A new technique for the treatment of displaced fractures of the proximal humerus is described. Twelve fractures in 11 patients were managed by transcutaneous reduction using a Steinmann pin, and external fixation with a Hoffmann-type neutralising bar connected to two half-pins in the
Ultrasound (US) was used to determine the congruity of the shoulder in 22 children with a deformity of the shoulder secondary to chronic obstetric brachial plexus palsy. There were 11 boys and 11 girls with a mean age of 4.75 years (0.83 to 13.92). The shoulder was scanned in the axial plane using a posterior approach with the arm internally rotated. The
We studied five cadaver shoulders to determine the strength relationship of the four rotator cuff muscles. The mean fibre length and volume of each muscle were measured, from which the physiological cross-sectional area was calculated. This value was used to estimate the force which each muscle was capable of generating. The lever arm of each muscle about the
We describe 11 cases of posterior fracture-dislocation of the shoulder that required open reduction and fixation. Difficulties with access through anterior approaches led us to use the superior subacromial approach. This is an extension of the approach often used to expose the rotator cuff; the joint is opened by splitting the supraspinatus tendon 5 mm behind the cuff interval. The glenoid, proximal humerus and any fracture fragments can be seen from above, allowing reduction of the dislocation and osteosynthesis to be performed with minimal risk of damage to the
Open reduction and internal fixation was employed in the treatment of 25 severely displaced fractures and fracture-dislocations of the proximal humerus. Our aims were accurate reduction and stable fixation to allow early mobilisation and to achieve full functional recovery. In 15 fractures an AO T-plate was used and in 10 a bent semitubular plate was employed as a blade plate. Excellent or satisfactory results were obtained in all six patients with two-part fractures involving the surgical neck; in four of the five patients with three-part fractures involving the surgical neck and tuberosities; in nine of the 11 patients with fracture-dislocation; and in two of the three patients with split fractures of the
We reviewed eight children (ten shoulders) who had suffered neonatal sepsis, after a mean follow-up of 14 years (11 to 15). The delay between the onset of symptoms and diagnosis was one day in five patients, two days in three and seven days in one. All ten shoulders were treated by aspiration, followed by arthrotomy in two. At follow-up, five of the ten shoulders had a full range of movement and the others had minimal restriction of external rotation. Shortening of 10 cm was present in one patient, while two with bilateral involvement had disproportionally short humeri. Early diagnosis and treatment favour the outcome in septic arthritis of the shoulder. With late diagnosis, deformation of the
We treated 12 shoulders in ten patients with irreparable rotator-cuff tears by transfer of the latissimus dorsi. There were nine men and one woman. Their average age was 64.0 years and the average follow-up was 35.6 months (26 to 42). The results were excellent in four shoulders, good in four, fair in one, and poor in three. Active forward flexion improved from a preoperative average of 99° to a postoperative average of 135°. Osteoarthritic changes appeared in five shoulders and proximal migration of the
1. Six cases of posterior dislocation of the shoulder are described. 2. In four cases the diagnosis was made on clinical grounds. 3. The important clinical signs are the adducted and medially rotated position of the arm, a hard mass posteriorly below the acromion representing the displaced
The operative treatment of fractures of the proximal humerus can be complicated by poor bone quality. Our aim was to evaluate a new method which allows prediction of the bone quality of the proximal humerus from radiographs. Anteroposterior radiographs were taken of 19 human cadaver humeri. The cortical thickness was measured at two levels of the proximal humeral diaphysis. The bone mineral density (BMD) was determined for the
We examined macroscopically and microscopically 55 cadaver rotator-cuff tendons attached to their
We performed a prospective study using MRI in 16 consecutive infants with a mean age of 5.2 months (2.7 to 8.7) who had shown inadequate recovery from an obstetric lesion of the brachial plexus in the first three months of life, in order to identify early secondary deformities of the shoulder. Shoulders were analysed according to a standardised MRI protocol. Measurements were made of the appearance of the glenoid, glenoid version and the position of the
Ninety-five patients with steroid-induced avascular necrosis of bone have been personally treated by the author. Of these, eighteen had a lesion of the head of the humerus, on one or both sides. The conditions for which the steroids were given included post-transplantation, lupus erythematosus, glomerulonephritis and asthma. The characteristic lesion began as a subchondral osteolytic area which frequently progressed to collapse. The articular cartilage divided from the subchondral bone, either becoming detached as a free cap or at a later stage reattaching. In some cases the lesion was minimal and the symptoms were slight. Conservative treatment has consisted of pendulum exercises and avoidance of abduction, particularly against resistance. In fourteen patients this led to satisfactory function with only intermittent symptoms. Four patients required replacement of five
