Advertisement for orthosearch.org.uk
Results 101 - 120 of 355
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 5 | Pages 789 - 793
1 Sep 1993
Radford P Needoff M Webb J

We made a randomised prospective comparison of the Dynamic Hip Screw and the Gamma locking nail for the internal fixation of 200 petrochanteric femoral fractures in elderly patients. There was less intraoperative blood loss and a lower rate of wound complications in the patients treated by the Gamma nail. They had, however, a high incidence of femoral shaft fracture which we relate in part to implant design. We do not recommend the use of the Gamma nail for these fractures


The Journal of Bone & Joint Surgery British Volume
Vol. 67-B, Issue 5 | Pages 732 - 735
1 Nov 1985
Milgrom C Giladi M Stein M Kashtan H Margulies J Chisin R Steinberg R Aharonson Z

In a prospective study of 295 male Israeli military recruits a 31% incidence of stress fractures was found. Eighty per cent of the fractures were in the tibial or femoral shaft, while only 8% occurred in the tarsus and metatarsus. Sixty-nine per cent of the femoral stress fractures were asymptomatic, but only 8% of those in the tibia. Even asymptomatic stress fractures do, however, need to be treated. Possible explanations for the unusually high incidence of stress fractures in this study are discussed


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 3 | Pages 386 - 389
1 May 1988
Cooke P Newman J

We have reviewed the results of treating 75 fractures of the proximal femoral shaft in the presence of a cemented femoral prosthesis. A simple radiographic classification into four types is proposed, and suggestions are made on the appropriate management of each. Comminuted fractures around the implant need early revision, whilst spiral fractures in this region may be treated conservatively or by operation. Transverse fractures at the level of the tip of the prosthesis are difficult to manage, and may require open reduction and internal fixation


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 3 | Pages 450 - 452
1 May 1990
Newington D Bannister G Fordyce M

We have reviewed 107 patients of 80 years or over who underwent primary total hip replacement. They had many more complications than younger patients. Thus, acute dislocation occurred in 15%, and became chronic in 9%; there were femoral shaft fractures in 4.6% and these, with shaft perforation gave universally poor results. Nevertheless, 75% of patients had a satisfactory outcome, with worthwhile relief of pain. It would seem sensible to warn elderly patients and their relatives of the increased risks in this age group


The Journal of Bone & Joint Surgery British Volume
Vol. 46-B, Issue 1 | Pages 32 - 39
1 Feb 1964
Seimon LP

1. A series of twenty-one cases of re-fracture of the femoral shaft has been examined and analysed. 2. Liability to re-fracture may be increased if the original injury is caused by great violence, but it does not seem to be affected by the method of primary treatment. 3. Over 60 per cent of the re-fractures were avoidable. In some, re-fracture was caused by premature institution of vigorous mobilisation; in others, warning cracks were visible on radiographs before re-fracture. 4. In the remaining patients re-fracture appears to be unpredictable and unavoidable. 5. Re-fracture is best treated by the simplest methods


The Journal of Bone & Joint Surgery British Volume
Vol. 61-B, Issue 1 | Pages 101 - 106
1 Feb 1979
Alexander J Barron D

A prospective study on 227 patients undergoing arthroplasty of the hip was carried out with reference to the effects on the cardiovascular and respiratory systems. Investigations revealed that the placing of acrylic bone cement and the prosthesis in the femoral shaft produced clinical and biochemical disturbances which were consistent with pulmonary microembolism. A fall in arterial oxygen tension during the procedure and hypoxaemia extending into the postoperative period with elevation of serum lipase and a fall in triglycerides supported the idea that embolisation with marrow fat occurred. The method of venting (by catheter or proximal hole) did not influence the biochemical disturbances. The implications of these findings are discussed


The Journal of Bone & Joint Surgery British Volume
Vol. 46-B, Issue 1 | Pages 28 - 31
1 Feb 1964
Smith JEM

1. The results in 211 fractures of the shaft of the femur in adults treated by internal fixation have been reviewed. 2. A comparison has been made between the effects of early internal fixation within the first six days of injury and delayed fixation. 3. Eighty-five fractures treated by early fixation gave a rate of non-union of 23 per cent; in 126 fractures treated by delayed fixation the rate was 0·8 per cent. 4. Delayed operation is therefore advocated for the majority of femoral shaft fractures for which internal fixation is indicated


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 3 | Pages 400 - 403
1 May 1996
Voggenreiter G Assenmacher S Klaes W Schmit-Neuerburg K

