Risk of revision following total knee arthroplasty (TKA) is higher
in patients under 55 years, but little data are reported regarding
non-revision outcomes. This study aims to identify predictors of
dissatisfaction in these patients. We prospectively assessed 177 TKAs (157 consecutive patients,
99 women, mean age 50 years; 17 to 54) from 2008 to 2013. Age, gender,
implant, indication, body mass index (BMI), social deprivation,
range of movement, Kellgren-Lawrence (KL) grade of osteoarthritis
(OA) and prior knee surgery were recorded. Pre- and post-operative
Oxford Knee Score (OKS) as well as Short Form-12 physical (PCS)
and mental component scores were obtained. Post-operative range
of movement, complications and satisfaction were measured at one
year.Aims
Patients and Methods
The aims of the study were to review and analyse the reported
series of debridement, antibiotics and implant retention (DAIR)
in the management of infected total hip arthroplasties (THAs) to
establish the overall success and the influencing factors. Using a standardised recognised study protocol, meta-analysis
of observational studies in epidemiology guidelines, a comprehensive
review and analysis of the literature was performed. The primary
outcome measure was the success of treatment. The search strategy
and inclusion criteria which involved an assessment of quality yielded
39 articles for analysis, which included 1296 patients.Aims
Patients and methods
The Chevron osteotomy was described in 1976. There have, however, been only short- to mid-term follow-up reviews, often with small numbers of patients. We looked at 112 feet (73 patients) with a minimum follow-up of ten years following Chevron osteotomy with a distal soft-tissue procedure. Clinical evaluation was calculated using the hallux score of the American Orthopedic Foot and Ankle Society (AOFAS). For 47 feet (30 patients), the results were compared with those from an interim follow-up of 5.6 years. The AOFAS-score improved from a pre-operative mean of 46.5 points to a mean of 88.8 points after a mean of 12.7 years. The first metatarsophalangeal (MTP) angle showed a mean pre-operative value of 27.6° and was improved to 14.0°. The first intermetatarsal (IM) angle improved from a pre-operative mean value of 13.8° to 8.7°. The mean pre-operative grade of sesamoid subluxation was 1.7 on a scale from 0 to 3 and improved to 1.2. Measured on a scale from 0 to 3, arthritis of the first MTP joint progressed from a mean of 0.8 to 1.7. Comparing the results in patients younger and older than 50 years, the Chevron osteotomy performed equally in both age groups. Analysing the subgroup of 47 feet with a post-operative follow-up of both 5.6 and 12.7 years, the AOFAS pain and the overall score showed a further improvement between both follow-up evaluations. The MTP angle, first IM angle and sesamoid position remained unchanged. The progression of arthritis of the first MTP joint between 5.6 and 12.7 years post-operatively was statistically significant. Only one patient required a revision procedure due to painful recurrence of the deformity. Excellent clinical results following Chevron osteotomy not only proved to be consistent, but showed further improvement over a longer follow-up period. The mean
The goal of this study is to investigate the relation between indicators of osteoporosis (i.e., bone mineral density (BMD), and Cortical Index (CI)) and the complexity of a fracture of the proximal humerus as a result of a low-energy trauma. A retrospective chart review of 168 patients (mean age 67.2 years, range 51 to 88.7) with a fracture of the proximal humerus between 2007 and 2011, whose BMD was assessed at the Fracture Liaison Service with Dual Energy X-ray Absorptiometry (DXA) measurements of the hip, femoral neck (FN) and/or lumbar spine (LS), and whose CI and complexity of fracture were assessed on plain anteroposterior radiographs of the proximal humerus.Objectives
Methods
The primary aim of this independent prospective randomised trial
was to compare serum metal ion levels for ceramic-on-metal (CoM)
and metal-on-metal (MoM) bearing surfaces in total hip arthroplasty
(THA). Our one-year results demonstrated elevation in metal ion
levels above baseline with no significant difference between the
CoM and MoM groups. This paper reviews the five-year data. The implants used in each patient differed only in respect to
the type of femoral head (ceramic or metal). At five-year follow-up
of the 83 enrolled patients, data from 67 (36 CoM, 31 MoM) was available
for comparison.Aims
Patients and Methods
A few points in this report deserve to be stressed. Indications–It is important that the orthopaedic surgeon should decide at a very early stage which of the two methods, closed or open, he must use. These do not exclude each other but are on the other hand complementary. Nowadays the dislocated hip can be reduced by open operation with a very good chance of lasting success. This should be carried out if a hip cannot easily be reduced otherwise, or if there is any doubt that closed reduction has been successful–and as early as possible, preferably before the age of three years. Technique–Ample exposure of the joint and removal of all obstacles to reduction are important. Reduction must be complete and stable but without stress, and there must be no interference with the articular bone and cartilage. After-care–Reduction, however perfect, is only the first step towards recovery. The hip must be observed carefully and the most suitable moments for mobilisation and for walking must be chosen; this calls for nice judgment. When it is clear that the roof of the acetabulum is not developing or that persistent valgus and anteversion may encourage subluxation, a secondary operation should be undertaken at once.
