Advertisement for orthosearch.org.uk
Results 101 - 120 of 4189
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 9 | Pages 1285 - 1286
1 Sep 2011
Baker JF Vioreanu MH Khan HA

A variety of materials were used for early hip prostheses. The introduction of Vitallium by Smith-Petersen represented a further advance in this surgical field. We present the longest known follow-up of a Smith-Petersen Vitallium mould arthroplasty


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 4 | Pages 469 - 476
1 Apr 2010
Shimmin AJ Walter WL Esposito C

The survivorship of contemporary resurfacing arthroplasty of the hip using metal-on-metal bearings is better than that of first generation designs, but short-term failures still occur. The most common reasons for failure are fracture of the femoral neck, loosening of the component, osteonecrosis of the femoral head, reaction to metal debris and malpositioning of the component. In 2008 the Australian National Joint Registry reported an inverse relationship between the size of the head component and the risk of revision in resurfacing hip arthroplasty. Hips with a femoral component size of ≤ 44 mm have a fivefold increased risk of revision than those with femoral components of ≥ 55 mm irrespective of gender. We have reviewed the literature to explore this observation and to identify possible reasons including the design of the implant, loading of the femoral neck, the orientation of the component, the production of wear debris and the effects of metal ions, penetration of cement and vascularity of the femoral head. Our conclusion is that although multifactorial, the most important contributors to failure in resurfacing arthroplasty of the hip are likely to be the design and geometry of the component and the orientation of the acetabular component


Bone & Joint Research
Vol. 3, Issue 5 | Pages 146 - 149
1 May 2014
Jameson SS Baker PN Deehan DJ Port A Reed MR

The National Institute for Health and Clinical Excellence (NICE) has thus far relied on historical data and predominantly industry-sponsored trials to provide evidence for venous thromboembolic (VTE) prophylaxis in joint replacement patients. We argue that the NICE guidelines may be reliant on assumptions that are in need of revision. Following the publication of large scale, independent observational studies showing little difference between low-molecular-weight heparins and aspirin, and recent changes to the guidance provided by other international bodies, should NICE reconsider their recommendations?. Cite this article: Bone Joint Res 2014;3:146–9


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 5 | Pages 692 - 699
1 Jul 2002
Takwale VJ Nuttall D Trail IA Stanley JK

We have implanted 76 biaxial total wrist prostheses as a primary procedure in patients with rheumatoid arthritis of the wrist. A total of 66 was reviewed at a mean follow-up time of 52 months. Pain was relieved in 67% of the surviving wrist replacements. On the basis of the Hospital for Special Surgery scoring system, 49 wrists (74%) were graded as fair to excellent. More than half of the 27 patients who had an arthrodesis on the contralateral wrist would have preferred a second arthroplasty. Five replacements were revised or fused because of loosening and a further nine showed signs of radiological loosening, three of which were asymptomatic. The probability of survival of the biaxial total wrist replacement at eight years was 83% with revision surgery as the terminal event, 78% with radiological loosening as the endpoint and 82% with dorsal migration and displacement from the metacarpal as the terminal event. There was a linear relationship between subsidence of the component and distal loosening. There was no evidence that the length of the stem of the carpal component, within the third metacarpal, affected any of the terminal events. The position and alignment of the carpal component within the bone at the time of surgery significantly affect the outcome and can be used to predict failure


The Journal of Bone & Joint Surgery British Volume
Vol. 58-B, Issue 2 | Pages 227 - 229
1 May 1976
Dickson R Stein H Bentley G

The results of ten excision arthroplasties of the elbow for rheumatoid disease are described. The operation may afford good relief of pain and a useful increase both of hinge motion and of forearm rotation. Instability is not a serious problem unless the patient has to bear weight on crutches. To increase stability after arthroplasty it appears that Kirschner wire fixation is advisable as well as a plaster cast. For advanced rheumatoid disease unilateral excision arthroplasty has a definite value, especially for patients confined to a wheelchair


The Bone & Joint Journal
Vol. 96-B, Issue 12 | Pages 1663 - 1668
1 Dec 2014
Bottle A Aylin P Loeffler M