We have used total hip replacement combined with cemented intramedullary nailing to treat a selected group of nine patients with pathological fractures of the proximal femur and impending fractures of the shaft due to metastases. One patient died from cardiopulmonary failure on the third postoperative day, but the others were able to walk within the first week after operation. Complications included one recurrent dislocation of the THR and one fracture of an osteolytic lesion of the femoral shaft during nail insertion. Both were managed successfully. The hybrid osteosynthesis which we describe is an alternative to the use of tumour or long-stem prostheses; it has the advantage of preserving bone stock and muscle attachments


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 4 | Pages 619 - 621
1 Aug 1988
Hooper G Lyon D

Fifty consecutive comminuted fractures of the femoral shaft were treated by closed unlocked intramedullary nailing. Twelve unstable fractures also had cast-bracing. There were no cases of infection or non-union, and satisfactory results were achieved in 38 fractures (76%). More severe comminution led to a higher incidence of unsatisfactory results, but malrotation deformity was seen more often in less comminuted fractures and appeared to be due to poor operative reduction. Shortening in severe comminution was the main complication and was not controlled by supplementary cast-bracing. Closed unlocked intramedullary nailing is effective for lesser grades of comminution, but fractures with no cortical continuity at reduction should be treated with a locking nail


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 4 | Pages 596 - 599
1 Aug 1988
Pacheco V Shelley P Wroblewski B

A retrospective review of 72 cases of Charnley low friction arthroplasty revised for stem loosening, has identified a number of "at risk" factors. These were: previous hip surgery and, in radiographs taken at one year, demarcation of the distal cement and fracture of the cement near the tip of the stem. Separation of the back of the stem from the cement, as an isolated feature, was not considered significant. Endosteal cavitation of the femoral shaft, rare in the first year, indicated loosening of some duration. Patients whose radiographs show the "at risk" changes, should be followed-up indefinitely in order to plan timely revision and avoid gross loss of the femoral bone stock


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 5 | Pages 652 - 654
1 Jul 2000
Tornetta P Tiburzi D

Retrograde femoral nailing is gaining in popularity. We report a prospective, randomised comparison of antegrade and retrograde procedures in 68 patients with 69 fractures of the femoral shaft. All nails were inserted after appropriate reaming. There was no difference in operating time, blood loss, technical complications, size of nail or reamer, or transfusion requirements. There were more problems of length and rotation using a retrograde technique on a radiolucent table than with an antegrade approach on a fracture table. All fractures in both groups healed and there was no difference in the time taken to achieve union. Although retrograde nailing is a promising technique the skills required need practice. A longer period of follow-up is necessary to determine whether there are long-term problems in the knee after such surgery


Bone & Joint Research
Vol. 10, Issue 11 | Pages 714 - 722
1 Nov 2021
Qi W Feng X Zhang T Wu H Fang C Leung F

Aims

To fully verify the reliability and reproducibility of an experimental method in generating standardized micromotion for the rat femur fracture model.

Methods

A modularized experimental device has been developed that allows rat models to be used instead of large animal models, with the aim of reducing systematic errors and time and money constraints on grouping. The bench test was used to determine the difference between the measured and set values of the micromotion produced by this device under different simulated loading weights. The displacement of the fixator under different loading conditions was measured by compression tests, which was used to simulate the unexpected micromotion caused by the rat’s ambulation. In vivo preliminary experiments with a small sample size were used to test the feasibility and effectiveness of the whole experimental scheme and surgical scheme.


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 5 | Pages 815 - 819
1 Sep 1995
Cohen B Rushton N

We measured bone mineral density (BMD) in the proximal femur by dual-energy X-ray absorptiometry (DEXA) in 20 patients after cemented total hip arthroplasty over a period of one year. We found a statistically significant reduction in periprosthetic BMD after six months on the medial side and on the lateral side adjacent to the mid and distal thirds of the prosthesis. At one year after operation there was a mean 6.7% reduction in BMD in the region of the calcar and a mean 5.3% increase in BMD in the femoral shaft distal to the tip of the implant. These changes reflect a pattern of reduced stress in the proximal femur and increased stress around the tip of the prosthesis. They support current concepts of bone remodelling in the proximal femur in response to prosthetic implantation


Bone & Joint Research
Vol. 11, Issue 3 | Pages 180 - 188
1 Mar 2022
Rajpura A Asle SG Ait Si Selmi T Board T

Aims

Hip arthroplasty aims to accurately recreate joint biomechanics. Considerable attention has been paid to vertical and horizontal offset, but femoral head centre in the anteroposterior (AP) plane has received little attention. This study investigates the accuracy of restoration of joint centre of rotation in the AP plane.

