header advert
Results 101 - 120 of 171
Results per page:
The Bone & Joint Journal
Vol. 101-B, Issue 7 | Pages 852 - 859
1 Jul 2019
Reigstad O Holm-Glad T Korslund J Grimsgaard C Thorkildsen R Røkkum M

Aims

Plate and screw fixation has been the standard treatment for painful conditions of the wrist in non-rheumatoid patients in recent decades. We investigated the complications, re-operations, and final outcome in a consecutive series of patients who underwent wrist arthrodesis for non-inflammatory arthritis.

Patients and Methods

A total of 76 patients, including 53 men and 23 women, with a mean age of 50 years (21 to 79) underwent wrist arthrodesis. Complications and re-operations were recorded. At a mean follow-up of 11 years (2 to 18), 63 patients completed questionnaires, and 57 attended for clinical and radiological assessment.


Bone & Joint 360
Vol. 7, Issue 5 | Pages 18 - 21
1 Oct 2018


Bone & Joint 360
Vol. 8, Issue 6 | Pages 22 - 26
1 Dec 2019


Bone & Joint 360
Vol. 8, Issue 1 | Pages 21 - 24
1 Feb 2019


Bone & Joint 360
Vol. 6, Issue 6 | Pages 22 - 24
1 Dec 2017


Bone & Joint 360
Vol. 7, Issue 1 | Pages 20 - 22
1 Feb 2018


The Bone & Joint Journal
Vol. 101-B, Issue 2 | Pages 170 - 177
1 Feb 2019
Puri A Gulia A Hegde P Verma V Rekhi B

Aims

The aims of this study were to evaluate the efficacy of preoperative denosumab in achieving prospectively decided intention of therapy in operable giant cell tumour of bone (GCTB) patients, and to document local recurrence-free survival (LRFS).

Patients and Methods

A total of 44 patients received preoperative denosumab: 22 to facilitate curettage, 16 to facilitate resection, and six with intent of converting resection to curettage. There were 26 male and 18 female patients. The mean age was 27 years (13 to 47).


The Bone & Joint Journal
Vol. 97-B, Issue 11 | Pages 1533 - 1538
1 Nov 2015
Zhang X Shao X Huang W Zhu H Yu Y

We report a new surgical technique for the treatment of traumatic dislocation of the carpometacarpal (CMC) joint of the thumb. This is a tenodesis which uses part of the flexor carpi radialis.

Between January 2010 and August 2013, 13 patients with traumatic instability of the CMC joint of the thumb were treated using this technique. The mean time interval between injury and ligament reconstruction was 13 days (0 to 42). The mean age of the patients at surgery was 38 years: all were male.

At a mean final follow-up of 26 months (24 to 29), no patient experienced any residual instability. The mean total palmar abduction of the CMC joint of the thumb was 61° and the mean radial abduction 65° The mean measurements for the uninjured hand were 66° (60° to 73°) and 68° (60° to 75°), respectively. The mean Kapandji thumb opposition score was 8.5° (8° to 9°). The mean pinch and grip strengths of the hand were 6.7 kg (3.4 to 8.2) and 40 kg (25 to 49), respectively. The mean Disabilities of the Arm, Shoulder, and Hand questionnaire score was 3 (1 to 6). Based on the Smith and Cooney score, we obtained a mean score of 85 (75 to 95), which included four excellent, seven good, and two fair results.

Our technique offers an alternative method of treating traumatic dislocation of the CMC joint of the thumb: it produces a stable joint and acceptable hand function.

Cite this article: Bone Joint J 2015;97-B:1533–8.


The Bone & Joint Journal
Vol. 99-B, Issue 4 | Pages 503 - 507
1 Apr 2017
White TO Mackenzie SP Carter TH Jefferies JG Prescott OR Duckworth AD Keating JF

Aims

Fracture clinics are often characterised by the referral of large numbers of unselected patients with minor injuries not requiring investigation or intervention, long waiting times and recurrent unnecessary reviews. Our experience had been of an unsustainable system and we implemented a ‘Trauma Triage Clinic’ (TTC) in order to rationalise and regulate access to our fracture service. The British Orthopaedic Association’s guidelines have required a prospective evaluation of this change of practice, and we report our experience and results.

Patients and Methods

We review the management of all 12 069 patients referred to our service in the calendar year 2014, with a minimum of one year follow-up during the calendar year 2015.


Bone & Joint 360
Vol. 7, Issue 5 | Pages 28 - 30
1 Oct 2018


The Bone & Joint Journal
Vol. 100-B, Issue 11 | Pages 1416 - 1423
1 Nov 2018
Rajan PV Qudsi RA Dyer GSM Losina E

Aims

The aim of this study was to assess the quality and scope of the current cost-effectiveness analysis (CEA) literature in the field of hand and upper limb orthopaedic surgery.

Materials and Methods

We conducted a systematic review of MEDLINE and the CEA Registry to identify CEAs that were conducted on or after 1 January 1997, that studied a procedure pertaining to the field of hand and upper extremity surgery, that were clinical studies, and that reported outcomes in terms of quality-adjusted life-years. We identified a total of 33 studies that met our inclusion criteria. The quality of these studies was assessed using the Quality of Health Economic Analysis (QHES) scale.


Bone & Joint 360
Vol. 5, Issue 6 | Pages 26 - 27
1 Dec 2016


Bone & Joint Research
Vol. 4, Issue 11 | Pages 176 - 180
1 Nov 2015
Mirghasemi SA Rashidinia S Sadeghi MS Talebizadeh M Rahimi N

Objectives

There are various pin-in-plaster methods for treating fractures of the distal radius. The purpose of this study is to introduce a modified technique of ‘pin in plaster’.