The aim of this study was to define return to theatre (RTT) rates for elective hip and knee replacement (HR and KR), to describe the predictors and to show the variations in risk-adjusted rates by surgical team and hospital using national English hospital administrative data. . We examined information on 260 206 HRs and 315 249 KRs undertaken between April 2007 and March 2012. The 90-day RTT rates were 2.1% for HR and 1.8% for KR. Male gender, obesity, diabetes and several other comorbidities were associated with higher odds for both index procedures. For HR, hip resurfacing had half the odds of cement fixation (OR = 0.58, 95% confidence intervals (CI) 0.47 to 0.71). For KR, unicondylar KR had half the odds of total replacement (OR = 0.49, 95% CI 0.42 to 0.56), and younger ages had higher odds (OR = 2.23, 95% CI 1.65 to 3.01) for ages < 40 years compared with ages 60 to 69 years). There were more funnel plot outliers at three standard deviations than would be expected if variation occurred on a random basis. . Hierarchical modelling showed that three-quarters of the variation between surgeons for HR and over half the variation between surgeons for KR are not explained by the hospital they operated at or by available patient factors. We conclude that 90-day RTT rate may be a useful quality indicator for orthopaedics. Cite this article: Bone Joint J 2014; 96-B:1663–8


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 3 | Pages 427 - 430
1 May 1999
Wroblewski BM Fleming PA Siney PD

We reviewed 261 patients with 320 Charnley low-friction arthroplasties who had a mean follow-up of 22 years 10 months (20 to 30). Of these, 93.9% considered the operation to be a success; 82.3% were free from pain and 11.6% had occasional discomfort. Satisfactory function was achieved in 59.6% and 62% had an excellent range of movement. The clinical results did not correlate well with the radiological appearance; radiologically loose components did not affect the clinical outcome. The main long-term problem was wear and loosening of the UHMWPE cup. Our findings suggest that the radiological appearance of the arthroplasty is a more reliable indication of the state of the arthroplasty than the clinical results


The Journal of Bone & Joint Surgery British Volume
Vol. 64-B, Issue 4 | Pages 465 - 468
1 Aug 1982
McDonald I

Twenty-six patients with rheumatoid arthritis who had undergone bilateral replacement of the hip and knee were reviewed at a mean follow-up time of 51.6 months. A further operation was necessary in five patients due to complications of replacement of the knee, and seven patients still had significant pain in at least one replaced joint. There were no cases of infection due to operation. Seventeen of the patients still used walking aids, but one-third of these did so because of pain in joints that had not been replaced. Patients preferred painless total replacement of the hip to that of the knee


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 8 | Pages 1120 - 1125
1 Aug 2012
Alazzawi S Bardakos NV Hadfield SG Butt U Beer ZH Field RE

Using general practitioner records and hospital notes and through direct telephone conversation with patients, we investigated the accuracy of nine patient-reported complications gathered from a self-completed questionnaire after elective joint replacement surgery of the hip and knee. A total of 402 post-discharge complications were reported after 8546 elective operations that were undertaken within a three-year period. These were reported by 136 men and 240 women with a mean age of 71.8 years (34 to 93). A total of 319 reported complications (79.4%; 95% confidence interval 75.4 to 83.3) were confirmed to be correct. High rates of correct reporting were demonstrated for infection (94.5%) and the need for further surgery (100%), whereas the rates of reporting deep-vein thrombosis (DVT), pulmonary embolism, myocardial infarction and stroke were lower (75% to 84.2%). Dislocation, peri-prosthetic fractures and nerve palsy had modest rates of correct reporting (36% to 57.1%). More patients who had knee surgery delivered incorrect reports of dislocation (p = 0.001) and DVT (p = 0.013). Despite these variations, it appears that post-operative complications may form part of a larger patient-reported outcome programme after elective joint replacement surgery


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 5 | Pages 787 - 792
1 Sep 1996
Wachtl SW Sennwald GR

