Advertisement for orthosearch.org.uk
Results 101 - 120 of 405
Results per page:
Bone & Joint Open
Vol. 2, Issue 9 | Pages 696 - 704
1 Sep 2021
Malhotra R Gautam D Gupta S Eachempati KK

Aims

Total hip arthroplasty (THA) in patients with post-polio residual paralysis (PPRP) is challenging. Despite relief in pain after THA, pre-existing muscle imbalance and altered gait may cause persistence of difficulty in walking. The associated soft tissue contractures not only imbalances the pelvis, but also poses the risk of dislocation, accelerated polyethylene liner wear, and early loosening.

Methods

In all, ten hips in ten patients with PPRP with fixed pelvic obliquity who underwent THA as per an algorithmic approach in two centres from January 2014 to March 2018 were followed-up for a minimum of two years (2 to 6). All patients required one or more additional soft tissue procedures in a pre-determined sequence to correct the pelvic obliquity. All were invited for the latest clinical and radiological assessment.


Bone & Joint Open
Vol. 2, Issue 7 | Pages 503 - 508
8 Jul 2021
Callaghan CJ McKinley JC

Aims

Arthroplasty has become increasingly popular to treat end-stage ankle arthritis. Iatrogenic posterior neurovascular and tendinous injury have been described from saw cuts. However, it is hypothesized that posterior ankle structures could be damaged by inserting tibial guide pins too deeply and be a potential cause of residual hindfoot pain.

Methods

The preparation steps for ankle arthroplasty were performed using the Infinity total ankle system in five right-sided cadaveric ankles. All tibial guide pins were intentionally inserted past the posterior tibial cortex for assessment. All posterior ankles were subsequently dissected, with the primary endpoint being the presence of direct contact between the structure and pin.


The Bone & Joint Journal
Vol. 103-B, Issue 2 | Pages 299 - 304
1 Feb 2021
Goto E Umeda H Otsubo M Teranishi T

Aims

Various surgical techniques have been described for total hip arthroplasty (THA) in patients with Crowe type III dislocated hips, who have a large acetabular bone defect. The aim of this study was to evaluate the long-term clinical results of patients in whom anatomical reconstruction of the acetabulum was performed using a cemented acetabular component and autologous bone graft from the femoral neck.

Methods

A total of 22 patients with Crowe type III dislocated hips underwent 28 THAs using bone graft from the femoral neck between 1979 and 2000. A Charnley cemented acetabular component was placed at the level of the true acetabulum after preparation with bone grafting. All patients were female with a mean age at the time of surgery of 54 years (35 to 68). A total of 18 patients (21 THAs) were followed for a mean of 27.2 years (20 to 33) after the operation.


Bone & Joint Research
Vol. 10, Issue 7 | Pages 425 - 436
16 Jul 2021
Frommer A Roedl R Gosheger G Hasselmann J Fuest C Toporowski G Laufer A Tretow H Schulze M Vogt B

Aims

This study aims to enhance understanding of clinical and radiological consequences and involved mechanisms that led to corrosion of the Precice Stryde (Stryde) intramedullary lengthening nail in the post market surveillance era of the device. Between 2018 and 2021 more than 2,000 Stryde nails have been implanted worldwide. However, the outcome of treatment with the Stryde system is insufficiently reported.

Methods

This is a retrospective single-centre study analyzing outcome of 57 consecutive lengthening procedures performed with the Stryde nail at the authors’ institution from February 2019 until November 2020. Macro- and microscopic metallographic analysis of four retrieved nails was conducted. To investigate observed corrosion at telescoping junction, scanning electron microscopy (SEM) and energy dispersive x-ray spectroscopy (EDX) were performed.


The Journal of Bone & Joint Surgery British Volume
Vol. 68-B, Issue 3 | Pages 476 - 477
1 May 1986
Jones D

Partridge bands have been developed and marketed on the assumption that their ribbed under-surface would ensure less interference with periosteal and cortical blood flow than other cerclage systems. Three cases are reported of serious clinical complications from loss of cortical bone under the band, and interference with the external bridging callus response


The Bone & Joint Journal
Vol. 103-B, Issue 6 Supple A | Pages 165 - 170
1 Jun 2021
Larson DJ Rosenberg JH Lawlor MA Garvin KL Hartman CW Lyden E Konigsberg BS

Aims

Stemmed tibial components are frequently used in revision total knee arthroplasty (TKA). The purpose of this study was to evaluate patient satisfaction, overall pain, and diaphyseal tibial pain in patients who underwent revision TKA with cemented or uncemented stemmed tibial components.

