header advert
Results 1161 - 1180 of 1901
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 8 | Pages 1074 - 1077
1 Aug 2009
Singh VK Kalairajah Y

An intra-operative splash is a common occurrence in elective knee and hip replacement surgery and can potentially transmit bloodborne diseases, with devastating consequences. This study aimed to quantify the risk of a splash and to assess its correlation with body mass index, duration of surgery and the volume of lavage fluid used. Between December 2007 and April 2008, 62 consecutive patients (38 women, 24 men) undergoing an elective total knee or total hip replacement (TKR, THR) were recruited into the study (32 TKRs and 30 THRs) after appropriate consent. A splash occurred in all 62 cases. A THR had a slightly higher risk of a splash than a TKR, but this was not statistically significant (p = 0.27). The correlation between body mass index, duration of surgery and the amount of pulse lavage used with a splash was r = 0.013, (non-significant), r = 0.52, (significant) and r = 0.92 (highly significant), respectively. A high number of splashes are generated during a TKR and a THR. The simple visor mask fails to protect the surgeon, the assistant or the patient from the risk of a splash and reverse splash, respectively


The Bone & Joint Journal
Vol. 102-B, Issue 6 Supple A | Pages 158 - 162
1 Jun 2020
Griseti Q Jacquet C Sautet P Abdel MP Parratte S Ollivier M Argenson J

Aims

The aim of this study was to compare the ability of tantalum, 3D porous titanium, antibiotic-loaded bone cement, and smooth titanium alloy to inhibit staphylococci in an in vitro environment, based on the evaluation of the zone of inhibition (ZOI). The hypothesis was that there would be no significant difference in the inhibition of methicillin-sensitive or methicillin-resistant Staphylococcus aureus (MSSA/MRSA) between the two groups.

Methods

A total of 30 beads made of three different materials (tantalum/3D porous titanium and smooth titanium alloy) were bathed for one hour in a solution of 1 g vancomycin in 20 ml of sterile water for injection (bath concentration: 50 mg/mL). Ten 1 cm3 cylinders of antibiotic-loaded cement were also created by mixing standard surgical cement with 1 g of vancomycin in standardized sterile moulds. The cylinders were then placed on agar plates inoculated with MSSA and MRSA. The ZOIs were measured each day and the cylinders were transferred onto a new inoculated plate.


Bone & Joint Research
Vol. 4, Issue 8 | Pages 137 - 144
1 Aug 2015
Hamilton DF Giesinger JM Patton JT MacDonald DJ Simpson AHRW Howie CR Giesinger K

Objectives. The Oxford Hip and Knee Scores (OHS, OKS) have been demonstrated to vary according to age and gender, making it difficult to compare results in cohorts with different demographics. The aim of this paper was to calculate reference values for different patient groups and highlight the concept of normative reference data to contextualise an individual’s outcome. Methods. We accessed prospectively collected OHS and OKS data for patients undergoing lower limb joint arthroplasty at a single orthopaedic teaching hospital during a five-year period. T-scores were calculated based on the OHS and OKS distributions. . Results. Data were obtained from 3203 total hip arthroplasty (THA) patients and 2742 total knee arthroplasty (TKA) patients. The mean age of the patient was 68.0 years (. sd. 11.3, 58.4% women) in the THA group and in 70.2 (. sd. 9.4; 57.5% women) in the TKA group. T-scores were calculated for age and gender subgroups by operation. Different T-score thresholds are seen at different time points pre and post surgery. Values are further stratified by operation (THA/TKA) age and gender. Conclusions. Normative data interpretation requires a fundamental shift in the thinking as to the use of the Oxford Scores. Instead of reporting actual score points, the patient is rated by their relative position within the group of all patients undergoing the same procedure. It is proposed that this form of transformation is beneficial (a) for more appropriately comparing different patient cohorts and (b) informing an individual patient how they are progressing compared with others of their age and gender. Cite this article: Bone Joint Res 2015;4:137–144