We treated 43 patients (38 women and 5 men) with osteoarthritis of the basal joint of the thumb by non-cemented arthroplasty of the first carpometacarpal joint as described by Ledoux. The probability of a patient avoiding revision for 12 months was 62% and for 16 months 59%. The indications for revision were aseptic loosening in 83% and luxation in 17%. The surviving prostheses were reviewed clinically and radiologically at a mean follow-up of 25.3 months. Pain on loading, movement or at rest was seen in 75% of the patients. There was significant reduction in the range of movement of the trapeziometacarpal joint and of wrist strength. Radiological assessment showed significant subsidence of the stem in the first metacarpal and migration of the cup, with the stem loose in 15% and the cup in 46%. We no longer recommend this method of joint replacement


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 4 | Pages 436 - 441
1 Apr 2008
Steffen RT Pandit HP Palan J Beard DJ Gundle R McLardy-Smith P Murray DW Gill HS

Few independent studies have reported the outcome of resurfacing arthroplasty of the hip. The aim of this study was to report the five-year clinical outcome and seven-year survival of an independent series. A total of 610 Birmingham Hip Resurfacing arthroplasties were performed in 532 patients with a mean age of 51.8 years (16.5 to 81.6). They were followed for between two and eight years; 107 patients (120 hips) had been followed up for more than five years. Two patients were lost to follow-up. At a minimum of five years’ follow-up, 79 of 85 hips (93%) had an excellent or good outcome according to the Harris hip score. The mean Oxford hip score was 16.1 points (. sd. 7.7) and the mean University of California Los Angeles activity score was 6.6 points (. sd. 1.9). There were no patients with definite radiological evidence of loosening or of narrowing of the femoral neck exceeding 10% of its width. There were 23 revisions (3.8%), giving an overall survival of 95% (95% confidence interval 85.3 to 99.2) at seven years. Fractured neck of femur in 12 hips was the most common indication for revision, followed by aseptic loosening in four. In three hips (three patients) (0.5%), failure was possibly related to metal debris. Considering that these patients are young and active these results are good, and support the use of resurfacing. Further study is needed to address the early failures, particularly those related to fracture and metal debris


The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 5 | Pages 777 - 781
1 Nov 1989
Nilsson L Stromqvist B Thorngren K

We report a series of 640 consecutive cervical hip fractures which were followed prospectively for two years after primary internal fixation with two hook-pins. Secondary arthroplasties were performed as salvage procedures in 75 cases and the early outcome of these was studied retrospectively. The mean time in hospital was 25 days for prosthetic replacement, though 60% of the patients had other medical conditions considered as risk factors. Mortality was 5% after six months and 8% after one year. Dislocation was seen in 11% and additional surgery was required in 4%. There was one case of deep infection and one supracondylar femoral fracture. In some cases there was considerable delay between the primary and secondary operation due to lack of awareness of functional deterioration, but although many patients had poor mobility before the secondary operation this was greatly improved within six weeks of the arthroplasty. We conclude that elective secondary hip arthroplasty for failure of fracture fixation is a safe and successful procedure. Once the decision to perform an arthroplasty is taken, this should be done without delay to avoid deterioration of function


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 12 | Pages 1632 - 1637
1 Dec 2007
Myers GJC Abudu AT Carter SR Tillman RM Grimer RJ

We have investigated whether improvements in design have altered the outcome for patients undergoing endoprosthetic replacement of the proximal tibia following resection of a tumour. Survival of the implant and ‘servicing’ procedures have been documented using a prospective database. A total of 194 patients underwent a proximal tibial replacement, with 95 having a fixed-hinge design and 99 a rotating-hinge with a hydroxyapatite collar; their median age was 21.5 years (10 to 74). At a mean follow-up of 14.7 years (5 to 29), 115 patients remain alive. The risk of revision for any reason in the fixed-hinge group was 32% at five years, 61% at ten years and 75% at 15 and 20 years, and in the rotating-hinge group 12% at five years, 25% at ten years and 30% at 15 years. Aseptic loosening was the most common reason for revision in the fixed-hinge knees, fracture of the implant in the early design of rotating hinges and infection in the current version. The risk of revision for aseptic loosening in the fixed-hinge knees was 46% at ten years. This was reduced to 3% in the rotating-hinge knee with a hydroxyapatite collar. The cemented, rotating hinge design currently offers the best chance of long-term survival of the prosthesis


The Journal of Bone & Joint Surgery British Volume
Vol. 51-B, Issue 4 | Pages 638 - 647
1 Nov 1969
Apley AG Millner WF Porter DS

