a safe reliable method of treatment, combining the advantages of non-operative management with the early mobilisation possible with intramedullary fixation but without the disadvantages of surgical treatment


The Journal of Bone & Joint Surgery British Volume
Vol. 49-B, Issue 3 | Pages 571 - 579
1 Aug 1967
Emery MA Murakami H

1. Clinical studies in humans have indicated that a delay of one to three weeks in the open reduction of a fracture decreases the incidence of delayed union and non-union. 2. Studies in cats indicate that a delay of two weeks before open reduction causes a different repair mechanism from that following immediate operation. 3. Repair after delayed operation is characterised by increased periosteal new bone formation and more rapid endochondral bone formation. After immediate operation periosteal new bone is slow to develop; much more fibrous tissue and cartilage develop, followed by slow endochondral bone formation


The Journal of Bone & Joint Surgery British Volume
Vol. 68-B, Issue 5 | Pages 755 - 757
1 Nov 1986
Worlock P

A simple method of radiological assessment has been used to measure the angle between the long axis of the humeral shaft and the growth plate of the capitellum (the Baumann angle). In the normal arm a significant relationship was found between the Baumann angle and the carrying angle. The Baumann angle was also measured after reduction of supracondylar fractures of the humerus and was found to correlate well with the final carrying angle measured at follow-up. There was no significant difference between the Baumann angle after reduction and that measured at follow-up; and it is suggested that this angle after reduction can be reliably used to predict accurately the final carrying angle


The Journal of Bone & Joint Surgery British Volume
Vol. 67-B, Issue 4 | Pages 650 - 655
1 Aug 1985
Goodship A Kenwright J

Although it has been well established that fracture healing is influenced by the mechanical environment, the optimal parameters have not yet been established. In two groups of sheep an experimental tibial diaphysial fracture was created, and stabilised using external skeletal fixation. In one group rigid fixation was maintained throughout fracture healing; in the other group controlled axial micromovement, with a loading regime known to be osteogenic in intact bones, was applied for a short period daily. A significant improvement in healing was associated with the application of controlled micromovement. Data from these experiments provide the basis for improving the conditions for fracture healing and may assist in the prevention of delayed union


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 5 | Pages 799 - 803
1 Sep 1993
Braten M Terjesen T Rossvoll I

The torsion of both femora was evaluated in 110 patients who had been treated by intramedullary nailing for unilateral femoral shaft fractures. The anteversion (AV) angle was measured by ultrasound, using a tilted-transducer technique. True torsional deformity, defined as an AV difference of 15 degrees or more between sides was found in 21 patients, but only eight had complaints related to the deformity. Three patients had reoperations for troublesome external torsional deformities. Of 26 patients with AV differences of 10 degrees to 14 degrees, defined as possible torsional deformity, three had complaints, but none had serious problems. AV differences of up to 29 degrees were observed in symptom-free patients, and no patients with AV differences below 10 degrees had complaints. Static and dynamic nailing showed almost equal tendencies to lead to torsional deformity. We conclude that torsional deformities are usually established during the operation. Many patients tolerate abnormal torsion, but efforts should be made to reduce and stabilise the femoral shaft fracture with an AV difference of less than 15 degrees


The Journal of Bone & Joint Surgery British Volume
Vol. 64-B, Issue 4 | Pages 498 - 499
1 Aug 1982
Shakespeare D Henderson N

The effect of calcaneal traction on the compartmental pressure in the legs of five individuals with tibial fractures was studied. Mean resting pressures without traction were found to be 31.9 mmHg for the deep posterior compartment and 27.0 mmHg for the anterior compartment. For each kilogram weight of traction applied the deep posterior pressure rose by 5.7 per cent of the resting value and the anterior pressure by 1.6 per cent. It is suggested that the weight of traction should be only sufficient to render the patient comfortable and maintain alignment of the limb. Excessive traction is likely to increase the risk of compartmental ischaemia. The application of six kilograms of traction would raise the mean resting pressure by 34 per cent from 31.9 to 42.7 mmHg


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 4 | Pages 679 - 682
1 Jul 1991
Bostman O

We analysed the radiographs of 67 patients with displaced malleolar fractures treated by open reduction and internal fixation using absorbable polyglycolide rods. Seventeen patients developed a discharging inflammatory foreign-body reaction, a complication unique to these fixation devices. In 34 patients ovoid osteolytic foci, usually 5 to 10 mm in diameter, appeared within the implant channels six to 12 weeks after the operation. The same lesion occurred in 14 of the 17 patients who developed a foreign-body reaction, whereas only 20 out of the 50 patients with an uneventful course showed osteolytic areas (p less than 0.01). In patients with a foreign-body reaction the osteolytic foci tended to occur in the deepest parts of the implant channels. However, after one year the normal structure of the bone was restored


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 12 | Pages 1610 - 1612
1 Dec 2006
Al-Rashid M Theivendran K Craigen MAC

The use of volar locking compression plates for the treatment of fractures of the distal radius is becoming increasingly popular because of the stable biomechanical construct, less soft-tissue disturbance and early mobilisation of the wrist. A few studies have reported complications such as rupture of flexor tendons. We describe three cases of rupture of extensor tendons after the use of volar locking compression plates. We recommend extreme care when drilling and placing the distal radial screws to prevent damaging the extensor tendons