Advertisement for orthosearch.org.uk
Results 101 - 120 of 2655
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 7 | Pages 893 - 898
1 Jul 2008
Levy O Relwani J Zaman T Even T Venkateswaran B Copeland S

The aim of this study was to define the microcirculation of the normal rotator cuff during arthroscopic surgery and investigate whether it is altered in diseased cuff tissue. Blood flow was measured intra-operatively by laser Doppler flowmetry. We investigated six different zones of each rotator cuff during the arthroscopic examination of 56 consecutive patients undergoing investigation for impingement, cuff tears or instability; there were 336 measurements overall. The mean laser Doppler flowmetry flux was significantly higher at the edges of the tear in torn cuffs (43.1, 95% confidence interval (CI) 37.8 to 48.4) compared with normal cuffs (32.8, 95% CI 27.4 to 38.1; p = 0.0089). It was significantly lower across all anatomical locations in cuffs with impingement (25.4, 95% CI 22.4 to 28.5) compared with normal cuffs (p = 0.0196), and significantly lower in cuffs with impingement compared with torn cuffs (p < 0.0001). Laser Doppler flowmetry analysis of the rotator cuff blood supply indicated a significant difference between the vascularity of the normal and the pathological rotator cuff. We were unable to demonstrate a functional hypoperfusion area or so-called ‘critical zone’ in the normal cuff. The measured flux decreases with advancing impingement, but there is a substantial increase at the edges of rotator cuff tears. This might reflect an attempt at repair


The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 2 | Pages 301 - 305
1 Mar 1987
Styf J Korner L Suurkula M

In nine patients with chronic compartment syndrome, the intramuscular pressure and muscle blood flow during constant dynamic exercise was studied by the microcapillary infusion method and by the 133-xenon clearance technique. Although muscle blood flow was normal at the start of exercise, pain and impaired muscle function eventually developed; muscle blood flow decreased while muscle relaxation pressure increased. The changes of muscle blood flow could not be correlated with any change of mean muscle pressure during exercise. Eight months after fasciotomy the exercise test was repeated. Patients experienced no symptoms and the muscle relaxation pressure and blood flow during exercise were normal. It is suggested that chronic compartment syndrome is due to increased muscle relaxation pressure during exercise which causes decreased muscle blood flow, leading to ischaemic pain and impaired muscle function


The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 2 | Pages 272 - 274
1 Mar 1989
Jozsa L Balint J Kannus P Reffy A Barzo M

We aimed to determine the distribution of the ABO and Rh blood groups in 832 patients with a tendon rupture. Among these, the frequency of blood group O (52.8%) was significantly higher than in the general population of Hungary (31.1%) and the frequency of group A was significantly lower. Of the 83 cases of multiple ruptures or re-rupture, 57 patients (68.7%) had group O blood. The dominance of group O was found for all sites of tendon rupture, but there was no significant association with the Rh groups. Individuals with blood group O appear to have an increased risk of tendon rupture


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 2 | Pages 174 - 177
1 Mar 2003
Jeserschek R Clar H Aigner C Rehak P Primus B Windhager R

We have investigated in a prospective, randomised placebo-controlled study the effect of high-dose aprotinin on blood loss in patients admitted for major surgery (revision arthroplasty of the hip or knee, or for resection of a soft-tissue sarcoma). The mean intraoperative blood loss was reduced from 1957 ml in the control group to 736 ml in the aprotinin group (p = 0.002). The mean requirement for intraoperative homologous blood transfusion in the aprotinin group was 1.4 units (95% CI 0.2 to 2.7) and 3.1 units (95% CI 1.7 to 4.6) in the control group (p = 0.033). The mean length of hospital stay was reduced from 27.8 days in the control group to 17.6 days in the aprotinin group which was not statistically significant. The intraoperative use of aprotinin in major orthopaedic operations significantly reduced blood loss and the required amount of packed cells. It may result in a decrease in the length of hospital stay and costs


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 10 | Pages 1298 - 1303
1 Oct 2008
Grose AW Gardner MJ Sussmann PS Helfet DL Lorich DG