1. A total of 120 Moore's arthroplasties in 111 patients were reviewed one to nine years after operation. 2. There was striking reduction in the severity of pain in 105 out of the 120 hips reviewed. Range of movement was improved in most patients but the degree of independence was improved less often. The reasons for this are discussed. 3. We draw the following conclusions regarding the place of Moore's arthroplasty. Firstly, it was a natural step in the evolution towards total hip replacement, an operation which promises to give more complete relief of symptoms and which seems likely to replace Moore's arthroplasty as the treatment of choice in osteoarthritis of the hip in the elderly. Secondly, Moore's arthroplasty is still a rational procedure for the treatment of degeneration if the acetabulum is not involved—for instance, in idiopathic avascular necrosis of the femoral head. Thirdly, it is certainly a valuable operation for some cases of recent fracture of the femoral neck. Avascular necrosis of the femoral head after trifin nailing can be satisfactorily treated by Moore's arthroplasty, particularly in the early stages before the acetabulum becomes involved. Finally, Moore's arthroplasty gave many fairly elderly patients considerable relief of pain at a time when nothing better was available. Much of the relief afforded has proved to be lasting, but deterioration sometimes occurred with time. In the few patients whose deterioration amounted to failure a definite cause for the failure was found. In the majority the deterioration was slight, and it seems likely that the operation will last most of these elderly patients for the rest of their lives


The Bone & Joint Journal
Vol. 98-B, Issue 10_Supple_B | Pages 28 - 33
1 Oct 2016
Lum ZC Lombardi AV Hurst JM Morris MJ Adams JB Berend KR

Aims. Since redesign of the Oxford phase III mobile-bearing unicompartmental knee arthroplasty (UKA) femoral component to a twin-peg design, there has not been a direct comparison to total knee arthroplasty (TKA). Thus, we explored differences between the two cohorts. Patients and Methods . A total of 168 patients (201 knees) underwent medial UKA with the Oxford Partial Knee Twin-Peg. These patients were compared with a randomly selected group of 177 patients (189 knees) with primary Vanguard TKA. Patient demographics, Knee Society (KS) scores and range of movement (ROM) were compared between the two cohorts. Additionally, revision, re-operation and manipulation under anaesthesia rates were analysed. Results. The mean follow-up for UKA and TKA groups was 5.4 and 5.5 years, respectively. Six TKA (3.2%) versus three UKAs (1.5%) were revised which was not significant (p = 0.269). Manipulation was more frequent after TKA (16; 8.5%) versus none in the UKA group (p <  0.001). UKA patients had higher post-operative KS function scores versus TKA patients (78 versus 66, p < 0.001) with a trend toward greater improvement, but there was no difference in ROM and KS clinical improvement (p = 0.382 and 0.420, respectively). Conclusion. We found fewer manipulations, and higher functional outcomes for patients treated with medial mobile-bearing UKA compared with TKA. TKA had twice the revision rate as UKA although this did not reach statistical significance with the numbers available. . Cite this article: Bone Joint J 2016;98-B(10 Suppl B):28–33


The Journal of Bone & Joint Surgery British Volume
Vol. 63-B, Issue 2 | Pages 219 - 224
1 May 1981
Dobbs H Scales J Wilson J Kemp H Burrows H Sneath R

A series of 81 patients has been reviewed to determine the value of endoprosthetic replacement of the proximal femur and hip in the treatment of bone tumours. Standard statistical methods were used to evaluate the survival of the replacements and the patients. Taking removal of the prosthesis, irrespective of the cause, as the criterion for failure the survival of the replacements was found to be 63 per cent after 10 years. If deaths are regarded as failures, then the survival value falls to 48 per cent. The survival of patients with chondrosarcoma and osteoclastoma treated by endoprosthetic replacement compares favourably with survival after amputation or excision of the tumour


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 1 | Pages 75 - 81
1 Jan 2009
Cil A Veillette CJH Sanchez-Sotelo J Sperling JW Schleck C Cofield RH