Methods

Fifty-four patients with fractures of the distal radius were followed for one year post-operatively. Patients were excluded if they had type B fractures according to AO classification, multiple injuries or pathological fractures, and were treated more than seven days after injury. Range of movement and functional results were evaluated at three and six months and one and two years post-operatively. Radiographic parameters including radial inclination, tilt, and height, were measured pre- and post-operatively.


Bone & Joint 360
Vol. 7, Issue 2 | Pages 20 - 23
1 Apr 2018


Bone & Joint Research
Vol. 7, Issue 6 | Pages 406 - 413
1 Jun 2018
Shabestari M Kise NJ Landin MA Sesseng S Hellund JC Reseland JE Eriksen EF Haugen IK

Objectives

Little is known about tissue changes underlying bone marrow lesions (BMLs) in non-weight-bearing joints with osteoarthritis (OA). Our aim was to characterize BMLs in OA of the hand using dynamic histomorphometry. We therefore quantified bone turnover and angiogenesis in subchondral bone at the base of the thumb, and compared the findings with control bone from hip OA.

Methods

Patients with OA at the base of the thumb, or the hip, underwent preoperative MRI to assess BMLs, and tetracycline labelling to determine bone turnover. Three groups were compared: trapezium bones removed by trapeziectomy from patients with thumb base OA (n = 20); femoral heads with (n = 24); and those without (n = 9) BMLs obtained from patients with hip OA who underwent total hip arthroplasty.


The Bone & Joint Journal
Vol. 98-B, Issue 12 | Pages 1642 - 1647
1 Dec 2016
Badge R Kailash K Dickson DR Mahalingam S Raza A Birch A Nuttall D Murali SR Hayton MJ Talwalkar S Watts AC Trail IA

Aims

The aims of this study were to evaluate the clinical and radiological outcomes of the Universal-2 total wrist arthroplasty (TWA) in patients with rheumatoid arthritis.

Patients and Methods

This was a retrospective review of all 95 Universal-2 TWAs which were performed in our institution between 2003 to 2012 in patients with rheumatoid arthritis. A total of six patients were lost to follow-up and two died of unrelated causes. A total of ten patients had bilateral procedures. Accordingly, 75 patients (85 TWAs) were included in the study. There were 59 women and 16 men with a mean age of 59 years (26 to 86). The mean follow-up was 53 months (24 to 120). Clinical assessment involved recording pain on a visual analogue score, range of movement, grip strength, the Quick Disabilities of the Arm, Shoulder and Hand (DASH) and Wrightington wrist scores. Any adverse effects were documented with particular emphasis on residual pain, limitation of movement, infection, dislocation and the need for revision surgery.

Radiographic assessment was performed pre-operatively and at three, six and 12 months post-operatively, and annually thereafter. Arthroplasties were assessed for distal row intercarpal fusion and loosening. Radiolucent zones around the components were documented according to a system developed at our institution.


Bone & Joint 360
Vol. 5, Issue 3 | Pages 17 - 19
1 Jun 2016


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11 | Pages 1540 - 1545
1 Nov 2012
Reigstad O Lütken T Grimsgaard C Bolstad B Thorkildsen R Røkkum M

The Motec cementless modular metal-on-metal ball-and-socket wrist arthroplasty was implanted in 16 wrists with scaphoid nonunion advanced collapse (SNAC; grades 3 or 4) and 14 wrists with scapholunate advanced collapse (SLAC) in 30 patients (20 men) with severe (grades 3 or 4) post-traumatic osteoarthritis of the wrist. The mean age of the patients was 52 years (31 to 71). All prostheses integrated well radiologically. At a mean follow-up of 3.2 years (1.1 to 6.1) no luxation or implant breakage occurred. Two wrists were converted to an arthrodesis for persistent pain. Loosening occurred in one further wrist at five years post-operatively. The remainder demonstrated close bone–implant contact. The clinical results were good, with markedly decreased Disabilities of the Arm Shoulder and Hand (DASH) and pain scores, and increased movement and grip strength. No patient used analgesics and most had returned to work.

Good short-term function was achieved using this wrist arthroplasty in a high-demand group of patients with post-traumatic osteoarthritis.


The Bone & Joint Journal
Vol. 95-B, Issue 10 | Pages 1383 - 1387
1 Oct 2013
Lanting BA Ferreira LM Johnson JA Athwal GS King GJW

We measured the tension in the interosseous membrane in six cadaveric forearms using an in vitro forearm testing system with the native radial head, after excision of the radial head and after metallic radial head replacement. The tension almost doubled after excision of the radial head during simulated rotation of the forearm (p = 0.007). There was no significant difference in tension in the interosseous membrane between the native and radial head replacement states (p = 0.09). Maximal tension occurred in neutral rotation with both the native and the replaced radial head, but in pronation if the radial head was excised. Under an increasing axial load and with the forearm in a fixed position, the rate of increase in tension in the interosseous membrane was greater when the radial head was excised than for the native radial head or replacement states (p = 0.02). As there was no difference in tension between the native and radial head replacement states, a radial head replacement should provide a normal healing environment for the interosseous membrane after injury or following its reconstruction. Load sharing between the radius and ulna becomes normal after radial head Replacement. As excision of the radial head significantly increased the tension in the interosseous membrane it may potentially lead to its attritional failure over time.

Cite this article: Bone Joint J 2013;95-B:1383–7.


Bone & Joint 360
Vol. 6, Issue 3 | Pages 19 - 21
1 Jun 2017