The Bone & Joint Journal
Vol. 96-B, Issue 11_Supple_A | Pages 112 - 114
1 Nov 2014
Abdel MP Haas SB

Instability after total knee replacement (TKR) accounts for 10% to 22% of revision procedures. All patients who present for evaluation of instability require a thorough history to be taken and physical examination, as well as appropriate imaging. Deep periprosthetic infection must be ruled out by laboratory testing and an aspiration of the knee must be carried out. The three main categories of instability include flexion instability, extension instability (symmetric and asymmetric), and genu recurvatum. Most recently, the aetiologies contributing to, and surgical manoeuvres required to correct, flexion instability have been elucidated. While implant design and patient-related factors may certainly contribute to the aetiology, surgical technique is also a significant factor in all forms of post-operative instability. Cite this article: Bone Joint J 2014;96-B(11 Suppl A):112–4


Bone & Joint Open
Vol. 1, Issue 6 | Pages 229 - 235
9 Jun 2020
Lazizi M Marusza CJ Sexton SA Middleton RG

Aims

Elective surgery has been severely curtailed as a result of the COVID-19 pandemic. There is little evidence to guide surgeons in assessing what processes should be put in place to restart elective surgery safely in a time of endemic COVID-19 in the community.

Methods

We used data from a stand-alone hospital admitting and operating on 91 trauma patients. All patients were screened on admission and 100% of patients have been followed-up after discharge to assess outcome.


Bone & Joint 360
Vol. 8, Issue 5 | Pages 16 - 19
1 Oct 2019


The Bone & Joint Journal
Vol. 96-B, Issue 11 | Pages 1498 - 1502
1 Nov 2014
Riis A Rathleff MS Jensen MB Simonsen O

The optimal timing of total knee replacement (TKR) in patients with osteoarthritis, in relation to the severity of disease, remains controversial. This prospective study was performed to investigate the effect of the severity of osteoarthritis and other commonly available pre- and post-operative clinical parameters on the clinical outcome in a consecutive series of cemented TKRs. A total of 176 patients who underwent unilateral TKR were included in the study. Their mean age was 68 years (39 to 91), 63 (36%) were male and 131 knees (74%) were classified as grade 4 on the Kellgren–Lawrence osteoarthritis scale. A total of 154 patients (87.5%) returned for clinical review 12 months post-operatively, at which time the outcome was assessed using the Knee Society score. . A low radiological severity of osteoarthritis was not associated with pain 12 months post-operatively. However, it was significantly associated with an inferior level of function (p = 0.007), implying the need for increased focus on all possible reasons for pain in the knee and the forms of conservative treatment which are available for patients with lower radiological severity of osteoarthritis. Cite this article: Bone Joint J 2014; 96-B:1498–1502


The Bone & Joint Journal
Vol. 101-B, Issue 11 | Pages 1447 - 1458
1 Nov 2019
Chatziagorou G Lindahl H Kärrholm J

Aims

We investigated patient characteristics and outcomes of Vancouver type B periprosthetic fractures treated with femoral component revision and/or osteosynthesis.

Patients and Methods

The study utilized data from the Swedish Hip Arthroplasty Register (SHAR) and information from patient records. We included all primary total hip arthroplasties (THAs) performed in Sweden since 1979, and undergoing further surgery due to Vancouver type B periprosthetic femoral fracture between 2001 and 2011. The primary outcome measure was any further reoperation between 2001 and 2013. Cross-referencing with the National Patient Register was performed in two stages, in order to identify all surgical procedures not recorded on the SHAR.


Bone & Joint Open
Vol. 1, Issue 5 | Pages 152 - 159
22 May 2020
Oommen AT Chandy VJ Jeyaraj C Kandagaddala M Hariharan TD Arun Shankar A Poonnoose PM Korula RJ

Aims

Complex total hip arthroplasty (THA) with subtrochanteric shortening osteotomy is necessary in conditions other than developmental dysplasia of the hip (DDH) and septic arthritis sequelae with significant proximal femur migration. Our aim was to evaluate the hip centre restoration with THAs in these hips.

Methods

In all, 27 THAs in 25 patients requiring THA with femoral shortening between 2012 and 2019 were assessed. Bilateral shortening was required in two patients. Subtrochanteric shortening was required in 14 out of 27 hips (51.9%) with aetiology other than DDH or septic arthritis. Vertical centre of rotation (VCOR), horizontal centre of rotation, offset, and functional outcome was calculated. The mean followup was 24.4 months (5 to 92 months).


The Bone & Joint Journal
Vol. 102-B, Issue 1 | Pages 82 - 89
1 Jan 2020
Coenders MJ Mathijssen NMC Vehmeijer SBW

Aims

The aim of this study was to report our experience at 3.5 years with outpatient total hip arthroplasty (THA).

Methods

In this prospective cohort study, we included all patients who were planned to receive primary THA through the anterior approach between 1 April 2014 and 1 October 2017. Patient-related data and surgical information were recorded. Patient reported outcome measures (PROMs) related to the hip and an anchor question were taken preoperatively, at six weeks, three months, and one year after surgery. All complications, readmissions, and reoperations were registered.


The Bone & Joint Journal
Vol. 101-B, Issue 10 | Pages 1177 - 1178
1 Oct 2019
Troelsen A Haddad FS


The Bone & Joint Journal
Vol. 101-B, Issue 10 | Pages 1248 - 1255
1 Oct 2019
Pineda A Pabbruwe MB Kop AM Vlaskovsky P Hurworth M

Aims

The aim of this study was to conduct the largest low contact stress (LCS) retrieval study to elucidate the failure mechanisms of the Porocoat and Duofix femoral component. The latter design was voluntarily recalled by the manufacturer.

Materials and Methods

Uncemented LCS explants were divided into three groups: Duofix, Porocoat, and mixed. Demographics, polyethylene wear, tissue ingrowth, and metallurgical analyses were performed.


The Bone & Joint Journal
Vol. 96-B, Issue 11_Supple_A | Pages 78 - 83
1 Nov 2014
Gustke KA

Total knee replacement (TKR) smart tibial trials have load-bearing sensors which will show quantitative compartment pressure values and femoral-tibial tracking patterns. Without smart trials, surgeons rely on feel and visual estimation of imbalance to determine if the knee is optimally balanced. Corrective soft-tissue releases are performed with minimal feedback as to what and how much should be released. The smart tibial trials demonstrate graphically where and how much imbalance is present, so that incremental releases can be performed. The smart tibial trials now also incorporate accelerometers which demonstrate the axial alignment. This now allows the surgeon the option to perform a slight recut of the tibia or femur to provide soft-tissue balance without performing soft-tissue releases. Using a smart tibial trial to assist with soft-tissue releases or bone re-cuts, improved patient outcomes have been demonstrated at one year in a multicentre study of 135 patients (135 knees). Cite this article: Bone Joint J 2014;96-B(11 Suppl A):78–83


The Bone & Joint Journal
Vol. 102-B, Issue 6 | Pages 683 - 692
1 Jun 2020
Arnold N Anis H Barsoum WK Bloomfield MR Brooks PJ Higuera CA Kamath AF Klika A Krebs VE Mesko NW Molloy RM Mont MA Murray TG Patel PD Strnad G Stearns KL Warren J Zajichek A Piuzzi NS

Aims

Thresholds for operative eligibility based on body mass index (BMI) alone may restrict patient access to the benefits of arthroplasty. The purpose of this study was to evaluate the relationship between BMI and improvements in patient-reported outcome measures (PROMs), and to determine how many patients would have been denied improvements in PROMs if BMI cut-offs were to be implemented.

Methods

A prospective cohort of 3,449 primary total hip arthroplasties (THAs) performed between 2015 and 2018 were analyzed. The following one-year PROMs were evaluated: hip injury and osteoarthritis outcome score (HOOS) pain, HOOS Physical Function Shortform (PS), University of California, Los Angeles (UCLA) activity, Veterans Rand-12 Physical Component Score (VR-12 PCS), and VR-12 Mental Component Score (VR-12 MCS). Positive predictive values for failure to improve and the number of patients denied surgery in order to avoid a failed improvement were calculated for each PROM at different BMI cut-offs.


The Bone & Joint Journal
Vol. 96-B, Issue 11 | Pages 1515 - 1519
1 Nov 2014
Allen D Sale G

Although patients with a history of venous thromboembolism (VTE) who undergo lower limb joint replacement are thought to be at high risk of further VTE, the actual rate of recurrence has not been reported. The purpose of this study was to identify the recurrence rate of VTE in patients who had undergone lower limb joint replacement, and to compare it with that of patients who had undergone a joint replacement without a history of VTE. . From a pool of 6646 arthroplasty procedures (3344 TKR, 2907 THR, 243 revision THR, 152 revision TKR) in 5967 patients (68% female, mean age 67.7; 21 to 96) carried out between 2009 and 2011, we retrospectively identified 118 consecutive treatment episodes in 106 patients (65% female, mean age 70; 51 to 88,) who had suffered a previous VTE. Despite mechanical prophylaxis and anticoagulation with warfarin, we had four recurrences by three months (3.4% of 118) and six by one year (5.1% of 118). In comparison, in all our other joint replacements the rate of VTE was 0.54% (35/6528). The relative risk of a VTE by 90 days in patients who had undergone a joint replacement with a history of VTE compared with those with a joint replacement and no history of VTE was 6.3 (95% confidence interval, 2.3 to 17.5). There were five complications in the previous VTE group related to bleeding or over-anticoagulation. Cite this article: Bone Joint J 2014;96-B:1515–19


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 2 | Pages 238 - 242
1 Feb 2006
Khan RJK Fick D Yao F Tang K Hurworth M Nivbrant B Wood D

We carried out a blinded prospective randomised controlled trial comparing 2-octylcyanoacrylate (OCA), subcuticular suture (monocryl) and skin staples for skin closure following total hip and total knee arthroplasty. We included 102 hip replacements and 85 of the knee. OCA was associated with less wound discharge in the first 24 hours for both the hip and the knee. However, with total knee replacement there was a trend for a more prolonged wound discharge with OCA. With total hip replacement there was no significant difference between the groups for either early or late complications. Closure of the wound with skin staples was significantly faster than with OCA or suture. There was no significant difference in the length of stay in hospital, Hollander wound evaluation score (cosmesis) or patient satisfaction between the groups at six weeks for either hips or knees. We consider that skin staples are the skin closure of choice for both hip and knee replacements


Bone & Joint 360
Vol. 3, Issue 1 | Pages 17 - 20
1 Feb 2014

The February 2014 Knee Roundup. 360 . looks at: whether sham surgery is as good as arthroscopic meniscectomy; distraction in knee osteoarthritis; whether trans-tibial tunnel placement increases the risk of graft failure in ACL surgery; whether joint replacements prevent cardiac events; the size of the pulmonary embolism problem; tranexamic acid and knee replacement haemostasis; matching the demand for knee replacement and follow-up; predicting the length of stay after knee replacement; and popliteal artery injury in TKR


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 12 | Pages 1591 - 1595
1 Dec 2006
Price AJ Oppold PT Murray DW Zavatsky AB

The Oxford medial unicompartmental knee replacement was designed to reproduce normal mobility and forces in the knee, but its detailed effect on the patellofemoral joint has not been studied previously. We have examined the effect on patellofemoral mechanics of the knee by simultaneously measuring patellofemoral kinematics and forces in 11 cadaver knee specimens in a supine leg-extension rig. Comparison was made between the intact normal knee and sequential unicompartmental and total knee replacement. Following medial mobile-bearing unicompartmental replacement in 11 knees, patellofemoral kinematics and forces did not change significantly from those in the intact knee across any measured parameter. In contrast, following posterior cruciate ligament retaining total knee replacement in eight knees, there were significant changes in patellofemoral movement and forces. The Oxford device appears to produce near-normal patellofemoral mechanics, which may partly explain the low incidence of complications with the extensor mechanism associated with clinical use


The Bone & Joint Journal
Vol. 97-B, Issue 7 | Pages 905 - 910
1 Jul 2015
Hsu C Lin P Kuo F Wang J

Tranexamic acid (TXA), an inhibitor of fibrinolysis, reduces blood loss after total knee arthroplasty. However, its effect on minimally invasive total hip arthroplasty (THA) is not clear. We performed a prospective, randomised double-blind study to evaluate the effect of two intravenous injections of TXA on blood loss in patients undergoing minimally invasive THA. In total, 60 patients (35 women and 25 men with a mean age of 58.1 years; 17 to 84) who underwent unilateral minimally invasive uncemented THA were randomly divided into the study group (30 patients, 20 women and ten men with a mean age of 56.5 years; 17 to 79) that received two intravenous injections 1 g of TXA pre- and post-operatively (TXA group), and a placebo group (30 patients, 15 women and 15 men with a mean age of 59.5 years; 23 to 84). We compared the peri-operative blood loss of the two groups. Actual blood loss was calculated from the maximum reduction in the level of haemoglobin. All patients were followed clinically for the presence of venous thromboembolism. The TXA group had a lower mean intra-operative blood loss of 441 ml (150 to 800) versus 615 ml (50 to 1580) in the placebo (p = 0.044), lower mean post-operative blood loss (285 ml (120 to 570) versus 392 ml (126 to 660) (p = 0.002), lower mean total blood loss (1070 ml (688 to 1478) versus 1337 ml (495 to 2238) (p = 0.004) and lower requirement for transfusion (p = 0.021). No patients in either group had symptoms of venous thromboembolism or wound complications. . This prospective, randomised controlled study showed that a regimen of two intravenous injections of 1 g TXA is effective for blood conservation after minimally invasive THA. Cite this article: Bone Joint J 2015;97-B:905–10


Bone & Joint Research
Vol. 3, Issue 10 | Pages 289 - 296
1 Oct 2014
van IJsseldijk EA Harman MK Luetzner J Valstar ER Stoel BC Nelissen RGHH Kaptein BL

Introduction. Wear of polyethylene inserts plays an important role in failure of total knee replacement and can be monitored in vivo by measuring the minimum joint space width in anteroposterior radiographs. The objective of this retrospective cross-sectional study was to compare the accuracy and precision of a new model-based method with the conventional method by analysing the difference between the minimum joint space width measurements and the actual thickness of retrieved polyethylene tibial inserts. . Method. Before revision, the minimum joint space width values and their locations on the insert were measured in 15 fully weight-bearing radiographs. These measurements were compared with the actual minimum thickness values and locations of the retrieved tibial inserts after revision. . Results. The mean error in the model-based minimum joint space width measurement was significantly smaller than the conventional method for medial condyles (0.50 vs 0.94 mm, p < 0.01) and for lateral condyles (0.06 vs 0.34 mm, p = 0.02). The precision (standard deviation of the error) of the methods was similar (0.84 vs 0.79 mm medially and both 0.46 mm laterally). The distance between the true minimum joint space width locations and the locations from the model-based measurements was less than 10 mm in the medial direction in 12 cases and less in the lateral direction in 13 cases. Conclusion. The model-based minimum joint space width measurement method is more accurate than the conventional measurement with the same precision. Cite this article: Bone Joint Res 2014;3:289–96