The inferior gluteal artery is described in standard anatomy textbooks as contributing to the blood supply of the hip through an anastomosis with the medial femoral circumflex artery. The site(s) of the anastomosis has not been described previously. We undertook an injection study to define the anastomotic connections between these two arteries and to determine whether the inferior gluteal artery could supply the lateral epiphyseal arteries alone. From eight fresh-frozen cadaver pelvic specimens we were able to inject the vessels in 14 hips with latex moulding compound through either the medial femoral circumflex artery or the inferior gluteal artery. Injected vessels around the hip were then carefully exposed and documented photographically. In seven of the eight specimens a clear anastomosis was shown between the two arteries adjacent to the tendon of obturator externus. The terminal vessel arising from this anastomosis was noted to pass directly beneath the posterior capsule of the hip before ascending the superior aspect of the femoral neck and terminating in the lateral epiphyseal vessels. At no point was the terminal vessel found between the capsule and the conjoined tendon. The medial femoral circumflex artery receives a direct supply from the inferior gluteal artery immediately before passing beneath the capsule of the hip. Detailed knowledge of this anatomy may help to explain the development of avascular necrosis after hip trauma, as well as to allow additional safe surgical exposure of the femoral neck and head


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 5 | Pages 676 - 679
1 Jul 2001
Bae H Westrich GH Sculco TP Salvati EA Reich LM

We have assessed the effect of the donation of autologous blood and the preoperative level of haemoglobin on the prevalence of postoperative thromboembolism in 2043 patients who had a total hip arthroplasty. The level of haemoglobin was determined seven to ten days before surgery and all patients had venography of the operated leg on the fifth postoperative day. The number of patients who had donated autologous blood (1037) was similar to that who had not (1006). A significant decrease in the incidence of deep-vein thrombosis (DVT) was noted in those who had donated blood preoperatively (9.0%) compared with those who had not (13.5%) (p = 0.003). For all patients, the lower the preoperative level of haemoglobin the less likely it was that a postoperative DVT would develop. Of those who had donated blood, 0.3% developed a postoperative pulmonary embolism compared with 0.7% in those who had not, but this difference was not statistically significant. No significant difference was found in the requirements for transfusion between the two groups


Aims. The aim of this study was to examine the efficacy and safety of multiple boluses of intravenous (IV) tranexamic acid (TXA) on the hidden blood loss (HBL) and inflammatory response following primary total hip arthroplasty (THA). Patients and Methods. A total of 150 patients were allocated randomly to receive a single bolus of 20 mg/kg IV TXA before the incision (group A), a single bolus followed by a second bolus of 1 g IV-TXA three hours later (group B) or a single bolus followed by two boluses of 1 g IV-TXA three and six hours later (group C). All patients were treated using a standard peri-operative enhanced recovery protocol. Primary outcomes were HBL and the level of haemoglobin (Hb) as well as the levels of C-reactive protein (CRP) and interleukin-6 (IL-6) as markers of inflammation. Secondary outcomes included the length of stay in hospital and the incidence of venous thromboembolism (VTE). Results. The mean HBL was significantly lower in group C (402.13 ml standard deviation (. sd). 225.97) than group A (679.28 ml. sd. 277.16, p < 0.001) or B (560.62 ml . sd. 295.22, p = 0.010). The decrease in the level of Hb between the pre-operative baseline and the level on the third post-operative day was 30.82 g/L (. sd. 6.31 g/L) in group A, 27.16 g/L (. sd. 6.83) in group B and 21.98 g/L (. sd. 3.72) in group C. This decrease differed significantly among the three groups (p < 0.01). The mean level of CRP was significantly lower in group C than in the other two groups on the second (p ≤ 0.034) and third post-operative days (p ≤ 0.014). The levels of IL-6 were significantly lower in group C than group A on the first three post-operative days (p = 0.023). The mean length of stay was significantly lower in group C than group A (p = 0.023). No VTE or other adverse events occurred. Conclusion. Multiple boluses of IV-TXA can effectively reduce HBL following primary THA. A regime of three boluses leads to a smaller decrease in the level of Hb, less post-operative inflammation and a shorter length of stay in hospital than a single bolus. Cite this article: Bone Joint J 2017;99-B:1442–9