The purpose of this paper is to call attention to the anterior bone block method of Hybbinette-Eden for recurrent dislocation of the shoulder joint. 1. The operative technique is not difficult, and the after-treatment is short and relatively agreeable for the patient. 2. Sixty of our own cases are described, with four recurrences. The recurrences all occurred as the result of real trauma. In a total of 128 Scandinavian cases there were eight recurrencesâthat is 6·3 per cent. 3. In our opinion, based on the observations of radiography, arthrography, and operation, it is the compression fracture of the head of the humerus which deserves the name "essential lesion." Destruction of the anterior rim of the glenoid may be very slight, or entirely lacking. No false joint cavity or rupture big enough to receive the head of the humerus was ever observed by arthrography or by inspection during operative exploration. Recurrent dislocation is an intracapsular subluxation, which occurs when the anterior rim of the glenoid slides into the hollow in the
The stabilising effects on the glenohumeral joint of each of the rotator-cuff muscles and of the biceps were studied with the arm in abduction and external rotation in 13 cadaver shoulders. The muscles were loaded one at a time with forces proportional to their cross-sectional areas. We recorded the positions of the
1. A study of 2,200 patients receiving electro-convulsive therapy showed that fifty-three sustained fractures or dislocationsâan incidence of 2·4 per cent. Of the fifty-three injuries, twenty-one occurred in the spine, fifteen in the neck of femur, fifteen in the upper end of humerus, one in the coracoid process; one dislocated jaw required anaesthesia for its reduction (other cases of transient dislocation of the jaw are excluded). 2. The incidence, site, and type of spinal fractures are recorded, and the relation of the fracture to the first convulsion is noted. No late changes were found in the spines of patients examined two years or more after treatment. A neutral position of the spine during the convulsion is believed to diminish the risk of fracture. 3. Fracture of the neck of the femur is a serious injury in these patients. In one case the injury was bilateral. 4. The fifteen cases of fracture-dislocation of the upper humerus are analysed. They included two cases of posterior dislocation of the
The Mathys Affinis Short is the most frequently used stemless total shoulder prosthesis in the UK. The purpose of this prospective cohort study is to report the survivorship, clinical, and radiological outcomes of the first independent series of the Affinis Short prosthesis. From January 2011 to January 2019, a total of 141 Affinis Short prostheses were implanted in 127 patients by a single surgeon. Mean age at time of surgery was 68 (44 to 89). Minimum one year and maximum eight year follow-up (mean 3.7 years) was analyzed using the Oxford Shoulder Score (OSS) at latest follow-up. Kaplan-Meier survivorship analysis was performed with implant revision as the endpoint. Most recently performed radiographs were reviewed for component radiolucent lines (RLLs) and proximal humeral migration.Aims
Methods
To report early (two-year) postoperative findings from a randomized controlled trial (RCT) investigating disease-specific quality of life (QOL), clinical, patient-reported, and radiological outcomes in patients undergoing a total shoulder arthroplasty (TSA) with a second-generation uncemented trabecular metal (TM) glenoid versus a cemented polyethylene glenoid (POLY) component. Five fellowship-trained surgeons from three centres participated. Patients aged between 18 and 79 years with a primary diagnosis of glenohumeral osteoarthritis were screened for eligibility. Patients were randomized intraoperatively to either a TM or POLY glenoid component. Study intervals were: baseline, six weeks, six-, 12-, and 24 months postoperatively. The primary outcome was the Western Ontario Osteoarthritis Shoulder QOL score. Radiological images were reviewed for metal debris. Mixed effects repeated measures analysis of variance for within and between group comparisons were performed.Aims
Methods
Reverse total shoulder arthroplasty (RTSA) using trabecular metal (TM)-backed glenoid implants has been introduced with the aim to increase implant survival. Only short-term reports on the outcomes of TM-RTSA have been published to date. We aim to present the seven-year survival of TM-backed glenoid implants along with minimum five-year clinical and radiological outcomes. All consecutive elective RTSAs performed at a single centre between November 2008 and October 2014 were reviewed. Patients who had primary TM-RTSA for rotator cuff arthropathy and osteoarthritis with deficient cuff were included. A total of 190 shoulders in 168 patients (41 male, 127 female) were identified for inclusion at a mean of 7.27 years (SD 1.4) from surgery. The primary outcome was survival of the implant with all-cause revision and aseptic glenoid loosening as endpoints. Secondary outcomes were clinical, radiological, and patient-related outcomes with a five-year minimum follow-up.Aims
Methods
The amount of glenoid bone loss is an important factor in deciding between soft-tissue and bony reconstruction when managing anterior shoulder instability. Accurate and reproducible measurement of glenoid bone loss is therefore vital in evaluation of shoulder instability and recommending specific treatment. The aim of this systematic review is to identify the range methods and measurement techniques employed in clinical studies treating glenoid bone loss. A systematic review of the PubMed, MEDLINE, and Embase databases was undertaken to cover a ten-year period from February 2011 to February 2021. We identified clinical studies that incorporated bone loss assessment in the methodology as part of the decision-making in the management of patients with anterior shoulder instability. The Preferred Reporting Items for Systematic Reviews (PRISMA) were used.Aims
Methods