Methods

This is a retrospective cohort study involving 110 patients with revision TKA with cemented versus uncemented stemmed tibial components. Patients who underwent revision TKA with stemmed tibial components over a 15-year period at a single institution with at least two-year follow-up were assessed. Pain was evaluated through postal surveys. There were 63 patients with cemented tibial stems and 47 with uncemented stems. Radiographs and Knee Society Scores were used to evaluate for objective findings associated with pain or patient dissatisfaction. Postal surveys were analyzed using Fisher’s exact test and the independent-samples t-test. Logistic regression was used to adjust for age, sex, and preoperative bone loss.


Bone & Joint Research
Vol. 10, Issue 2 | Pages 113 - 121
1 Feb 2021
Nicholson JA Oliver WM MacGillivray TJ Robinson CM Simpson AHRW

Aims

To evaluate if union of clavicle fractures can be predicted at six weeks post-injury by the presence of bridging callus on ultrasound.

Methods

Adult patients managed nonoperatively with a displaced mid-shaft clavicle were recruited prospectively. Ultrasound evaluation of the fracture was undertaken to determine if sonographic bridging callus was present. Clinical risk factors at six weeks were used to stratify patients at high risk of nonunion with a combination of Quick Disabilities of the Arm, Shoulder and Hand questionnaire (QuickDASH) ≥ 40, fracture movement on examination, or absence of callus on radiograph.


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 5 | Pages 693 - 696
1 Sep 1993
Ling R Timperley A Linder L

We report the histology of a femur retrieved 3.5 years after a cemented revision of a hip replacement in which impaction allografting had been used to fill two large cortical defects. The allograft chips had largely been replaced by viable cortical bone, and the interface between cement and tissue resembled that seen after primary cemented arthroplasty


The Journal of Bone & Joint Surgery British Volume
Vol. 63-B, Issue 2 | Pages 233 - 238
1 May 1981
Dickenson R Hutton W Stott

Specimens of femoral cortical bone from normal subjects and from patients with osteoporosis were mechanically tested in tension to destruction. The osteoporotic bone showed less strength and less stiffness than the normal bone; these reductions are related to the increased cavity area in osteoporosis. Further, the osteoporotic bone is not able to absorb as much energy before fracture as the normal bone; but this difference is not related to changes in cavity area


The Journal of Bone & Joint Surgery British Volume
Vol. 62-B, Issue 1 | Pages 43 - 45
1 Feb 1980
Lindholm T Osterman K

Two patients with osteochondritis dissecans of the hip were operated on and their case histories are presented. The relatively large foci were situated on the weight-bearing surface of the joint and the fragments were fixed using transplants of cortical bone. In both cases the focus healed, and the symptoms were relieved. At follow-up six and nine years later respectively, the clinical results were good and no signs of osteoarthritis had as yet developed


The Journal of Bone & Joint Surgery British Volume
Vol. 52-B, Issue 2 | Pages 366 - 370
1 May 1970
Jit I Chawla LS Chhuttani PN

1. Fluorotic bones and exostoses obtained from the skeletons of two subjects with advanced fluorosis have been examined microscopically. 2. The cortical bone showed normal, regular Haversian systems with normal canaliculi and lacunae. The exostoses also exhibited normal, regular Haversian systems but at places the reabsorption tunnels were large. 3. Special stains failed to show osteoid tissue either in the fluorotic bones or in their exostoses


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 11 | Pages 1430 - 1437
1 Nov 2006
Michalak KA Khoo PPC Yates PJ Day RE Wood DJ

Revision arthroplasty after infection can often be complicated by both extensive bone loss and a relatively high rate of re-infection. Using allograft to address the bone loss in such patients is controversial because of the perceived risk of bacterial infection from the use of avascular graft material. We describe 12 two-stage revisions for infection in which segmental allografts were loaded with antibiotics using iontophoresis, a technique using an electrical potential to drive ionised antibiotics into cortical bone. Iontophoresis produced high levels of antibiotic in the allograft, which eluted into the surrounding tissues. We postulate that this offers protection from infection in the high-risk peri-operative period. None of the 12 patients who had two-stage revision with iontophoresed allografts had further infection after a mean period of 47 months (14 to 78)


The Journal of Bone & Joint Surgery British Volume
Vol. 59-B, Issue 2 | Pages 200 - 205
1 May 1977
Elson R Jephcott A McGechie D Verettas D

Laboratory experiments and clinical investigations have confirmed the various claims made originally by Buchholz and Engelbrecht (1970) that antibiotic-loaded acrylic cement releases the antibiotic into the surroundings in useful concentrations. Palacos R cement released higher concentrations than CMW, Simplex and Sulfix brands of cement and over longer periods. Concentrations of gentamycin and fucidin were sufficient to penetrate dead cortical bone. These conclusions need to be assessed with animal studies, mechanical testing and clinical results before the ideal place of antibiotic-loaded acrylic cement is established