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 5 | Pages 748 - 754
1 Jul 2000
Case CP Langkamer VG Lock RJ Perry MJ Palmer MR Kemp AJ

We compared the peripheral blood and periprosthetic tissues of 53 patients at revision arthroplasty with those of 30 patients at primary arthroplasty to determine whether there is a systemic difference in lymphocytes in patients with worn hip implants. The absolute number and relative proportion of lymphocytes bearing CD2, CD3, CD4, CD8, CD16, CD19, HLA-DR, kappa and lambda antigens were compared with the levels of IL-1β, IL-6 and PGE. 2. in the pseudosynovial membrane as well as with a semiquantitative estimate of metal and polyethylene particles, necrosis and chronic inflammation and the total concentration of metals within the periprosthetic tissues. There was a significant increase in the relative proportion of CD2-positive T-cells and CD16-positive natural killer cells in the peripheral blood at revision arthroplasty compared with primary arthroplasty and an increased proportion of CD8-positive T-cells and a decreased ratio of CD4 to CD8 (helper inducer/suppressor cytotoxic cells). Three control patients, who went on to have revision surgery, had values at primary arthroplasty which were similar to those of patients at the time of revision surgery. These differences did not correlate with the local concentration of metal, plastic or cement or inflammatory response or the type of prosthesis. An inverse correlation was noted between the necrosis in the periprosthetic tissue and both the local production of IL-6 and the absolute numbers of T-cells in peripheral blood. We conclude that there may be several cell-mediated systemic immune responses to aseptic loosening, at least one of which may be directly related to events in the periprosthetic tissues. We cannot exclude the possibility that the changes in the proportion of CD8-positive cells reflected a predisposition, rather than a reaction, to loosening of the implant


The Journal of Bone & Joint Surgery British Volume
Vol. 52-B, Issue 1 | Pages 160 - 167
1 Feb 1970
Mulfinger GL Trueta J

1. The intraosseous and extraosseous circulation of the talus was examined in thirty necropsy specimens. 2. The blood supply to the talus is quite diffuse and arises from the three major arteries of the lower leg. 3. The common patterns of circulation, as well as the variations, have been documented


The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 1 | Pages 100 - 101
1 Jan 1989
Carr A Norris S

The microvascular anatomy of the calcaneal tendon was investigated in cadaver tendons by injection of barium sulphate and indian ink and a quantitative study of intratendinous blood supply was made, using a computer-assisted image analysis system. There was a reduction in both the number and the mean relative area of vessels in the mid-section of the tendon. This area of reduced vascularity may be of significance in the pathogenesis of rupture


The Bone & Joint Journal
Vol. 95-B, Issue 5 | Pages 616 - 622
1 May 2013
Horstmann WG Swierstra MJ Ohanis D Castelein RM Kollen BJ Verheyen CCPM

Autologous retransfusion and no-drainage are both blood-saving measures in total hip replacement (THR). A new combined intra- and post-operative autotransfusion filter system has been developed especially for primary THR, and we conducted a randomised controlled blinded study comparing this with no-drainage. A total of 204 THR patients were randomised to autologous blood transfusion (ABT) (n = 102) or no-drainage (n = 102). In the ABT group, a mean of 488 ml (. sd. 252) of blood was retransfused. The mean lowest post-operative haemoglobin level during the hospital stay was higher in the autotransfusion group (10.6 g/dl (7.8 to 13.9) vs 10.2 g/dl (7.5 to 13.3); p = 0.01). The mean haemoglobin levels for the ABT and no-drainage groups were not significantly different on the first day (11.3 g/dl (7.8 to 13.9) vs 11.0 g/dl (8.1 to 13.4); p = 0.07), the second day (11.1 g/dl (8.2 to 13.8) vs 10.8 g/dl (7.5 to 13.3); p = 0.09) or the third day (10.8 g/dl (8.0 to 13.0) vs 10.6 g/dl (7.5 to 14.1); p = 0.15). The mean total peri-operative net blood loss was 1464 ml (. sd. 505) in the ABT group and 1654 ml (. sd. 553) in the no-drainage group (p = 0.01). Homologous blood transfusions were needed in four patients (3.9%) in the ABT group and nine (8.8%) in the no-drainage group (p = 0.15). No statistically significant difference in adverse events was found between the groups. The use of a new intra- and post-operative autologous blood transfusion filter system results in less total blood loss and a smaller maximum decrease in haemoglobin levels than no-drainage following primary THR. Cite this article: Bone Joint J 2013;95-B:616–22