The records of these patients show that restitution of joint function is quite possible even after severe disease. These results have been obtained by a combination of three methods, constitutional, antibiotic and operative. The duration of treatment averaged ten months and the patients were discharged to full activities in a short time without splints. There was one immediate failure in a child who received full, early and adequate treatment. There were two late relapses in patients treated early in the series whose operation was inadequate. The results were more variable in adults. If it is conceded that the triple treatment is valuable for patients with bone necrosis or severe synovial disease with pus in the joint, eight patients in this series remain who might have got better without operation. Two of these had had a synovial biopsy before admission. Whether the remaining six would have done as well without operation is a matter for speculation. It is difficult to assess the condition inside the joint solely by
1. In this series of thirty-eight cases of osteoclastoma, twenty-five occurred at the end of a long bone. Nineteen were in the lower limb and half tif these were near the knee joint; six were in the upper limb; of the remainder, nine occurred in the vertebrae or the sacrum. 2. More cases occurred in females than males, the ratio being twenty-three females to fifteen males. Just over half the cases occurred in the second and third decades. 3. In seven there was a definite history of injury preceding symptoms by several months. 4. It is often difficult to arrive at a diagnosis on clinical and
We carried out a further study of the long-term results of the
cemented Exeter femoral component in patients under the age of 40
with a mean follow-up of 13.6 years (10 to 20). We reviewed our original cohort of 104 cemented Exeter stems
in 78 consecutive patients with a mean age of 31 years (16 to 39).
Only one patient was lost to radiological follow-up.Aims
Patients and Methods
The aim of this study was to analyse the effect of altered viewing
perspectives on the measurement of the glenopolar angle (GPA) and
the differences between these measurements made on 3D CT reconstructions
and anteroposterior (AP) scapular view radiographs. The influence of the viewing perspective on the GPA was assessed,
as were the differences in the measurements of the GPA between 3D
CT reconstructions and AP scapular view radiographs in 68 cadaveric
scapulae.Aims
Materials and Methods
The Sliding Hip Screw (SHS) is commonly used to treat trochanteric hip fractures. Fixation failure is a devastating complication requiring complex revision surgery. One mode of fixation failure is lag screw cut-out which is greatest in unstable fracture patterns and when the tip-apex distance of the lag screw is > 25 mm. The X-Bolt Dynamic Hip Plating System (X-Bolt Orthopaedics, Dublin, Ireland) is a new device which aims to reduce this risk of cut-out. However, some surgeons have reported difficulty minimising the tip-apex distance with subsequent concerns that this may lead to an increased risk of cut-out. We measured the tip-apex distance from the intra-operative radiographs of 93 unstable trochanteric hip fractures enrolled in a randomised controlled trial (Warwick Hip Trauma Evaluation, WHiTE One trial). Participants were treated with either the sliding hip screw or the X-Bolt dynamic hip plating system. We also recorded the incidence of cut-out in both groups, at a median follow-up time of 17 months.Objectives
Patients and Methods
The aims of this study were to determine the proportion of patients
with outlier varus or valgus alignment in kinematically aligned
total knee arthroplasty (TKA), whether those with outlier varus
or valgus alignment have higher forces in the medial or lateral
compartments of the knee than those with in-range alignment and
whether measurements of the alignment of the limb, knee and components
predict compartment forces. The intra-operative forces in the medial and lateral compartments
were measured with an instrumented tibial insert in 67 patients
who underwent a kinematically aligned TKA during passive movement.
