The aim of this study was to determine the influence of developmental spinal stenosis (DSS) on the risk of re-operation at an adjacent level. This was a retrospective study of 235 consecutive patients who had undergone decompression-only surgery for lumbar spinal stenosis and had a minimum five-year follow-up. There were 106 female patients (45.1%) and 129 male patients (54.9%), with a mean age at surgery of 66.8 years (Aims
Patients and Methods
Despite declining frequency of blood transfusion and electrolyte supplementation following total joint arthroplasty, postoperative blood analyses are still routinely ordered for these patients. This study aimed to determine the rate of blood transfusion and electrolyte restoration in arthroplasty patients treated with a perioperative blood conservation protocol and to identify risk factors that would predict the need for transfusion and electrolyte supplementation. Patients undergoing primary total joint arthroplasty of the hip or knee between July 2016 and February 2017 at a single institution were included in the study. Standard preoperative and postoperative laboratory data were collected and reviewed retrospectively. A uniform blood conservation programme was implemented for all patients. Need for blood transfusion or potassium supplementation was determined through a coordinated decision by the care team. Rates of transfusion and supplementation were observed, and patient risk factors were noted.Aims
Patients and Methods
This study describes and compares the operative management and outcomes in a consecutive case series of patients with dislocated hemiarthroplasties of the hip, and compares outcomes with those of patients not sustaining a dislocation. Of 3326 consecutive patients treated with hemiarthroplasty for fractured neck of femur, 46 (1.4%) sustained dislocations. Of the 46 dislocations, there were 37 female patients (80.4%) and nine male patients (19.6%) with a mean age of 83.8 years (66 to 100). Operative intervention for each, and subsequent dislocations, were recorded. The following outcome measures were recorded: dislocation; mortality up to one-year post-injury; additional surgery; residential status; mobility; and pain score at one year.Aims
Patients and Methods
The aim of this study was to evaluate the outcomes of a salvage procedure using a 95° angled blade plate for failed osteosynthesis of atypical subtrochanteric femoral fractures associated with the long-term use of bisphosphonates. These were compared with those for failed osteosynthesis of subtrochanteric fractures not associated with bisphosphonate treatment. Between October 2008 and July 2016, 14 patients with failed osteosynthesis of an atypical subtrochanteric femoral fracture were treated with a blade plate (atypical group). Their mean age was 67.8 years (60 to 74); all were female. During the same period, 21 patients with failed osteosynthesis of a typical subtrochanteric fracture underwent restabilization using a blade plate (typical group). Outcome variables included the time of union, postoperative complications, Harris Hip Score, and Sanders functional rating scale.Aims
Patients and Methods
Deep infection was identified as a serious complication in the earliest days of total hip arthroplasty. It was identified that airborne contamination in conventional operating theatres was the major contributing factor. As progress was made in improving the engineering of operating theatres, airborne contamination was reduced. Detailed studies were carried out relating airborne contamination to deep infection rates. In a trial conducted by the United Kingdom Medical Research Council (MRC), it was found that the use of ultra-clean air (UCA) operating theatres was associated with a significant reduction in deep infection rates. Deep infection rates were further reduced by the use of a body exhaust system. The MRC trial also included a detailed microbiology study, which confirmed the relationship between airborne contamination and deep infection rates. Recent observational evidence from joint registries has shown that in contemporary practice, infection rates remain a problem, and may be getting worse. Registry observations have also called into question the value of “laminar flow” operating theatres. Observational evidence from joint registries provides very limited evidence on the efficacy of UCA operating theatres. Although there have been some changes in surgical practice in recent years, the conclusions of the MRC trial remain valid, and the use of UCA is essential in preventing deep infection. There is evidence that if UCA operating theatres are not used correctly, they may have poor microbiological performance. Current UCA operating theatres have limitations, and further research is required to update them and improve their microbiological performance in contemporary practice. Cite this article:
The aims of this study were to quantify health state utility
values (HSUVs) after a tibial fracture, investigate the effect of
complications, to determine the trajectory in HSUVs that result
in these differences and to quantify the quality-adjusted life years
(QALYs) experienced by patients. This is an analysis of 2138 tibial fractures enrolled in the
Fluid Lavage of Open Wounds (FLOW) and Study to Prospectively Evaluate
Reamed Intramedullary Nails in Patients with Tibial Fractures (SPRINT)
trials. Patients returned for follow-up at two and six weeks and
three, six, nine and 12 months. Short-Form Six-Dimension (SF-6D) values
were calculated and used to calculate QALYs.Aims
Patients and Methods
Medial unicompartmental knee arthroplasty (UKA) is associated
with successful outcomes in carefully selected patient cohorts.
We hypothesised that severity and location of patellofemoral cartilage
lesions significantly influences functional outcome after Oxford
medial compartmental knee arthroplasty. We reviewed 100 consecutive UKAs at minimum eight-year follow-up
(96 to 132). A single surgeon performed all procedures. Patients
were selected based on clinical and plain radiographic assessment.
All patients had end-stage medial compartment osteoarthritis (OA)
with sparing of the lateral compartment and intact anterior cruciate ligaments.
None of the patients had end-stage patellofemoral OA, but patients
with anterior knee pain or partial thickness chondral loss were
not excluded. There were 57 male and 43 female patients. The mean
age at surgery was 69 years (41 to 82). At surgery the joint was
carefully inspected for patellofemoral chondral loss and this was documented
based on severity of cartilage loss (0 to 4 Outerbridge grading)
and topographic location (medial, lateral, central, and superior
or inferior). Functional scores collected included Oxford Knee Score
(OKS), patient satisfaction scale and University College Hospital
(UCH) knee score. Intraclass correlation was used to compare chondral
damage to outcomes.Aims
Patients and Methods
‘Big data’ is a term for data sets that are so
large or complex that traditional data processing applications are
inadequate. Billions of dollars have been spent on attempts to build predictive
tools from large sets of poorly controlled healthcare metadata.
Companies often sell reports at a physician or facility level based
on various flawed data sources, and comparative websites of ‘publicly
reported data’ purport to educate the public. Physicians should
be aware of concerns and pitfalls seen in such data definitions,
data clarity, data relevance, data sources and data cleaning when
evaluating analytic reports from metadata in health care. Cite this article:
This 501-patient, multi-centre, randomised controlled trial sought
to establish the effect of low-intensity, pulsed, ultrasound (LIPUS)
on tibial shaft fractures managed with intramedullary nailing. We
conducted an economic evaluation as part of this trial. Data for patients’ use of post-operative healthcare resources
and time taken to return to work were collected and costed using
publicly available sources. Health-related quality of life, assessed
using the Health Utilities Index Mark-3 (HUI-3), was used to derive
quality-adjusted life years (QALYs). Costs and QALYs were compared
between LIPUS and control (a placebo device) from a payer and societal
perspective using non-parametric bootstrapping. All costs are reported
in 2015 Canadian dollars unless otherwise stated.Aims
Patients and Methods