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 3 | Pages 392 - 398
1 Apr 2000
Atsumi T Yamano K Muraki M Yoshihara S Kajihara T

We performed superselective angiography in 28 hips in 25 patients with Perthes’ disease in order to study the blood supply of the lateral epiphyseal arteries (LEAs). Interruption of the LEAs at their origin was observed in 19 hips (68%). Revascularisation in the form of numerous small arteries was seen in ten out of 11 hips in the initial stage of Perthes’ disease, in seven of eight in the fragmentation stage and in five of nine in the healing stage. Penetration of mature arteries into the depths of the epiphysis was seen in four of nine hips in the healing stage. Vascular penetration was absent in the weight-bearing portion of the femoral head below the acetabular roof. Interruption of the posterior column artery was seen where it passed through the capsule in seven hips when they lay either in internal rotation or in abduction with internal rotation. We suggest that in Perthes’ disease the blood supply of the LEAs is impaired at their origin and that revascularisation occurs from this site by ingrowth of small vessels into the femoral epiphysis. This process may be the result of recurrent ischaemic episodes


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 3 | Pages 490 - 493
1 May 1995
Reichert I McCarthy I Hughes S

The tibial nutrient artery supplies 62% of cortical blood flow in the diaphysis and normal blood flow is centrifugal (Willans 1987). Intramedullary reaming destroys the nutrient artery and injures the endosteal surface of the cortex. Trueta (1974) suggested that the direction of blood flow can reverse from centrifugal to centripetal after loss of the endosteal supply. We examined this hypothesis by measuring cortical and periosteal blood flow after intramedullary reaming of the tibia in eight sheep, using 57Co radiolabelled microspheres. The unreamed contralateral tibiae served as a control group. Thirty minutes after reaming there was no significant change in cortical blood flow, but a sixfold increase in the periosteal flow. Our study confirms Trueta's hypothesis; after trauma or in other pathological states, flow can become centripetal


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 5 | Pages 770 - 771
1 Sep 1990
Twyman R Kirwan T Fennelly M

We measured the blood loss during and after hip replacement in two groups of women, each consisting of 10 patients. In one group the lumbar plexus was infiltrated with bupivacaine, in the other it was not. The group in whom the plexus was blocked had significantly less blood loss


The Journal of Bone & Joint Surgery British Volume
Vol. 38-B, Issue 4 | Pages 928 - 933
1 Nov 1956
Lewis OJ

1. Periosteal bone is supplied by periosteal vessels and endochondral bone by the nutrient artery. 2. In the earliest stages of development the metaphysis is supplied by vessels derived only from the nutrient artery. Later, metaphysial arteries derived from the periosteum take over the supply of its peripheral part, the extent of their area of supply progressively increasing. 3. In injected specimens the blood vessels approaching the epiphysial cartilaginous plate end in saccular dilations. Histological sections show these dilations to be blood-filled cartilage lacunae, with no endothelial lining and into which open the blood vessels approaching the epiphysial plate


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 10 | Pages 1293 - 1298
1 Oct 2007
Steffen R O’Rourke K Gill HS Murray DW