The mean of the forces at full extension, 45° and 90° of flexion
determined the force in the medial and lateral compartments. Measurements
of the alignment of the limb and the components included the hip-knee-ankle
(HKA) angle, proximal medial tibial angle (PMTA), and distal lateral
femoral angle (DLFA). Measurements of the alignment of the knee
and the components included the tibiofemoral angle (TFA), tibial
component angle (TCA) and femoral component angle (FCA). Alignment was
measured on post-operative, non-weight-bearing anteroposterior (AP)
scanograms and categorised as varus or valgus outlier or in-range
in relation to mechanically aligned criteria.Aims
Patients and Methods
Infection after intradiscal injections has been recognised as a distinct entity, but discitis after discography has often been attributed to an aseptic process or a chemical reaction to the contrast material. We examined the hypothesis that discitis after discography is always due to infection, and report a clinical review and an experimental study. Part I. We reviewed the case records and radiographs of 432 patients who had undergone lumbar discography. When an 18-gauge needle without a stilette had been used, discitis was diagnosed in 2.7% of 222 patients but stiletted needles and a two-needle technique at each level reduced the incidence to 0.7%. Seven patients with discitis after discography had undergone anterior discectomy and fusion; in them the histopathological findings were of a chronic inflammatory response. Bacteria were isolated from the discs of three of the four patients who had open biopsy less than six weeks from the time of discography. These findings suggest that bacteria were initiators rather than promoters of the response. Part II. Multiple level lumbar discography was carried out in mature sheep, injecting contrast material with or without various concentrations of bacteria.
This paper reports a new method for expressing numerically asymmetry of the contour of the back in a forward-bending position. Information is given at three spinal levels (T8, T12 and L3) for 636 schoolchildren aged 8 to 15 years. Rib-hump and lumbar-hump scores were standardised to create trunk asymmetry scores (TASs) making comparison possible between children of different age, size and sex. Two groups of children were defined: those with clinically straight spines (585 children); and those with clinical evidence of lateral spinal curves (51 children). In the children with clinically straight spines the main findings were: about 1:4 had objectively detectable rib and lumbar humps; female-to-male ratios were 1.2:1 for the thoracic region and 1.4:1 for the lumbar region; right humps were about 10 times more common than left; TASs in the boys and girls at each spinal level had normal distributions about means to the right of zero (where zero represents perfect symmetry); at T8 and T12, a wider scatter of TASs in girls than in boys; at L3, larger TASs in girls than in boys; a relation between shortening of one lower limb and a contralateral hump on the back; and no relation to age (except at L3), stature (corrected for age) or handedness. The findings are discussed in relation to possible causes of back contour asymmetry, early diagnosis of scoliosis by screening, sexual dimorphism and significance for the pathogenesis of idiopathic scoliosis. Ten children with clinically straight spines and larger TASs, and 42 out of 51 children with clinical evidence of lateral spinal curves in the forward-bending position attended for
1. One hundred patients with dislocation of the hip joint have been reviewed, many having been re-examined at intervals ranging from two to five years after injury. 2. There were forty-six simple dislocations, forty-three dislocations with fracture of the acetabular rim, seven dislocations with fracture of the acetabular floor, and five dislocations with fracture of the femoral head. 3. Complete recovery, as judged by clinical and
This review summarises the technique of impaction
grafting with mesh augmentation for the treatment of uncontained
acetabular defects in revision hip arthroplasty. The ideal acetabular revision should restore bone stock, use
a small socket in the near-anatomic position, and provide durable
fixation. Impaction bone grafting, which has been in use for over
40 years, offers the ability to achieve these goals in uncontained
defects. The precepts of modern, revision impaction grafting are
that the segmental or cavitary defects must be supported with a
mesh; the contained cavity is filled with vigorously impacted morselised
fresh-frozen allograft; and finally, acrylic cement is used to stabilise
the graft and provide rigid, long-lasting fixation of the revised
acetabular component. Favourable results have been published with this technique. While
having its limitations, it is a viable option to address large acetabular
defects in revision arthroplasty. Cite this article: