The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 2 | Pages 255 - 260
1 Feb 2006
Shin EK Jones NF Lawrence JF

We have evaluated the clinical outcomes of simple excision, ulnar lengthening and the Sauvé-Kapandji procedure in the treatment of deformities of the forearm in patients with multiple hereditary osteochondromas. The medical records of 29 patients (33 forearms) were reviewed; 22 patients (22 forearms) underwent simple excision (four with ulnar lengthening) and seven the Sauvé-Kapandji procedure.

Simple excision increased the mean supination of the forearm from 63.2° to 75.0° (p = 0.049). Ulnar lengthening did not significantly affect the clinical outcome. The Sauvé-Kapandji technique improved the mean pronation from 33.6° to 55.0° (p = 0.047) and supination from 70.0° to 81.4° (p = 0.045). Simple excision may improve the range of movement of the forearm but will not halt the progression of disease, particularly in younger patients. No discernable clinical or radiological improvement was noted with ulnar lengthening. The Sauvé-Kapandji procedure combined with simple excision of osteochondromas can improve stability of the wrist, movement of the forearm and the radiological appearance.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 4 | Pages 425 - 433
1 Apr 2007
Little DG Ramachandran M Schindeler A

The literature on fracture repair has been reviewed. The traditional concepts of delayed and nonunion have been examined in terms of the phased and balanced anabolic and catabolic responses in bone repair. The role of medical manipulation of these inter-related responses in the fracture healing have been considered.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 1 | Pages 61 - 64
1 Jan 2006
Krishnan SP Skinner JA Bartlett W Carrington RWJ Flanagan AM Briggs TWR Bentley G

We investigated the prognostic indicators for collagen-covered autologous chondrocyte implantation (ACI-C) performed for symptomatic osteochondral defects of the knee.

We analysed prospectively 199 patients for up to four years after surgery using the modified Cincinnati score. Arthroscopic assessment and biopsy of the neocartilage was also performed whenever possible. The favourable factors for ACI-C include younger patients with higher pre-operative modified Cincinnati scores, a less than two-year history of symptoms, a single defect, a defect on the trochlea or lateral femoral condyle and patients with fewer than two previous procedures on the index knee. Revision ACI-C in patients with previous ACI and mosaicplasties which had failed produced significantly inferior clinical results. Gender (p = 0.20) and the size of the defect (p = 0.97) did not significantly influence the outcome.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 3 | Pages 354 - 360
1 Mar 2007
Konrad GG Kundel K Kreuz PC Oberst M Sudkamp NP

The objective of this retrospective study was to correlate the Bado and Jupiter classifications with long-term results after operative treatment of Monteggia fractures in adults and to determine prognostic factors for functional outcome. Of 63 adult patients who sustained a Monteggia fracture in a ten-year period, 47 were available for follow-up after a mean time of 8.4 years (5 to 14). According to the Broberg and Morrey elbow scale, 22 patients (47%) had excellent, 12 (26%) good, nine (19%) fair and four (8%) poor results at the last follow-up. A total of 12 patients (26%) needed a second operation within 12 months of the initial operation. The mean Broberg and Morrey score was 87.2 (45 to 100) and the mean DASH score was 17.4 (0 to 70). There was a significant correlation between the two scores (p = 0.01). The following factors were found to be correlated with a poor clinical outcome: Bado type II fracture, Jupiter type IIa fracture, fracture of the radial head, coronoid fracture, and complications requiring further surgery.

Bado type II Monteggia fractures, and within this group, Jupiter type IIa fractures, are frequently associated with fractures of the radial head and the coronoid process, and should be considered as negative prognostic factors for functional long-term outcome. Patients with these types of fracture should be informed about the potential risk of functional deficits and the possible need for further surgery.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 8 | Pages 1077 - 1080
1 Aug 2005
Sharma S Nicol F Hullin MG McCreath SW

We analysed the long-term clinical and radiological results of 63 uncemented Low Contact Stress total knee replacements in 47 patients with rheumatoid arthritis. At a mean follow-up of 12.9 years (10 to 16), 36 patients (49 knees) were still alive; three patients (five knees) were lost to follow-up. Revision was necessary in three knees (4.8%) and the rate of infection was 3.2%. The mean clinical and functional Knee Society scores were 90 (30 to 98) and 59 (25 to 90), respectively, at final follow-up and the mean active range of movement was 104° (55° to 120°). The survival rate was 94% at 16 years but 85.5% of patients lost to follow-up were considered as failures. Radiological evidence of impending failure was noted in one knee.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 12 | Pages 1617 - 1621
1 Dec 2005
O’Shea K Quinlan JF Kutty S Mulcahy D Brady OH

We assessed the outcome of patients with Vancouver type B2 and B3 periprosthetic fractures treated with femoral revision using an uncemented extensively porous-coated implant. A retrospective clinical and radiographic assessment of 22 patients with a mean follow-up of 33.7 months was performed. The mean time from the index procedure to fracture was 10.8 years. There were 17 patients with a satisfactory result. Complications in four patients included subsidence in two, deep sepsis in one, and delayed union in one. Concomitant acetabular revision was required in 19 patients. Uncemented extensively porous-coated femoral stems incorporate distally allowing stable fixation. We found good early survival rates and a low incidence of nonunion using this implant.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 11 | Pages 1454 - 1458
1 Nov 2005
Govender S


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 1 | Pages 26 - 30
1 Jan 2006
Lindahl H Malchau H Odén A Garellick G

Periprosthetic fracture of the femur is an uncommon complication after total hip replacement, but appears to be increasing. We undertook a nationwide observational study to determine the risk factors for failure after treatment of these fractures, examining patient- and implant-related factors, the classification of the fractures and the outcome.

Between 1979 and 2000, 1049 periprosthetic fractures of the femur were reported to the Swedish National Hip Arthroplasty Register. Of these, 245 had a further operation after failure of their initial management. Data were collected from the Register and hospital records. The material was analysed by the use of Poisson regression models.

It was found that the risk of failure of treatment was reduced for Vancouver type B2 injuries (p = 0.0053) if revision of the implant was undertaken (p = 0.0033) or revision and open reduction and internal fixation (p = 0.0039) were performed. Fractures classified as Vancouver type B1 had a significantly higher risk of failure (p = 0.0001). The strongest negative factor was the use of a single plate for fixation (p = 0.001). The most common reasons for failure in this group were loosening of the femoral prosthesis, nonunion and re-fracture.

It is probable that many fractures classified as Vancouver type B1 (n = 304), were in reality type B2 fractures with a loose stem which were not recognised. Plate fixation was inadequate in these cases. The difficulty in separating type B1 from type B2 fractures suggests that the prosthesis should be considered as loose until proven otherwise.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 6 | Pages 837 - 840
1 Jun 2005
Azzopardi T Ehrendorfer S Coulton T Abela M

We performed a prospective, randomised study on 57 patients older than 60 years of age with unstable, extra-articular fractures of the distal radius to compare the outcome of immobilisation in a cast alone with that using supplementary, percutaneous pinning.

Patients treated by percutaneous wires had a statistically significant improvement in dorsal angulation (mean 7°), radial length (mean 3 mm) and radial inclination (mean 3 mm) at one year. However, there was no significant difference in functional outcome in terms of pain, range of movement, grip strength, activities of daily living and the SF-36 score except for an improved range of movement in ulnar deviation in the percutaneous wire group. One patient developed a pin-track infection which required removal of the wires at two weeks.

We conclude that percutaneous pinning of unstable, extra-articular fractures of the distal radius provides only a marginal improvement in the radiological parameters compared with immobilisation in a cast alone. This does not correlate with an improved functional outcome in a low-demand, elderly population.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 7 | Pages 960 - 966
1 Jul 2006
Pluhar GE Turner AS Pierce AR Toth CA Wheeler DL

Critical size defects in ovine tibiae, stabilised with intramedullary interlocking nails, were used to assess whether the addition of carboxymethylcellulose to the standard osteogenic protein-1 (OP-1/BMP-7) implant would affect the implant’s efficacy for bone regeneration. The biomaterial carriers were a ‘putty’ carrier of carboxymethylcellulose and bovine-derived type-I collagen (OPP) or the standard with collagen alone (OPC). These two treatments were also compared to “ungrafted” negative controls. Efficacy of regeneration was determined using radiological, biomechanical and histological evaluations after four months of healing. The defects, filled with OPP and OPC, demonstrated radiodense material spanning the defect after one month of healing, with radiographic evidence of recorticalisation and remodelling by two months. The OPP and OPC treatment groups had equivalent structural and material properties that were significantly greater than those in the ungrafted controls. The structural properties of the OPP- and OPC-treated limbs were equivalent to those of the contralateral untreated limb (p > 0.05), yet material properties were inferior (p < 0.05). Histopathology revealed no residual inflammatory response to the biomaterial carriers or OP-1. The OPP- and OPC-treated animals had 60% to 85% lamellar bone within the defect, and less than 25% of the regenerate was composed of fibrous tissue. The defects in the untreated control animals contained less than 40% lamellar bone and more than 60% was fibrous tissue, creating full cortical thickness defects. In our studies carboxymethylcellulose did not adversely affect the capacity of the standard OP-1 implant for regenerating bone.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 3 | Pages 290 - 294
1 Mar 2006
Anderson GA


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 3 | Pages 306 - 309
1 Mar 2005
Ito H Matsuno T Minami A

We present the medium-term results of hybrid total hip arthroplasties using pre-coated stems with a second-generation cementing technique. The 128 hips in 111 patients (18 men and 93 women) were followed up at a mean of 11 years after surgery. The mean age at the time of surgery was 61 years. Both components of one hip were removed at ten months after surgery for infection. None of the other 127 femoral components showed possible, probable, or definite loosening at the most recent follow-up. Five acetabular components were revised for aseptic loosening, recurrent dislocation, or displacement of the polyethylene liner from the metal shell. The mean Harris hip score at follow-up was 84 points. A pre-coated femoral component with a second-generation cementing technique provides good clinical function and survival in the medium term.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 10 | Pages 1394 - 1400
1 Oct 2006
Eid K Labler L Ertel W Trentz O Keel M

Systemic factors are believed to be pivotal for the development of heterotopic ossification in severely-injured patients. In this study, cell cultures of putative target cells (human fibroblastic cells, osteoblastic cells (MG-63), and bone-marrow stromal cells (hBM)) were incubated with serum from ten consecutive polytraumatised patients taken from post-traumatic day 1 to day 21 and with serum from 12 healthy control subjects.

The serum from the polytraumatised patients significantly stimulated the proliferation of fibroblasts, MG-63 and of hBM cells. The activity of alkaline phosphatase in MG-63 and hBM cells was significantly decreased when exposed to the serum of the severely-injured patient. After three weeks in 3D cell cultures, matrix production and osteogenic gene expression of hBM cells were equal in the patient and control groups. However, the serum from the polytraumatised patients significantly decreased apoptosis of hBM cells compared with the control serum (4.3% vs 19.1%, p = 0.031).

Increased proliferation of osteoblastic cells and reduced apoptosis of osteoprogenitors may be responsible for increased osteogenesis in severely-injured patients.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 7 | Pages 955 - 958
1 Jul 2005
Tanaka N Sakahashi H Hirose K Ishima T Takahashi H Ishii S

We evaluated the use of surgical stabilisation for atlantoaxial subluxation after a follow-up of 24 years in 50 rheumatoid patients who had some degree of pain but no major neurological deficit.

The mortality of patients treated by atlantoaxial fusion was significantly lower than for those who received conservative treatment. The deaths resulted from infection or comorbid conditions. The significantly high relative risks of mortality from conservative treatment compared with surgical treatment were mutilating disease and susceptible factors on both of the HLA-DRB1 alleles. Relief from pain and neurological and functional recovery were better, and the radiological degree of atlantoaxial translocation was less in those who were surgically treated compared with those who were not. Two patients had superficial local infections after surgery. We conclude that prophylactic atlantoaxial fusion is better than conservative treatment in these patients.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 3 | Pages 416 - 420
1 Mar 2005
Bobyn JD Hacking SA Krygier JJ Harvey EJ Little DG Tanzer M

The effect of zoledronic acid on bone ingrowth was examined in an animal model in which porous tantalum implants were placed bilaterally within the ulnae of seven dogs. Zoledronic acid in saline was administered via a single post-operative intravenous injection at a dose of 0.1 mg/kg. The ulnae were harvested six weeks after surgery. Undecalcified transverse histological sections of the implant-bone interfaces were imaged with backscattered scanning electron microscopy and the percentage of available pore space that was filled with new bone was calculated. The mean extent of bone ingrowth was 6.6% for the control implants and 12.2% for the zoledronic acid-treated implants, an absolute difference of 5.6% (95% confidence interval, 1.2 to 10.1) and a relative difference of 85% which was statistically significant. Individual islands of new bone formation within the implant pores were similar in number in both groups but were 69% larger in the zoledronic acid-treated group. The bisphosphonate zoledronic acid should be further investigated for use in accelerating or enhancing the biological fixation of implants to bone.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 8 | Pages 997 - 1002
1 Aug 2006
Vendittoli P Lavigne M Girard J Roy AG

We have undertaken a prospective, randomised study to compare conservation of acetabular bone after total hip replacement and resurfacing arthroplasty of the hip. We randomly assigned 210 hips to one of the two treatment groups. Uncemented, press-fit acetabular components were used for both.

No significant difference was found in the mean diameter of acetabular implant inserted in the groups (54.74 mm for total hip replacement and 54.90 mm for resurfacing arthroplasty). In seven resurfacing procedures (6.8%), the surgeon used a larger size of component in order to match the corresponding diameter of the femoral component.

With resurfacing arthroplasty, conservation of bone is clearly advantageous on the femoral side. Our study has shown that, with a specific design of acetabular implant and by following a careful surgical technique, removal of bone on the acetabular side is comparable with that of total hip replacement.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 11 | Pages 1430 - 1437
1 Nov 2006
Michalak KA Khoo PPC Yates PJ Day RE Wood DJ

Revision arthroplasty after infection can often be complicated by both extensive bone loss and a relatively high rate of re-infection. Using allograft to address the bone loss in such patients is controversial because of the perceived risk of bacterial infection from the use of avascular graft material. We describe 12 two-stage revisions for infection in which segmental allografts were loaded with antibiotics using iontophoresis, a technique using an electrical potential to drive ionised antibiotics into cortical bone.

Iontophoresis produced high levels of antibiotic in the allograft, which eluted into the surrounding tissues. We postulate that this offers protection from infection in the high-risk peri-operative period. None of the 12 patients who had two-stage revision with iontophoresed allografts had further infection after a mean period of 47 months (14 to 78).


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 7 | Pages 870 - 876
1 Jul 2006
Khan RJK Fick D Alakeson R Haebich S de Cruz M Nivbrant B Wood D

We treated 34 patients with recurrent dislocation of the hip with a constrained acetabular component. Roentgen stereophotogrammetric analysis was performed to assess migration of the prosthesis.

The mean clinical follow-up was 3.0 years (2.2 to 4.8) and the radiological follow-up was 2.7 years (2.0 to 4.8). At the latest review six patients had died and none was lost to follow-up. There were four acetabular revisions, three for aseptic loosening and one for deep infection. Another acetabular component was radiologically loose with progressive radiolucent lines in all Gruen zones and was awaiting revision. The overall rate of aseptic loosening was 11.8% (4 of 34). Roentgen stereophotogrammetric analysis in the non-revised components confirmed migration of up to 1.06 mm of translation and 2.32° of rotation at 24 months. There was one case of dislocation and dissociation of the component in the same patient. Of the 34 patients, 33 (97.1%) had no further episodes of dislocation.

The constrained acetabular component reported in our study was effective in all but one patient with instability of the hip, but the rate of aseptic loosening was higher than has been reported previously and requires further investigation.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 9 | Pages 1248 - 1252
1 Sep 2005
Awad JN Kebaish KM Donigan J Cohen DB Kostuik JP

In order to identify the risk factors and the incidence of post-operative spinal epidural haematoma, we analysed the records of 14 932 patients undergoing spinal surgery between 1984 and 2002. Of these, 32 (0.2%) required re-operation within one week of the initial procedure and had an International Classification of Diseases (ICD)-9 code for haematoma complicating a procedure (998.12). As controls, we selected those who had undergone a procedure of equal complexity by the same surgeon but who had not developed this complication. Risks identified before operation were older than 60 years of age, the use of pre-operative non-steroidal anti-inflammatories and Rh-positive blood type. Those during the procedure were involvement of more than five operative levels, a haemoglobin < 10 g/dL, and blood loss > 1 L, and after operation an international normalised ratio > 2.0 within the first 48 hours. All these were identified as significant (p < 0.03). Well-controlled anticoagulation and the use of drains were not associated with an increased risk of post-operative spinal epidural haematoma.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 11 | Pages 1568 - 1574
1 Nov 2005
Day RE Megson S Wood D

Allograft bone is widely used in orthopaedic surgery, but peri-operative infection of the graft remains a common and disastrous complication. The efficacy of systemic prophylactic antibiotics is unproven, and since the graft is avascular it is likely that levels of antibiotic in the graft are low.

Using an electrical potential to accelerate diffusion of antibiotics into allograft bone, high levels were achieved in specimens of both sheep and human allograft. In human bone these ranged from 187.1 mg/kg in endosteal (sd 15.7) to 124.6 (sd 46.2) in periosteal bone for gentamicin and 31.9 (sd 8.9) in endosteal and 2.9 (sd 1.1) in periosteal bone for flucloxacillin. The antibiotics remained active against bacteria in vitro after iontophoresis and continued to elute from the allograft for up to two weeks.

Structural allograft can be supplemented directly with antibiotics using iontophoresis. The technique is simple and inexpensive and offers a potential means of reducing the rate of peri-operative infection in allograft surgery. Iontophoresis into allograft bone may also be applicable to other therapeutic compounds.