In 12 patients, we measured the oxygen concentration in the femoral head-neck junction during hip resurfacing through the anterolateral approach. This was compared with previous measurements made for the posterior approach. For the anterolateral approach, the oxygen concentration was found to be highly dependent upon the position of the leg, which was adjusted during surgery to provide exposure to the acetabulum and femoral head. Gross external rotation of the hip gave a significant decrease in oxygenation of the femoral head. Straightening the limb led to recovery in oxygen concentration, indicating that the blood supply was maintained. The oxygen concentration at the end of the procedure was not significantly different from that at the start. The anterolateral approach appears to produce less disruption to the blood flow in the femoral head-neck junction than the posterior approach for patients undergoing hip resurfacing. This may be reflected subsequently in a lower incidence of fracture of the femoral neck and avascular necrosis


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 2 | Pages 274 - 277
1 Mar 2001
Drescher W Schneider T Becker C Hobolth J Rüther W Hansen ES Bünger C

Treatment with corticosteroids is a risk factor for non-traumatic avascular necrosis of the femoral head, but the pathological mechanism is poorly understood. Short-term treatment with high doses of methylprednisolone is used in severe neurotrauma and after kidney and heart transplantation. We investigated the effect of such treatment on the pattern of perfusion of the femoral head and of bone in general in the pig. We allocated 15 immature pigs to treatment with high-dose methylprednisolone (20 mg/kg per day intramuscularly for three days, followed by 10 mg/kg intramuscularly for a further 11 days) and 15 to a control group. Perfusion of the systematically subdivided femoral head, proximal femur, acetabulum, humerus, and soft tissues was determined by the microsphere technique. Blood flow in bone was severely reduced in the steroid-treated group. The reduction of flow affected all the segments and the entire epiphysis of the femoral head. No changes in flow were found in non-osseous tissue. Short-term treatment with high-dose methylprednisolone causes reduction of osseous blood flow which may be the pathogenetic factor in the early stage of steroid-induced osteonecrosis


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 6 | Pages 809 - 814
1 Aug 2001
Dawson JS Martel AL Davis TRC

We have investigated whether assessment of blood flow to the proximal scaphoid can be used to predict nonunion in acute fractures of the scaphoid. We studied 32 fractures of the scaphoid one to two weeks after injury, by dynamic fat-suppressed T1-weighted gradient-echo MRI after the intravenous administration of gadopentetate dimeglumine (0.1 mmol/kg body-weight). Steepest slope values (SSV) and percentage enhancement values (%E) were calculated for the distal and proximal fragments and poles. All the fractures were treated by immobilisation in a cast, and union was assessed by CT at 12 weeks. Nonunion occurred in four fractures (12%), and there was no statistically significant difference between the proximal fragment SSV and %E values for the fractures which united and those with nonunion. The difference between the proximal pole SSV and %E values for the union and nonunion groups reached statistical significance (p < 0.05), but with higher enhancement parameters for the nonunion group. Our results suggest that poor proximal vascularity is not an important determinant of union in fractures of the scaphoid


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 5 | Pages 702 - 705
1 Jul 2001
Tanaka N Sakahashi H Sato E Hirose K Ishima T Ishii S

We studied 99 patients who were undergoing total knee arthroplasty (TKA) to determine the optimum protocol for the administration of tranexamic acid (TNA) in order to reduce blood loss. It decreased by more than 40% after the administration of TNA. The haemostatic effect was greatest when TNA was given preoperatively and on deflation of the tourniquet. There was no increase in the incidence of adverse affects in the patients receiving TNA, compared with a control group. We conclude that two injections of TNA, one given preoperatively and one on deflation of the tourniquet, significantly reduce blood loss without increasing the risk of thromboembolic complications


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 1 | Pages 73 - 75
1 Jan 1991
Harper W Barnes M Gregg P

We studied 50 patients with fractures of the femoral neck, 33 intracapsular and 17 extracapsular. Intraosseous pressure was measured by a transducer within the bone to quantify blood flow, and intracapsular pressure by a needle introduced into the joint space. The mean intracapsular pressure was lower in the extracapsular fractures. In these, the mean intraosseous pressure in the femoral head was unchanged by aspiration of the joint. However in the intracapsular fractures aspiration produced a significant decrease in intra-osseous pressure and an increase in pulse pressure within the femoral head. The results suggest that aspiration of intracapsular haematoma produced an increase in femoral head blood flow by relieving tamponade