Methods

Postoperative CT scans of 40 patients who underwent unilateral uncemented total hip arthroplasty were analyzed. Anteroposterior offset (APO) and femoral anteversion were measured on both the operated and non-operated sides. Sagittal tilt of the femoral stem was also measured. APO measured on axial slices was defined as the perpendicular distance between a line drawn from the anterior most point of the proximal femur (anterior reference line) to the centre of the femoral head. The anterior reference line was made parallel to the posterior condylar axis of the knee to correct for rotation.


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 5 | Pages 736 - 738
1 Sep 1995
Loder R Farley F Hensinger R

In 40 children with unilateral Perthes' disease, we measured the physeal slope, the angle between the physeal plane and the axis of the femoral shaft, from radiographs taken early in the disease. Thirty-seven of the 40 hips were classified as Catterall grades III and IV. Heat-at-risk signs were present in 23. We found no statistically significant difference in the physeal slope between the involved and normal hips (p = 0.20), those with or without head-at-risk signs (p = 0.96), those with or without lateral epiphyseal subluxation (p = 0.82), and different Catterall (p = 0.56) or lateral pillar (p = 0.67) gradings


Bone & Joint 360
Vol. 10, Issue 4 | Pages 37 - 40
1 Aug 2021


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 6 | Pages 918 - 921
1 Nov 1994
Warwick D Martin A Glew D Bannister G

We examined ten femoral veins with duplex ultrasound during total hip replacement to demonstrate the operative manoeuvres which cause venous obstruction and to assess prophylactic measures which may overcome it. Exposure of the acetabulum by distraction of the femur with a hook was less likely to occlude flow than retraction with bone levers. Adequate exposure of the femoral shaft by adduction, flexion and either internal or external rotation caused cessation of flow in all cases. In four cases an A-V Impulse System foot pump was activated during periods of stasis. In each case it overcame the obstruction and produced peak velocities which were twice that of the resting state. In five cases, towards the end of the procedure, debris was seen travelling proximally through the femoral vein


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 4 | Pages 673 - 678
1 Jul 1998
Yang KH Han DY Park HW Kang HJ Park JH

We report retrospective and prospective studies to identify the causes of fracture of the femoral neck associated with femoral shaft nailing on the same side. Of a total of 14 neck fractures in a series of 152 shaft nailings, eight were not visible on the initial pelvic radiographs. We used CT scans before and after operation, and fluoroscopy during the procedure in our prospective series, and reviewed abdominal CT scans retrospectively with the window set to bone level. Six of the eight undisplaced fractures were shown to have been present before operation, but two were iatrogenic. We recommend the preoperative use of CT scans of the femoral neck in high-risk patients such as those with associated fractures of the acetabulum, the distal femur or the patella. Early diagnosis will allow better general management and early fixation of the neck fracture


The Journal of Bone & Joint Surgery British Volume
Vol. 58-B, Issue 3 | Pages 339 - 342
1 Aug 1976
Edvardsen P Syversen S

Twenty-six children conservatively treated for fracture of the femoral shaft have been reviewed with regard to differences in limb length seven to ten years after the injury. In nine patients the clinical measurements were checked against radiographic measurements of both femora and tibiae. The following conclusions were reached. Nearly two-thirds of the patients had overgrowth of the femur of 10 millimetres or more. Shortening of 15 to 20 millimetres at the fracture site was well compensated for by accelerated growth. Growth acceleration seemed to take place during the healing period and the difference at the end of healing was permanent. Overgrowth was promoted by comminuted and long oblique fractures and by overriding of the fracture ends, but was not influenced by the age at fracture, the duration of treatment or the level of fracture of the shaft. Growth of the tibia was not affected by the femoral fracture


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 4 | Pages 580 - 581
1 Jul 1991
Ritter M Eizember L Keating E Faris P

We used the stainless steel cable grip system described by Dall and Miles in 1983 to fix trochanters in 40 hips after total arthroplasty with trochanteric osteotomy. The cable broke in 32.5% of the hips; the trochanter failed to unite in 37.5%. Significantly more cables broke when placed inside the femoral canal than when the cable was placed round the femoral shaft (58% as against 9.5%, difference p less than 0.01). The high incidence of breakage may have resulted from contact between the stainless steel cable and the titanium prosthesis, from the acute angulation, or because of the lower fatigue strength of stainless steel. Better results have been obtained using cables with a higher fatigue strength, passed outside the proximal femur