The Journal of Bone & Joint Surgery British Volume
Vol. 51-B, Issue 2 | Pages 300 - 306
1 May 1969
Henry A

1. Monostotic fibrous dysplasia in the long bones occurs most frequently in adolescence. In the jaws it is found mainly in early adult life. It presents later in the ribs, probably because it is often asymptomatic in this site. 2. The disease is equally distributed in both sexes. 3. Reactivation may occasionally occur in later life and in pregnancy. 4. Successful surgical treatment is by no means always easily achieved, and requires, in addition to the problems of fracture fixation and the correction of deformity, careful consideration of the age of the patient, the activity of the lesion and the extent to which it involves the cortical bone


The Journal of Bone & Joint Surgery British Volume
Vol. 39-B, Issue 4 | Pages 738 - 741
1 Nov 1957
Nicholson OR

1. "Reed" osteotomy has proved a satisfactory method for the correction of torsional deformity of the tibia and of associated minor varus or valgus deformity. 2. It is an "osteotomy in continuity" and maintains stability of the bone. 3. The position of the limb may be adjusted at the first change of plaster. 4. Three cases of non-union occurred in thirty-eight operations. 5. The operation should not be done on adults. Perhaps it may be wise to reserve it for even younger patients because its success depends on the pliability of cortical bone, which rapidly diminishes with increasing age


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 3 | Pages 492 - 497
1 May 1991
Sugimoto M Takahashi S Toguchida J Kotoura Y Shibamoto Y Yamamuro T

We studied the effects of high-dose irradiation on the mechanical properties and morphology of cortical bone in rabbits for 52 weeks after a single dose of 50 Gy of electron-beam to the tibia. After four weeks, the bending strength of the irradiated bone was unchanged, but at 12 weeks, the strength had decreased significantly. At 24 weeks after irradiation mean strength was less than half of controls but by 52 weeks there was a tendency toward recovery. Similar, synchronous changes of damage and recovery were seen in cortical porosity, haematopoietic cells in the bone marrow and endosteal new bone formation


The Journal of Bone & Joint Surgery British Volume
Vol. 68-B, Issue 5 | Pages 804 - 807
1 Nov 1986
Harrison D

Free osteocutaneous fibular grafts, revascularised by microvascular anastomoses, have been used for one-stage reconstruction of extensive bone and skin loss in the lower leg in seven patients. The addition of an integral skin flap to a vascularised fibular graft makes reconstruction of bone defects with significant skin loss possible, and the technique for designing and raising such a flap is presented. The advantages of this transfer over other microvascular osteocutaneous flaps are the available length of straight cortical bone, the large thin skin flap, the good diameter of the vascular pedicle and the fact that dissection is carried out under a tourniquet


Bone & Joint Research
Vol. 10, Issue 1 | Pages 51 - 59
1 Jan 2021
Li J Ho WTP Liu C Chow SK Ip M Yu J Wong HS Cheung W Sung JJY Wong RMY

Aims

The effect of the gut microbiota (GM) and its metabolite on bone health is termed the gut-bone axis. Multiple studies have elucidated the mechanisms but findings vary greatly. A systematic review was performed to analyze current animal models and explore the effect of GM on bone.

Methods

Literature search was performed on PubMed and Embase databases. Information on the types and strains of animals, induction of osteoporosis, intervention strategies, determination of GM, assessment on bone mineral density (BMD) and bone quality, and key findings were extracted.


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 3 | Pages 506 - 508
1 May 1991
Ryan M

Intramedullary rods manufactured from polyacetal were used to fix diaphyseal fractures in osteoporotic bone. They are pliable and can be introduced without further damage to such bone. Their low elastic modulus induces abundant callus. They can be locked with cortical bone screws without the need of jigs or radiographic control. Nine femoral and five tibial fractures were fixed in 10 patients, all with osteoporosis; 13 united primarily; one required bone grafting. No implant broke; however, no ambulant patient weighed more than 75 kg. The rods offer a promising treatment for diaphyseal fractures in osteoporotic bone


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 3 | Pages 391 - 394
1 May 1990
Strachan R McCarthy I Fleming R Hughes S

There has been a long-standing debate as to whether medullary or periosteal flow is the dominant vascular supply during the healing of diaphyseal fractures. We used radioactive microspheres to quantify blood flow to the canine tibia two weeks after an osteotomy. There was a significant contribution from the periosteum to the blood supply of healing cortical bone after nutrient artery ligation, with a reversal of flow from a centrifugal to a centripetal direction. Our study has confirmed the qualitative observations of Trueta (1974) regarding the significant recruitment of vessels from surrounding soft tissue during fracture healing. We have not studied the later stages of healing