Between 1976 and 2004, 38 revision arthroplasties (35 patients) were performed for aseptic loosening of the humeral component. The mean interval from primary arthroplasty to revision was 7.1 years (0.4 to 16.6). A total of 35 shoulders (32 patients) were available for review at a mean follow-up of seven years (2 to 19.3). Pre-operatively, 34 patients (97%) had moderate or severe pain; at final follow-up, 29 (83%) had no or only mild pain (p < 0.0001). The mean active abduction improved from 88° to 107° (p < 0.01); and the mean external rotation from 37° to 46° (p = 0.27). Excellent or satisfactory results were achieved in 25 patients (71%) according to the modified Neer rating system. Humeral components were cemented in 29, with ingrowth implants used in nine cases. There were 19 of standard length and 17 were longer (two were custom replacements and are not included). Bone grafting was required for defects in 11 humeri. Only two glenoid components were left unrevised. Intra-operative complications included cement extrusion in eight cases, fracture of the shaft of the humerus is two and of the tuberosity in four. There were four re-operations, one for recurrent humeral loosening, with 89% survival free of re-operations at ten years. Revision surgery for aseptic loosening of the humeral component provides reliable pain relief and modest improvement of movement, although there is a substantial risk of intra-operative complications. Revision to a total shoulder replacement gives better results than to a hemiarthroplasty


The Bone & Joint Journal
Vol. 95-B, Issue 11 | Pages 1480 - 1483
1 Nov 2013
Hooper GJ Gilchrist N Maxwell R March R Heard A Frampton C

We studied the bone mineral density (BMD) and the bone mineral content (BMC) of the proximal tibia in patients with a well-functioning uncemented Oxford medial compartment arthroplasty using the Lunar iDXA bone densitometer. Our hypothesis was that there would be decreased BMD and BMC adjacent to the tibial base plate and increased BMD and BMC at the tip of the keel. There were 79 consecutive patients (33 men, 46 women) with a mean age of 65 years (44 to 84) with a minimum two-year follow-up (mean 2.6 years (2.0 to 5.0)) after unilateral arthroplasty, who were scanned using a validated standard protocol where seven regions of interest (ROI) were examined and compared with the contralateral normal knee. All had well-functioning knees with a mean Oxford knee score of 43 (14 to 48) and mean Knee Society function score of 90 (20 to 100), showing a correlation with the increasing scores and higher BMC and BMD values in ROI 2 in the non-implanted knee relative to the implanted knee (p = 0.013 and p = 0.015, respectively). The absolute and percentage changes in BMD and BMC were decreased in all ROIs in the implanted knee compared with the non-implanted knee, but this did not reach statistical significance. Bone loss was markedly less than reported losses with total knee replacement. There was no significant association with side, although there was a tendency for the BMC to decrease with age in men. The BMC was less in the implanted side relative to the non-implanted side in men compared with women in ROI 2 (p = 0.027), ROI 3 (p = 0.049) and ROI 4 (p = 0.029). The uncemented Oxford medial compartment arthroplasty appears to allow relative preservation of the BMC and BMD of the proximal tibia, suggesting that the implant acts more physiologically than total knee replacement. Peri-prosthetic bone loss is an important factor in assessing long-term implant stability and survival, and the results of this study are encouraging for the long-term outcome of this arthroplasty. Cite this article: Bone Joint J 2013;95-B:1480–3


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 9 | Pages 1133 - 1134
1 Sep 2007
Haddad FS Ashby E Konangamparambath S

Due to economic constraints, it has been suggested that joint replacement patients can be followed up in primary care. There are clinical, ethical and academic reasons why we must ensure that our joint replacements are appropriately clinically and radiologically followed up to minimise complications. This Editorial discusses this


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 6 | Pages 1003 - 1007
1 Nov 1997
Oka M Chang Y Nakamura T Ushio K Toguchida J Gu H

We have studied damage to the tibial articular surface after replacement of the femoral surface in dogs. We inserted pairs of implants made of alumina, titanium and polyvinyl alcohol (PVA) hydrogel on titanium fibre mesh into the femoral condyles. The two hard materials caused marked pathological changes in the articular cartilage and menisci, but the hydrogel composite replacement caused minimal damage. The composite osteochondral device became rapidly attached to host bone by ingrowth into the supporting mesh. We discuss the clinical implications of the possible use of this material in articular resurfacing and joint replacement